Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1990-1994  (37)
  • 1985-1989  (23)
  • 1975-1979  (21)
  • 1
    Digitale Medien
    Digitale Medien
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 95 (1991), S. 1144-1150 
    ISSN: 1089-7690
    Quelle: AIP Digital Archive
    Thema: Physik , Chemie und Pharmazie
    Notizen: A simple model for van der Waals potentials presented earlier [J. Chem. Phys. 80, 3726 (1984)] has been extended to describe chemical bonds by including the exchange-dispersion term of Herring and Flicker. For H2, the 1Σ ground state potential is predicted in excellent agreement with the accurately known ab initio potential, the well depth being reproduced to within 0.6%. New two configuration self-consistent-field (SCF) calculations for the 1Σ and the 3Σ states of Li2 have made it possible to test the model for this system as well. Here the discrepancy is only 3% in the well depth for the 1Σ Li2 potential.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1089-7674
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Experiments to explore the long-time evolution of noninductive, high βp plasmas in the DIII-D tokamak [Plasma Physics and Controlled Nuclear Fusion Research, 1986 (International Atomic Energy Agency, Vienna, 1987), Vol. 1, p. 159], have identified a new, quiescent, high performance regime. The experiments were carried out at low current (400–800 kA) with medium power neutral beam injection (3–10 MW). This regime is characterized by high q0 ((approximately-greater-than)2) and moderate li(∼1.3). It is reached by slow relaxation of the current profile, on the resistive time scale. As the profiles relax, q0 rises and li falls. When q0 goes above 2 (approximately), magnetohydrodynamic (MHD) activity disappears, and the stored energy rises. Most dramatic is the strong peaking of the central density, which increases by as much as a factor of 2. The improved central confinement appears similar to the PEP/reversed central shear/second stable core modes seen in tokamak experiments, but in this case without external intervention or transient excitation. At high current, a similar, but slower relaxation is seen. Also notable in connection with these discharges is the behavior of the edge and scrape-off layer (SOL). The edge localized modes (ELM's) as seen previously, are small and very rapid (to 1 kHz). The SOL exhibits high density (≥1×1019 m−3), which shows little or no falloff with radius. Also the power deposition at the divertor surface is very broad, up to four times the width usually seen. This regime is of particular interest for the development of steady-state tokamak operating scenarios, for the Tokamak Physics Experiment (TPX), and following reactors.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 2101-2102 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: This note describes the design, construction, and test results of a modified sample holder used during low-temperature deep-level transient spectroscopy, current-voltage and capacitance-voltage measurements. This improved sample holder allows temperature scan rates of up to 6 K/min with a temperature shift of less than 1 K. High electrical isolation makes this sample holder also suitable for low-temperature current-voltage and capacitance-voltage measurements.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 1222-1224 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Epitaxial aluminum Schottky barrier diodes on molecular beam epitaxially grown p-GaAs with a free carrier density of 2×1016 cm−3 were irradiated with alpha particles at room temperature using an americium-241 (Am-241) radio nuclide. For the first time, the radiation induced hole defects are characterized using conventional deep level transient spectroscopy (DLTS). The introduction rates and DLTS "signatures'' of three prominent radiation induced defects Hα1, Hα4, and Hα5, situated 0.08, 0.20, and 0.30 eV above the valence band, respectively, are calculated and compared to those of similar defects introduced during electron irradiation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 65 (1989), S. 1972-1976 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: A new design for radiation-sensing field-effect transistors (RADFETs) is presented, involving the use of very thick silicon nitride layers deposited on top of a high-quality thermal silicon dioxide. In contrast to previous RADFET fabrication procedures, no attempt was made to introduce hole traps into the thermal oxide. Instead the trapping layer at the nitride oxide interface was used to store the positive charge which forms the basis for operation of the RADFET. Data is presented which shows hole transport in the thermal oxide. Models explaining the field dependence of the response and the saturation behavior of the dual dielectric device are given. These RADFETs are more stable than any previously described in the literature and have a sensitivity of 86 μV/rad dose at room temperature.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 1880-1882 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Over the past three years, the total TMX-U diagnostic data base has grown to exceed 10 Mbytes from over 1300 channels; roughly triple the originally designed size. This acquisition and processing load has resulted in an experiment repetition rate exceeding 10 min per shot using the five original Hewlett–Packard HP-1000 computers with their shared disks. Our new diagnostics tend to be multichannel instruments, which, in our environment, can be more easily managed using local computers. For this purpose, we are using HP series 9000 computers for instrument control, data acquisition, and analysis. Fourteen such systems are operational with processed format output exchanged via a shared resource manager. We are presently implementing the necessary hardware and software changes to create a local area network allowing us to combine the data from these systems with our main data archive. The expansion of our diagnostic system using the parallel acquisition and processing concept allows us to increase our data base with a minimum of impact on the experimental repetition rate.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 1929-1931 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A commercial database software package has been used to create several databases and tools that assist and enhance the ability of experimental physicists to analyze data from the Tandem Mirror Experiment-Upgrade (TMX-U) experiment. This software runs on a DEC-20 computer in M-Divisions's User Service Center at Lawrence Livermore National Laboratory (LLNL), where data can be analyzed off line from the main TMX-U acquisition computers. When combined with interactive data analysis programs, these tools provide the capability to do batch-style processing or interactive data analysis on the computers in the USC or the supercomputers of the National Magnetic Fusion Energy Computer Center (NMFECC) in addition to the normal processing done by the TMX-U acquisition system. One database tool provides highly reduced data for searching and correlation analysis of several diagnostic signals within a single shot or over many shots. A second database tool provides retrieval and storage of unreduced data for use in detailed analysis of one or more diagnostic signals. We will show how these database tools form the core of an evolving off-line data analysis environment on the USC computers.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3277-3279 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: For the MTX experiment, we use a network of computers for plasma diagnostic data acquisition and analysis. This multivendor network employs VMS, UNIX, and BASIC based computers connected in a local area Ethernet network. Some of the data is acquired directly into a VAX/VMS computer cluster over a fiber-optic serial CAMAC highway. Several HP-Unix workstations and HP-BASIC instrument control computers acquire and analyze data for the more data intensive or specialized diagnostics. The VAX/VMS system is used for global analysis of the data and serves as the central data archiving and retrieval manager. Shot synchronization and control of data flow are implemented by task-to-task message passing using our interprocess communication system. The system has been in operation during our initial MTX tokamak and FEL experiments; it has operated reliably with data rates typically in the range of 5 Mbytes/shot without limiting the experimental shot rate.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 114-130 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: In standard Mott electron polarimetry using thin gold film targets, extrapolation procedures must be used to reduce the experimentally measured asymmetries A to the values they would have for scattering from single atoms. These extrapolations involve the dependence of A on either the gold film thickness t or the maximum detected electron energy loss in the target ΔE. Using a concentric cylindrical-electrode Mott polarimeter, we have studied and compared these two types of extrapolations over the electron energy range 20–100 keV. The potential systematic errors which can result from such procedures are analyzed in detail, particularly with regard to the use of various fitting functions in thickness extrapolations, and the failure of perfect energy-loss discrimination to yield accurate polarizations when thick foils are used. A critical discussion of previous work on this subject is presented.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the time scale of a single FEL pulse.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...