Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 74 (1999), S. 1200-1202 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Irradiating intense femtosecond laser pulses on a glass sample containing silver nanoparticles results in permanent sample color changes if the laser wavelength is in the region of the particles' surface plasmon resonance. In particular, even a single pulse of appropriate intensity can modify the initially isotropic extinction of glass containing spherical particles to a dichroic sample behavior in the irradiated area. This observation is interpreted as ultrafast particle deformation induced by the laser pulse creating nonspherical particles of uniform orientation. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1041
    Keywords: Key words Cyclosporin A ; Diltiazem ; Kidney transplantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: Bilateral cyclosporin A (CsA) and diltiazem pharmacokinetic interactions have previously been investigated, however, not with the new microemulsion preconcentrate formulation of CsA (Sandimmun Neoral). In addition, the pharmacokinetic effects on the pharmacological active metabolites of diltiazem have not previously been investigated. We performed a pharmacokinetic interaction study in renal transplant recipients, measuring both unmetabolised CsA and diltiazem in addition to three of the main metabolites of diltiazem (MA, M1, M2). Methods: Nine CsA-treated renal transplant patients were treated with diltiazem, 90–120 mg b.i.d., for 4 weeks. Pharmacokinetic investigations were performed both before and at the end of the diltiazem treatment period. Six non-CsA-treated renal transplant patients served as controls of CsA interactions with diltiazem and its metabolites. Results: Diltiazem treatment resulted in a significant mean increase in the area under the concentration–time curve (AUC) for CsA of 51(8)% (P 〈 0.008) and a peak concentration (Cmax) of 34(8)% (P 〈 0.05), without altering time to peak concentration (t max). CsA, however, did not significantly influence diltiazem pharmacokinetics, though two of the metabolites (M1 and M2) tended to be increased. Conclusions: Diltiazem interacts significantly with the pharmacokinetics of CsA in the new microemulsion formulation. Microemulsion-formulated CsA, however, did not show significant interaction with diltiazem pharmacokinetics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 55 (1999), S. 527-532 
    ISSN: 1432-1041
    Keywords: Key words Ascorbic acid ; Chronic renal failure ; Haemodialysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objective: Patients with renal disease receiving dialysis therapy are susceptible to a deficit in ascorbic acid (AA) caused by loss during dialysis and a restricted dietary AA intake. In previous studies, in such patients, the methods generally used for AA determination are non-specific and insensitive, and control of the easily deteriorating AA in the samples is often disregarded. The purpose of this work was to study the AA plasma levels and dialyser clearances as well as the kinetics of administered AA in a group of dialysis patients, using selective and sensitive methodology and a procedure preserving the AA sample content. Methods: Using an analytical method based on high-performance liquid chromatography and electrochemical detection, we have examined the dialyser clearance of AA as well as the pre- and post dialysis plasma levels of AA in patients on chronic dialysis therapy. The plasma AA levels were further measured after single and multiple dose supplementation of 200 mg p.o. per day. Results: The majority of the patients (16 of 19) had pre-dialysis plasma levels below the normal range. The dialyser clearance of AA was 212 ml/min (median value). Following dialysis, the plasma AA concentrations were reduced by a median of 33%. AA supplementation significantly increased these levels; however, they dropped soon after supplementation was stopped. AA in uraemic whole blood and plasma was, on average, less stable than in samples from healthy subjects. Conclusion: This study, using selective analytical method with adequate stability control, confirms that AA is readily removed by conventional haemodialysis membranes. Patients on chronic haemodialysis have remarkably low plasma AA levels unless given AA supplementation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1084
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Iodixanol (Visipaque, Nycomed Imaging AS, Oslo, Norway), an isotomic, dimeric and non-ionic contrast medium (CM), and iohexol (Omnipaque, Nycomed Imaging AS, Oslo, Norway), a low-osmolar, monomeric and non-ionic contrast medium, were used as glomerular filtration rate (GFR) markers in patients with severely impaired renal function. Different methods for determining GFR were compared. A total of 16 patients with s-creatinine 〉 400 μmol/l were enrolled in the study; 8 in each CM group. Serum-iodine was measured, and plasma CM clearance was determined using the Bröchner-Mortensen method, the single-sample method and conventional method. The ratios between the results obtained from the conventional method and each of the two other methods were calculated. These data were plotted against the mean of the pairs compared, and the upper and lower limits of agreement were calculated as the mean ratio ± 2SD. The comparison showed a high degree of agreement between methods, and the two simpler methods seem to be good alternatives to the conventional method, which gave good estimates of GFR (vs that determined by means of renal 125I-iothalamate clearance) when 24-h blood samples were included. However, slight overestimations of GFR, due to extrarenal excretion of the CM, were observed. In summary, serum clearance of iodixanol, as determined by the Bröchner-Mortensen method or single-sample method seems to be a simple and accurate marker of GFR in patients with severely reduced renal function. The findings obtained with iodixanol were similar to those obtained with iohexol.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1084
    Keywords: Contrast media ; Comparative study ; Intravenous digital subtraction angiography ; Iodixanol ; Iopamidol ; Kidney function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Iodixanol (visipaque, 320 mgI/ml) was compared with iopamidol (Solutrast, 370 mfI/ml) in a double-blind, randomized, parallel group, intravenous DSA phase-III trial for evaluation of safety and efficacy. A total of 117 patients received iodixanol (n = 60) or iopamidol (n = 57). Diagnostic efficacy was evaluated using categoric and visual analogue scales. Discomfort and adverse evenets were recorded. A total of 39 patients collected urine up to 72 h after the examination for analysis. Diagnostic efficacy and radiographic density were similar in both groups. Discomfort was milder with iodixanol. The difference between the frequency of adverse events between both groups (iodixanol = 7, iopamidol = 2) was without statistical significance. Creatinine clearance was slightly more affected by iodixanol, whereas the increase in renal excretion ofN-acetyl-beta-glucosaminidase (NAG) in the first 24 h collection period after the examination was significantly higher (p 〈 0.01) with iopamidol. Iodixanol was of equal diagnostic efficacy compared with iopamidol despite its reduced iodine content. Both contrast media are well suited for IV DSA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 71 (1999), S. 1066-1066 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...