Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The bifurcation nature of the electrostatic structure is studied in the toroidal helical plasma of the Compact Helical System (CHS) [K. Matsuoka et al., Proceedings of the 12th International Conference on Plasma Physics and Controlled Nuclear Fusion Research, Nice, 1988 (International Atomic Energy Agency, Vienna, 1989), Vol. 2, p. 411]. Observation of bifurcation-related phenomena is introduced, such as characteristic patterns of discrete potential profiles, and various patterns of self-sustained oscillations termed electric pulsation. Some patterns of the electrostatic structure are found to be quite important for fusion application owing to their association with transport barrier formation. It is confirmed, as is shown in several tokamak experiments, that the thermal transport barrier is linked with electrostatic structure through the radial electric field shear that can reduce the fluctuation resulting in anomalous transport. This article describes in detail spatio-temporal evolution during self-sustained oscillation, together with correlation between the radial electric field and other plasma parameters. An experimental survey to find dependence of the temporal and spatial patterns on plasma parameters is performed in order to understand systematically the bifurcation property of the toroidal helical plasma. The experimental results are compared with the neoclassical bifurcation property that is believed to explain the observed bifurcation property of the CHS plasmas. The present results show that the electrostatic property plays an essential role in the structural formation of toroidal helical plasmas, and demonstrate that toroidal plasma is an open system with a strong nonlinearity to provide a new attractive problem to be studied. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 857-859 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new method combining Li0-beam probing and spectroscopic techniques has been developed to measure local magnetic fields in a bumpy torus. A collimated thermal Li0 beam is injected into the plasma. The Zeeman pattern of the lithium resonance radiation (22S–22P, 6708 A(ring)) is observed with a Fabry–Perot interferometer. The strength of the local magnetic field is determined from the splitting between two π components of the 22S1/2–22P1/2 transition with the spatial resolution of about 7 mm. The magnetic fields from 2 to 4 kG were measured with accuracy of ±2%. This method is applicable to plasmas of a line-integrated electron density below 5×1012 cm−2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 1050-1052 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A lithium neutral beam probe has been improved for space and time-resolved measurements of plasma density in NBT-1M. A lithium neutral beam (4 keV, 10–30 μA) is injected into the plasma and photon flux emitted from the injected lithium atoms by electron impact excitation is detected. This cross section is not sensitive to the electron temperature in a wide range (10 eV〈Te 〈200 eV) and the photon flux intensity is proportional to the electron density. Typical spatial and temporal resolutions are 1 cm and a few milliseconds, respectively. Beam attenuation is not severe for plasmas with n1〈1014 cm−2 unless the ion temperature is very high (Ti 〉1 keV), where the attenuation through charge-exchange process becomes dominant. This method is not influenced by the magnetic field and can be applied to plasmas in any magnetic field configuration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 80 (2002), S. 1844-1846 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A GaAs junction field-effect transistor (JFET) is a promising candidate for low-frequency, low-noise, and low-power cryogenic electronics to read out high-impedance photodetectors. We report on the spectral noise characteristics of a SONY n-type GaAs JFET, operating at the depression mode, at a cryogenic temperature of 4.2 K. If the GaAs JFET is turned on at 4.2 K, a random telegraph signal (RTS) is found to be the dominant noise source at low frequencies. However, the switching rate of RTS can be drastically reduced if the GaAs JFET is heated up to 55 K and cooled down again to 4.2 K while keeping the same drain current flow. We refer to this phenomenon as the thermal cure (TC). With TC, low-frequency noise can be reduced to below 1 μV/Hz1/2 at 1 Hz. The critical temperature for TC is found to be ∼35 K for our GaAs JFET. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 3099-3101 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: In order to efficiency obtain a two-dimensional (2D) image in the 3 THz range, it is important to develop a 2D far-infrared detector array. We have developed a gallium-doped germanium (Ge:Ga) far-infrared photoconductor that has a longitudinal configuration. This structure is suitable for a large format monolithic 2D array. In this letter, we show that a transparent electrode that is responsive in the far-infrared range can be formed by ion implantation, and this layer contributed to increasing quantum efficiency. We obtained a high responsivity (16.2 A/W) and good noise equivalent power (2.6×10−17 W/Hz1/2) of Ge:Ga photoconductor in longitudinal configuration by combination of ion-implanted layers and Ge:Ga bulk material. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 29 (1989), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Mechanisms of the activation of T cells responding to major histocompatibility complex (MHC) class I antigen were investigated with special reference lo interleukin 1 (IL-1) production from stimulator-type accessory cells. For this purpose, we used mainly fractionated Lyt-2+ T cells of C57BL/6 (B6) mice as responder cells and irradiated spleen cells or those deprived of adherent cells of B6. C-H-2bm1 (bm 1) mice as stimulator ceils. Lyt-2+ T cells of B6 mice proliferated in the presence of irradiated whole spleen cells of bm1 mice but did not to Sephadex G-10 column-passed bm1 spleen cells. The unresponsiveness in the latter case was overcome by the supplement of recombinant IL-1 and/or IL-2 in the culture medium. These interleukins were shown to promote the proliferative response of B6 Lyt-2+ T cells in the presence of stimulator-type for B cells. Both interleukins also facilitated the generation of cytotoxic T cells from BA Lyt-2+ cells to H-2Kbm1 antigen in the mixed lymphocyte culture deficient in stimulator-type accessory cells. IL-1 was shown to enhance the expression of IL-2 receptor on the responding Lyt-2+ T cells as assessed by flow cytometry. IL-1 binding to responding T cells were also assayed by means of iodinated IL-1 and was shown to increase significantly on responding Lyt-2+ cells. Overall results indicate that accessory cells might play dual roles in the activation of Lyt-2+ T cells responding to allogeneic MHC class 1 antigen: direct presentation of the antigen to responder T cells and production of IL-1. Both signals are essentially required for Lyt-2+ T cells responding to allogeneic MHC class I antigen to initiate proliferation and also to differentiate into cytotoxic T cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 27 (1988), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Proliferative response of splenic T cells of C57BL/6 mice to mutant major histocompatibility complex (MHC) class I antigen (H-2Kbm1) was examined with regard to the role of accessory cells. T cell proliferation in mixed lymphocyte culture (MLC) was not induced when accessory cells were removed from stimulator spleen cells by passage through Sephadex G-10 or nylon-wool column. Anti-Iab antibodies did not inhibit the proliferative response to class I antigen, whereas the same antibodies completely blocked the response to class II antigen (Iabm12). Accessory cells may not be mere presenters of MHC class I antigen because stimulator cells fixed with 0.05% paraformaldehyde lost the stimulating function. The proliferative response was partially recovered by the addition of recombinant interleukin 1 (IL-1) and/or IL-2 to MLC devoid of stimulator type accessory cells. It is concluded that stimulatory type accessory cells were obligatorily involved in the T cell proliferation, and the production of IL-1 by accessory cells is thought to play a critical role in this process
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Allergy 55 (2000), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 151 (2004), S. 0 
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 30 (1988), S. 442-443 
    ISSN: 1432-1920
    Keywords: Syringobulbia ; MR image ; Meningioma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Syringobulbia with a large syrinx was revealed by MR imaging. The syrinx extended from the medulla to vertebral level T10. We suspect that this giant syrinx may be produced by a congenital meningioma at C7, generating pulsatile flow in the original syrinx and causing a giant syrinx.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...