Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1203
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Evidence from cDNA cloning has shown that calcitonin receptors (CTRs) have seven potential transmembrane domains. In this study, structural analysis of CTRs from ten cultured human tumor cell lines and 117 human blood samples demonstrated allelic variants at the 1377th nucleotide in intracellular domain 4, expressing either proline or leucine as the 463rd amino acid. It was found that the variant with proline at this site was the more prevalent type of CTR among the Japanese population.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Heat stroke ; Multiple organ dysfunction syndrome ; Blood purification therapy ; Continuous venovenous hemofiltration ; Plasma exchange
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Five patients were admitted to our hospital because of classical heat stroke during the heat waves which attacked our country in the summers 1994 and 1995. The clinical and laboratory findings of all patients suggested the rapid progress of multiple organ dysfunction syndrome (MODS). Blood purification (BP) therapy, in addition to conventional treatment, was performed in three of the patients. Despite their disastrous general condition, all completely recovered or recovered sufficiently to be transferred to a rehabilitation hospital. Two additional patients were treated with conventional treatment only and both died in 1–3 days after admission.Clinical characteristics and laboratory findings on admission showed no differences between the cases receiving BP therapy and those not receiving BP therapy. These findings suggest that, in heat stroke patients, additional BP therapy may provide a better prognosis than conventional therapy only. These beneficial effects of BP may have been due mainly to the removal of proinflammatory cytokines related to heat stroke.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0983
    Keywords: Rhizopus niveus ; pyr4 ; Rhizopus delemar ; Transformation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract We have cloned a pyr4 gene encoding orotidine-5′-monophosphate decarboxylase of the filamentous fungus Rhizopus niveus. The pyr4 gene of R. nivens has an open reading frame composed of 265 amino-acid residues and has two putative introns. We have also isolated a pyr4 mutant of Rhizopus delemar from 5-fluoroorotic acid-resistant mutants and transformed it with the pyr4 gene of R. niveus as a selectable marker. Introduced DNA was integrated into the chromosome in a multiple tandem array. The mitotic stability of the introduced DNA was increased by a repeated sporulation process. The expression of the Escherichia coli β-glucuronidase gene in R. delemar was successfully obtained under the control of the pgk2 gene promoter of R. niveus by co-transformation with the pyr4 gene.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0942-0940
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 102 (1995), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In an open-label, multicentre, randomized, parallel group study, 164 women with endometriosis were assigned to treatment. Out of these women, 81 received danazol (600 mg daily for 8 weeks, then 400 mg for 16 weeks) and 83 were given gestrinone (2.5 mg twice a week for 24 weeks). Five weeks before the start of treatment clinical evaluation and diagnostic laparoscopy were performed during the screening visit. Drug assignment and laboratory data assessment were carried out within 3 days of the estimated onset of the menstrual cycle at baseline visit. The response to treatment was assessed during visits at weeks 2, 4, 8, 12, 16, 20 and 24; at the last visit a second laparoscopy was performed. Therapeutic efficacy was evaluated by analysis of the laparoscopic scores assessed according to the revised American Fertility Society classification. Symptomatic response was measured by clinical scores and laboratory data. In one centre, bone mineral density was also recorded. One patient in the danazol group discontinued treatment due to a cutaneous rash as a probable adverse reaction at the beginning of the study. The therapeutic efficacy of danazol and gestrinone did not differ significantly when the revised American Fertility Society scores were compared. The symptomatic response also showed no statistical difference when clinical examination scores were analysed. There was no significant difference between the drugs in laboratory data, including bone mineral density, with respect to adverse events. Analysis of clinical scores showed that danazol was superior to gestrinone with respect to acne and irregular bleeding. Based on these data, we conclude that both danazol and gestrinone are reliable in the treatment of endometriosis and offer similar results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high precision atomic polarimeter system for the use in beam-foil spectroscopy experiments with a few keV/amu heavy-ion beams has been developed. The polarimeter measures the circular polarization of fluorescences from the beam ion in-flight after the beam–foil interaction. The present system has two identical such polarimeters in both sides of the beam axis to reduce the systematic errors such due to the fluctuations of beam current, background and so on. A successful use of an ultrathin carbon foil (1.5 μg/cm2), which was durable for several hours against a few hundred nA beam irradiation, enabled the beam–foil experiments with such low energy heavy-ion beams. A performance test of the polarimeter system was carried out in the tilted foil experiments with a 1.7 keV/amu 14N+ beam. The atomic polarization was observed for the transition 1s22s22p3p 1D→1s22s22p3p 1P, whose fluorescence wavelength is 399.5 nm, in the N+ ion (N II). The polarization was approximately −2% for the tilt angle of −40° and showed monotone increasing with increasing tilt angle up to +2% for +40°. The polarization at 0° was (0.002±0.25)%, which is highly consistent with the expected polarization of 0%. This result indicates the high reliability of the present polarimeter system. This is the first tilted-foil experiment at such low beam energy. The present experimental technique will be very useful for studies of the polarization mechanism of the beam–foil interaction. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Ion distributions in a loss cone are measured in the GAMMA 10 tandem mirror [Phys. Rev. Lett. 55, 939 (1985)]. When Alfvén ion cyclotron (AIC) modes are excited in the central cell, enhanced end-loss of ions is observed for a characteristic energy region which agrees well with the resonant ion cyclotron condition with the AIC wave. From measurements of pitch angle distributions of end-loss ions, it is found that the loss cone is filled for this characteristic energy region, indicating an ion diffusion in a velocity space induced by the AIC wave. Magnitude of the observed additional end-loss increases with increase in the amplitude of the AIC modes. In the present experimental parameters in GAMMA 10, the AIC wave effect on the axial ion confinement is not serious. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 99 (1995), S. 875-878 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 73 (1998), S. 2325-2327 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Number of Cu atom(s) in the 1.014 eV copper center in silicon crystal was determined from an accurately measured relationship between the photoluminescence (PL) intensity of the center and Cu concentration in the crystal. For Cu concentrations lower than about 1×1014 atom/cm3, the PL intensity increased linearly with increasing Cu concentration. From this result and the law of mass action, it was concluded that the Cu center had only one Cu atom in it, contradicting the long-believed pair Cu model. Based on already published data and the present result, a structural model in which the Cu atom was bonded at the center of the Si–Si bond was presented for the Cu center. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 73 (1998), S. 3896-3898 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: In order to determine dissociation energy of the 1.014 eV photoluminescence (PL) Cu center in silicon crystal, decay of the PL intensity of the center by annealing samples at various temperatures was measured. The samples were prepared by contamination of Cu from Cu solution and heat treatment at 700 °C followed by rapid cooling to room temperature. From the temperature dependence of the time constant of the decay of the PL center, activation energy of dissociation of the center was obtained. The value was 0.47+±0.05 eV, which was much smaller than that (1.02 eV) obtained by the decay of the deep level transient spectroscopy Cu center peak at Ev+0.09 eV. The present value could reasonably explain the rapid thermalization of rearrangement of the centers after the release of stress which had been observed earlier. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...