Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (12)
  • 79.20  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 31 (1983), S. 37-44 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The areal density and the depth distribution of3He trapped in Ni as a function of the bombarding fiuence was measured in the energy range of 1–25 keV and at angles of incidence between 0 and 85° using nuclear reaction analysis. At fluences below saturation a linear relation is found between the areal density and the fiuence. From its slope the trapping and reflection coefficients can be determined. The experimental data for trapping and reflection coefficients and for the depth profiles were compared with computer simulation results from the TRIM program. To reduce uncertainties in the absolute values of the experimental trapping coefficients, they were normalized to the TRIM values at normal incidence. The dependence of the measured reflection coefficient on the angle of incidence between 0 and 80° shows good agreement with the calculated data for incident energies from 3 to 25 keV, but for 1 keV the measured reflection coefficients are higher than the calculated ones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 265-268 
    ISSN: 1432-0630
    Keywords: 79.20
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Trapping and particle reflection coefficients for 0.4–10keVD on graphite have been measured for angles of incidence 0≦α≦85° by determining the areal density of implanted D as a function of the implanted fluence. The experimental data are compared to computer calculations with the TRIM-program. The agreement between measurement and calculation is good.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 365-368 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Various matrices were used for laser-desorption ionization of mixtures of small DNA segments. Parent negative ions of 34-mer as well as other smaller single-stranded oligomers were observed for selected organic acids and dye compounds. Both positive and negative parent ions were observed with very little fragmentation. Effects of various matrices and the potential applications to DNA sequencing are briefly discussed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 435-439 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Various isomer matrices were used for laser-desorption ionization of mixtures of oligomers. It was found that the efficiency of production of oligomer ions changed drastically when different isomers were used as matrices. For selected matrix materials, parent oligomer ions with sizes up to 64 bases were observed.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 673-677 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: We found that picolinic acid is a very good matrix for matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry of oligonucleotides, proteins and tRNA. Among the oligonucleotides, picolinic acid was shown to be effective for homo-oligonucleotides, d(G)40 and d(C)60, and for mixed-base oligonucleotides up to 190 bases. In the case of the single-stranded oligonucleotides, and of double-stranded ones as well, only parent ions corresponding to single-stranded DNA were observed. The efficiency for MALDI of oligonucleotides using the picolinic acid matrix was superior to that using 3-hydroxypicolinic acid. MALDI of transfer RNA phenylalanine-specific (tRNAphe), a 76-base ribonucleic acid, was detected with a signal-to-noise ratio of 〉10. By comparison with 3-hydroxypicolinic acid the results with picolinic acid are notably superior for all oligonucleotides.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 1001-1006 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: 3-Aminopicolinic acid (3-APA) was tested and found to be a useful matrix for matrix-assisted laser desorption/ionization of DNA and protein. Single-stranded DNA segments of 150-mer and double-stranded DNA of 246 base pairs were successfully detected by using 3-APA as an ultraviolet-absorbing matrix in a linear time-of-flight mass spectrometer. In the case of the double-stranded DNA, only parent ions corresponding to single-stranded DNA were observed. The comparison with 3-hydroxypicolinic acid and picolinic acid matrices is discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 727-730 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: We report the first detection of DNA segments as large as 500 nucleotides by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, using picolinic acid and 3-hydroxypicolinic acid mixtures as desorption matrices. The successful detection of 500-nucleotide DNA indicates that laser mass spectrometry is now emerging as a new biotechnology tool for DNA-related research. It should be possible to utilize fast detection of large DNA segments by laser mass spectrometry for rapid human genome sequencing.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1315-1320 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Matrix-assisted laser desorption/ionization (MALDI) was used for several small proteins (such as insulin) and for peptides. It was found that the detection efficiencies of MALDI for the insulin B chain and the insulin A chain are drastically different. Similar phenomena were also observed for various types of peptides. The positive-ion signal of MALDI in detecting proteins or peptides was found to be greatly enhanced by the presence of a basic amino acid in their chains. The experimental results indicate that this enhancement may arise from proton transfer in solution by an acid-base reaction between the protein/peptide and matrix molecule. This pre-protonated mechanism provides a low energy barrier for the ionization of peptides in a MALDI process, and greatly reduces the energy threshold of MALDI. Matrix effects on the ionization mechanism are discussed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 63-66 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Matrix-assisted laser desorption/ionization mass spectrometry has been used to mass analyze synthetic oligomers of poly-T ranging in size from 20 to 100 nucleotides. Both positively- and negatively-charged parent molecular ions were observed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 943-948 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Ferulic acid, 3-hydroxypicolinic acid (3-HPA), and 2,5-dihydroxybenzoic acid (2,5-DHB) were used as matrices in MALDI of various oligonucleotides. It was found that 2,5-DHB is an excellent matrix for polydeoxyribothymi-dylic acid. A poly-T oligonucleotidc with a size of 130 bases was successfully detected. 3-HPA was found to be a good matrix for MALDI of homo-oligomeric deoxynucleotides as well as those containing four different bases. Parent ions of pd(A)60, d(T)100 d(G)40, and d(C)40 were observed, and a mixed-base oligonucleotide of 150-mer was also detected. Polymer ions of poly-A as large as 420-mer were measured; however, the efficiency for detecting poly-T with 3-HPA as a matrix was slightly worse than when 2,5-DHB was used. Comparisons of three matrices for various oligonucleotides is also presented.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...