Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 117 (1974), S. 145-158 
    ISSN: 1432-1076
    Keywords: Visual perception ; Frostig test ; Defects of visual perception ; Brain damage ; Intelligence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Aus einem Kollektiv von 330 Kindern, das im Rahmen eines Screening-Verfahrens hinsichtlich Intelligenz und psychomotorischer Entiwicklung voruntersucht war, erreichten 86 in dem motorischen Test (Lincoln-Oseretzky-Skala) nicht die Punktzahl, die dem Mittelwert des Kollektivs entsprach. Von ihnen boten bei der anschließenden neurologischen Untersuchung 29, deutliche, Auffälligkeiten, 57 waren neurologisch unauffällig. Diese 29 bzw. 57 Kinder im Alter von 5;10 bis 7;9 Jahren sowie eine Kontrollgruppe von 46 gleichaltrigen Kindern wurden mit dem “Developmental Test of Visual Perception” (Frostig) untersucht. Komplexe Perzeptionsstörungen mit einem Perzeptionsquotienten (PQ) unter 90 fanden sich bei den neurologisch auffälligen Kindern mit 28% mehr als doppelt so häufig wie in den beiden anderen Gruppen. Als Ursache für das Vorliegen visueller Perzeptionsstörungen kommt also in erster Linie eine Schädigung des Zentralnervensystems in Betracht. Auffallend war jedoch der relativ hohe Anteil von Perzeptionsstörungen auch bei den neurologisch unauffälligen Kindern (12%) bzw. in der Kontrollgruppe (13%). Neurologisch auffällige Kinder waren in ihrer intellektuellen Entwicklung, gemessen mit der Columbia-Mental-Maturity-Scale, gegenüber neurologisch unauffälligen Kindern deutlich retardiert. Gleichzeitig bestand ein enger Zusammenhang zwischen Störungen der geistigen Entwicklung und Störungen der visuellen Perzeption. Über den Kausalzusammenhang können allerdings keine Aussagen gemacht werden. Wahrscheinlich spielt der Faktor Intelligenz bei den neurologisch unauffälligen Kindern eine geringere Rolle hinsichtlich visueller Perzeptionsstörungen. Bei den neurologisch auffälligen Kindern muß vor allem dann mit visuellen Perzeptionsstörungen gerechnet werden, wenn sie gleichzeitig in ihrer geistigen Entwicklung beeinträchtigt sind.
    Notes: Abstract 86 children aged 5.10 to 7.9 years with an abnormally low score in developmental screening tests and 46 age-matched controls were evaluated with the Frostig “Developmental Test of Visual Perception”. The probands were divided into two subgroups (A) 29 children with neurologic abnormalities and (B) 57 children without. 28% of the probands in subgroup (A) had multiple perceptual defects against 12% in subgroup, (B) and 13% in the control group. The statistical correlation of neurologic abnormalities and visual perception defects suggests a causal relationship. However, the relatively high frequency of visual perception defects in neurologically normal children was remarkable. The Columbia Mental Maturity Scale showed the intellectual performance of neurologically abnormal children to be impaired as compared to children with normal neurologic findings. Within the groups, developmental retardation and defects of visual perception were closely related. Again, this suggests, but does not prove, a causal relationship. Since the intelligence defect was less apparent in neurologically normal children, our data suggest that defects of visual perception are most likely to occur in children with a combined disorder, of intellectual and neurologic function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 212 (1979), S. 49-54 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Prinzipien für Längenmessungen am Augenhintergrund werden gegenübergestellt. Die Meßprinzipien werden hinsichtlich einer minimalen Meßunsicherheit diskutiert. Die Längenmessungen mittels Photographie und optischer Versetzung des Meßobjektes gegen sich selbst lassen die geringste Meßunsicherheit erwarten. Dabei werden die Meßunsicherheit am idealisierten Meßobjekt und der Fehlereinfluß von Meßobjektbewegungen als wesentliche, die Meßprin/ipien unterscheidende Fehlerquellen berücksichtigt.
    Notes: Abstract Comparison of principles is presented for length measurements at the fundus of the eye and discussed with respect to minimum measuring errors. Measurements by photography or by optical dislocation of the measuring object to itself are the methods with the least uncertainty under the conditions taken into consideration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 217 (1981), S. 137-142 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Mit Hilfe der Gefäßweitenmessung und der 2-Punkte-Fluorometrie wird das Blutvolumen pro Zeiteinheit (Blutvolumendurchfluß) in retinalen arteriellen Gefäßstücken gemessen. Es zeigt sich, daß bei Venenastverschlüssen nach Lichtkoagulation die retinale Zirkulation im betroffenen Areal gegenüber nicht ausreichend koagulierten Gebieten reduziert ist.
    Notes: Abstract The blood flow through the great retinal vessels is defined by the help of two-point photometry and measuring of the diameter of the vessel. In branch vein occlusion the retinal circulation, in affected areas is reduced after photocoagulation compared to insufficient coagulated areas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 204 (1977), S. 113-123 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Untersucht wurden Auftreten und Verhalten von komplementbindenden Anti-Kaninchen-ROS-Antikörper im Serum von GrCh-Kaninchen nach ein- oder zweimaliger intracutaner Applikation retinaler Antigene in komplettem Freundschen Adjuvans (KFA). Die Wirkungen von 14 Antigen-Varianten aus heterologen, homologen und autologen Netzhaut-Komponenten in KFA wurden geprüft und verglichen. Mit Ausnahme des Überstandes eines zentrifugierten Homogenisats homologer Retina bewirkten alle übrigen Immunogene generell das Auftreten von Anti-ROS-Antikörpern. Die niedrig bleibenden Titer-Maxima waren 4 bis 8 Wochen post injectionem überschritten. Die Titer-Bewegungen zeigten Beziehungen zur Qualität und Dosierung der Immunogene. Boosterungseffekte nach Reinjektion erreichten ihr Maximum bereits nach 5 bis 14 Tagen. Tiere, die keine Chorioretinitis-Herde ausbildeten, hatten öfter höhere Antikörper-Titer als Kaninchen mit klinisch festgestellter Erkrankung. Unter der Voraussetzung entsprechender Relevanz der beobachteten humoralen Reaktion haben die nachgewiesenen komplementbindenden Antikörper gegen homologe ROS eher protektive als pathogene Funktion.
    Notes: Summary The authors studied the appearance and behavior of complement-fixing anti-ROS antibodies in the sera of GrCh rabbits following one or two intracutaneous injections of retinal antigens emulsified in Freund's complete adjuvant (KFA). Fourteen different antigenic preparations from heterologous, homologous, and autologous retinal components incorporated in KFA were tested and compared. Apart from the supernatant of a centrifuged homogenized preparation of homologous retina, all immunogens generally induced anti-ROS antibodies. The antibody titers (reciprocal values) reached a maximum 4 to 8 weeks post injection, at only low levels. The changes in antibody concentrations showed some relationship to the quality and dose of the immunogens. Anamnestic effects following reinjection reached maximum values within as little as 5 to 14 days. Animals not developing chorioretinitic lesions showed higher antibody titers more frequently than rabbits with clinically confirmed disease. Provided there is sufficient relevance of the humoral reactions observed, the complement-fixing antibodies we found in our experiments are more likely to have protective than pathogenic functions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In seven diabetics of type 1 and seven of type 2, the flow physiologic magnitudes were measured in a retinal quadrant before and after photocoagulation. The segmental blood flow, the arterial flow velocity, and the diameters of artery and vein are smaller after photocoagulation than before. Investigations into the time course of the flow-physiologic parameters following photocoagulation show that the flow-physiologic values are stationary about 2 weeks after photocoagulation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 212 (1979), S. 41-47 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird eine kombinierte Meßeinheit für das Retinophot beschrieben, mit der sowohl Längenmessungen, als auch Indikatorlaufzeitmessungen an großen retinalen Gefäßen des Menschen durchgeführt werden können. Somit ist es möglich, den Blutvolumendurchfluß in großen retinalen Gefäßstücken zu ermitteln. Die Indikatorlaufzeitmessung wurde auf der Basis der Zwei-Punkte-Photometrie realisiert. Das Prinzip der Längenmessung beruht auf der Planplattenmikrometrie. Erste Meßergebnisse werden vorgestellt.
    Notes: Abstract A combined measuring unit for the Retinophot is described which can be used to determine the blood flow through the great retinal vessels. This method is possible by combination of the two-point photometry with length measurements by means of rocking-plate micrometry. The first measuring results are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 212 (1979), S. 109-115 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird eine Meßeinheit als Zusatzeinheit für Ophthalmoskope beschrieben, mit der Längenmessungen am Augenhintergrund durchgeführt werden können. Das Meßprinzip beruht auf der optischen Versetzung des Meßobjektes gegen sich selbst. Die optische Versetzung der Bildpunkte wird durch eine kippbare Planplatte in der Okularzwischenbildebene des Ophthalmoskops realisiert. Die Bildpunktversetzung wird auf eine Meßbewegung zurückgeführt, die eine für den Anwendungsfall ausreichend lineare Meßbeziehung liefert.
    Notes: Abstract An additional unit which can be used for length measurements at the fundus of the human eye is described for the ophthalmoscope. The principle of measurement is based on optical displacement of the measuring object to itself. The optical displacement of picture points is made possible by the use of a tilting flat glass plate in the intermediate image plane of the eyepiece. The relation between the optical displacement of picture points and the measuring movement is sufficiently linear for the described device.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 224 (1986), S. 179-183 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Blood flow, arterial velocity, and vascular diameter were measured in patients with retinal vessel occlusion before and after treatment, especially after light coagulation. The mean values in the patient group showed significantly reduced blood flow and velocity compared to the normal group. The mean group difference before and after therapy revealed that while there is an increase in blood flow after treatment, the normal value is not reached. Individual patient values indicated both increased and decreased blood flow and velocity after treatment as compared with the values before therapy. There are various stages in microcirculatory disease and the microcirculation also behaves differently after treatment, which could be observed by measurement in vivo of the physiological flow parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 354 (1996), S. 829-832 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A computer-program “IR-Spectroscopy” for the interpretation of infrared spectra of organic compounds is described. It contains the following basic items for preprocessing and execution of the computer based interpretation process: handling of the rule-base CorTab, routines for automatic rule generation and interpretation modules on the basis of the programming languages PROLOG and C.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Gold- und Silberionen können in wäßriger Lösung mittels Zinnoxidhydrat gefällt und nach Zugabe von 2-Phenylethylenphosphonsäure sowie Reagentien zur Schaumbildung durch Flotation leicht abgetrennt werden. Nach der Anreicherung kann durch Flammenabsorptionsspektrometrie eine quantitative Gehaltsbestimmung durchgeführt werden. Extraktion des Analyten mit i-Amylalkohol schaltet den Störeinfluß von Schwermetallionen bei der Goldbestimmung aus. Nach Flotation aus 1 l Lösung können Gehalte von ng · ml−1 ausreichend sicher und richtig bestimmt werden.
    Notes: Summary Gold and silver ions can be precipitated in aqueous solutions by means of stannic hydroxide and after addition of 2-phenylethylene phosphonic acid and foaming agents be easily separated by flotation. After enrichment a quantitative analysis can be carried out by flame atomic-absorption spectroscopy. The disturbing influence of heavy metal ions in gold assaying is eliminated by the extraction of the substance to be analyzed by means of i-amyl alcohol. After flotation of 1 l solution contents of ng · ml−1 can be analyzed with sufficient accuracy and precision.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...