Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 404 (1983), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 1 (1948), S. 338-339 
    ISSN: 0001-5520
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 12 (1973), S. 160-164 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Zusammenfassung Für die mikropolare Flüssigkeit nachEringen (3, 4) werden die Grenzschichtgleichungen abgeleitet. Diese Flüssigkeit ist dadurch gekennzeichnet, daß die Bewegung ihrer Elemente durch zwei kinematische Felder gegeben ist, das Geschwindigkeits- und das Spinfeld. Für die Staupunktsströmung als Außenströmung kann man eine Ähnlichkeitslösung der Grenzschichtgleichungen angeben. Für das Strömungsverhalten der polaren Flüssigkeit erweisen sich zwei Parameter als wesentlich: Das Verhältnis von Grenzschichtdicke zu charakteristischer Abmessung des Fluidelements sowie ein Parameter, der die Kopplung zwischen Geschwindigkeitsfeld und Spinfeld wiedergibt. Die Lösung der Grenzschichtgleichungen wird diskutiert, wobei die Strömungseigenschaften von polarer undNewtonscher Flüssigkeit einander gegenübergestellt werden.
    Notes: Summary The micropolar fluid defined by the constitutive equations ofEringen (3, 4) is to be considered. This fluid is characterized by describing the motion of the fluid elements by two kinematic fields: The velocity field and the spin field. The corresponding equations of motion are specialized for boundary layer flow. A similar solution can be given for “flow near stagnation” as outer flow. Concerning the flow properties of the polar fluid two parameters are of main interest: First, the ratio of boundary layer thickness to characteristic length scale of the fluid elements; secondly, a parameter describing the coupling between velocity and spinfield. The solution is discussed comparing the behaviour of the micropolar fluid to that of aNewtonian liquid.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 14 (1975), S. 258-263 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Zusammenfassung Polare Fluide werden in viskosimetrischer Strömung durch drei Stoffkonstanten gekennzeichnet. Es wird gezeigt, daß diese Stoffkonstanten nur durch Variation der Meßgeräte-Geometrie bestimmt werden können. Die Abhängigkeit der gemessenen Schubspannungswerte von der Schergeschwindigkeit ist linear. Es treten bei viskosimetrischer Strömung keine Normalspannungsdifferenzen auf. Die Abweichung vomNewtonschen Verhalten wird durch den sog. Kopplungsparameterκ v und den Quotienten aus den charakteristischen Längen von Strömungskonfiguration und Mikrostruktur bestimmt. Das Verhalten des polaren Fluids geht in dasjenige desNewtonschen über, wenn der Kopplungsparameter nach Null geht, oder wenn die charakteristische Länge der Mikrostruktur gegenüber der Strömungsgeometrie beliebig klein wird. Es wird auf Messungen verwiesen, deren Fließeigenschaften mit Hilfe der Theorie des polaren Fluides dargestellt werden können. Dazu gehören Latices, Emulsionen, Suspensionen mitc v 〈 0,25, Lösungen von Polymeren in niedermolekularen Lösungsmitteln. Als maßgeblich für die Länge der Mikrostruktur wird eine Größe angenommen, die von der linearen Abmessung des suspendierten Partikel und der Konzentration abhängt. Bei den genannten Medien tritt oberhalb einer Partikelabmessung von etwa 10 µm kein Einfluß der Partikelgröße auf. Daraus folgt, daß die geschilderten Effekte im Meßgerät nur bei sehr kleinem Kapillarradius bzw. sehr kleiner Spaltweite zu beobachten sind.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 196 (1931), S. 335-336 
    ISSN: 0863-1786
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Acta mechanica 25 (1977), S. 241-256 
    ISSN: 1619-6937
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Summary Fluid is fed into a chamber at the periphery with a non-vanishing tangential velocity component. Thus the streamlines of the time averaged motion are spirals. In the center of the chamber the fluid emerges axially. Assuming that the chamber height is small compared to the diameter the velocity distribution and pressure distribution, respectively, are calculated by means of an integral technique. The energyloss was determined. One obtains a simple relation proved by experimental data.
    Notes: Zusammenfassung Einer Kammer wird am Umfang ein Strömungsmedium mit nichtverschwindender, tangentialer Geschwindigkeitskomponente so zugeführt, daß die Stromlinien für die zeitlich gemittelte Bewegung einen spiraligen Verlauf annehmen. Im Kammerzentrum tritt das Strömungsmittel axial aus. Für den Fall, daß die Kammerhöhe gegenüber dem Durchmesser klein ist, werden Geschwindigkeits-und Druckverteilung mit Hilfe eines Integralverfahrens berechnet. Weiterhin wird der Energieverlust der Kammerströmung bestimmt. Es ergibt sich eine einfache Beziehung, die durch Messungen bestätigt ist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1955
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Hamster peritoneal macrophages were infected with arivulent and virulent promastigotes of aL. donovani strain using various ratios (1∶1; 1∶10) of parasites and peritoneal cells. Light microscope studies have shown that there was a significant difference in the number of parasites taken up by phagocytic cells between the macrophage cultures infected with avirulent and virulent promastigotes at 4 h as well as during the following 14 days of infection. In both virulent groups the number of amastigotes were sharply increased. However, the surviving parasites were eliminated continuously when the macrophage cultures were infected with avirulent parasites. Electron microscope examinations of the different infected macrophage cultures did not show any difference in the localization of the surviving parasites. At one and 24 h post-infection, parasites have been observed in typical parasitophorous vacuoles. However, by day 4, 7, and 14 post-infections, the majority of intact parasites were surrounded by a four-laminar membrane without a space between parasite and vacuole membrane. Besides, some amastigotes were seen in large parasitophorous vacuoles. It seemed as if some of these amastigotes were trying to leave the parasitophorous vacuoles. In all cases acid phosphatase could be demonstrated in the parasitophorous vacoules and around the parasites indicating that the lysosomes of the host cell have been fused with the parasitophorous vacuole. It is indicated that the virulentLeishmania parasites are more resistant to the digestive system of the macrophages.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 69 (1997), S. 1260-1260 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 70 (1998), S. 1181-1181 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...