    ISSN: 1432-055X
    Keywords: Schlüsselwörter Transportable Kapnometer ; Rettungsdienst ; Genauigkeit ; Key words Portable capnometers ; Emergency medicine ; Accuracy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Capnometry, the noninvasive measurement of end-expiratory CO2 concentration (cCO2, vol%) or calculation of its respective partial pressure (pCO2; mmHg) is an established method. However, for prehospital settings, capnometry is still used very restrictively, mainly owing to the respective devices used. The prerequisite for their use is sufficient accuracy (±2 mmHg) and easy handling. Two special capnometers (STAT CAP, Nellcor: mainstream, semiquantitative estimation; Capnocheck 8200, BCI: sidestream, quantitative measurement, numeric display), developed recently for potential use in emergency medicine, are said to fit these criteria. Therefore, the objective of the present investigation was to assess the accuracy and precision of both devices, comparing methods under standardized in vitro (reference gases) and in vivo (intubated and ventilated patients) conditions. Methods. Both devices (“STAT CAP”: pCO2 range, light bars; “Capnocheck 8200”) were evaluated regarding the accuracy of pCO2 (Capnocheck) and the precision of the CO2 range (STAT CAP). Tests were performed with four dry gas mixtures (STPD) of defined composition and during ventilation of 20 intubated patients (BTPS). All measurements were compared with the alveolar gas monitor “AGM 1304” (Brüel & Kjaer, Denmark) as a reference method with a proven ±1 mmHg accuracy of pCO2 measurement. Results. The “Capnocheck” (BCI) presented an accuracy of the pregiven pCO2 of 0.7–1.4 mmHg (dry gas mixtures, STPD) and an overestimation of 0.2±4.1 mmHg (BTPS) during ventilation with pure oxygen; inaccuracy during ventilation with 70% N2O in O2 proved to be +1.2±1.7 mmHg (BTPS). Nellcor's “STAT CAP” failed to reach the target value in 10% of analyses, as shown by the respective segment bar of the display. Conclusion. Evaluation of the accuracy of capnometers must focus on the necessary pH2O correction and the possible effects exercised by O2 (and N2O) as well as the possible dependence on barometric pressure (if pCO2, mmHg, is the desired value). The “Capnocheck” showed an accuracy of more than 2 mmHg in dry gas mixtures as well as in humidified air. Concerning the practical use during constant artificial ventilation, the digital display and accuracy of the sidestream capnometer allow for reliable conclusions on patients' ventilation and circulation (CO2 elimination). The 90% accuracy of the segment bar display of Nellcor's “STAT CAP”, per se covering only a rather broad range of 20 mmHg, obviously does not provide more than a rough overview. Therefore, the STAT CAP cannot be recommended for prehospital capnometry in the field. However, both the accuracy of the BCI capnometer (Capnocheck) and its numeric display and easy handling strongly recommend this device also for clinical use.
    Notes: Zusammenfassung Ziel vorliegender Untersuchung war die Prüfung der CO 2 -Meßgenauigkeit bzw. -Meßbereichspräzision zweier neuer, potentiell für den Rettungsdienst konzipierter Kapnometer unterschiedlicher Funktionsweise im Rahmen eines Methodenvergleichs. Untersucht wurden das Hauptstrom- (STAT CAP, Nellcor: Balkensegmentanzeige, pCO 2 -Bereiche) und das Nebenstromkapnometer (Capnocheck 8200, BCI International: pCO 2 -Wertanzeige). Geprüft wurde mit vier Referenzgasen und an 20 beatmeten Patienten. Als Referenzmethode diente der Atemgasmonitor „AGM 1304“ (Brüel & Kjaer) mit einer pCO 2 -Meßgenauigkeit von ±1 mm Hg. Die Abweichungen des „Capnocheck“ vom Sollwert betrugen für die Prüfgase 0,7–1,4 mm Hg, bei Beatmung mit reinem O 2 0,2±4,1 mm Hg (unter N 2 O 1,2–1,7 mm Hg). Der „STAT CAP“ traf den vorgegebenen Sollwert nur in 90% mit dem richtigen Segment seiner Bereichsanzeige. Der „Capnocheck“ erreichte sowohl in trockenen Prüfgasen (STPD) als auch in wasserdampfgesättigter Ausatemluft (BTPS) eine pCO 2 -Meßgenauigkeit von ≤±2 mm Hg. Die Bereichsanzeige des „STAT CAP“ erlaubt aufgrund der Unschärfe des pCO 2 -Bereichs von 20 mm Hg sowie wegen des 10%igen Trefffehlers lediglich eine grobe Orientierung. Dieses Gerät (Preis ca. DM 2500) ist zur Verwendung als Kapnometer im eigentlichen Sinne untauglich, könnte jedoch zur „vor-Ort-Beurteilung“ der Tubuslage Bedeutung erlangen. Die Meßgenauigkeit und gute Handhabbarkeit des „Capnocheck“ empfehlen dieses Kapnometer (Preis ca. DM 4500) sowohl für den potentiellen Einsatz bei beatmeten Patienten im Rettungsdienst als auch für den innerklinischen Betrieb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Key words Paediatric anaesthesia ; Desflurane ; Isoflurane ; Intubating conditions ; Recovery times ; Schlüsselwörter Kinderanästhesie ; Desfluran ; Isofluran ; Intubationsbedingungen ; Aufwachzeiten
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Das Inhalationsanästhetikum Desfluran ist aufgrund seiner geringen Löslichkeit durch ein rasches Ein- und Auswaschverhalten gekennzeichnet. Dies könnte gerade im Kindesalter bei kurzdauernden HNO-Eingriffen von Vorteil sein, wenn dadurch die Intubationsbedingungen zu verbessern und die Aufwachphase zu beschleunigen wären. Dies sollte in der vorliegenden Untersuchung im Vergleich mit Isofluran überprüft werden. Methodik: Untersucht wurden 4–12jährige Kinder (ASA I–II), die sich einem kurzdauernden HNO-Elektiveingriff (z.B. Tonsillektomie) unterziehen mußten. Die Narkose wurde intravenös mit 5–8 mg/kg Thiopental eingeleitet; die anschließende Maskenbeatmung erfolgte mit 6 l/min O2, wobei der Desfluran- bzw. Isofluran-Vapor auf 1 MAC (altersadaptiert) geöffnet wurde. Nach 3 Beatmungshüben wurden 0,05 mg/kg Vecuronium injiziert und die Intubationsbedingungen 3 min später beurteilt. Die weitere Narkoseführung erfolgte nach den üblichen klinischen Kriterien mit Desfluran oder Isofluran in 50% N2O/O2, die Zufuhr endete mit der letzten operativen Maßnahme, danach wurden die üblichen Aufwachzeiten ermittelt. Gemäß Poweranalyse (α-Fehler〈0,05, β-Fehler〈0,10) war eine Gruppenstärke von je 20 Patienten erforderlich. Ergebnisse: Insgesamt wurden 44 Kinder (je n=22) untersucht. Die Intubationsbedingungen waren in der Desflurangruppe signifikant besser (sehr gut” oder „gut” bei 20 von 22 Kindern) als in der Isoflurangruppe (12 von 22; s. Tabelle 2). Auch die Aufwachzeiten waren nach Desflurananästhesie signifikant kürzer als nach Isofluran (x±SEM): Spontanatmung 4,0±0,5 min vs. 6,0±0,7 min, Extubation 8,4±0,7 vs. 11,4±1,1 min und Ankunft im AWR 11,5±0,8 vs. 16,6±1,5 min (s. Abb. 1). Atemwegskomplikationen (Husten, Laryngospasmus, Abfall der Sauerstoffsättigung 〈97%) traten in beiden Gruppen nicht auf. Schlußfolgerungen: Der Einsatz von Desfluran ist auch im Kindesalter eine interessante Alternative zu Isofluran und kann nach intravenöser Narkoseeinleitung mit besseren Intubationsbedingungen und kürzeren Aufwachzeiten einhergehen.
    Notes: Abstract Background: The inhaled anaesthetic desflurane is characterized by a rapid wash-in and wash-out and may be useful for short paediatric ENT procedures. Therefore, this study was designed to compare the effects of desflurane or isoflurane on intubating conditions and recovery characteristics in paediatric ENT patients. Methods: In this prospective, randomised investigation, we studied 44 children scheduled for ENT surgery, aged 4–12 yr and classified ASA I–II. After thiopentone induction (5–8 mg/kg) the lungs were ventilated by face mask and the vaporizer was dialed to 1 MAC (age-adapted) of desflurane of isoflurane. A reduced dose of vecuronium (0.05 mg/kg) was administered, and intubating conditions were rated 3 min later. Following tracheal intubation, 50% nitrous oxide were added, and the concentration of desflurane or isoflurane was adjusted according to clinical needs. At the end of surgery all anaesthetics were discontinued simultaneously and recovery times were recorded. Results: Intubating conditions were rated significantly better for desflurane (excellent or good 20 of 22) than for isoflurane (12 of 22). Recovery times were significantly shorter for desflurane than for isoflurane (mean±SE): spontaneous ventilation 4.0±0.5 min vs. 6.0±0.7 min, extubation 8.4±0.7 vs. 11.4±1.1 min and arrival at PACU 11.5±0.8 vs. 16.6±1.5 min. No airway complications (coughing, laryngospasm, or desaturation 〈97%) were noted for either anaesthetic. Conclusions: Following an intravenous induction improved intubating conditions, shorter recovery times and the lack of airway complications make desflurane a suitable alternative to isoflurane for paediatric ENT anaesthesia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Remifentanil ; Propofol ; Isofluran ; Aufwachverhalten ; Shivering ; Key words Remifentanil ; Propofol ; Isoflurane ; Recovery times ; Shivering
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objectives: Due to its unique pharmacokinetics, the new esterase-metabolised opioid remifentanil results in rapid post-anaesthesia recovery. The aim of this clinical investigation was to compare recovery times after remifentanil anaesthesia in combination with hypnotic concentrations of either propofol or isoflurane. Dosages used in the study protocol were based on recommendations by the pharmaceutical manufacturer. Methods: Patients (ASA status I–II) scheduled for elective arthroscopy were included in this trial. Without premedication in the morning, anaesthesia was induced identically in both groups: remifentanil bolus (1 µg/kg), start of remifentanil-infusion (0.5 µg/kg/min), followed immediately by propofol (ca. 2 mg/kg). For maintenance of anaesthesia remifentanil (0.25 µg/kg/min) was combined with either a propofol infusion of 0.1 mg/kg/min or 0.5 MAC isoflurane (=0.6 vol.%) in O2/air. Anaesthetic delivery was discontinued simultaneously with termination of surgery and recovery times were recorded. Results: A total of 40 patients were studied at random in two groups of 20 each with comparable demographic data and anaesthetic technique (Tables 1 and 2). In both groups emergence was very rapid. Recovery times were significantly shorter for remifentanil-isoflurane than for remifentanil-propofol (Table 3): spontaneous ventilation 5.1 vs 8.1 min (P〈0.05), extubation 5.5 vs. 8.6 min (P〈0.02), post-anaesthesia recovery score ≥9 of 10 points 6.2 vs 11.3 min (P〈0.01), and arrival at PACU 16.2 vs 19.2 min (P〈0.01). Mild to moderate shivering was noted in 40% of all patients (9 cases following isoflurane, 7 following propofol). Conclusions: Using the manufacturer’s recommended dosages, emergence after remifentanil anaesthesia is more rapid with 0.5 MAC isoflurane than with 0.1 mg/kg/min propofol. These results are most probably due to the different pharmacological properties of both co-anaesthetics, especially the applied dosages, and to different interactions with remifentanil. Present clinical experience suggests that a further dose reduction, especially for propofol, is possible. For both remifentanil groups emergence was remarkably rapid between return of consciousness and the awake state (on-off phenomenon), which might contribute to post-anaesthesia safety.
    Notes: Zusammenfassung Das neue Opioid Remifentanil wird rasch durch unspezifische Blut- und Gewebeesterasen metabolisiert und läßt so kurze Aufwachzeiten erwarten. In der vorliegenden klinischen Untersuchung sollte das Aufwachverhalten bei Kombination von Remifentanil mit Propofol oder Isofluran in hypnotisch wirksamen Konzentrationen verglichen werden. Methodik: Untersucht wurden 40 Patienten (ASA I–II), die sich einer elektiven Arthroskopie unterziehen mußten. Die Narkoseeinleitung war in beiden Gruppen identisch: Remifentanilbolus (1 µg/kg), Beginn der Remifentanilinfusion (0,5 µg/kg/min), sofort anschließend Propofol (ca. 2 mg/kg). Die weitere Narkoseführung erfolgte mit Remifentanil 0,25 µg/kg/min in Kombination mit 0,1 mg/kg/min Propofol oder mit 0,5 MAC Isofluran (=0,6 Vol.-%) in O2/Luft. Die Anästhetikazufuhr wurde erst mit der letzten Hautnaht beendet und die üblichen Aufwachzeiten ermittelt. Ergebnisse: In beiden Gruppen (je n=20) benötigte der Aufwachvorgang zwischen beginnender Rückkehr des Bewußtseins und vollständiger Wachheit nur ca. 90 s. Dabei waren die Aufwachzeiten in der Remifentanil-Isoflurangruppe signifikant kürzer als in der Remifentanil-Propofolgruppe: Spontanatmung im Mittel nach 5,1 vs. 8,1 min (p〈0,05), Extubation nach 5,5 vs. 8,6 min (p〈0,02). Diskussion: Bei der vom Hersteller empfohlenen Dosierung verlief die Aufwachphase nach Remifentanil mit 0,5 MAC Isofluran signifikant schneller als bei der Kombination von Remifentanil mit 0,1 mg/kg/min Propofol. Bisherige klinische Erfahrungen lassen vermuten, daß insbesondere die Propofoldosis weiter reduziert werden kann. Die für beide Remifentanilgruppen bemerkenswert kurze Zeitspanne zwischen beginnender Rückkehr des Bewußtseins und anschließend vollständiger Wachheit ohne Atemdepression (ON-OFF-Phänomen) kann zur postanästhesiologischen Sicherheit beitragen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...