Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2020-03-23
    Description: Die Arbeitstagung \glqq Scientific Computing in der Medizin\grqq , kurz SCMED \grq 97, findet vom 22. - 23. September 1997 im neu errichteten Gebäude des Konrad-Zuse-Zentrums auf dem Dahlemer naturwissenschaftlichen Campus der Freien Universtät Berlin statt.
    Keywords: ddc:000
    Language: English
    Type: reportzib , doc-type:preprint
    Format: application/postscript
    Format: application/pdf
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 805 (1996), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2102
    Keywords: Schlüsselwörter 3D-Bestrahlungsplanung ; Minimal-invasive Verfahren ; Konformierende Bestrahlung ; Bildkorrelation ; Stereotaxie ; Radiochirurgie ; Key words 3-D planning of radiation treatment ; Minimally invasive procedures ; Conformal radiation ; Image correlation ; Stereotaxy ; Radiosurgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Modern imaging techniques are a substantial part of treatment planning for minimally invasive radiotherapeutic procedures. The aim is three-dimensional assessment of the target volume and adjacent critical structures. In this paper, we report on our clinical experience with a precise system for stereotactic image correlation. Hereby, the advantages of each imaging modality can be combined. Precise immobilization of the patient is a prerequisite. The immobilization method has an accuracy of less than 1 mm. This method was evaluated in a clinical study in which a tumor control rate of 93 % was achieved in patients with brain metastases after stereotactic single high dose radiotherapy. This indicated the excellent reliability of this treatment planning method. The integration of functional image information, such as blood flow or activation of cerebral cortical areas, will be evaluated in the future.
    Notes: Zusammenfassung Die modernen bildgebenden Verfahren spielen eine wichtige Rolle bei der Planung minimal-invasiver Bestrahlungsverfahren. Ziel ist die präzise dreidimensionale (3D-) Erfassung des Zielvolumens und der umgebenden kritischen Strukturen. In diesem Beitrag werden Verfahren zur präzisen stereotaktischen Bildkorrelation für die Bestrahlungsplanung beschrieben. Durch diese Technik können die Vorzüge der einzelnen bildgebenden Verfahren kombiniert werden. Die reproduzierbare Lagerung ist hierfür eine Grundvoraussetzung. Das beschriebene Immobilisationsverfahren hat eine Genauigkeit von weniger als 1 mm. Der klinische Einsatz bei der stereotaktischen Einzeithochdosisbestrahlung, der sog. Radiochirurgie, bei Patienten mit Hirnmetastasen zeigte eine Tumorkontrollrate von 93 % und belegt damit die Zuverlässigkeit der Methode. Es muß in Zukunft evaluiert werden, wie auch funktionelle Meßgrößen in die Bestrahlungsplanung einbezogen werden können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 36 (1996), S. 737-743 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Therapieplanung ; Chemotherapie ; Finite-Elemente-Methode ; Key words Treatment planning ; Chemotherapy ; Finite elements method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary A treatment planning system for stereotactical neurosurgery has been developed. A modular system has been designed which is readily extendable. Different modalities of tomography (CT, MRI) can be correlated and presented simultaneously in transverse, frontal and sagittal reconstructions. The volumes of interest are segmented with respect to the different modalities, and the positions of the catheters are defined. The calculation of dose must be adapted to the physical requirements of the therapy and is designed as an independent process. The calculated data are shown in various presentations. The treatment planning system is applied to intratumoral chemotherapy. The drug is encapsulated in small carriers for prolonged release and injected via catheters directly into the tumor interstitium, bypassing the blood-brain barrier. The dose is calculated using the time-dependent, three-dimensional finite elements method. To achieve homogeneous temporal and spatial drug distribution it is necessary to use a great number of catheters due to the limited diffusion of drug, which is not practical in neurosurgery. Therefore this therapy concept is useful for small volumes only. Interstitial hyperthermia and brachytherapy, in contrast to intratumoral chemotherapy, show successful clinical results.
    Notes: Zusammenfassung In dieser Arbeit wird ein Therapieplanungssystem für stereotaktische Anwendungen in der Neurochirurgie vorgestellt. Das Planungssystem ist als ein modulares, leicht erweiterbares Programmpaket realisiert, mit dem man Tomographieaufnahmen verschiedener Modalitäten (CT, MRT) korreliert und darstellt, Tumor und Risikoorgane segmentiert und Katheterpositionen definiert. Für unterschiedliche Therapieformen wie interstitielle Hyperthermie, intratumorale Chemotherapie oder Brachytherapie sind die Dosisberechnungen als ein eigenständiges Programm konzipiert worden. Die berechneten Ergebnisse werden in verschiedenen Darstellungen präsentiert. Eine Anwendung für das Therapieplanungssystem ist die intratumorale Chemotherapie. Bei dieser Therapie ist der Wirkstoff in Carrier verkapselt und wird über Katheter direkt in das Tumorgewebe appliziert. Die Dosisberechnung erfolgt mit der zeitabhängigen, dreidimensionalen Finite-Elemente-Methode. Die zeitliche und räumliche Darstellung der Wirkstoffverteilung zeigt, daß die intratumorale Chemotherapie aufgrund der großen Zahl an Kathetern nicht bei größeren Tumoren anwendbar ist. Im Gegensatz dazu zeigt die interstitielle Hyperthermie und die Brachytherapie auch bei größeren Tumoren gute klinische Ergebnisse.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 324 (1983), S. 160-162 
    ISSN: 1432-1912
    Keywords: Target size analysis ; Multiple opiate receptors ; Molecular weight determination
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The functional size of different types of opiate receptors was determined in situ by the radiation inactivation technique. The Mr of opiate binding sites was estimated to be about 90,000 daltons; the data revealed no significant differences between the molecular sizes of either μ-, δ- or ϰ-sites in rat brain membranes. An identical molecular size was found also for the δ-sites in the neuroblastoma x glioma hybrid cell clone, NG 108-15.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0942-0940
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new method for the direct transformation not only of a target point, but also of the whole tumour outlines from sagittal, coronal, and oblique computer calculated CT-reconstructions to stereotactic X-ray films of any scale is presented. The role of this method in the stereotactic therapy of intracranial tumours and the possibilities which are thus provided are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 125 (1993), S. 142-149 
    ISSN: 0942-0940
    Keywords: Stereotactic technique ; CT-guided stereotaxy ; computer-assisted treatment planning ; histological diagnosis ; brain neoplasms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary On the base of a stereotactic device originally described by Riechert and Mundinger a three-dimensional localization and treatment planning system for CT-guided computer assisted stereotactic procedures has been developed. The experience with 338 patients, in which image guided stereotaxy has been used for the assessment of various intracerebral lesions, is presented. In 54 of these patients the cannula was introduced with a 20 MHz Doppler-probe positioned at the tip of the needle. A comparison of tissue specimens taken stereotactically with tissue material after tumour resection and/or autopsy was performed in 35 patients. The accuracy of the histological diagnosis was 88%. Bleeding as a complication due to the stereotactic intervention occurred in 8 patients (2.4%). Two of these patients had a fatal outcome (mortality: 0.6%). The morbidity (transient and permanent deterioration of the clinical status) was 1.2%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0942-0940
    Keywords: Ependymoma ; interstitial irradiation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In this case report a patient with a large intraventricular benign ependymoma is presented. The tumour was treated with stereotactically implanted Iodine-125 seeds and interstitial irradiation. Extension (diameter: 6.5 cm) and volume (112.5 ml) of the lesion caused the application of an unusually low dose (tumour surface dose: 40 Gy). The tumour shrank significantly within a few weeks. Follow-up at nearly 5 years shows the patient to be tumour free.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0942-0940
    Keywords: Tissue ablation ; laser/tissue interaction ; shortpulsed lasers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The basis for most laser applications in neurosurgery is the conversion of laser light into heat when the incident laser beam is absorbed by the tissue. Irradiation of neural tissue with laser light therefore leads to its thermal damage. However, due to the diffusion of heat energy into the surrounding tissue, often there is thermal damage to neural tissue outside the area of the target volume. These are the characteristics of thermal laser/tissue interaction. In this paper we discuss how we used three different short-pulsed lasers to achieve non-thermal ablation of neural tissue. Three different short-pulsed lasers were used to generate ultrashort laser pulses in the picosecond to femtosecond range. The interaction of such laser pulses with tissue was predicted to be nonthermal. The short-pulsed lasers were used for the ablation of neural tissue using an in vitro calf brain model. The histopathological examination of the lesions revealed that the neural tissue had been removed very precisely without any sign of thermal damage to the surrounding tissue.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0942-0940
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary For stereotactic biopsy, intracavitary and interstitial irradiation of intracranial tumours, stereotactic CT investigations are of utmost importance. Targetpoints within a tumour as well as the tumour-outlines have to be transferred precisely from transverse and longitudinal CT sections to stereotactic X-ray images. For this purpose, the stereotactic apparatus of Riechert and Mundinger has been equipped with a fixation system of carbon fibre and a measuring phantoma of plexiglass with embedded steel wires allowing stereotactic CT scanning without artefacts. The stereotactic coordinates (x, y, z) of any target point can be taken directly from transverse CT images with high accuracy. The tumour outlines can be transferred to the stereotactic coordinate system from longitudinal CT reconstructions using special computer programmes. Precise transfer is possible if the CT investigation is performed stereotactically.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...