Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (117)
  • 1990-1994  (14)
  • 1985-1989  (4)
  • 1950-1954  (99)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 6935-6944 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The timing fiducial system at the Nova Two-Beam Facility allows time-resolved x-ray and optical streak camera data from laser-produced plasmas to be synchronized to within 30 ps. In this system, an Al-coated optical fiber is inserted into an aperture in the cathode plate of each streak camera. The coating acts as a photocathode for a low-energy pulse of 1ω (λ = 1.054 μm) light which is synchronized to the main Nova beam. The use of the fundamental (1ω) for this fiducial pulse has been found to offer significant advantages over the use of the 2ω second harmonic (λ = 0.53 μm). These advantages include brighter signals, greater reliability, and a higher relative damage threshold, allowing routine use without fiber replacement. The operation of the system is described, and experimental data and interpretations are discussed which suggest that the electron production in the Al film is due to thermionic emission. The results of detailed numerical simulations of the relevant thermal processes, undertaken to model the response of the coated fiber to 1ω laser pulses, are also presented, which give qualitative agreement with experimental data. Quantitative discrepancies between the modeling results and the experimental data are discussed, and suggestions for further research are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a simple method for improving the spectral resolution of soft x-ray and extreme ultraviolet spectrographs which use electro-optical detector/intensifiers. In this method, the spectrometer is focused onto a narrow slit which is angled near 90° with respect to the dispersive axis and placed just in front of the detector. Proper choice of the width and angle of the slit is shown to have the effect of expanding the spectrum along the length of the slit to the point where the spatial resolution limitations of the detector are overcome.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 33 (1994), S. 3852-3854 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Laboratory x-ray lasers are currently being studied by researchers worldwide. This paper reviews some of the recent work carried out at Lawrence Livermore National Laboratory. Laser action has been demonstrated at wavelengths as short as 35.6 A(ring) while saturation of the small signal gain has been observed with longer wavelength schemes. Some of the most successful schemes to date have been collisionally pumped x-ray lasers that use the thermal electron distribution within a laser-produced plasma to excite electrons from closed shells in neon- and nickel-like ions to metastable levels in the next shell. Attempts to quantify and improve the longitudinal and transverse coherence of collisionally pumped x-ray lasers are motivated by the desire to produce sources for specific applications. Toward this goal there is a large effort underway to enhance the power output of the Ni-like Ta x-ray laser at 44.83 A(ring) as a source for x-ray imaging of live cells. Improving the efficiency of x-ray lasers in order to produce saturated output with smaller pump lasers is also a goal of this work.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 46 (1990), S. 2088-2091 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1436-2449
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Summary Results of experiments on dark- and photoconductivity of polymeric dibenz[b,i] 1,4,8,11-tetraaza[14]annulenato(μ-pyrazin) iron(II) [Fetaa(pyz)]n are described. By studying the dependence of photoconductivity on electric field, intensity and wavelength it is shown that photogeneration of charge carriers occurred at short wavelengths by an Onsager mechanism and in the near-infrared region by a photoinjection process from the electrodes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European food research and technology 95 (1952), S. 225-231 
    ISSN: 1438-2385
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Zusammenfassung Filtrationsenzyme verändern die Viscosität verschieden veresterter Trockenpektine, so daß danach ihr Gehalt an Pektase und Pektinase bestimmt werden kann. Die Differenz der relativen Viscosität zwischen einem hoch- und einem niederveresterten Pektin kann als Maß für den Pektasegehalt dienen, während die Viscositätsänderung niederveresterter Pektine den Pektinasegehalt zu ermitteln gestattet. Die Arbeit wurde mit ERP-Mitteln unterstützt, wofür auch an dieser Stelle bestens gedankt sei.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European food research and technology 96 (1953), S. 329-335 
    ISSN: 1438-2385
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Zusammenfassung 1. Es wird eine Methode zur Bestimmung der Aromazahl in naturreinen Apfel-und Traubensäften beschrieben. 2. Die Aromazahl frischer Keltermoste und einwandfrei gelagerter Apfelsäfte ist kleiner als der Wert, der bei Zusätzen von Äthylacetat zu aromafrei gemachten Süßmosten in dem ihren pyknometrisch bestimmten Alkoholgehalt entsprechenden Mengen erzielt worden wäre. Bei kaltentkeimten Traubensäften können diese Werte infolge einer sekundären Bukettbildung während der Lagerung überschritten werden. 3. Unter dem Einfluß einer beginnenden alkoholischen Gärung steigt die Aromazahl an. Alle Apfelsäfte mit einer Aromazahl über 4 und alle Traubensäfte mit einer Aromazahl, die dem pyknometrisch bestimmten Alkohol entspricht oder größer ist, sind mit Sicherheit als „nicht naturrein” zu bezeichnen. 4. Durch Bestimmen der Aromazahl läßt sich die „Naturreinheit” der Süßmoste besser charakterisieren als durch das Begrenzen ihres Alkoholgehaltes auf 5 g/l.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    European food research and technology 97 (1953), S. 17-24 
    ISSN: 1438-2385
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Zusammenfassung Der „Tankgeschmack”, der bei den nach dem Böxi-Verfahren eingelagerten Apfelsäften auftreten kann, ist chemisch an einem Milchsäuregehalt des Saftes über 0,4 g/l zu erkennen. Die Milchsäurebildung beginnt sofort nach der Einlagerung, solange die Temperatur im Tank noch über 15° C beträgt. Die Milchsäure wird unter Änderung des pH-Wertes aus Apfelsäure gebildet. Aus 1 g Apfelsäure entstehen 0,46–0,5 g Milchsäure. Apiculatus-Hefe undMucor racemosus bleiben unter Kohlensäuredruck lebensfähig, bilden jedoch keine Milchsäure wieBaeterium gracile. Da unter Kohlensäuredruck die im Most vorhandenen Kokken und Stäbchen zur Milchsäurebildung befähigt sind, empfiehlt es sich, die Moste vor der Einlagerung völlig zu entkeimen. Bei Lagertemperaturen über 10° C ist diese Entkeimung unerläßlich, andernfalls die Moste den „Tankgeschmack” annehmen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European food research and technology 99 (1954), S. 188-196 
    ISSN: 1438-2385
    Source: Springer Online Journal Archives 1860-2000
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Zusammenfassung Das für die Weine von 10 Vol.- % Alkoholgehalt geltende Lösungsgleichgewicht von Weinsäure und Kalium ist aus Gleichgewichtskurven zu erkennen, die unter bestimmten Bedingungen mit alkoholisch-wäßrigen Lösungen aufgestellt wurden. Die Weinsteinausscheidung hängt vom Gehalt an Kalium- und Weinsäure-Ionen ab und nimmt mit abnehmender Temperatur zu. Weine mit einem Alkoholgehalt von 10 Vol.-% können bis auf —4°C gekühlt werden. Die Weinsteinausscheidung ist pH-abhängig und steigt innerhalb des pH-Bereiches 2,8–3,5 mit zunehmendem pH-Wert an, führt aber zur Senkung der pH-Zahl. Der normale Calciumgehalt des Weines übt keinen Einfluß auf die Weinsteinausscheidung aus, d. h. durch Kühlen fällt kein Calciumtartrat aus. Der Extraktgehalt, insbesondere ein Zuckerrest ist ohne Einfluß auf die Weinsteinausscheidung, Nur blank filtrierte Weine können ohne Rühren gekühlt werden. Die 5–7tägige Unterkühlung der Konsumweine führt stets zu weinsteinstabileu, in seltenen Fällen auch zu eiweißstabilen Weinen. Die Unterkühlung der Weißweine nach dem 1. Abstich auf —4°C kann daher nur eine teilweise Stabilisierung herbeiführen und ist, sofern eine Frühfüllung beabsichtigt wird, noch mit anderen kellertechnischen Maßnahmen zu verbinden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...