Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Digitale Medien  (14)
  • 1990-1994  (9)
  • 1980-1984  (5)
Materialart
  • Digitale Medien  (14)
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 2493-2495 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We have fabricated a Si metal-oxide-semiconductor field-effect transistor with a 20-nm channel length using a novel step/edge technique. An Al gate is evaporated onto a step in the SiO2 gate oxide. A second Al gate, separated from the first by a plasma-enhanced chemical-vapor-deposited SiO2 layer, provides inversion layer extensions of the source and drain contacts. Electrical conductance measurements indicate a channel length approximately equal to the fabricated gate length.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1077-3118
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We have demonstrated a new planarized all-refractory technology for low Tc superconductivity (PARTS). With the exception of the Nb-AlOx-Nb trilayer preparation, the processing is done almost exclusively within an advanced Si technology fabrication facility. This approach has allowed us to leverage highly off of existing state-of-the-art lithography, metal etching, materials deposition, and planarization capabilities. Using chemical-mechanical polish as the planarization technique we have fabricated Josephson junctions ranging in size from 0.5–100 μm2. Junction quality is excellent with the figure of merit Vm typically exceeding 70 mV. PARTS has yielded fully functional integrated Josephson devices including magnetometers, gradiometers, and soliton oscillators.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 37 (1982), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: The sump of a Fluotec Mk II vaporiser separated from the upper portion of the vaporiser during an anaesthetic, and fell off. The danger to the patient is discussed, as well as the possible causes for this occurrence.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 26 (1993), S. 1060-1064 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Infection 22 (1994), S. 233-237 
    ISSN: 1439-0973
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Conclusion The presence of resistant pneumococcal organisms has become a major problem in the world today. These organisms are responsible for changing the methodology required for susceptibility testing and for the newly proposed guidelines for resistance. These newly proposed MICs are still under consideration because of the limited data used for their establishment. The treatment of resistant pneumococcal infections outside of the central nervous system is not yet well standardized. Central nervous system infections should be approached with care and a knowledge of current recommendations for their therapy. We expect changes in the recommendations for therapy over the coming years until a standardized approach can be established.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Infection 22 (1994), S. 361-361 
    ISSN: 1439-0973
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1435-1803
    Schlagwort(e): myocardial ischemia ; revascularization ; laser ; systolicperfusion
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Laser-induced intramyocardial revascularization (LIR) has been used to promote direct communications between blood within the ventricular cavity and that of the existing myocardial vasculature in an attempt to increase perfusion in patients with ischemic heart discase. This study was conducted to measure the effects of LIR channels on regional myocardial flood flow (microspheres), cardiac mechanics (sonomicrometers), and myocardial tissue pressures in 18 dogs. Under baseline hemodynamic conditions (mean HR=165.2±11.4 bpm, LVP=123.6±22.9/4.0±1.8 mmHg, AoP=112.8±27.1/77.0±22.5 mmHg), myocardial blood flow in laser-treated tissue (mean =1.11±.10 cc/min/gm before laser; .71±.19 cc/min/gm after laser) was reduced as compared to blood flow in control tissue (mean=1.12±.15 cc/min/gm before laser; 1.25±.22 cc/min/gm after laser). Regional myocardial systolic shortening (11.32%±3.82% before laser; 7.49%±2.86% after laser) was decreased by 33%. During simultaneous reversible ligation of the LAD and LCCA for 2 min, when intramyocardial channels represented the only tissue access for the injected microspheres, blood flow in laser-treated tissue was not increased above that of the control non-lasered tissue. However, regional blood flow was greater in laser-treated ischemic tissue (mean=.61±.12 cc/min/gm) than in untreated ischemic areas (mean=.04±.03 cc/min/gm) when left ventricular pressure (LVP) was acutely elevated (mean SLVP=207.0±16.1 mmHg). Using these measurements, a model is proposed to predict regional systolic pressure gradients between the left ventricular cavity and coronary intramyocardial vasculature required to permit restoration of blood flow to ischemic myocardium. We conclude that improved perfusion via laser-induced intramyocardial channels does not occur in otherwise normal myocardium exposed to acute coronary ligation and only small improvements in perfusion are noted when LVP is significantly elevated. Consideration of further clinical application of this approach is seriously cautioned awaiting additional experimental studies.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Investigational new drugs 2 (1984), S. 281-286 
    ISSN: 1573-0646
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Summary Twenty-four patients with a variety of solid tumors entered a Phase I trial with 4-demethoxydaunorubicin, a new analogue of daunorubicin. The drug was given as a single oral dose of 10–60 mg/m2 repeated every 3–4 weeks. Leukopenia was the dose-limiting toxicity. Other toxic effects included mild to moderate nausea and vomiting. Sixty mg/m2 was found to be the maximum tolerated dose in patients with fair tolerance to chemotherapy and normal liver function. Similar hematologic toxicity was reported in patients with very extensive prior chemotherapy or diffuse bone and/or liver metastases receiving 50 mg/m2. However, the wide range of the WBC nadirs reported with the same dose in ‘good risk’ cases, suggest that 40 mg/m2, increased up to 50 mg/m2 in the absence of significant myelotoxicity, could be more safely proposed as starting dose for Phase II trials. Pharmacokinetic studies were performed in five patients given a single dose of 40–60 mg/m2. IMI-30 (NSC 256439) appears to be rapidly absorbed and rapidly eliminated from plasma by means of a rapid and extensive biotransformation to 13-OH-idarubicin. The 13-dihydroderivative was present at higher and more prolonged levels than the parent compound, with an elimination half-life of about 40 hours.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Investigational new drugs 2 (1984), S. 369-374 
    ISSN: 1573-0646
    Schlagwort(e): Phase I trial ; 4′-deoxydoxorubicin ; esorubicin
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Summary Twenty-six patients with various solid tumors entered a Phase I trial with 4′ -Deoxydoxorubicin (Esorubicin, IMI-58), a new doxorubicin analogue. The drug was administered weekly i.v. for 3–4 weeks. Leukopenia proved to be dose limiting. The maximum tolerated dose (MTD) was reached at 20 mg/m2 weekly for 3 weeks. For Phase II trials, a weekly dose of 15 and 17.5 mg/m2 can be proposed for poor and good risk patients respectively. Non-hematologic toxicity was minimal. Phase II trials with this new anthracycline are warranted.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 377-386 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Biomaterial-centered infection is an important cause of the failure of prosthetic implants and organs. Because neutrophils mediate host defense against infection, the effect of biomaterials on neutrophil superoxide release and the mechanism of that effect were investigated using three materials commonly employed in surgical practice. The graft materials were expanded polytetrafluorethylene (PTFE), polyurethane and woven dacron. Polystyrene, a commonly used laboratory support vessel, was also studied. Both polystyrene and polyurethane were activating, but serum inhibitable, whereas PTFE was nonactivating, and woven dacron was not activating unless serum was present. The signaling mechanisms used by these materials demonstrated time and material dependency. Pertussis toxin inhibition of G proteindependent activation had little or no effect on biomaterial induced activation, whereas FMLP-induced activation of the same biomaterial-associated cells was inhibited. Protein kinase C inhibition with staurosporine greatly inhibited polystyrene-induced activation, but had only a partial effect with polyurethane and even less effect with the activation associated with serum-treated woven dacron. These studies demonstrated that biomaterial contact-induced neutrophil activation differed from that described for cells in suspension, and showed that activation mechanisms on one material cannot be extrapolated to mechanisms on other materials. © 1994 John Wiley & Sons, Inc.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...