Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1468-2494
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A multicentre study for measuring skin hydration with 349 volunteers was carried out in six different laboratories. The purpose of the study was to investigate physical-, physiological- and product-dependent parameters of three test emulsions (base, base + moisturizer and base + moisturizer + lipids) in a double-blind study. A comparison between analogous and digital sensor technology of the Corneometer CM825 was examined. Here, a clear relationship between both sensor types could be highlighted. A vital point of the study was the division of the test subjects according to their skin type. To get more objective limits for three different skin types – very dry, dry and normal skin – visual expert evaluation, self-assessment and hydration measurements were analysed by means of statistical methods. The moisture-related skin types were determined as follows: very dry skin was characterized with corneometer units below 30, dry skin between 30 and 40 and normal skin higher than 40 a.u. (arbitrary units). The efficacy of the three test emulsions was examined in relation to the mentioned skin types. Analysing the measured data of all test centres, a clear dependency of skin physiology (skin type) and product efficacy became evident. The drier the skin, the higher the increase of hydration. The product performance of the three test emulsions compared to the untreated control resulted in a significant increase of skin hydration in all measuring centres. The evaluation of a product ranking showed a good differentiation between the basic emulsion and the two other products. An increase of efficacy by adding lipids could be observed in four of six centres. The important influence of the skin type of the volunteers on the degree of product performance, as demonstrated in this study, should be especially considered when drawing up guidelines for efficacy testing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1468-2494
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of our studies was to verify efficacy and skin compatibility of a medical face care system containing 2% lactic acid (LA) as active ingredient in a specially designed vehicle (Follicle Targeting System) in adult subjects with mild acne vulgaris. The first study (46 patients) demonstrated superiority of 2% LA in comparison to 2% salicylic acid with respect to number of comedones and inflammatory lesions. The second study evaluated 90 patients receiving distinct combinations of face care products (Eucerin® Impure Skin, Hamburg, Germany), i.e. cleansing gel, facial tonic (2% LA) and cream gel (2% LA). All treatments were performed twice daily over a 12 weeks period. Lesion counts, cyanoacrylate biopsies and determination of quality of life by questionnaires were performed at different timepoints. A reduction of comedones by 56% corresponding to an 46% increase of quality of life index was demonstrated in patients applying cleansing gel, facial tonic and cream gel. For the first time we were able to show a significant improvement concerning the quality of life after using a new face care line. Especially adults with mild forms of acne may benefit from this effective skin care regimen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1468-2494
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Standardization of the method to determine sun protection factors (SPF) is fundamental to uniform labelling of SPF values on sun products. The COLIPA Task Force ‘Sun Protection Measurement’(SPM), including representatives of major European sun-product manufacturers and contract testing laboratories, was established in 1990 to define methods for sun products testing. The process involved in developing the COLlPA SPF Test Method started with a critical appraisal of previously existing methods, and identification of areas for improvement. Experiments were performed by the participating laboratories to establish the new recommended test protocol which was then confirmed in two multicentred ring tests. Improvements to test methodology included the number and selection of volunteers and skin types, the application of the product, the definition of W output from solar simulators, and the method for assessing erythemal response (MED) including an option to use colorimetry to define objectively the ‘erythemal threshold’ of skin and to predetermine MED prior to exposure. Four cosmetic formulations and neutral density physical filters (SPF from 4 to 20) were tested in two ring tests. Results showed that variations in SPF of the cosmetic products were, on average, directly proportional to SPF value. An excellent correlation was found between visual and colorimetric SPF assessments (r = 0.99). An acceptable range of values for low and high SPF standard products was also established. The COLIPA SPF test method is now fully defined and supported by experimental data. Its use will harmonize SPF testing throughout Europe and help in the quest for global harmonization in testing sun products.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Skin research and technology 6 (2000), S. 0 
    ISSN: 1600-0846
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background/aims: In moist intertriginous regions, such as the armpit, the pH value is physiologically higher than in other skin regions. The regulation of the axillary pH-value was examined in an open study with 48 subjects in three groups with n=16 each.Methods: In the first 10 days (run-in) the subjects received a standard treatment in the axilla with shaving, cleansing and application of a pH-neutral deodorant. This was followed by a 5 day treatment period with the three test products (pH5 Eucerin® Deodorant Roll-on, Deodorant Balsam Spray, Deodorant Cream). The study was concluded by a wash-out period with procedures identical to the run-in phase. The pH was measured with a calibrated pH-meter.Results: A significant pH reduction was shown during the treatment period when compared to the run-in phase. The Deodorant Roll-on induced a reduction of the mean pH values from 6.1 to 5.3, the Deodorant Balsam Spray from 6.5 to 5.7 and the Deodorant Cream from 6.2 to 5.3. During the wash-out period all pH values returned to baseline.Conclusion: All of the deodorants tested demonstrated a significant reduction in axillary pH. There is evidence that a high skin pH promotes the growth of several microorganisms that produce malodor. Therefore, the regulation of pH may contribute to the deodorant efficacy of the test products.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...