Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 81 (1997), S. 5021-5023 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Coupling of soft magnetic films to antiferromagnetic substrates was studied by spin-polarized secondary electron microscopy. Permalloy (Ni80Fe20 alloy) films were deposited on antiferromagnetic NiO(111) single-crystal substrates. A domain structure consisting of fine grains (∼50 μm) was characteristic of the NiFe film deposited without applying magnetic field. The domain image and its response to applied field suggested existance of local easy axis and local unidirectional anisotropy. When macroscopic unidirectional anisotropy was introduced to the NiFe film by depositing under an applied dc magnetic field, many of the fine grains disappeared and the film showed large domains (∼1 mm). In the large domains, small elongated reversed domains (∼20 μm×60 μm) aligned parallel to each other implying local easy axis of magnetization. The type of domain behavior described above was not observed in a NiFe film on MgO(111) substrate that had the same crystal structure as NiO but no magnetic ordering. An x-ray analysis revealed that the local easy axes observed in NiFe/NiO specimens coincided with the [112¯] of the NiO crystal lying in the (111) substrate plane, which supported coupling of the NiFe film with the single-crystal substrate. © 1997 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 79 (1996), S. 5057-5059 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Nanometer-scale mounds were fabricated by applying voltage pulses between a substrate and an atomic force microscope cantilever coated with magnetic material. Mounds were formed on both insulator and conducting substrates. Magnetic force microscopy (MFM) observations of the fabricated mounds were performed, and the contrast was turned over by reversing the magnetization of the tip, which is convincing proof that the mounds are magnetic. The MFM images also suggest that the mounds are perpendicularly magnetized. These results demonstrate that scanning probe microscope based nanofabrication is a promising method to fabricate nanoscale magnetic dots on any kind of substrates. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 52 (1996), S. 787-796 
    ISSN: 1600-5724
    Quelle: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Thema: Chemie und Pharmazie , Geologie und Paläontologie , Physik
    Notizen: In cubic polycrystals, combinations of coincidence orientation relationships at a triple junction of grains A, B and C can be obtained by using the equation ΣCA = ΣABΣBC/d2, where d is a common divisor of ΣAB and ΣBC. This paper describes the derivation of this equation and shows several models of polycrystals composed of specially selected coincidence boundaries using the above equation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Emergency radiology 6 (1999), S. 204-209 
    ISSN: 1438-1435
    Schlagwort(e): Key words Neoplasms ; Hemorrhage ; Perforation ; CT ; Abdomen ; Pelvis.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Rupture of tumors is usually a critical and life-threatening condition. We demonstrate a wide variety of ruptured tumors with their imaging characteristics including gastric lymphoma, gastric leiomyosarcoma, leiomyosarcoma of the ileum, hepatocellular carcinoma, pancreatic pseudocyst, renal angiomyolipoma, renal cell carcinoma, ovarian endometrial cyst, ovarian corpus luteum cyst, and ovarian teratoma. Their imaging features are illustrated with an emphasis on clues to an accurate diagnosis.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1433-4909
    Schlagwort(e): Key words Thermophilic enzymes ; 3-Isopropylmalate dehydrogenase ; Thermostability ; Thermus thermophilus ; Chimeric proteins ; Interdomain interaction ; Differential scanning calorimetry
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie
    Notizen: Abstract In our previous study, we showed that a chimeric isopropylmalate dehydrogenase, 2T2M6T, between an extreme thermophile, Thermus thermophilus, and a mesophile, Bacillus subtilis, isopropylmalate dehydrogenases (the name roughly denotes the primary structure; the first 20% from the N-terminal is coded by the thermophile leuB gene, next 20% by mesophile, and the rest by the thermophile gene) denatured in two steps with a stable intermediate, suggesting that in the chimera some of the interdomain interaction was lost by amino acid substitutions in the "2M" part. To identify the residues involved in the interdomain interactions, the first and the second halves of the 2M part of the chimera were substituted with the corresponding sequence of the thermophile enzyme. Both chimeras, 3T1M6T and 2T1M7T, apparently showed one transition in the thermal denaturation without any stable intermediate state, suggesting that the cooperativity of the conformational stability was at least partly restored by the substitutions. The present study also suggested involvement of one or more basic residues in the unusual stability of the thermophile enzyme.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 1437-9813
    Schlagwort(e): Key words Necrotizing enterocolitis (NEC) ; Terminant ; Coarctation ; Coarctation of aorta (CoA) ; Ductus arteriosus (DA)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  Necrotizing enterocolitis (NEC) sometimes occurs in term infants with congenital heart disease. This article reports a rare case of a term infant with coarctation of the aorta complex who developed NEC on the 8th day after birth. Spontaneous closure of the ductus arteriosus in the 1st week of life may cause intestinal ischemia and hypoxia with resultant NEC.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1437-9813
    Schlagwort(e): Necrotizing enterocolitis (NEC) ; Terminant ; Coarctation Coarctation of aorta (CoA) ; Ductus arteriosus (DA)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Necrotizing enterocolitis (NEC) sometimes occurs in term infants with congenital heart disease. This article reports a rare case of a term infant with coarctation of the aorta complex who developed NEC on the 8th day after birth. Spontaneous closure of the ductus arteriosus in the 1st week of life may cause intestinal ischemia and hypoxia with resultant NEC.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 1437-9813
    Schlagwort(e): Key words Patent omphalomesen teric duct ; Transumbilical approach ; Umbilical plasty
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract This paper describes a transumbilical resection and umbilical plasty for treatment of a patent omphalomesenteric duct (POMD). In a newborn infant with a POMD, a skin incision was made circumscribing the mucocutaneous junction of the protruded duct. The duct was completely extirpated with a wedge resection of the connection to the intestine and an umbilical plasty was performed. The postoperative appearance was excellent. It appears that transumbilical resection and umbilical plasty may be a satisfactory operation for POMD.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1437-9813
    Schlagwort(e): Intestinal volvulus ; Infarcted volvulus ; Prenatal ultrasonography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract This article describes a prenatal ultrasonographic finding of an infarcted intestinal volvulus. Ultrasonography showed polyhydramnios, multiple dilated intestinal loops, increased transverse abdominal area, and ascites. After cesarean section due to premature rupture of membranes and fetal distress, derotation of the infarcted volvulus caused postoperative thrombocytopenia, hyperkalemia, and acidosis and a subsequent resection was required. A high output of intestinal juice from the jejunostomy caused severe hypovolemia and electrolyte imbalance with resultant death. Increased transverse abdominal area caused by marked intestinal dilatation, ascites, fetal distress, and hydrops fetalis may suggest an infarcted intestinal volvulus.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1437-9813
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract This paper reports a premature infant with a congenital diaphragmatic hernia (CDH) who underwent an abdominal wall plasty to enlarge the abdominal cavity, one of twin infants born at 32 weeks weighing 1,255 g. After stabilization, the herniated viscera were reduced from the pleural cavity and the abdominal wall muscle and skin layers were replaced by a Gore-tex patch without closure of the diaphragmatic defect. Respiratory and circulatory conditions were stable during the perioperative period. Postoperatively, a roentogenogram showed expansion of the lung. However, his condition deteriorated 24 h after surgery, triggered by intratracheal suction, and he died on the 4th day of life despite the use of high-frequency oscillation, catecholamines, and vasodilators. Postmortem examination showed severely hypoplastic lungs. Abdominal wall plasty may be a less invasive initial procedure, however, further studies, such as comparison with the standard method or conservative management, are needed using a large clinical group or animal models to justify the usefulness of this procedure.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...