Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 62 (1958), S. 377-379 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    European journal of neuroscience 19 (2004), S. 0 
    ISSN: 1460-9568
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The goal of this study was to compare the lateral inhibition and the habituation in the human auditory cortex, two important physiological effects during auditory processing that can be reliably measured by means of magnetoencephalography when recording auditory evoked fields. Applying 40-Hz amplitude-modulated stimuli allowed us to record simultaneously the slow transient evoked and the steady-state fields and thus to characterize the lateral inhibition and the habituation effect in primary and non-primary auditory cortical structures. The main finding of the study is that the lateral inhibition effect of non-primary auditory areas as measured on the major component of the slow transient auditory evoked field (N1) is significantly stronger than the corresponding habituation effect. By contrast, this effect was not observed for the 40-Hz steady-state fields, characterizing the activation of the primary auditory cortex in humans. The results might be interpreted as (i) evidence that the inhibition mediated by lateral connections is stronger than the habituation of excitatory neurons in the non-primary auditory cortex and (ii) the processing hierarchy in the human auditory cortex is demonstrated by the different behaviour of lateral inhibition and habituation in primary and non-primary auditory cortical structures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 61 (1955), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 223 (1979), S. 345-348 
    ISSN: 1434-4726
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary 120 caloric vestibular tests (50 ml water of 30° resp. 44° in 30 s) were carried out on 30 normal persons 20—30 years of age. The responses were analyzed as to the reliability of evaluation using Frenzel's glasses, in case of a limited evaluation to a defined observation period. This observation period was located at different time-intervals after stimulation and compared to the maximal phase of reaction registered by ENG simultaneously. The difference between the number of beats within the fixed observation period and the number of beats within the maximal phase of reaction was defined as the rate of error. The interval (20, 50) s after the end of stimulation was highly qualified to present the intensity of the vestibular response. As some reactions are very slow and finished before the 20th s the interval (10, 70) s was suggested, too. The intervals (20,50) — and (10,70) s showed low rates of error and high correlation to the maximal reaction. This method can be used for clinical routine. Difficult problems can only be answered by more elaborate proceedings.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Lärmschwerhörigkeit ; Begutachtung ; Kochleäre Hörstörung ; Überschwellige Hörprüfung ; Pseudohypakusis ; Keywords Noise deafness ; Expert opinion of noiseinduced hearing loss ; Cochlear hearing disorder ; Supraliminal hearing test ; Pseudohypacusis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Background and objective. Proof of cochlear hearing loss is an essential prerequisite for the diagnosis of noise deafness. For this purpose, the Königsteiner instruction leaflet (Königsteiner Merkblatt) recommends among other items the SISI test. Patients/methods. The results of the SISI test at 1 and 4 kHz were analysed for 100 expert opinions of noise (200 ears). Results. 10% of the subjects showed at 1 and 4 kHz a positive and 44% a negative result. At 1 kHz, 46% indicated a negative result and at 4 kHz a positive result. In the group with a negative SISI test at both frequencies, 74% demonstrated characteristics of pseudohypacusis. There was no correlation between a retrocochlear hearing disorder and a negative SISI test. Conclusions. Our analysis demonstrated that the negative SISI test is more often evidence of pseudohypacusis rather than a retrocochlear disorder. Consequently, the validity of a negative SISI test is limited.
    Notes: Zusammenfassung Hintergrund und Fragestellung. Wesentliche Voraussetzung für die Diagnose einer Lärmschwerhörigkeit ist der Nachweis einer kochleären Hörstörung. Hierzu empfiehlt das “Königsteiner Merkblatt” neben anderen überschwelligen Verfahren insbesondere den SISI-Test. Im Rahmen der Begutachtung fielen unverhältnismäßig viele negative Ergebnisse im SISI-Test auf, ohne dass sich weitere Hinweise auf eine retrokochleäre Hörstörung fanden. Da ein negativer SISI-Test auch Zeichen einer Pseudohypakusis sein kann, haben wir den Zusammenhang zwischen einem negativen Ergebnis im SISI-Test und anderen Zeichen einer Pseudohypakusis im Rahmen der Begutachtung näher untersucht. Patienten/Methodik. Es wurden 100 “Lärmgutachten” (200 Ohren) bezüglich ihrer Ergebnisse im SISI-Test bei 1 und 4 kHz analysiert und anschließend in 4 verschiedene Gruppen (Test bei 1 und 4 kHz positiv bzw. negativ, Test bei 1 kHz positiv und 4 kHz negativ und vice versa) eingeteilt. Jede Gruppe wurde im Hinblick auf Zeichen einer Pseudohypakusis (Diskrepanz zwischen Ton- und Sprachaudiogramm, Typ V im Békésy-Audiogramm) und auf Hinweise auf eine retrokochleäre Hörstörung untersucht. Ergebnisse. 10% der Versicherten lieferten bei beiden Frequenzen ein positives und 44% ein negatives SISI-Testergebnis. Bei 46% der Untersuchten fand sich bei 1 kHz ein negatives und bei 4 kHz ein positives Ergebnis. In der Gruppe mit negativem SISI-Test in beiden Frequenzen zeigten 74% eindeutige Zeichen einer Pseudohypakusis. Bei keinem Versicherten fanden sich jedoch Hinweise auf eine retrokochleäre Hörstörung. Schlussfolgerungen. Unsere Untersuchungen zeigen, dass der negative SISI-Test im Lärmgutachten sehr häufig Zeichen einer Pseudohypakusis und so gut wie nie das einer retrokochleären Hörstörung ist. Somit ist die Aussagekraft dieser Methode bei negativem Testergebnis deutlich eingeschränkt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    HNO 48 (2000), S. 346-356 
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Kinetosen ; Reisekrankheit ; Seekrankheit ; Flugkrankheit ; Space motion sickness ; Intersensorischer Konflikt ; Pseudokinetosen ; Key words Kinetosis ; Pseudo-kinetosis ; Space motion sickness
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Motion sickness is a well know nausea and vomiting syndrom whose physical signs occur during travel by sea, automobile, airplane, and space. This review describes current concepts concerning the aetiology, nature and therapy of this common phenomenon. Motion sickness involve a neural mismatch or confusion between the vestibular, visual, and proporioceptive systems. Therapy is directed towards decreasing conflicting sensory input, controlling nausea, and speeding the process of adaptation.
    Notes: Zusammenfassung Der Begriff Kinetose bezieht sich auf einen Symptomenkomplex, der durch verschiedene Beschleunigungsreize ausgelöst werden kann, die außerhalb der individuellen Adaptationsschwelle liegen. Es handelt sich also nicht um ein Krankheitsbild sui generis, obgleich die Symptome, die durch See-, Flug und Autoreisen ausgelöst werden, sondern um eine physiologische Reaktion. Grundlage der Kinetose ist ein intersensorischer Konflikt zwischen 2 oder mehreren konkurrierenden Sinneseindrücken. Dieser Konflikt kann sowohl intralabyrinthär, d. h. zwischen den afferenten Signalen der Bogengänge und Otolithen, als auch vestibulovisuell entstehen. In diesem Übersichtsartikel werden detailliert die Entwicklung der Kinetose-Forschung bis zur Gegenwart dargestellt, die verschiedenen Entstehungstheorien erläutert und unterschiedliche therapeutische Ansätze präsentiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-1440
    Keywords: Hypothyroidism ; Children ; T3/T4 preparations ; TRH-test ; Triiodothyrinine ; T3/T4 quotient ; Hypothyreose ; Kinder ; T3/T4-Kombinationspräparat ; TRH-Test ; Trijodthyronin ; T3/T4-Quotient
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 23 Kindern mit primärer Hypothyreose, die mit Thyroxin (T4) und Trijodthyronin (T3) enthaltenden Kombinationspräparaten behandelt worden waren, wurden TRH-Teste, TBI, T3- und T4-Bestimmungen durchgeführt. Die T3/T4-Quotienten wurden berechnet. 7 von 10 Patienten mit TRH-refraktären TSH-Werten und normalen T4-Spiegeln wiesen überhöhte T3-Werte auf. Bei 6 von diesen Patienten konnten pathologisch überhöhte T3/T4-Quotienten beobachtet werden. Eine TRH-refraktäre TSH-Suppression wurde nur bei hohen T4-Werten gefunden. Nach einer Reduktion der Substitutionsdosis normalisierten sich die überhöhten T3-Spiegel. Die Befunde zeigen, daß nicht nur die T4-Werte sondern auch die TSH- und T3-Spiegeln unter der Behandlung mit Schilddrüsenhormonen kontrolliert werden sollten. Die Durchführung der Substitutionstherapie der Hypothyreose mit T3/T4-Kombinationspräparaten im Verhältnis 1:4 sollte überdacht werden.
    Notes: Summary TRH-tests, triiodothyronine (T3), TBI, and thyroxine (T4) determinations were carried out in 23 children with primary hypothyroidism treated with T3/T4-preparations. T3/T4 quotients were calculated. 7 out of 10 patients with TRH refractory TSH values and normal T4 levels had T3 values above normal range. In 6 of them pathologically elevated T3/T4 quotients could be observed. A TSH refractory TSH suppression was only found in patients with superior normal T4 values. After a reduction of the replacement doses the T3 values were normal. The findings show — that not only the T4 values should be controlled under treatment with thyroid preparations but also the T3 and TSH serum levels. The replacement therapy of hypothyroidism with T3/T4 preparations in proportion 1:4 should be revised.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Plant systematics and evolution 102 (1955), S. 273-300 
    ISSN: 1615-6110
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Monatshefte für Chemie 86 (1955), S. 564-575 
    ISSN: 1434-4475
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Zusammenfassung Es wird ein Zusatzgerät zu einem handelsüblichen Polarographen beschrieben, das die Verwendung von Ladestromkompensation und Vorpotential sowie die Aufnahme differential-polarographischer und derivierter Kurven gestattet. Ferner ist es möglich, Kombinationen dieser Schaltungen sowohl für Quecksilbertropfelektroden als auch für rotierende Platinelektroden durch einfache Umschaltung anwenden zu können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 257 (2000), S. 193-198 
    ISSN: 1434-4726
    Keywords: Key words Linear acceleration ; Inter-aural axis ; Visual ; vestibular interaction ; Dynamic visual acuity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated visual-vestibular interactions during linear acceleration along the inter-aural axis. Eighteen healthy volunteers and two patients with central neurological diseases were subjected to transaural linear acceleration in the direction of gravity force (frequency: 0.5–1.5 Hz; amplitude: 5 cm). During linear acceleration, eye movements were recorded under three test conditions: eyes closed (EC), while staring at an imaginary target (IT) and during the testing of dynamic visual acuity (DVA). As parameters of evaluation we used the amplitude of horizontal eye movements, phase shift and the decrease of DVA threshold (DVAT). Under all test conditions, eye amplitude increased with rising stimulus frequency and exceeded, especially in the higher frequency range, a hypothetically calculated eye amplitude for smooth pursuit. The combination of a visual and vestibular input (DVA and IT) led to a better compensation (lower phase shift) than under vestibular stimulation alone (EC). Eye movements during low-frequency stimulation depended more on the visual system while responses in the higher frequency range were mainly triggered by the otolith organ. At 1.5 Hz the compensatory function of the visual-vestibular system was limited (rising phase shift) and DVAT decreased even in a significant number of healthy subjects. Patients with diseases of the central nervous system showed a higher phase shift and thus a stronger decrease of DVAT (two levels) already at a stimulus frequency of 1.25 Hz.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...