Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Summary. The clinical significance of placental perforation and bloodstained amniotic fluid was studied in a group of 7238 Danish women undergoing mid-trimester amniocentesis for prenatal diagnosis under ultrasound guidance. The risk of spontaneous abortion was significantly increased both in pregnancies where the placenta was perforated and in those with blood-stained amniotic fluid. The risk estimate nearly doubled after placental perforation and more than doubled with a bloody tap. It is concluded that for women at relatively low risk of a fetal genetic abnormality, the indication of the amniocentesis should be reconsidered if a placental perforation is unavoidable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 1793-1803 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We present an experimental setup for measuring the electrical conductance through metallic quantum point contacts (QPCs) under constant or time-dependent bias voltage conditions. The response time of the setup is as short as 25 ns and typical bias voltages range from 10 mV to 2 V. A function generator is used as bias voltage supply. With this, voltage bursts with a frequency of up to 100 kHz can be applied to the QPCs, whereby current-to-voltage (I–V) curves can be acquired using a homebuilt, 30 MHz bandwidth I–V converter, and a 100 Msamples/s digital storage oscilloscope. Test experiments on resistors show that nonlinear contributions to the I–V curves are always less than 1% of the current for all applied voltages. From the slope of the I–V curves, the conductance can be determined with an accuracy better than 1%. The QPCs are formed between a single-crystal metal sample and the tip of a scanning tunneling microscope under clean ultrahigh vacuum conditions. We demonstrate how the setup can be used to capture the I–V curves of several metastable states in a Au QPC, as it breaks during a period of 200 μs at room temperature. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 114 (2001), S. 6518-6525 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The microcanonical temperature is shown to be a useful concept in calculations of the decay of a small isolated system with well defined energy. A simpler and more transparent description is obtained than in Klots' formulation of finite-heat-bath theory, where the system is represented by a canonical ensemble. As a further illustration of the utility of the microcanonical temperature concept, we discuss a formula derived by Dunbar for the probabilities for excitation of a single oscillator in a collection of harmonic oscillators with well defined total energy. This formula expresses the excitation probabilities in terms of the temperature for a canonical ensemble with mean energy equal to the energy of the system. However, a much improved accuracy is obtained if the canonical temperature and heat capacity are replaced by their microcanonical values. We justify this replacement through a modified derivation, in which the microcanonical temperature appears as the canonical temperature of a fictitious system with level density ρ′(E), the derivative of the level density ρ(E) of the collection of oscillators. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1451-1456 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: By combining the time-of-flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3-J pulse energy, 300-ps pulse duration, 0.5-Hz repetition rate) together with a 700-MHz bandwidth detection and registration system yields a spatial resolution of about 12 cm. A spectrometer with six channels in the wavelength range 400–800 nm gives a dynamic range of the temperature measurements of 0.3–20 keV. The stray light problem in the backscatter geometry is overcome by spectral discrimination and gating of the photomultipliers. A ruby filter in the spectral channel containing the laser wavelength allows calibration of the vignetting along the line of sight by means of Raman scattering, enabling the measurement of density profiles. The low level of background signal due to the short integration time for a single spatial point yields low statistical errors (ΔTe /Te ≈6%, Δne /ne ≈4% at Te =6 keV, ne =3×1019 m−3 ). Goodness-of-fit tests indicate that the systematic errors are within the same limits. The system is described and examples of measurements are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3265-3269 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The electronics for the microchannel plate photomultiplier tubes used in the LIDAR (Light Detection and Ranging) Thomson scattering diagnostic on the JET tokamak are described. It is shown how the microchannel plate photomultiplier tubes are gated with a very small coupling between gate signal and output, and how ≈300 V transient pulses with rise times of 230 ps are clipped to safe levels of ≈40 V.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design of a photoemission microprobe beamline at the MAX laboratory is presented. The beamline will utilize the radiation from a 26 period undulator on the 550-MeV MAX storage ring. The beamline will be capable of providing about 1010 photons/s of monochromatized radiation (bandwidth better than 0.25 eV) in the energy range of 20 to 150 eV focused into a submicrometer focal spot. It will be used for scanning photoemission experiments with a lateral resolution better than 1 μm. The optical system is comprised of a plane-grating monochromator with a Kirkpatrick–Baez objective and a specially designed ellipsoidal focusing mirror.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 708-710 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We present measurements of current–voltage (I–V) curves on gold quantum point contacts (QPCs) with a conductance up to 4 G0 (G0=2e2/h is the conductance quantum) and voltages up to 2 V. The QPCs are formed between the gold tip of a scanning tunneling microscope and a Au(110) surface under clean ultra-high-vacuum conditions at room temperature. The I–V curves are found to be almost linear in contrast to previous reports. Tight-binding calculations of I–V curves for one- and two-atom contacts are in excellent agreement with our measurements. On the other hand, clearly nonlinear I–V curves are only observed when the sample has been cleaned in air. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of food science & technology 21 (1986), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Anthocyanin extraction from elderberry pomace is improved by mechanical disintegration and use of aqueous HCl in place of acidified ethanol as extractant, with pH being important in determining extractant effectiveness. Extraction at low solvent:pomace ratios gives extracts of higher concentration and lower volume, but with reduced efficiency. Enzyme pretreatments do not improve extractability from exten-sively crushed pomace, and if of extended duration, can result in anthocyanin break-down. Vacuum evaporation of extracts gave little loss of anthocyanins, and combined with freeze drying, produced materials with high anthocyanin retention.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Allergy to hazelnuts is a common example of birch pollen related food allergy. Symptoms upon ingestion are often confined to the mouth and throat, but severe systemic reactions have been described in some patients. The aim of the study was to evaluate the reduction in allergenicity by roasting of the nuts.Methods: Double-blind, placebo-controlled food challenges (DBPCFC) with roasted hazelnuts (140°C, 40 min) were performed in 17 birch pollen allergic patients with DBPCFC-confirmed food allergy to raw hazelnuts. The effect of roasting was further evaluated by skin prick test (SPT), histamine release (HR), measurement of specific IgE, and IgE-inhibition experiments.Results: In 5/17 patients the DBPCFC with the roasted nuts were positive. The symptoms were generally mild and included OAS (oral allergy syndrome) in all patients. Roasting of the nuts significantly reduced the allergenic activity evaluated by SPT, HR, specific IgE, and IgE-inhibition. Immunoblotting experiments with recombinant hazelnut allergens showed sensitization against Cor a 1.04 in 16/17 patients and against Cor a 2 in 7/17 patients. None of the patients were sensitized to Cor a 8. Challenge-positive patients did not differ from the rest in IgE-binding pattern.Conclusions: All the applied methods indicated that roasting of hazelnuts reduces the allergenicity, but since 5/17 birch pollen allergic patients were DBPCFC-positive to the roasted nuts, ingestion of roasted hazelnuts or products containing roasted hazelnuts can not be considered safe for a number of hazelnut allergic consumers. For patients with a history of severe allergic symptoms upon ingestion of hazelnuts, thorough and conscientious food labelling of hazelnuts and hazelnut residues is essential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The ability of the new generation H1-receptor antagonist, astemizole, to prevent histamine-induced airway obstruction and exercise-induced asthma (EIA) was studied in 20 children with asthma. The study was a randomised clinically controlled trial of oral astemizole versus placebo in a cross-over study. In each of the two treatment periods the children were tested at days 0, 6, 15 and 22 of therapy. The two treatment periods were separated by a washout period of 50 days, and at each visit a bronchial challenge with increasing concentrations of histamine followed by an exercise test was performed, and peak flow and asthmatic symptom score were recorded daily. The children tolerated significantly higher mean concentrations of histamine when treated with astemizole compared with placebo (P 〈 0.001). Astemizole postponed the response to exercise, but no change in the maximal response was found. No differences between the treatment periods were found regarding frequency of asthmatic symptoms or the daily recording of peak flow.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...