Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1246
    Keywords: Biological monitoring ; Carbon felt dosimetry ; Head space gas chromatography ; Methyl ethyl ketone ; Urinalysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Head space gas chromatography (GC) was applied to measure methyl ethyl ketone (MEK) in urine from 62 MEK-exposed male workers, whose individual intensity of exposure to MEK was monitored utilizing the carbon felt dosimeter. The urinary MEK level increased rapidly to reach a plateau in the first quarter of the daily 8-h work, while very little MEK was detected in the preshift urine. When the MEK levels in the urine at the end of the shift were compared with the afternoon MEK-TWA values, the uncorrected MEK in urine correlated best with MEK in air (r=0.774, n=62), while correction for creatinine gave a comparable result and the correlation was poorer when corrected for a specific gravity of urine or for the lapse of time after preceding passage of urine. Balance of MEK absorption via inhalation and MEK excretion into urine revealed that only 0.1% of MEK absorbed will be excreted unchanged into urine. Wider application of head space GC is discussed for the analysis of unmetabolized solvents in urine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...