Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Gefässchirurgie 2 (1997), S. 119-120 
    ISSN: 1434-3932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-3932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 352 (1980), S. 618-618 
    ISSN: 1435-2451
    Keywords: High frequency position finder ; Removal of metallic implants ; Osteosynthesis ; Hochfrequenz-Ortungsverfahren ; Metallentfernung ; Osteosynthese
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Entfernung einzeln liegender Osteosyntheseimplantate kann durch anatomische Lage, Narben oder Callusbildung im Operationsgebiet erschwert sein. Durch ein von uns entwickeltes HochfrequenzOrtungsverfahren ist die intraoperative Lokalisation möglich. Dabei wird die Veränderung eines Magnetfeldes durch Wirbelströme in Metallkörpern als Meßprinzip benützt. Die entwickelte Meßsonde hat die Größe eines Kugelschreibers, ist sterilisierbar und damit intraoperativ anwendbar. Sie reagiert auf Annäherung an einen Metallkörper durch änderung der Tonfrequenz. Vorteil des Geräts ist eine verkürzte Operationszeit, geringere Gewebstraumatisierung und geringere Röntgenstrahlenbelastung.
    Notes: Summary The removal of separate osteosynthetic implants can be hampered by anatomic situation, scars or callus formation in the operative area. We developed a new high frequency position finder which facilitates intraoperative localization. Principle of the procedure is the alteration of a magnetic field by whirling currents. Our newly developed probe is as small as a pencil, can be sterilized and thus be used intraoperatively. In approaching a metallic body, it reacts by alteration of its acoustic frequency. The great advantage of this instrument is shortening the operating time, lowering trauma to the tissue and reducing exposure to X-ray.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 369 (1986), S. 861-862 
    ISSN: 1435-2451
    Keywords: Central vein ; Doppler ultrasonography ; Puncture ; Complications ; Dopplersonographie ; Zentrale Venenpunktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wurde untersucht, ob die Lokalisation der V. jugularis int. oder V. subclavia durch Dopplerultraschall die Punktion dieser Venen erleichtert bzw. die Komplikationsrate senkt. Bei 92 Patienten wurden 115 Punktionen durchgeführt (91 x v.j.i., 24 x v.s.). Bei 15 Patienten waren zuvor auf anderen Abteilungen erfolglose Punktionsversuche vorausgegangen. Die Punktion gelang in 114 Fällen ohne Auftreten von Punktionskomplikationen. Bei einem Patienten ließ sich dopplersonographisch kein Venensignal ableiten. Die Technik hat sich, insbesondere bei schwierigen Punktionsbedingungen bewährt.
    Notes: Summary Does the localization of the internal jugular (IJV) or subclavian (SV) vein by means of Doppler ultrasonography facilitate the puncture of those veins and reduce the complication rate? We performed 115 punctures in 92 patients (91 x IJV, 24 x SV) by this method. Of these patients, 15 were referred to our unit because of previous unsuccessful punctures. The puncture and insertion of the central venous catheter were performed without complication in 114 cases. In one patient we were not able to record a signal from either the IN or SV. This technique of Doppler-monitored venous puncture is especially recommended for difficult anatomic situations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-2451
    Keywords: Temporary liver ischaemia ; Changes in clotting system ; Animal experiments, hepatolysis ; Temporäre Leberischämie ; Gerinnungsveränderungen ; Tierexperiment ; akuter Leberzerfall
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Im Tierexperiment wurden an Schweinen mit dem Modell der temporären Leberischämie nach Misra Änderungen des Gerinnungssystems untersucht. 24 bzw. 48 h postoperativ nach Leberskelettierung und Anlage eines portocavalen Seit-zu-Seit-Shuntes wurde über 90 bzw. 180 min durch Occlusion der Arteria hepatica und der Venae portae am wachen Tier eine temporäre Leberischämie erzeugt. Prä- und postischämisch wurden zahlreiche Gerinnungsfaktoren — sowie Thrombocytenfunktionsuntersuchungen durchgeführt. Die gemessenen Werte deuten auf das Ablaufen einer disseminierten intravasalen Gerinnung hin. Die Veränderungen sind zur Überprüfung therapeutisc Vorstellungen zu gering ausgeprägt, so daß eine weitere Verlängerung der Zeit der temporären Leberischämie sinnvoll erscheint.
    Notes: Summary Changes in the clotting system have been studied in animal experiments on pigs according to MISRA's model of temporary liver ischaemia. A temporary liver ischaemia was induced on non-anaesthetized animals 24 to 48 h after dissection of the liver and application of a portocaval side-to-side shunt by occlusion of the hepatic artery and portal vein for 90 and 180 min. General clotting factors as well as studies on thrombocytic function were performed before and after ischaemia. The resulting values point at disseminated intravascular coagulation, but its alterations are too small for a critical evaluation of therapeutic models. Thus, a further prolongation of the temporary liver ischaemia seems to be of value.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1435-2451
    Keywords: Isolated tibia fractures ; Lower limb fractures ; Fibula resection osteotomy ; Isolierte Tibiafrakturen ; Unterschenkelfrakturen ; Fibularesektionsosteotomie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Experimentell wurde an Leichenknochen eine Elastizität der Fibula nachgewiesen, die eine klinisch bedeutsame Sperrwirkung der Fibula unwahrscheinlich macht. Die Nachuntersuchung von 83 Patienten mit 11 isolierten Tibiafrakturen and 72 Unterschenkelfrakturen, bei denen prophylaktisch bzw. bei sich abzeichnender verzögerter Knochenbruchheilung eine Fibularesektionsosteotomie durchgeführt wurde, zeigte keine Verkürzung der Konsolidierungsdauer and keine Verkleinerung des Frakturspaltes im Röntgen-bild, die als Folge einer aufgehobenen Sperrwirkung zu deuten ware. Aufgrund dieser Ergebnisse erscheint die Indikation zur FRO zweifelhaft.
    Notes: Summary In an experimental study on bones from corpses the fibula was found to be highly elastic. This makes any clinically important stoppage effect of the fibula improbable. The effectiveness of fibula resection osteotomy (FRO) was investigated in a clinical study on 83 patients (11 isolated tibia fractures, 72 lower limb fractures). It could not be shown that FRO reduces the healing time of the fractures, nor could a tightening of the fracture gap be seen in X-ray pictures. On the basis of these results FRO does not seem to improve the healing of lower limb fractures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 349 (1979), S. 619-619 
    ISSN: 1435-2451
    Keywords: Bowel sounds ; Intestinal motility ; Postoperative intestinal atony ; Darmgeräusch ; Darmmotilitdt ; Postoperative Darmatonie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Zwischen elektromyographischen Ableitungen der Darmwand und Darmgeräuschen ist, wie wir in einigen Versuchen zeigen konnten, eine Korrelation nachweisbar. Damit werden Darmgeräusche zu leicht meßbaren Parametern der Darmmotilität. In einigen experimentellen Untersuchungen konnte aufgrund der Darmgeräuschanalyse gezeigt werden, daß die postoperative Darmatonie mittels medikamentöser Behandlung (Dihydergot, Prostigmin) verkürzt werden kann. Bei klinischen Messungen wurden entsprechende Ergebnisse erhalten.
    Notes: Summary It was demonstrated in experimental studies that there is a correlation between intestinal EMG and bowel sounds. Therefore the measured bowel sounds indicate the state of intestinal motility. In an experimental study the analysis of bowel sounds showed that postoperative intestinal atony is shortened by drug treatment (Dihydergot, Prostigmin). Clinical data corroborate these results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 342 (1976), S. 621-621 
    ISSN: 1435-2451
    Keywords: Hip ; Bone cement ; Embolism, fat ; Knochenzement ; Hüfte ; Fett ; Embolie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Durch das Einpressen von Knochenzement in den Markraum des Oberschenkelknochens, kommt es zu akuten Drucksteigerungen. Die Folge ist eine Mark- und Fettintravasation, welche zu einer mechanischen Blockade der Mikrozirkulation in der Lunge führt. Ebenso kommt es auch zum Übertritt von thromboplastischen Substanzen. Eine rechtsventrikuläre Ausflußblockade, die zum akuten Cor pulmonale führen kann, ist möglich. Als prophylaktische Maßnahme, Druckausgleich im Markraum durch Drainage und Sog, sowie die Anwendung eines natürlichen Proteinaseninhibitors Aprotinin zur Hemmung des Thrombocytensturzes wird empfohlen.
    Notes: Summary The pressing of bone cement into the medullary space of the femur causes acute presure increases. The consequence is a marrow and fat intravasation leading to mechanical blocking of the microcirculation in the lung, which also entails the transfer of thromboplastic substances. A ventricular obstruction of the outflow is possible. As a prophylactic measure, pressure compensation within the medullary space by means of drainage and suction is recommended, as is the application of the natural proteinase inhibitor aprotinin to prevent a fall in the platelet count.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Gefässchirurgie 4 (1999), S. 67-69 
    ISSN: 1434-3932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Gefässchirurgie 5 (2000), S. 62-63 
    ISSN: 1434-3932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...