Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Present-day Z-pinch experiments generate 200 TW peak power, 5–10 ns duration x-ray bursts that provide new possibilities to advance radiation science. The experiments support both the underlying atomic and plasma physics, as well as inertial confinement fusion and astrophysics applications. A typical configuration consists of a sample located 1–10 cm away from the pinch, where it is heated to 10–100 eV temperatures by the pinch radiation. The spectrally-resolved sample-plasma absorption is measured by aiming x-ray spectrographs through the sample at the pinch. The pinch plasma thus both heats the sample and serves as a backlighter. Opacity measurements with this source are promising because of the large sample size, the relatively long radiation duration, and the possibility to measure opacities at temperatures above 100 eV. Initial opacity experiments are under way with CH-tamped NaBr foil samples. The Na serves as a thermometer and absorption spectra are recorded to determine the opacity of Br with a partially-filled M-shell. The large sample size and brightness of the Z pinch as a backlighter are also exploited in a novel method measuring re-emission from radiation-heated gold plasmas. The method uses a CH-tamped layered foil with Al+MgF2 facing the radiation source. A gold backing layer that covers a portion of the foil absorbs radiation from the source and provides re-emission that further heats the Al+MgF2. The Al and Mg heating is measured using space-resolved Kα absorption spectroscopy and the difference between the two regions enables a determination of the gold re-emission. Measurements are also performed at lower densities where photoionization is expected to dominate over collisions. Absorption spectra have been obtained for both Ne-like Fe and He-like Ne, confirming production of the relevant charge states needed to benchmark atomic kinetics models. Refinement of the methods described here is in progress to address multiple issues for radiation science. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: During the past year we have conducted a series of PBFA II target experiments. The design of the experiments was threefold: to characterize the response of targets to ion beams, develop our experimental diagnostic capability, and benchmark our theoretical ability to design and predict the response of the experimental diagnostics to ion-beam-heated, ICF targets. We present here an analysis of spherical exploding pusher experiments. The targets were 6-mm-diam, 100-μm-thick, Cl-doped CH spheres, filled with 1.2 atm of deuterium doped with 7 Torr of H2S. The diagnostics included XRDs, x-ray pinhole, framing, and streak cameras, and a spatially resolved, x-ray crystal spectrometer. Our analysis includes comparisons between experimental results and theoretical predictions of diagnostics responses and sulfur line emission from the compressed target using one- and two-dimensional radiation/hydrodynamic code runs. This work supported by the U. S. Department of Energy under Contract No. DE-AC04-76-DP00789.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Ion beam divergence reduction will increase the power density deliverable to an ICF target and is one step towards demonstrating a credible path to target ignition. Measurement of the divergence is made with an ultracompact ion pinhole camera (UC-IPC). The UC-IPC is mounted in the PBFA II diode near the ion source at a 10° angle to compensate for beam bending in the diode's applied magnetic field. The beam is transported through an entrance pinhole and down an entrance tube to a gold scattering foil. The beam is scattered 90° through a second pinhole to CR39 film where the ion track count is recorded. This paper will describe the results of off-axis ion beam divergence measurements using the UC-IPC. Together with other diagnostics, the UC-IPC provides information about beam species and charge state, about particle energy and about divergence of the beam. This paper will also describe UC-IPC simulation using PICDIAG, a 2D code that models the ion transport and diagnostic response of experiments on Sandia's PBFA II accelerator. This work supported by the U. S. Department of Energy Contract No. DE-AC04-76DP00789.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Kα satellite line emission from targets irradiated by intense light ion beams can be used to diagnose plasma temperatures and densities. The fluorescence lines are created as 2p electrons drop down to fill 1s vacancies that result from ion beam-induced ionizations. We present results from collisional-radiative equilibrium calculations for thin Al diagnostic layers to illustrate the dependence of the Kα emission spectrum on temperature, density, and layer thickness. We also discuss the effects of opacity on the spectrum and the contribution from Kα transitions involving excited states.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Particle Beam Fusion Accelerator II is a light-ion fusion accelerator that is presently capable of irradiating a 6-mm-diam sphere with ∼50 kJ of 5.5-MeV protons in ∼15 ns. An array of particle and x-ray diagnostics fielded on proton Inertial Confinement Fusion target experiments quantifies the incident particle beam and the subsequent target response. An overview of the ion and target diagnostic setup and capabilities will be given in the context of recent proton beam experiments aimed at studying soft x-ray emission from foam-filled targets and the hydrodynamic response of exploding-pusher targets. Ion beam diagnostics indicate ∼100 kJ of proton beam energy incident within a 1.2-cm radius of the center of the diode with an azimuthal uniformity which varied between 6% and 29%. Foam-filled target temperatures of 35 eV and closure velocities of 4 cm/μs were measured.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The CR-39/range-filter technique measures ion energy by determining the maximum filter thickness which ions can penetrate. CR-39 located behind the filter records the ions. This method is used to measure peak voltage in pulsed power accelerators. We investigated range and straggling effects in this diagnostic by exposing it to 8- and 15-MeV protons for both Al and Ta filters. The range agreed with published values to better than ±6%. The range straggling decreased for higher incident ion energy and lower atomic number, as expected, although there were differences up to a factor of 1.7 between the experimental values and predictions. The dependence of the track diameter distribution on ion energy enabled us to establish a signature which is characteristic of ions which penetrate a filter, via straggling. These results can be used to evaluate the errors present when this diagnostic is used to measure accelerator voltage.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: X-ray powers on the order of 10 TW over an area of 4.5 mm2 are produced in the axial direction from the compression of a low-density foam target centered within a z-pinch on the Z generator.1 The x rays from this source are used for high-energy–density physics experiments, including the heating of hohlraums for inertial confinements fusion studies.2 In this article, detailed characteristics of this radiation source measured using an upgraded axial-radiation-diagnostic suite3 together with other on- and off-axis diagnostics are summarized and discussed in terms of Eulerian and Lagrangian radiation–magnetohydrodynamic code simulations. The source, characterized here, employs a nested array of 10-mm-long tungsten wires, at radii of 20 and 10 mm, having a total masses of 2 and 1 mg, and wire numbers of 240 and 120, respectively. The target is a 14 mg/cc CH2 foam cylinder of 5 mm diameter. The codes take into account the development of the Rayleigh–Taylor instability in the r–z plane, and provide integrated calculations of the implosion together with the x-ray generation. The radiation exiting the imploding target through the 4.5 mm2 aperture is measured primarily by the axial diagnostic suite that now includes diagnostics at an angle of ∼30° to the z axis. The near on-axis diagnostics include: (1) a seven-element filtered silicon-diode array,4 (2) a five-element filtered x-ray diffraction (XRD) array,5 (3) a six-element filtered PCD array,6 (4) a three-element bolometer,7 (5) time-resolved and time-integrating crystal spectrometers, and (6) two fast-framing x-ray pinhole cameras having 11 frames each. The filtered silicon diodes, XRDs, and PCDs are sensitive to 1–200, 140–2300, and 1000–4000 eV x rays, respectively. They (1) establish the magnitude of the prepluse generated during the run in of the imploding wire arrays, (2) measure the Planckian nature of the dominant thermal, and (3) nonthermal component of the emission. The bolometers and XRDs mounted on the near-normal and 30° LOS (line-of-sight) measure the total power and check the Lambertian nature of the emission. Additionally, a suite of filtered fast-framing x-ray pinhole cameras and silicon-diode arrays behind a transmission grating, mounted on LOSs nearly normal to the z axis, quantify the plasma plume exiting the aperture. The hard bremsstrahlung generated is estimated with both on- and off-axis shielded scintillator photomultiplier diagnostics. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    European journal of soil science 52 (2001), S. 0 
    ISSN: 1365-2389
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: The test for the degree of phosphorus (P) saturation (DPS) of soils is used in northwest Europe to estimate the potential of P loss from soil to water. It expresses the historic sorption of P by soil as a percentage of the soil's P sorption capacity (PSC), which is taken to be α (Alox + Feox), where Alox and Feox are the amounts of aluminium and iron extracted by a single extraction of oxalate. All quantities are measured as mmol kg soil−1, and a value of 0.5 is commonly used for the scaling factor α in this equation. Historic or previously sorbed P is taken to be the quantity of P extracted by oxalate (Pox) so that DPS = Pox/PSC.The relation between PSC and Alox, Feox and Pox was determined for 37 soil samples from Northern Ireland with relatively large clay and organic matter contents. Sorption of P, measured over 252 days, was strongly correlated with the amounts of Alox and Feox extracted, but there was also a negative correlation with Pox. When PSC was calculated as the sum of the measured sorption after 252 days and Pox, the multiple regression of PSC on Alox and Feox gave the equation PSC = 36.6 + 0.61 Alox+ 0.31 Feox with a coefficient of determination (R2) of 0.92. The regression intercept of 36.6 was significantly greater than zero. The 95% confidence limits for the regression coefficients of Alox and Feox did not overlap, indicating a significantly larger regression coefficient of P sorption on Alox than on Feox. When loss on ignition was employed as an additional variable in the multiple regression of PSC on Alox and Feox, it was positively correlated with PSC. Although the regression coefficient for loss on ignition was statistically significant (P 〈 0.001), the impact of this variable was small as its inclusion in the multiple regression increased R2 by only 0.028. Values of P sorption measured over 252 days were on average 2.75 (range 2.0–3.8) times greater than an overnight index of P sorption. Measures of DPS were less well correlated with water-soluble P than either the Olsen or Morgan tests for P in soil.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Lithium fluoride, field-enhanced ion source experiments are being performed on PBFA II. The source consists of a thin coating of LiF on a microscopically rough substrate. Diagnostics to measure ion beam energy, purity, and transport include electrical monitors, Faraday cups, nuclear activation, ion pinhole camera, Rutherford magnetic spectrograph, and shadowbox aperture array. With PBFA II operating at three-quarters energy, the source has produced 16 TW of ion power and 550 kJ of ion energy with 70% diode efficiency. Over 26 kJ of lithium beam energy has been focused to the diode center axis with a peak energy density of about 1.3 kJ/cm2 . PICDIAG simulations of the lithium focus indicate the intrinsic source divergence is about 45 mrad with a 20-μm-grade porous stainless-steel substrate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1520-4804
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...