Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Mineralium deposita 24 (1989), S. 229-229 
    ISSN: 1432-1866
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 243 (1986), S. 215-223 
    ISSN: 1434-4726
    Keywords: Tracheal prosthesis ; Transplantation ; Bioprosthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We removed the tracheas from sacrificed laboratory animals and subjected this tissue to multistep chemical processing. This method allowed us to preserve the cartilage and reduce its antigenicity, thus creating a bioprosthesis very similar to the host tissue. By using allogeneic and xenogeneic prostheses so prepared, no signs of immune rejections were seen following heterotopic or orthotopic implantations. The transplanted cartilage remained stable for periods ranging up to 21 weeks in recipient rats, while partial morphologic integrity of the cartilage was seen up to 1 year in pigs. Reepithelialization of the transplant with ciliated epithelium was completed in all specimens 12–24 weeks following surgery. Segmental replacement of up to one third of the whole trachea was possible in rats, whereas similar segmental replacements failed in pigs. We also found that successful reconstruction of window-shaped defects was possible. We consider our tracheal bioprosthesis to be superior to cialit-preserved grafts and also to most other biological reconstruction procedures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1435-2451
    Keywords: Bone transplantation ; Cryopreservation ; Transplantation immunology ; Knochentransplantation ; Kältekonservierung ; Transplantationsimmunologie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An der Wistar-Ratte wurden frische und kältekonservierte, ca. 10 mm lange, vc Periost und Mark befreite, allogene Corticalissegmente transplantiert. Innerhalb eines Beobachtung zeitraumes von 12 Wochen liessen sich mittels Leukocytenmigrationsinhibition und Capillarpräziptation sowohl celluläre als auch humorale Immunreaktionen gegen das Transplantat nachweisen. Eine Reduktion der Antigenität des Knochens durch die Kältekonservierung war nicht nachweisbar. Auf einen kausalen Zusammenhang zwischen Immunreaktion und Einheilungsergebnis kann nicht g schlossen werden.
    Notes: Summary Fresh and cryopreserved allogeneic corticalis segments - 10 mm in length and free from periosteum and bone marrow - were transplanted in Wistar rats. Within an observation period of 12 weeks, cell-mediated and humoral immune reactions could be demonstrated by leukocyte migration inhibition and capillary precipitation. There was no reduction in antigenicity after cryopreservation. In this study, there was no evidence of a correlation between immune reaction and healing of the graft.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 372 (1987), S. 955-955 
    ISSN: 1435-2451
    Keywords: Sheep ; Cruciate ligament ; Repair materials ; Biomechanics ; Schafe ; Kreuzband ; Ersatzmaterialien ; Biomechanik
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 98 Schafen wurde das vordere Kreuzband durch biologische oder/und synthetische Materialien ersetzt. Auf Grund der morphologischen und biomechanischen Ergebnisse werden gewisse Probleme der Prothesen vorgestellt: Design, Abrieb, Biokompatibilität, biologisches Einheilen und die Aussagekraft des makroskopischen Befundes im Vergleich mit biomechanischen Werten. Für die jeweiligen Prothesentypen spezifische Nachteile fordern eine strenge Indikationsstellung: die autologe Plastik erscheint immer noch überlegen.
    Notes: Summary In 98 sheep, the anterior cruciate ligament was replaced by biological or/and synthetic materials. Some of the problems with the prostheses were demonstrated by means of morphological and biomechanical results: design, wear, biocompatibility, biological healing, and the relation between the macroscopic aspect and biomechanical values. Specific complications in each type of prosthesis require definite indications: autologous repair still seems to be the best.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-2451
    Keywords: Prophylaxis ; Postoperative adhesion ; Fibrinolysis activators ; Prophylaxe ; Postoperative Adhäsionen ; Fibrinolyseaktivatoren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Postoperative (p.o.) Adhäsionen werden möglicherweise durch eine eingriffsbedingte Depression der intraperitonealen Fibrinolyse begünstigt. An Patienten wurde deshalb die biochemische Wirkung eines p.o. lokal applizierten Fibrinolytikums (Varidase, Lederle, Wolfratshausen) in Peritonealsekret und Blut dosis- und zeitabhängig untersucht. Fibrinolyseparameter (Plasminogen, α2 Antiplasmin, α2 M-Plasminkomplexe, jeweils chromogene Substratassays) sowie Plasminogenaktivatoren und spontane Fibrinolyse (Fibrinplattentests) zeigten 8 h p.o. ein Wirkungsmaximum nach 4 Ampullen (ä 100 000 LE. Streptokinase u. 25 000-100 000 LE. Streptodornase), bei einer maximalen Wirkungsdauer von 48 h. Noch höhere Dosierungen erzeugten gelegentlich Anzeichen einer systemischen Hyperfibrinolyse (auf Fibrinplatten). Wundheilungsstörungen traten nicht auf.
    Notes: Summary Postoperative (p.o.) adhesions are most likely induced by the depression of intraperitoneal fibrinolysis provoked by the surgical procedure. Therefore, the dose and time-dependent biochemical effect of a locally applied fibrinolytic agent (Varidase, Cyanamid Lederle, FRG) was studied in patients' peritoneal fluid and plasma. The parameters of fibrinolysis (plasminogen, α2-antiplasmin and α2 M-plasmin complexes with chromogenic substrates, plasminogen activators and spontaneous fibrinolytic activity on fibrin plates) indicate a maximal effect 8 h p.o. after 4 ampoules (100,000 IU streptokinase and 25,000 IU streptodomase). Elevated fibrinolysis lasted as long as 48 h. Higher amounts eventually induced systemic hyperfibrinolysis (on fibrin plates). Wound healing was not impaired.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 372 (1987), S. 852-853 
    ISSN: 1435-2451
    Keywords: Bone banks ; Revision surgery ; Hip prosthesis ; Bankknochen ; Prothesenaustausch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Im eigenen Krankengut entfallen mittlerweile 15% aller endoprothetischen Eingriffe auf Zweit- und Mehrfachoperationen: Zur Defektüberbrückung, vor allen Dingen im Bereich des Acetabulums wird hierbei allogene, kältekonservierte (− 90 °C) Spongiosa verwendet. In der Regel kommt es innerhalb von 26 Wochen zur vollständigen Konsolidierung auch bei zementierten Implantaten. In den letzten fünf Jahren wurden über 700 Transplantationen durchgeführt, die Erfolgsquote beläuft sich auf über 90%. In der Hüftchirurgie ist das allogene Spongiosatransplantat dem autogenen überlegen, nicht zuletzt deshalb werden einheitliche Richtlinien für Knochenbanken gefordert.
    Notes: Summary In recent years, 15% of all total joint replacements at our clinic have been revision operations: cryopreserved (− 90 °C), allogeneic cancellous bone is used to bridge defects, especially in the acetabulum. Even in cemented implants, complete bony consolidation usually takes 26 weeks. Within the past 5 years, 700 transplantations have been performed, with a success rate of more than 90%. In revision surgery of total hip replacement, allogeneic donor bone seems to be superior to autogenous transplants. We therefore recommend that standardized guidelines be instituted for bone banks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1435-2451
    Keywords: Osteomyelitis ; Local treatment ; Collagen ; Gentamycin ; Osteomyeltis ; Lokalbehandlung ; Kollagen ; Gentamicin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei über 150 Patienten mit posttraumatischer Osteomyelitis bzw. septischen Lockerungen von Totalendoprothesen wurde zur Lokalbehandlung der Knocheninfektion ein Kollagen-Antibioticumverbund eingesetzt. Das Typ-I-Kollagen als Trägermaterial ist vollständig resorbierbar, die Freisetzung des Gentamicin erfolgt anfangs durch Diffusion, später durch geweblichen Abbau. Die Antibioticumkonzentrationen in der Drainageflüssigkeit zeigen ausreichende lokale Wirkspiegel bei extrem niedrigen Urin- und Serumkonzentrationen des Aminoglycosids. Bei 12monatiger Beobachtungsdauer beträgt die Rezidivquote weniger als 15%.
    Notes: Summary An antibiotic drug-delivery system based on collagen has been applied in more than 150 cases of post-traumatic osteomyelitis and septic loosening following total joint replacement. The type-1-collagen used as the carrier material is completely resorbed. The gentamycin is initially liberated by diffusion and later by degradation and tissue reaction. The levels of the antibiotic in the drainage fluid demonstrated effective local concentrations, with comparatively low concentrations of the aminoglycoside occurring in urine and serum. During an observation period of 12 months, the recurrence rate was below 15%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 372 (1987), S. 944-944 
    ISSN: 1435-2451
    Keywords: Panreasocclusion ; Experiment ; Fibrin adhesive ; Pankreasocclusion ; Experiment ; Fibrinkleber
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An Ratten (n = 32) und Hunden (n = 6) wurde das exokrine Pankreas experimentell mit Fibrinkleber occludiert. Prolamin und Neoprene dienten als Kontrollsubstanzen. Bei Neoprene treten fortschreitende Fibrosen auf, Prolamin induziert eine granulomatöse Fremdkörperreaktion. Nach Occlusion mit Fibrinkleber findet sich eine leichte Fibrose; der Kleber ist nach 3 Wochen resorbiert. I.v. GTT und orale GTT bei Hunden zeigen keine Störung des Glucosemetabolismus. Der modifizierte Fibrinkleber dient somit als temporäres Occlusionsmittel, welches auch über Endoskope appliziert werden kann.
    Notes: Summary Fibrin adhesive has been used experimentally for duct occlusion in the pancreas of rats (n = 32) and dogs (n = 6). Prolamin and neoprene served as control materials: in the neoprene group progressive fibrosis was found; granuloma and foreign-body reaction were induced by prolamin. There was only mild fibrosis following occlusion with the fibrin adhesive, which is resorbed within 3 weeks. I.V. GTT and oral GTT in dogs demonstrated no impairment in glucose metabolism. Thus this modified fibrin adhesive can serve as a temporary occlusion material, which can also be applied in endoscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 366 (1985), S. 707-707 
    ISSN: 1435-2451
    Keywords: Fluorochrome labelling ; Bone ; Experimental surgery ; Polychrome Fluorescenzmarkierung von Knochen ; Experimentelle Chirurgie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Folgende Anwendungsgebiete der intravitalenpolychromen Fluorescenzmarkierung von Knochen auf dem Gebiet der experimentellen Chirurgie werden dargestellt:Strukturunterschiede der Kompakta von Versuchstieren; Grenzschichtbewertung bei derImplantatwerkstoffprüfung; Grenzschichtbewertung beiTotalendoprothesen, Korrelation von klinischem Befund and Mineralisation; Resorption bzw. Einbau vonkonservierten allogenen Transplantaten, Knochenaktivierung nachmechanischer and elektrischer Stimulation.
    Notes: Summary The efficacy of triple fluorochrome labelling of bone is described using some examples from the field of experimental surgery: bone architecture of some laboratory animals; interface to implanted materials; interface to total endoprostheses (correlation between clinical results and mineralization); bone growth and resorption around labelled transplanted bone after preservation; activation of mechanically and electrically stimulated bone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1435-2451
    Keywords: Vascular prosthesis ; Microvascular surgery ; Bovine xenograft ; Gefäßprothesen ; Mikrogefäßchirurgie ; Bovines Xenograft
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In einer tierexperimentellen Studie wurde die Anwendbarkeit der neuen xenogenen bovinen kollagenen Gefäßprothese (Solcograft-P ®) als kleinkalibriger GefaBersatz (ø 〈 2 mm) untersucht. Beobachtungsdauer: 9 (n= 13), 12 (n=7) Monate. Untersuchungsmethoden: Angiographie, Histomorphologie, Rasterelektronenmikroskop. Die Durchgangigkeitsrate im untersuchten Kaliberbereich betrug insgesamt 95%. Das Prothesenkollagen wurde unter Neubildung von kollagenem und elastischem Bindegewebe teilweise abgebaut. Eine überschießende Neointimabildung war nicht zu beobachten. Die lumenseitige Auskleidung der Prothese erfolgte durch eine homogene endothelartige Zellschicht. In 30% der Fälle traten Verkalkungen bzw. Verknöcherungen auf. In einem Fall war eine aneurysmatische Dilatation in Prothesenmitte zu beobachten. Vor einer klinischen Anwendung sollte die biomechanische Belastbarkeit unter hypertensiven Kreislaufbedingungen überprüft werden.
    Notes: Summary In an animal model, we investigated the applicability of a new bovine vessel xenograft (Solcograft-P) as a small vascular substitute (ø 〈 2 mm). The observation intervals were 9 (n=13) and 12 (n=7) months. Examination methods included: angiography, light microscopy, and scanning electronic microscopy. The small-diameter xenografts examined had an overall patency rate of 95%. The prosthesis collagen was progressively substituted by newly formed collagenous and elastic connective tissue. Neointimal hyperplasia did not occur. The lumen-side surface was formed by an endotheliumlike cell layer. In 6 of 20 cases calcification and ossification were observed. In 1 case we saw an aneurysmal dilatation in the middle of the prosthesis. Before clinical application, the biomechanical properties should be examined under hypertensive circulation conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...