Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Cellular and molecular life sciences 45 (1989), S. 337-339 
    ISSN: 1420-9071
    Keywords: Heart muscle ; opioids ; morphine ; ethylketocyclazocine ; cardiac function ; presynaptic modification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The opioid agonists morphine (selective for μ-receptors) and ethylketocyclazocine (selective for kappa-receptors), at concentrations evoking strong effects in neuronal structures, did not significantly affect the configuration of the intracellularly recorded action potential and the force of contraction in ventricular heart muscle isolated from guinea pigs, rabbits and man. These results suggest that any changes of heart functions in vivo in response to opioid-like drugs are probably not mediated postsynaptically at the myocardial cell membrane but rather presynaptically, influencing the release of noradrenaline and/or acetylcholine from the nerve terminals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Transportable Kapnometer ; Rettungsdienst ; Genauigkeit ; Key words Portable capnometers ; Emergency medicine ; Accuracy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Capnometry, the noninvasive measurement of end-expiratory CO2 concentration (cCO2, vol%) or calculation of its respective partial pressure (pCO2; mmHg) is an established method. However, for prehospital settings, capnometry is still used very restrictively, mainly owing to the respective devices used. The prerequisite for their use is sufficient accuracy (±2 mmHg) and easy handling. Two special capnometers (STAT CAP, Nellcor: mainstream, semiquantitative estimation; Capnocheck 8200, BCI: sidestream, quantitative measurement, numeric display), developed recently for potential use in emergency medicine, are said to fit these criteria. Therefore, the objective of the present investigation was to assess the accuracy and precision of both devices, comparing methods under standardized in vitro (reference gases) and in vivo (intubated and ventilated patients) conditions. Methods. Both devices (“STAT CAP”: pCO2 range, light bars; “Capnocheck 8200”) were evaluated regarding the accuracy of pCO2 (Capnocheck) and the precision of the CO2 range (STAT CAP). Tests were performed with four dry gas mixtures (STPD) of defined composition and during ventilation of 20 intubated patients (BTPS). All measurements were compared with the alveolar gas monitor “AGM 1304” (Brüel & Kjaer, Denmark) as a reference method with a proven ±1 mmHg accuracy of pCO2 measurement. Results. The “Capnocheck” (BCI) presented an accuracy of the pregiven pCO2 of 0.7–1.4 mmHg (dry gas mixtures, STPD) and an overestimation of 0.2±4.1 mmHg (BTPS) during ventilation with pure oxygen; inaccuracy during ventilation with 70% N2O in O2 proved to be +1.2±1.7 mmHg (BTPS). Nellcor's “STAT CAP” failed to reach the target value in 10% of analyses, as shown by the respective segment bar of the display. Conclusion. Evaluation of the accuracy of capnometers must focus on the necessary pH2O correction and the possible effects exercised by O2 (and N2O) as well as the possible dependence on barometric pressure (if pCO2, mmHg, is the desired value). The “Capnocheck” showed an accuracy of more than 2 mmHg in dry gas mixtures as well as in humidified air. Concerning the practical use during constant artificial ventilation, the digital display and accuracy of the sidestream capnometer allow for reliable conclusions on patients' ventilation and circulation (CO2 elimination). The 90% accuracy of the segment bar display of Nellcor's “STAT CAP”, per se covering only a rather broad range of 20 mmHg, obviously does not provide more than a rough overview. Therefore, the STAT CAP cannot be recommended for prehospital capnometry in the field. However, both the accuracy of the BCI capnometer (Capnocheck) and its numeric display and easy handling strongly recommend this device also for clinical use.
    Notes: Zusammenfassung Ziel vorliegender Untersuchung war die Prüfung der CO 2 -Meßgenauigkeit bzw. -Meßbereichspräzision zweier neuer, potentiell für den Rettungsdienst konzipierter Kapnometer unterschiedlicher Funktionsweise im Rahmen eines Methodenvergleichs. Untersucht wurden das Hauptstrom- (STAT CAP, Nellcor: Balkensegmentanzeige, pCO 2 -Bereiche) und das Nebenstromkapnometer (Capnocheck 8200, BCI International: pCO 2 -Wertanzeige). Geprüft wurde mit vier Referenzgasen und an 20 beatmeten Patienten. Als Referenzmethode diente der Atemgasmonitor „AGM 1304“ (Brüel & Kjaer) mit einer pCO 2 -Meßgenauigkeit von ±1 mm Hg. Die Abweichungen des „Capnocheck“ vom Sollwert betrugen für die Prüfgase 0,7–1,4 mm Hg, bei Beatmung mit reinem O 2 0,2±4,1 mm Hg (unter N 2 O 1,2–1,7 mm Hg). Der „STAT CAP“ traf den vorgegebenen Sollwert nur in 90% mit dem richtigen Segment seiner Bereichsanzeige. Der „Capnocheck“ erreichte sowohl in trockenen Prüfgasen (STPD) als auch in wasserdampfgesättigter Ausatemluft (BTPS) eine pCO 2 -Meßgenauigkeit von ≤±2 mm Hg. Die Bereichsanzeige des „STAT CAP“ erlaubt aufgrund der Unschärfe des pCO 2 -Bereichs von 20 mm Hg sowie wegen des 10%igen Trefffehlers lediglich eine grobe Orientierung. Dieses Gerät (Preis ca. DM 2500) ist zur Verwendung als Kapnometer im eigentlichen Sinne untauglich, könnte jedoch zur „vor-Ort-Beurteilung“ der Tubuslage Bedeutung erlangen. Die Meßgenauigkeit und gute Handhabbarkeit des „Capnocheck“ empfehlen dieses Kapnometer (Preis ca. DM 4500) sowohl für den potentiellen Einsatz bei beatmeten Patienten im Rettungsdienst als auch für den innerklinischen Betrieb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 47 (1998), S. 968-974 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Biosensoren ; Photometrie ; Meßmethodik ; Meßgenauigkeit ; Präzision ; Qualitätskontrolle ; Klinik ; Key words Biosensor technology ; Photometry ; Methodology ; Accuracy ; Precision ; Quality control ; Clinical implication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract The introduction of biosensor technology for near bedside measurement of plasma lactate concentrations has been a promising step for critical care profiling. However, methodological drawbacks and relevant inaccuracy have been reported. With the advent of a new biosensor (Chiron Diagnostics) and a revised NOVA Biomedical device, accuracy was expected to be improved. The goal of the present investigation was to evaluate the accuracy of both methods. Methods: Two devices (System 860, Chiron Diagnostics; StatProfile 9, NOVA Biomedical) were simultaneously analysed using 9 biosensors in both fresh frozen plasma and citrated whole blood. The results were compared with an established photometric method (Lactat PAP, Analyticon). Measurements were performed as duplicates (n=1120) before and after the addition of 1molar sodium lactate solution (2–24 mmol/L). For the estimation of between-day precision commercially available aqueous and serum-based quality controls were analysed daily over a period of 60 days. Results: Reproducibility in blood was 2.6± 2.8% (Chiron), 4.1±4.0% (NOVA) and 1.5± 2.1% (Analyticon), in plasma respectively 2.1±2.4%, 2.1±2.9% and 1.0±1.1%. Mean inaccuracy in plasma presented to be –0.2± 16.4% (plasma) and +7.2±13.1% (blood) for Chiron, +9.4±18.4% and +18.7±16.7% for NOVA, and –37.8±18.2% and –27.5±17.6% for Analyticon. Calculated between-day-precision (variation coefficients mean values) was 11.5±4.9% (Chiron) and 14.0±5.9% (NOVA). Conclusion: Although accuracy of lactate concentrations obtained with biosensor technology has improved (x- 0–18%), the variability of the results still poses a problem (x- 13–18%). Therefore, from the methodological point of view, interpretation of a single lactate value requires caution when applying to the critically ill, particularly with view to threshold values, and should be considered vis-à-vis other options.
    Notes: Zusammenfassung Fragestellung: Moderne Biosensortechnologie ermöglicht die bettseitige Messung von Laktat ohne zeitliche Verzögerung. Bisherige Verfahren waren durch methodische Einschränkungen oder relevante Ungenauigkeit limitiert. Ziel vorliegender Untersuchung war zu prüfen, welche Genauigkeit mit einem neuen, direkt messenden Gerät (Chiron Diagnostics) und einem überarbeiteten bestehenden Biosensorverfahren (NOVA Biomedical) derzeit zu erreichen ist. Methodik: Untersucht wurden die Geräte „System 860” (Chiron Diagnostics) und „StatProfile 9” (NOVA Biomedical) im Vergleich zu einem etablierten photometrischen Verfahren (Analyticon). Messungen erfolgten mit 9 verschiedenen Biosensoren beider Hersteller in Zitratblut und Frischplasma als Doppelbestimmungen (n=1120), vor und nach Zugabe definierter Mengen 1molarer Na-Laktatlösung (2–24 mmol/l) sowie in kommerziell erhältlichen Qualitätskontrollösungen über einen Zeitraum von 60 Tagen. Ergebnisse: Die Reproduzierbarkeit betrug in Zitratblut 2,6±2,8% (Chiron), 4,1±4,0% (NOVA) und 1,5±2,1% (Analyticon), in Plasma entsprechend 2,1±2,4%, 2,1±2,9% und 1,0±1,1%. Die Präzision von Tag zu Tag ergab Variationskoeffizienten von im Mittel 11,5±4,9% (Chiron) und 14,0±5,9% (NOVA). Die mittlere Meßabweichung betrug für Chiron –0,2±16,4% (Plasma) und +7,2±13,1% (Zitratblut), für NOVA +9,4±18,4% und +18,7±16,7% sowie für Analyticon –37,8± 18,2% und –27,5±17,6%. Schlußfolgerungen: Das Hauptproblem der Laktatmessung mit Biosensoren ist neben der Meßungenauigkeit (im Mittel 0–18%) und dem Lebensalter der Sensoren die Größe des zufälligen Fehlers (im Mittel 13–18%). Trotz adäquat durchgeführter interner und externer Qualitätskontrollen ist es für den Anwender nicht vorhersehbar, wie sehr der angezeigte Wert von der tatsächlichen Laktatkonzentration nach oben oder unten abweicht. Folglich dürfen Absolutwerte der Laktatkonzentration nur mit Vorsicht interpretiert werden und sind zusammen mit anderen klinischen Parametern eher für die Beurteilung eines Verlaufs geeignet als für die konkrete Einschätzung des aktuellen klinischen Zustands.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Präanalytische Fehlerquellen ; Arterielle Blutgasanalyse ; Key words Pre-analytic errors ; Arterial blood-gas-analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objective: A variety of influences reduce the validity of the measured oxygen partial pressure (paO2). Most errors occur when obtaining the blood sample and preparing it for analysis. Unfortunately, there is great controversy concerning the relevance and extent of these pre-analytic errors. Apart from this, the exact estimation of influencing factors under hyperoxic conditions has been neglected. Therefore, the objective of this study was to assess pre-analytic measuring errors for paO2 under the condition of hyperoxia as completely as possible and to work out solutions to eliminate these errors. Methods: paO2 analysis was performed on more than 2000 blood samples. Errors analyzed were the technique of sample taking (direct puncture or from an indwelling catheter), aspirated air bubbles (0.05–0.35 ml), time and temperature of sample storage, and the material, size and manufacturer of the analyzing syringe. Results: The paO2 was on average 41 mmHg lower in samples taken from the indwelling catheter than by direct puncture. An air bubble size of 0.1–0.25 ml caused a decrease of 17–41 mmHg. Storage time of 2 min accounted for an paO2 reduction of 6–67 mmHg depending on the type of syringe used. Glass syringes turned out to be more accurate than plastic syringes. The best results were obtained not from commercial ”blood gas syringes” but from a simple plastic injection syringe. For all pre-analytic errors correction factors were established. Conclusion: All pre-analytic errors investigated caused a significant paO2 decrease. Even an ideal procedure (almost no air bubble, short storage on ice) contributes a significant error. Only the appropriate correction factors as calculated from this study for routine use lead to the correct results. If they are not taken into account the paO2 values will be falsely low, potentially leading to misinterpretation and misjudgement of a patient’s condition.
    Notes: Zusammenfassung Fragestellung: Die Validität der arteriellen Sauerstoffpartialdruckmessung wird von verschiedenen Faktoren beeinflußt. Die größte Anzahl von Fehlermöglichkeiten besteht in der präanalytischen Phase, in der die Probe entnommen und zur Analyse vorbereitet wird. Angaben zur Relevanz und genauen Größe der Einflußfaktoren sind sehr variabel, fehlen im hyperoxischen paO2-Bereich, der bei reiner O2-Beatmung erreicht wird, jedoch ganz. Ziel der Studie war es, diese Fehlerquellen möglichst lückenlos auf Art und Größe zu untersuchen und Verbesserungsmöglichkeiten (z.B. konstante Korrekturfaktoren) zu erarbeiten. Methodik: Mehr als 2000 Blutproben von Patienten unter kontrollierter Beatmung mit 100%igem Sauerstoff wurden auf folgende Einflüsse untersucht: Technik der Probenentnahme (direkte Punktion oder Entnahme an der arteriellen Verweilkanüle), aspirierte Luftblasen verschiedener Größe, Zeit und Umgebungstemperatur der Probenlagerung und Arten der Entnahmespritzen. Ergebnisse: Der paO2 der Blutproben aus arteriellen Verweilkanülen war im Mittel um 41 mm Hg niedriger als bei direkter Punktion. Aspirierte Luftblasen der Größe 0,1–0,25 ml erzeugten im Mittel eine paO2-Abnahme von 17–41 mm Hg. Eine Lagerungszeit von nur 2 min führte abhängig von der Umgebungstemperatur und dem verwendeten Spritzenmaterial zu einer paO2-Abnahme von 6–67 mm Hg, wobei herkömmliche Plastikspritzen genauere Ergebnisse erbrachten als kommerzielle „Blutgasspritzen”. Für alle präanalytischen Fehler wurden Korrekturfaktoren erstellt. Schlußfolgerung: Die untersuchten präanalytischen Fehlerquellen führten alle zu einer signifikanten Abnahme des paO2. Selbst durch ideales Vorgehen (kleinste Luftblasen und sofortiges Entlüften, kürzeste Lagerungszeit von 2 min in Eiswasser) konnten signifikante paO2-Meßfehler nicht verhindert werden. Daher wurden Korrekturfaktoren erstellt, mit deren Hilfe unvermeidliche Fehler nachträglich behoben werden können, da deren Vernachlässigung zu falsch niedrigen paO2-Werten und damit zu Fehlinterpretationen des Patientenzustands führen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-055X
    Keywords: Schlüsselwörter ; Präanalytische Fehlerquellen ; Arterielle Blutgasanalyse ; AaDO2 ; Key words ; Pre-analytical errors ; Arterial blood-gas-analysis ; AaDO2
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objectives: The paO2 and AaDO2 are routinely measured for evaluating pulmonary gas exchange. The normal value of the AaDO2 amounts 10 mmHg when breathing atmospheric air and is said to increase with rising FIO2. This increase is discussed controversially. One possible reason for incongruities in AaDO2 measurement may be the impact of so called preanalytical errors during paO2 measurement, which are often neglected. Therefore, the aim of this study was to evaluate the relevance of preanalytical errors on the AaDO2 under hyperoxic conditions. Methods: Arterial blood gas analysis was performed on twenty patients without known pulmonary disease after tracheal intubation and 30 min of ventilation with pure oxygen. All preanalytical paO2 errors (sam- pling technique, transport and storage of samples, aspirated air bubbles) were assessed and all paO2 measurements were corrected by applying respective predetermined correction factors. Calculation of the AaDO2 was performed with corrected and uncorrected paO2 values. Results: The average amount of the AaDO2 under ventilation with FIO2=1.0 was 118.9±41.1 mmHg, calculated from uncorrected paO2 values, and 13.4±7.5 mmHg calculated from paO2 values corrected for preanalytical errors, respectively. Conclusion: The present results show that the assumption of an increasing AaDO2 with rising FIO2 is questionable. It could be proved that neglecting preanalytical paO2 errors leads to a significant overestimation of the AaDO2. The consequence would be a misinterpretation of the patient’s condition in relation to a reduced pulmonary gas exchange, which should in fact be attributed solely to the preanalytical errors.
    Notes: Zusammenfassung Fragestellung: Sowohl der paO2 als auch die AaDO2 werden als Standardverfahren für die Beurteilung des pulmonalen Gasaustauschs herangezogen. Als „Normalwert” der AaDO2 unter Raumluftatmung werden in der Literatur übereinstimmend Werte um 10 mmHg angegeben. Kontrovers sind die Angaben jedoch für die reine O2-Beatmung, vermutlich weil die Existenz unvermeidlicher präanalytischer Fehler bei der Bestimmung des paO2 bislang nicht beachtet wurde. Ziel dieser Studie war es daher, die Auswirkungen präanalytischer Fehler bei der Bestimmung des paO2 auf die Größe der AaDO2 und damit auf deren Aussagekraft zu untersuchen. Methodik: 20 lungengesunde Patienten wurden nach endotrachealer Intubation für 30 min mit reinem O2 beatmet. Anschließend wurden arterielle Blutgasanalysen durchgeführt, und präanalytische Fehler (Art der Probenentnahme, Art der Probenlagerung, Aspiration von Luftblasen) anhand vorbestehender Korrekturfaktoren nachträglich korrigiert. Die entsprechende AaDO2 wurde dann sowohl „korrigiert” als auch „unkorrigiert” berechnet. Ergebnisse: Die AaDO2 betrug ohne Berücksichtigung der präanalytischen Fehler im Mittel 118,9±41,1 mmHg. Nach Korrektur der präanalytischen Fehler betrug sie im Mittel jedoch nur noch 13,4±7,5 mmHg. Schlußfolgerung: Nach vorliegenden Ergebnissen entspricht die Größe der AaDO2 unter reiner O2-Beatmung beim lungengesunden Patienten derjenigen unter Raumluftatmung. Die Differenz zur „unkorrigierten” AaDO2 von vorliegend 105,5 mmHg geht offensichtlich zu Lasten der präanalytischen Fehler. Wird die AaDO2 zur Beurteilung des Patientenzustands herangezogen, so müssen präanalytische Fehler beachtet und korrigiert werden. Anderenfalls würde die Interpretation einer fälschlicherweise zu hoch errechneten AaDO2 hinsichtlich der Lungenfunktion (z.B. Zunahme venöser Beimischung) lediglich auf präanalytischen Fehlern basieren.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-055X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 43 (1988), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Hepatic function was assessed pre-operatively and on the first and sixth postoperative days in 40 healthy patients who underwent prolonged maxillofacial surgery with isoflurane or halothane anaesthesia. No major changes were observed in hepatic enzymes or bilirubin. One-stage prothrombin time and Factor VII concentrations decreased on the first postoperative day and this change-was more pronounced in the halothane group. The results support the use of isoflurane rather than halothane for prolonged anaesthesia in respect of the synthesising function of the liver.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Intensivmedizin und Notfallmedizin 35 (1998), S. s036 
    ISSN: 1435-1420
    Keywords: Schlüsselwörter Hyperkapnie – CO2-Produktion – Totraum- und Minutenventilation – Hypoxämie – O2-Angebot – V/Q-Störungen – Shunt – gemischtvenöses Blut ; Key words Hypercapnia – CO2 production – dead-space ratio – total minute ventilation – hypoxemia – O2 availability – V/Q mismatching – shunt – mixed-venous oxygen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Recognizing the various complexities integral to CO2 elimination and oxygen availability establishes the need for invasive respiratory monitoring. Hypercapneic failure may be the result of several pathological factors, which include CO2 production, dead-space ratio, and total minute ventilation. The latter comprises interactive balances that include central respiratory drive, respiratory impedance, and respiratory muscle capacity. Invasive monitoring is currently available to assess each of these factors. However, some of them are primarily research tools (e.g., diaphragmatic electromyographic analyses, tensiontime index). At what level each is utilized will depend on the patient population, hospital economics, adequate nutritional plans, and a sound data base. Invasive respiratory monitoring in hypoxemic respiratory failure can lead to greater accuracy in diagnosis as well as in determining the patient's response to therapy. The level of priority depends on the patient's demands and the hospital economics. The approach to monitoring may also be based on the suspected pathophysiological etiology of hypoxemia and could include arterial, pulmonary capillary, and mixed-venous sampling, associated calculations (e.g., oxygen content), alveolar gas metering, estimation of shunt, mouth occlusion pressures, wedge pressure, stroke volume, expiratory hold, volume-time curves, and flow-time curves. Almost all standard ICUs have the capacity to determine these measurements. Most of the data are obtained as part of routine ICU management of the critically ill patient, and only few options are used by researchers (e.g., multiple inert gas elimination technique). In summary, monitoring both hypercapneic and hypoxemic respiratory failure invasively and accurately plays a crucial role in critical care.
    Notes: Zusammenfassung Aufgrund der Funktion der Atmung, Blut zu oxygenieren und Kohlendioxid zu eliminieren, führt jede Störung des respiratorischen Systems potentiell zur Einschränkung des lebenserhaltenden Zellstoffwechsels und verlangt daher frühzeitige Diagnostik und Therapie. Die zwei Hauptformen respiratorischer Störungen sind das hyperkapnische und hypoxämische respiratorische Versagen, die beide direkt oder indirekt mit einer azidotischen Reaktionslage und/oder unzureichendem O2-Angebot einhergehen können. Durch direkte invasive Messung der Atmungskapazität und der O2-Versorgung kann das respiratorische Monitoring zur Identifikation der verschiedenen hyperkapnischen und hypoxämischen Ursachen beitragen. Für das hyperkapnische respiratorische Versagen stehen dabei der pCO2, die CO2-Produktion, das Totraumverhältnis und die Gesamtminutenventilation im Mittelpunkt. Im Falle des hypoxämischen Versagens liegen die Schwerpunkte des invasiven Monitorings auf dem O2-Angebot, der alveolären Ventilation, dem Verhältnis von Ventilation und Perfusion, der Shuntberechnung und auf der Frage nach dem gemischtvenösen Sauerstoffgehalt. Die betreffenden Verfahren werden entsprechend ihrer Verfügbarkeit übersichtsartig eingeordnet und mit den jeweils wichtigsten methodischen Limitierungen dargestellt. Besonders für indirekte und abgeleitete Monitoringmethoden sind dabei eine Reihe von Fehlern zu berücksichtigen, die für Fehlinterpretationen verantwortlich sein können und deshalb ausgeschlossen werden müssen. Dies trifft besonders auf die Berechnung des O2-Gehalts zu sowie auf jene Situationen, für die aus praktischen Gründen der pO2 und/oder die sO2 bemüht werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Obstruktives Schlafapnoesyndrom ; Schlafmedizin ; Diagnostik ; Propofol ; Endoskopie ; Keywords Endoscopy ; Diagnostic use of propofol ; Sleep apnea syndrome ; Diagnosis ; Snoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Background and objective. The localization of an upper airway collapse in snorers and patients suffering from obstructive sleep apnea was a subject frequently discussed in the last few years. Pharyngolaryngoscopy during sleep or drug-induced sleep allows evaluation of upper airway conditions. Patients/methods. A total of 324 patients suffering from snoring or obstructive sleep apnea underwent flexible pharyngolaryngoscopy while awake and under propofol-induced sedation in the course of routine diagnostic procedures in the sleeping lab. In this study, the results of pharyngolaryngoscopy are compared to results of the Müller maneuver and polysomnographic recordings. The therapeutic consequences of this additional investigation are discussed. Results. In 95% of cases snoring was observed during drug-induced sleep. A significant discrepancy was seen between results of the endoscopy while being awake (Müller maneuver) and during drug-induced sleep. The degree of collapse differed significantly in the area of the base of the tongue. Severe collapse was seen much more often with pharyngoscopy during drug-induced sleep compared to the results during the Müller maneuver. Conclusions. The collapsibility in the area of the base of the tongue correlated with higher results in the RDI (respiratory disturbance index) registered with standard polysomnography. Snoring and upper airway collapse were easily surveyed, and the pharyngolaryngoscopy during propofol-induced sleep proved to be a simple, safe, readily controllable and effective supplementary diagnostic device for the diagnosis and treatment of obstructive sleep apnea and snoring.
    Notes: Zusammenfassung Hintergrund und Fragestellung. Die Vorhersage des Ortes der Obstruktion oder des Weichteilkollapses bei Patienten mit primärem Schnarchen und obstruktivem Schlafapnoesyndrom war in den letzten Jahren häufig Thema von Untersuchungen. Die flexible Nasopharyngolaryngoskopie im Schlaf oder in Sedierung ist in diesem Zusammenhang eine bekannte Untersuchungsmethode, trotz ihrer nichtphysiologischen Basis. Patienten/Methodik. Die Ergebnisse von 324 Patienten, die neben der Routinediagnostik im Schlaflabor mittels einer flexiblen Pharyngolaryngoskopie im Wachzustand und in Propofol-Sedierung untersucht wurden, werden beschrieben. Hierbei werden Vergleiche zum Müller-Manöver und zu den jeweiligen Polysomnographieergebnissen angestellt und die therapeutische Konsequenz dieser Zusatzdiagnostik diskutiert. Ergebnisse. In 95% der Fälle konnte während des medikamentös induzierten Schlafs Schnarchen registriert werden. Auf Höhe des Zungengrunds fand sich eine signifikant stärkere Kollapsneigung bei der Untersuchung im Propofol-Schlaf verglichen mit den Befunden des Müller-Manövers. Die Stärke des Zungengrundkollapses korrelierte mit dem in der Polysomnographie ermittelten RDI (respiratory disturbance index). Schlussfolgerungen. Insgesamt fand sich ein deutlicher Unterschied zwischen der Ausprägung des Weichteilkollapses beim Müller-Manöver und beim Propofol-Schlaf; Schnarchen und Kollapsneigung ließen sich zuverlässig beobachten. Die Pharyngolaryngoskopie erwies sich als einfach und sicher durchführbare, komplikationsarme und aussagekräftige Zusatzdiagnostik im Rahmen der Abklärung des primären Schnarchens und des obstruktivem Schlafapnoesyndrom.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Sensorineurale Schwerhörigkeit ; Plötzliche Taubheit ; Anästhesie ; Komplikationen ; Key words Sensorineural hearing loss ; Sudden deafness ; Anesthesia-related complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Acute hearing loss following non-otologic surgery and general anesthesia is a rare occurrence. Deafness following anesthesia has more commonly been associated with spinal anesthesia or cardiopulmonary bypass surgical procedures. We present a case with unilateral cochlear dysfunction and sensorineural hearing loss after inguinal hernia operation. The literature is reviewed and the mechanisms causing hearing loss during anesthesia are discussed.
    Notes: Zusammenfassung Druckveränderungen des Mittelohrs mit vorübergehender Hörminderung zählen zu den Begleiterscheinungen von Ohroperationen, insbesondere im Zusammenhang mit der Verwendung von Lachgas oder positiver Beatmungsdrücke während Maskenbeatmung im Rahmen der Narkose. Ein akuter sensorineuraler Hörverlust ist eine bekannte Komplikation nach Spinalanästhesien oder kardiopulmonalen Operationen. Es sind allerdings nur sehr wenige Fälle mit einer Innenohrschwerhörigkeit bzw. Taubheit nach nicht otochirurgischen Eingriffen in Intubationsnarkose und bei Patienten ohne otologische Vorerkrankungen beschrieben. Wir berichten von einem Patienten mit postoperativer Surditas und sensorineuraler Schwerhörigkeit in der Folge einer Leistenhernienoperation in balancierter Anästhesie. Nach Durchsicht der Literatur werden mögliche Ursachen und Faktoren dieses postoperativen Hörverlusts diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...