Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2,339)
  • 1980-1984
  • 1960-1964
  • 1993  (2,339)
  • Analytical Chemistry and Spectroscopy  (1,600)
  • Computational Chemistry and Molecular Modeling  (478)
  • Physical Chemistry  (218)
  • Gas chromatography
  • Nuclear reactions
Material
Years
  • 1990-1994  (2,339)
  • 1980-1984
  • 1960-1964
Year
Keywords
  • 1
    ISSN: 1432-2285
    Keywords: Abies alba ; Abscisic acid ; Damage ; Gas chromatography ; Needles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary The amount of abscisic acid (ABA) in needles of silver fir from a natural location was investigated with regard to position in the crown, damage, seasonal variation, and needle age. Because of problems of quantification of ABA in coniferous needles, which contain numerous secondary plant products, a method for reliable determination of both isomers cis-trans-ABA (c-ABA) and transtrans-ABA (t-ABA) was developed. By means of gas chromatography (GC) using an electron capture detector (BCD) and a programmed temperature vaporizer (PTV) injector complete separation of both compounds was achieved. Two different pairs of fir were investigated — in each case a damaged and a healthy tree. Needles from both trees from the first and the second pair collected in September contained 500–1100 ng c-ABA/g fresh weight (FW), and the concentrations of t-ABA varied from 400 to 700 ng/g FW. Investigations from the second pair show highest amounts of 2900 ng/g Fw c-ABA and 1800 ng/g FW of t-ABA in May and June. For the first pair a higher c-ABA content was found in needles from the top of the crown than in those from the middle and the base. This difference could not be confirmed in the analysis of the second pair. Because of the strong natural deviation no statistically significant difference between the healthy and the damaged tree was found. The first pair of firs examined showed a higher t-ABA concentration than the second one. In this case the highest amount was found in the top of the crown. Methodical mistakes during the clean-up procedure and in quantification by gas chromatography could be excluded. The presence of c- and t-ABA in the purified extract was corroborated by mass spectrometry. With regard to the seasonal variation both isomers of ABA show an unequivocal trend. The maximum concentration is achieved in May to June, whereas the content is minimal in August/September. In any case the level of t-ABA is lower than that of c-ABA. No correlation between the amount of ABA and the needle age could be established.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 64 (1993), S. 503-507 
    ISSN: 1432-1246
    Keywords: Biological monitoring ; Carbon disulphide ; Dithiocarbamate ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Blood carbon disulphide (CS2), both free and total, was determined by gas chromatography-mass spectrometry in 112 “normal” subjects and in 20 subjects employed in a dithiocarbamate factory, comprising ten blue-collar workers involved in dithiocarbamate production and ten white-collar office staff. The ten production workers were examined over two workshifts, the first at the beginning of the week (Monday) and the second after an intervening period of at least 1 day. Three blood samples were taken for each shift studied, one prior to starting work, one at the end of the shift and the third 16 h after the end of the shift (on the following morning). The mean CS2 blood levels measured in the 112 normal subjects was 663 ng/l for the free fraction and 3178 ng/l for the total. In 16 blood samples taken from the ten dithiocarbamate factory office workers, the mean free and total CS2 blood levels were 846 and 4140 ng/l, respectively, i.e. not significantly different from those observed in the normal subjects. At the end of the first 8-h shift, the ten dithiocarbamate factory production workers had free and total CS2 values of 1070 and 8471 ng/l, respectively, which were significantly higher than those observed prior to starting work (240 and 4738 ng/l). All the total CS2 levels measured in the shop-floor workers, with the sole exception of the values recorded prior to the start of the Monday shift (4738 ng/l), ranged from 7047 to 8471 ng/l and were significantly higher than those measured in the white-collar staff (4140 ng/l).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1246
    Keywords: Acrylonitrile ; Adducts ; Biological monitoring ; Gas chromatography ; Hemoglobin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new, simple and fast procedure of measuring acrylonitrile (ACN) in ACN derived mercapturic acids such as S-(2-cyanoethyl)-L-cysteine(CyEC), and in hemoglobin (Hb) and plasma protein adducts and urinary metabolites in rats and humans exposed to ACN was developed. ACN in mercapturic acids or proteins was analyzed by capillary gas chromatography (GC) by liberating ACN at a high-temperature in the injector port of GC with or without oxidizing sulfur atoms of the ACN-bound cysteines into sulfoxide form by hydrogen peroxide in vitro. At 350 °C, more than 90% of ACN in authentic CyEC was recovered by this method. Increasing a single ip dose of ACN from 5 to 50 mg/kg produced proportional increases in ACN bound to Hb 24 hr after the treatment. The alkylation of plasma protein with ACN was about 1/10 as low as that of Hb. After repeated daily ip doses of 1–10 mg/kg, ACN in Hb decreased with a half-life of about 9 days. ACN was also detected in the blood of workers exposed to ACN for 1 to 10 years at a Siberian synthetic rubber factory.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0738
    Keywords: Pigment Yellow 17 ; 3,3′-Dichlorobenzidine ; Biotransformation ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Rats were exposed by inhalation to the technically highest administrable concentration of 230 mg Pigment Yellow 17/m3 air for 4 h. Inhalability of the dust was guaranteed by a mass-median aerodynamic diameter of 1.0–1.1 μm. For 14 days after exposure, urine and serum samples were analysed for 3,3′-dichlorobenzidine, the parent carcinogenic amine of the test compound. No 3,3′-dichlorobenzidine could be detected either in urine or blood, the detection limit being 5 ng/ml for both media. Based on the results of this study there is no evidence for metabolic cleavage of Pigment Yellow 17 to 3,3′-dichlorobenzidine in the rat.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 649-652 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Triglycerides in cheese ; Programme temperature (PTV) injection ; Silica capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid gas chromatographic method for the analysis of triglycerides in cheese on a capillary column with a programmed temperature vaporizer has been developed. Fat were extracted with hexane to dryness. The reproducibility of the method was assessed and the coefficient of variation for the total triglycerides was 2.50%. Recovery of individual triglycerides ranged between 87 to 105%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Curie-point pyrolysis ; Multivariate analysis ; Sodium dodecylbenzene sulfonate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Multivariate analysis can be applied to quantitative analysis of sodium dodecylbenzene sulfonate (DBS) by pyrolysis gas chromatography. The pyrograms obtained from mixtures of DBS and polyoxyethylene lauryl ether (PEG) were normalized for the peak heights and areas of several internal standards which appeared in every pyrogram, against the characteristics peaks for DBS and PEG. This normalization method gave smaller experimental errors than when using one internal standard. The normalization values were used for cluster analysis unchanged. The values were calculated correlation coefficients and principal component analysis was performed using 11 data base and a set of sample data simultaneously. One calibration curve was calculated from the principal component scores. The DBS content of a sample was obtained from the calibration curve. Calculated values were in fair agreement with theoretical values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 36 (1993), S. 187-190 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid-phase extraction disks ; Pesticides ; Soil analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A systematic study comparing the methodology and analytical results obtained in an investigation of seven pesticide residues (Molinate, Atrazine, Carbofuran, Pirimicarb, Prometryn, Malathion and Tetrachlorvinphos) in soil samples is reported. Solid-phase extraction (SPE) using glass columns and 47 mm disks of octyl and octadecyl-bonded silica was used in the pesticide analysis. The best extraction efficiency and clearest extracts are obtained with C8 disks. The analyses were carried out by capillary gas chromatography with nitrogen and phosphorus detection. Recovery experiments were performed at ppb levels in spiked soil samples. The average recoveries of the compounds were 53–77%. Detection limits are between 5 and 30 ng g−1 based on 5 g moist soil sample. The method was validated by comparing it with conventional liquid-liquid extraction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Fatty acid methyl esters ; Diesel fuel substitute ; Glycerol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A GC method for the determination of free glycerol in vegetable oil methyl esters used as diesel fuel is described. The sample preparation includes dissolving in dimethylformamide, silylation with bistrimethylsilyltrifluoroacetamide (BSTFA) and separation on a methyl silicone capillary column using either FID or MS detection. The recovery was tested using standard samples containing known amounts of glycerol. The results of the analysis of different samples were compared with those obtained by enzymatic determination. The method described offers a far more sensitive and quick determination of free glycerol compared to other methods.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Electron capture detection ; Trichothecenes ; Cereal grain
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Various analytical methods developed for trichothecene determination, including TLC, HPLC, GC, supercritical fluid chromatography (SFC) and enzyme immuno assay (EIA) are reviewed. In addition a new method is described for the simultaneous determination of the trichothecene mycotoxins deoxynivalenol (DON), nivalenol (NIV), 3-acetyldeoxynivalenol (3-ADON), diacetoxyscirpenol (DAS), T-2 toxin (T-2), HT-2 toxin (HT-2) and T-2 triol (TRIOL), in Austrian wheat and corn samples by GC-ECD. A clean-up procedure has been developed using a combination of liquid-liquid and liquid-solid extraction. Trichothecenes were detected as their heptafluorobuturyl esters or alternatively as trimethylsilyl ethers (only sensitive for deoxynivalenol and nivalenol) using nandrolone or chloramphenicol as internal standard. Four derivatization techniques using HFBI, HFBA+DMAP on polystyrene, TMSI and TMSI+BSA+TMCS have been studied and the advantages and disadvantages of each are discussed. Quantification of trichothecenes from 10 to 1000 ppb in cereals could be accomplished routinely.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 37 (1993), S. 215-217 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Unified retention indices ; Dimethylsiloxane stationary phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic, unified retention-indices of 56 alkylbenzenes up to C15 on dimethylsiloxane OV-101 and SE-30 stationary phases are given. These values agree well with the corresponding experimental values used in the statistical treatment of the experimental data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 37 (1993), S. 259-263 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Quantitative analysis ; Ethylene oligomer by-products ; n-Alkanes, n-alkenes and 2-alkyl-1-alkenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method using temperature-programmed poly-dimethylsiloxane OV-101 and poly(pheny ether) (5 rings) capillary columns was developed to separate and quantify the reaction by-products in ethylene oligomers. It was found that the content of 2-alkyl-1-alkenes, 2-alkenes and n-alkanes in the C8−C18 α-olefin fractions amounts to 29, 10 and 2.6% respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 37 (1993), S. 211-214 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Organic solvents ; Routine analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A gas chromatographic method for the analysis of organic solvents in chemical products is described. The analysis is performed by the use of a polar column, Supelcowax 10, and a non-polar column CP-Sil-5CB. Samples containing a non-volatile matrix or water were analysed by headspace analysis. The identification of the solvents in a sample, based on GC retention times on one column, is confirmed by GC of the sample on the second column. The method has been found to be suitable for the routine analysis of solvent mixtures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 37 (1993), S. 264-270 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Temperature programmed ; Peak widths ; Polynomial interpolation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Isothermal chromatographic measurements lead directly to ΔH v o and A (entropy term) of solutes, and three constants of an empirical relationship between peak width and column temperature. From the thermodynamic parameters ΔH v o and A retention temperatures have been computed by means of a theoretical model including temperature dependence of carrier gas viscosity, and subsequently retention times; programmed retention indices have been determined by linear and polynomial interpolations. By substituting the value of the calculated retention temperature in the above-mentioned relationship, peak width at half-height for a linear temperature may be estimated. Predicted retentions correlate with observed data, with a P-value ≤0.01; simulation accuracy is generally 6–10% for peak widths. Retention indices of some organochlorine species, separated on an OV-101 capillary column, may differ by as much as 26 units depending on the method of calculation. Polynomial-calculated indices are more consistent with the retention index scheme, and have smaller standard deviations and better constancy at different heating rates.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Inverse gas chromatography ; Poly(ethylene glycol) 20M ; Retention mechanisms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The properties of poly(ethylene glycol) 20M (PEG 20M) coated on the hydroxylated surface of Chromaton N AW were investigated by inverse gas chromatography. It was found that the solid form of PEG 20M exhibits partition as the retention mechanism even below its melting range. The contribution of adsorption to the specific retention volume was also determined. It was demonstrated that inverse gas chromatography establishes the existence of a polymer surface layer but precise determination of its thickness is difficult. The limitation of the applicability of inverse gas chromatography results from the structure of the investigated surface layer which is thin and not coherent so that solute molecules can penetrate it.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 33-37 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Crown ether polysiloxane phases ; Selectivity mechanisms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The phase recognition mechanism of nine groups of position isomers on four crown ether polysiloxanes, OV-1701 and PEG 20M has been investigsated by measuring various thermodynamic parameters. The high selectivity of crown ether polysiloxane phases is due to hydrogen bonding and the extent of fitting between the analytes and the crown ethe cavity. The effects on selectivity of cavity size, heteroatoms and substituent groups on the crown ether are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Equilibrium headspace sampling ; Partition coefficient determination ; Theory of chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The new phase ratio variation method is described which represents a convenient way for the determination of gas-liquid partition coefficients for practical purposes, utilizing equilibrium headspace-gas chromatography (EHS-GC). This method is based on the relationship between reciprocal peak area and the phase ratio in the vial containing the sample solution; it involves regression analysis of the EHS-GC measurements of a number of sample vials containing the same sample solution but with a wide variation of phase ratios. Examples are given for both aqueous systems and systems consisting of a stationary (liquid) phase used as the solvent; comparison of the measured values with results obtained by other methods shows satisfactory agreement. A critical discussion of the conditions influencing the accuracy of the analytical results is given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 109-110 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Unified retention index ; Correlation of data ; Hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic unified retention indices for 43 hydrocarbons (alkanes and cycloalkanes) are given for squalane and OV-101. Comparison of these values and unified retention index increments are presented as linear regression equations with high correlation coefficients and acceptable standard deviations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 160-166 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Neural networks ; Classification ; Pattern recognition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Artificial Neural Networks are proposed for the classification of vegetable oils submitted to gas chromatography analysis through their FAME profiles. Three important neural networks are evaluated here: the Hopfield model as a content-addressable memory (CAM), the Hamming model and the multi-layer perceptron. A brief description of these nets is first presented and further implemented for the classification of known vegetable oils. After the learning step, unknown samples are presented to the nets and the identification step performed. The performances of these nets are compared for the recognition of popular vegetable oils, including several edible oils.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Mass spectrometry ; Atomic emission spectroscopy ; Pulp mill effluents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Three chlorinated dimethyl sulfones and five chlorinated thiophenes have been identified in the alkaline extraction liquor from a bleach plant by gas chromatography with atomic emission detection (GC-AED) and with mass spectrometry (GC-MS). The information on elemental content obtained by GC-AED enabled a rapid screening of the sulfur compounds and provided important structural information complementary to the mass spectral data. Quantitation was accomplished by GC-AED based on universal calibration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 209-215 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas chromatography-mass spectrometry ; Tagetes ; Plant volatiles ; Extractions ; Natural insecticides ; Mosquitos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Volatiles from three species of the genustagetes, commonly called marigold have been isolated and characterized. Simultaneous steam distillation extractions (SSDE) produced consistently extracts of higher insecticidal activity than Soxhlet extractions. Methylene chloride was the best solvent. Volatiles isolated from theminutae species showed higher activity than those frompatula anderecta. Comparison of extracts from the flower, foliage and roots of the plant showed that most of the activity is located in the flower. The volatiles are highly effective toward both larvae and adult mosquitoes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 237-240 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Enantioselectivity ; Polysaccharide chiral stationary phase ; Amylose tris(n-butylcarbamate) ; Grob test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Seven aromatic and alkyl amylose and cellulose carbamates have been tested as chiral stationary phases in gas chromatography. One of them, amylose tris(n-butylcarbamate) can be used for enantiomer separation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 290-294 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Solid phase extraction ; Organochloride pesticides ; Water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatography of chlorinated pesticides in water is carried out after adsorption of a 50 mL sample using a cartridge containing 100 mg CN-bonded porous silica and extraction with 500 μL pentane. The average recovery for eight organochloride pesticides at 1 ppb was 〉95%. The procedure described is simple, selective and reproducible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 35 (1993), S. 339-343 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preconcentration techniques ; Trace gas analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The blanks in preconcentration methods for determining trace amounts of impurities in ultra-pure gases, which include the preconcentration volume of sample gases, carrier gas impurities and atmospheric contamination are discussed and three concentration methods for eliminating blank errors are proposed. These are, the differential volume method by concentrating at the same flow-rate but different times (DVMSF), the differential time method by concentrating the same volumes at different flow-rates (DTMSV) and the differential volume method by concentrating for the same times but different flow-rates (DVMST). DVMST is proposed as the best method for its ability to eliminate all blank errors described. The methods are used to determine trace amounts of Ar+O2 and N2 in ultra-pure hydrogen. Calculations demonstrate that the methods can effectively improve analytical accuracy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Micropacked columns ; Retention behavior ; LC silica packing materials ; Silanol groups
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas chromatographic retention of cyclohexane and benzene on microcolumns packed with silica-based materials for liquid chromatography has been investigated to elucidate the relationship with the surface properties of the packing materials. Differences in capacity factors (Δk′) for these two hydrocarbons were related to the surface area of the packing materials. For untreated silica gels, the Δk′ value increased with increasing total surface area of the column employed and measurement of Δk′ for chemically-bonded stationary phases allowed estimation of accessible residual silanol groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Pesticides in groundwater ; Solvent extraction ; Multiresidue analysis ; Selective detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple multi-residue procedure has been developed and applied to the analysis of pesticides in groundwater samples from the Comunidad Valenciana, a predominantly agricultural area on the Mediterranean coast of Spain. The procedure includes a liquid-liquid extraction, after addition of NaCl on the samples, and a subsequent analysis by capillary gas chromatography using a dual detection system with electron capture and nitrogen-phosphorous detectors. This allows the determination of more than 30 compounds (organophosphorous, organochlorine and pyrethroid pesticides) at the low ppb (μg l−1) levels. Detection limits obtained varied between 0.01 μg l−1 (lindane, fonofos) and 0.5 μg l−1 (cypermethrin). An additional injection of the sample extracts into a gas chromatograph equipped with a column of different polarity and electron capture detector is used for the confirmation of chromatographic peaks. The recommended procedure has been applied to 66 ground water samples. Pesticides, including organophosphorus and organochlorine compounds were detected in 31 of them, in levels ranging from 0.02 to 0.7 μg l−1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Headspace sampling ; PTV-System ; Ethephon in drinking water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An indirect GC method is described for the determination of Ethephon in drinking water on the basis of the headspace analysis of the ethylene formed from Ethephon. In order to reach the necessary detection limit, the entire volume of the static headspace distribution is transferred into a cold injection system (CIS). There, the ethylene is adsorbed on Carbosieve SIII at 10°C and, subsequently, desorbed at 300 °C. The water vapour included in the headspace is completely eliminated through the splitting system. By means of this technique, a detection limit of 0.05 μg/l water was reached.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 37 (1993), S. 399-401 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Viscosity ; Carrier gases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equations are derived for viscosities of H2, He, N2 and Ar for use at chromatographic temperatures which are accurate to within 0.3% for H2, and 0.1% for the other gases. The effect of pressure is usually negligible but may increase the viscosity of N2 or Ar by as much as 0.5% at 25°C or lower and 5 atm or higher.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Analytical methods have been developed for the simultaneous quantitation of azelastine (AZ) and desmethylazelastine (DAZ) in guinea pig plasma and lung tissue. The methods require a 1.00 mL plasma sample and a minimum 0.100 g lung sample. Both methods employ liquid/liquid organic extraction and back-extraction into dilute acid. Quantitation is performed by high performance liquid chromatography on a 2X250 mm 5 μm HypersilTM CPS column using fluroescence detection. The linear quantitative ranges for AZ.HCI and DAZ.HBr in plasma are 0.156-160 ng/mL and 0.313-160 ng/mL, respectively. The linear quantitative ranges for AZ.HCI and DAZ.HBr in lung tissue are 0.039-20 μg/g for both.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A rapid, sensitive and simple to operate high performance liquid chromatographic method for the simultaneous determination of morphine, morphine-3-glucuronide and morphine-6-glucuronide in plasma is described. The drug and its metabolites were extracted from plasma using commercially available reversed phase octylsilane bonded silica columns (1 mL Bond Elut C8, 50 mg). Chromatographic separation of morphine and its metabolites was achieved using a mobile phase, consisting of 2 mM sodium dodecyl sulphate in 0.05% phosphoric acid:acetonitrile (71.5:28.5 by volume), at a flow-rate of 1.2 mL/min, in conjunction with a Waters Nova-Pak C18 column (300 × 3.9 mm). The analytical column was used in combination with a Guard-Pak module containing a Nova-Pak C18 Guard-Pak insert. Using fluorescence detection (excitation 245 nm, emission 335 nm), plasma levels in the region of 5-10 μg/L for the drug and its metabolites can be detected with only 200 μL of plasma. The method has been applied to studies of the disposition of morphine and its metabolites in premature neonates requiring mechanical ventilation who were receiving the drug intravenously; preliminary findings in patients at steady state are presented.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A multidimensional column chromatographic method involving electrochemical detection using a carbon fibre microelectrode flow cell was optimized and successfully applied to the simultaneous determination of salbutamol and terbutaline in plasma at overdose levels. This method performs, in a single step, an efficient extraction and clean-up of salbutamol and terbutaline from human plasma. The calibration graphs over three days were linear over the calibration range 20-100 ng/mL plasma with a limit of detection of 1 ng and 0.8 ng/mL plasma for salbutamol and terbutaline, respectively. The intra- and inter-assay coefficients of variation were less than 8% and the recoveries ranged from 94 to 96%. The accuracy of the assay, which was defined as the percentage difference between the mean concentration found and the theoretical concentration, was 7% or better. The proposed method combines the advantages of being simple, reproducible and selective in the presence of other sympathomimetic and commonly ingested drugs and is suitable for routine analyses to obtain valuable information about the clinical effects and treatment of overdose with these drugs. The whole procedure takes ca. 10 min and compares favorably with detection at a conventional glassy carbon electrode.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 181-183 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic method has been developed for the determination of rafoxanide and closantel in ovine plasma. Acetonitrile and chloroform were used for the extraction. The mean recoveries were 78.69% and 80.59% for rafoxanide and closantel, respectively. This method was applied to the characterization of rafoxanide plasma kinetics following oral administration of therapeutic doses to sheep.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The separation of reduced and oxidized glutathione at an absolute sensitivity of about 100 pg by micellar electrokinetic capillary chromatography without derivatization is described. The time required for the separation is less than 10 min (the time between two following injections is about 15 min). The separation is characterized by high efficiency and good reliability. A partition mechanism is responsible for the high resolution observed. The method was utilized for the analysis of commercial preparations of glutathione and a good agreement with the expected results was obtained; the oxidation of the commercial glutathione in solution was easily analysed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 235-250 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Application of HPLC as a prime tool in the area of enantiomeric resolution has opened doors of success and varied interest. Use of chiral reagents either indirectly (as derivatization reagent) or directly (added to stationary or mobile phase) has led to achieve resolution of a wide range of compounds. Amino acids, being important molecules with simple structure and easy availability, have been extensively studied. A bibliographic survey on HPLC resolution of amino acids and derivatives along with a brief discussion on general methods of enantiomeric separation has been presented.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. ii 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 275-276 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: L- and D-Amino acids (Leu or Phe) were derivatized with fluorogenic reagents, 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F), 4-aminosulfonyl-7-fluoro-2,1,3-benzoxadiazole (ABD-F) and 5-(N,N-dimethylamino)naphthalene-1-sulfonylchloride (DNS-Cl), and separated on a Pirkle type column, Sumichiral OA 2500 (S) ((S)-1-naphthylglycyl-3,5-dinitrophenylamide silica gel) with a mobile phase of 20 mM ammonium acetate in methanol. The fluorometric detection of the derivatives was made at 530 nm, 590 nm and 530 nm with excitation at 470 nm, 450 nm, 450 nm and 350 nm, respectively. The former three derivatives of the enantiomers were separated well from each other; The as for each NBD-, DBD- and ABD-derivative of L- and D-Leu were 1.10, 1.11 and 1.10, respectively. However, the DNS derivatives of L-and D-Leu were not separated (separation factor, α = 1.0). All NBD- and ABD-derivatives of L- and D-Phe were also well separated (αs were 1.18, 1.17 and 1.16, respectively), while DNS-L- and -D-Phe were barely separated (α = 1.04). These data suggest that the 2,1,3-benzoxadiazole (benzofurazan) moiety is very effective and preferable to the dimethylaminonaphthalene sulfonyl (DNS) structure for the separation of enantiomers of amino acids derivatized with benzofurazan reagents.No recemization of each enantiomer occurred during the derivatization reaction with NBD-F, DBD-F and ABD-F at pH 8.0 and 60°C for 2 min, at pH 9.3 and 60°C for 30 min and pH 9.3 and 60°C for 60 min, respectively, meaning that all benzofurazan type fluorogenic reagents are useful for sensitive determination of amino acid enantiomers.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: This report details a very sensitive, rapid and accurate ion-pair HPLC-ECD method for the analysis of biogenic amines and their metabolites in brain tissue. The method described enables detection of picogram amounts of 3-methoxy-4-hydroxy phenethyleneglycol (MHPG) (37 pg), 3,4-dihydroxy phenylacetic acid (DOPAC) (18 pg), norepinephrine (NE) (12 pg), epinephrine (E) (6 pg), 5-hydroxyindoleacetic acid (5-HIAA) (18 pg), 3,4-dihydroxyphenylethylamine (DA) (6 pg), 3-methoxy-4-hydroxyphenylacetic acid (HVA) (12 pg) and 5-hydroxytryptamine (5-HT) (12 pg). The linearity of the method is from 18.75 ng/mL to 300 ng/mL for MHPG; 9.37 to 150 ng/mL for DOPAC and 5-HIAA; 6.25 to 100 ng/mL for NE, HVA and 5-HT; and from 3.12 to 100 ng/mL for E and DA. The reproducibility, expressed as coefficient of variance (CV%) within-run and between-run groups, was 2.25% and 19.49% for MHPG; 3.84% and 29.84% for DOPAC; 0.89% and 8.97% for NE; 1.26% and 5.61% for E; 1.07% and 28.77% for 5-HIAA; 2.65% and 10.65% for DA; 5.97% and 24.38% for HVA; and 4.44% and 9.45% for 5-HT.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A procedure for the extraction and high performance liquid chromatographic (HPLC) determination of the photodynamic therapeutic agent 5,10,15,20-tetra(m-hydroxyphenyl)chlorin in human, rat and mouse tissues following intravenous administration of the drug is described. The tissue (tumour, skin, muscle and liver) was homogenized and extracted into a mixture of methanol:dimethyl sulphoxide:water (32:8:1 by vol.) containing, 5,10,15,20-tetra(p-hydroxyphenyl)chlorin as the internal standard. The precipitated proteins were removed by centrifugation and the supernatant was separated by reversed phase HPLC on a Hypersil-ODS column with 77% (v/v) acetonitrile in 0.1% trifluoroacetic acid as the mobile phase. The solute was detected with high sensitivity and specificity by a UV-VIS detector set at 423 nm.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 179-179 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Some L- and D-amino acids (Phe or Leu) were derivatized with a fluorogenic reagent, 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) and separated on a Pirkle-type column, Sumichiral OA 2500(S) [(S)-1-naphthylglycyl-3,5-dinitrophenylamide silica gel] with a mobile phase of 20 mM ammonium acetate in methanol. The fluorometric detection was made at 530 nm with excitation at 470 nm. No racemization of the enantiomers occurred during the derivatization reaction. The separation factors (α) for NBD-L-Phe and NBD-D-Phe, and NBD-L-Leu and NBD-D-Leu, were 1.27 and 1.17, respectively. The detection limits were in the range of ca. 30 fmol.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 189-195 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A reversed phase high performance liquid chromatographic technique is presented allowing purine catabolite determination in a whole blood extract without a prior purification step. The method was applied to determine the timing and the profile of myocardial nucleotide catabolite release during reperfusion of the transplanted human heart. Samples of arterial and coronary sinus blood collected at various times within 1 h after aortic declamping during heart or heart-lung transplantations were used for nucleotide catabolite determination. Massive release of inosine and hypoxanthine from the heart was demonstrated. Production of adenosine was also shown but there was no liberation of xanthine or uric acid. Nucleotide catabolite release was greatest in the first 5 min (coronary sinus-arterial difference = 15-20 μM), but was still significant after 30 min of reperfusion. The determination of inosine and hypoxanthine--major catabolites released--was found to be reproducible in coronary sinus blood (coefficient of variation 〈 10%). However, immediate protein precipitation afer blood sample collection was necessary, as rapid metabolism of both exogenous and endogenous adenosine and inosine was demonstrated.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic method with chemiluminescence detection for the determination of penicillin G and ampicillin is reported. The method is based on the enhancement of the luminol chemiluminescence with β-lactam antibiotics. The linear relationship was obtained between the peak height and the concentration of penicillin G or ampicillin up to 15 nmol per 20 μL injection. Detection limits were 1 nmol for penicillin G and 0.5 nmol for ampicillin with a signal-to-noise ratio of 2. Relative standard deviations for five replicate measurements of 4 nmol/injection each of penicillin G and ampicillin were 2.1 and 2.3%, respectively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 231-232 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 48-55 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: We have investigated the hydrophobic properties of human skin fibroblast proteoglycans and related material by affinity chromatography on Octyl-Sepharose CL-4B in 4 M guanidinium hydrochloride (GdnHCI). Proteoglycans and related material could be separated into non-, medium and highly hydrophobic forms by elution with gradients of Triton X-100 in 4 M Gdn HCI. The non-hydrophobic material included endogenously produced glycosaminoglycan chains and oligosaccharides as well as an HS-proteoglycan with a 35 kDa core. The 65-70 kDa core (glypican-related) proteoglycans appeared among the highly hydrophobic ones, but variable proportions were seen both in the medium and the non-hydrophobic material. Other membrane-bound proteoglycans, like fibroglycan (45 kDa core) and the HS-proteoglycans with 90 and 130 kDa cores, as well as the CS/DS-proteoglycan with a 90 kDa core, were all of high hydrophobicity. There were also indications of a highly hydrophobic CS/DS-proteoglycan with a 45 kDa core. The extracellular proteoglycans, PG-L, PG-S1 and PG-S2, and the HS-proteoglycans with 350 and 250 kDa cores were all of medium hydrophobicity. These proteoglycans emerged in distinct positions when the column was eluted with a gradient of 3-[(3-cholamidopropyl)dimethylammonio]propanesulphonate.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The reactivities between saccharides and primary amino compounds were studied by liquid chromatography on an amino-bonded column and by measurement of the reaction rates of aromatic amines with saccharides. The recoveries from the column and the reaction rates were correlated with their physicochemical properties calculated by the CACheTM program. The reactivities between amines and saccharides correlated well with their hydrogen bonding energies calculated by molecular mechanics.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 86-89 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A rapid, sensitive and selective method for the assay of glutathione in cultured cells has been developed using ion-pair reversed phase rapid high performance liquid chromatography. The use of a 4 μm particle, 5 cm long column (Superspher 100 RP 18 end-capped) allowed complete analysis of glutathione within 3 min. A postcolumn derivatization reaction with o-phthaladehyde and fluorometric detection made the assay fully selective with regard to other endogenous thiols and sensitive (the detection limit was 0.5 ng of glutathione injected). The linearity range was between 0.1 and 2.0 μg/mL with good repeatability (relative standard deviation less than 5% for the lowest concentration quantitated). Recoveries of GSH from cultured cell samples were above 98%. The rapid analysis enabled the processing of a large number of samples in a short time (up to 20 per hour). The method was applied to the measurement of the intracellular glutathione amount in V79 fibroblasts along cell growth in culture.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A stereoselective and sensitive method for the determination of the enantiomers of felodipine, a dihydropyridine calcium antagonist, has been developed and the pharmacokinetic profiles of the enantiomers comparatively studied after oral administration to dogs and humans. D6-Felodipine, the internal standard, was added to the plasma, extracted with a solvent and then optically resolved into S(-) and R(+) enantiomers on a high performance liquid chromatographic Chiralcel OJ column. Each enantiomer in the effluent was analysed by capillary column gas chromatography/positive ion electron impact mass spectrometry. After oral administration of the felodipine racemate, the Tmax and t1/2 values hardly differed between the two enantiomers in dogs and humans. The Cmax and AUC0-24h values of the S(-) enantiomer were slightly higher than those of the R(+) enantiomer in humans but the difference between the enantiomers was not significant. These results suggested that there is no large difference in the absorption, distribution and elimination of felodipine enantiomers after oral administration of the racemate in either dog or human.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The development of column packing materials was tried as a contribution to studies related to the further modification of 3-aminopropyl-modified silica gel. Consequently, we prepared two types of gel, 3-(1-naphthoylamino)- and 3-(1-anthroylamino)-propyl-modified silica gels (NAPS and AAPS). Since NAPS and AAPS, each having an aromatic ring, were expected to behave in a separation mode by a π-π or hydrophobic interaction, their application to the analyses of the compounds related to nucleic acids was carried out. Adenosine nucleotides were consequently separated by the gels in a single analysis by a single buffer elution with UV detection. NAPS could be also successfully used for the measurement of ATPase activity in fish meat (Sillago japonica). The mobile phase consistently used in the analysis was an aqueous phosphate buffer.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method has been developed for the determination of secondary amines by gas chromatography (GC). After removal of primary amines by the reaction with o-phthaldialdehyde, secondary amines were converted into their N-diethylthiophosphoryl derivatives and then measured by GC with flame photometric detection using a DB-1701 capillary column. The derivatives were sufficiently volatile and stable to give single symmetrical peaks. The detection limits of secondary amines were ca. 0.05-0.2 pmol per injection. N-Methylcyclohexylamine was used as an internal standard. The calibration curves for secondary amines in the range 1-20 nmol were linear and sufficiently reproducible for quantitative determination. This method was successfully applied to small urine samples without prior clean-up. Overall recoveries of secondary amines added to urine samples were 91-105%. By using this method, secondary amines in urine samples could be analysed without any influence from primary amines and other coexisting substances. The analytical results of secondary amine content in urine samples of normal subjects are presented.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A method has been developed for the quantitative analysis of clomipramine and its major metabolite desmethylclomipramine in plasma, using normal phase chromatography with UV detection at 254 nm. This rapid (6 min) and highly sensitive methodology (detection limits 0.5 ng/mL and 2 ng/mL for clomipramine and desmethylclomipramine, respectively; S/N = 3, 0.001 aufs) allows pharmacokinetic studies and drug monitoring of the two compounds. Using the described methodology we report an application which involved 10 depressed inpatients.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A simple, selective, reversed phase liquid chromatographic method using a column-switching technique has been developed for the simultaneous determination of a novel derivative of etoposide (NK611) and its O-demethyl metabolite in dog plasma. A good linear response was obtained for both drugs in the range 0.1-12.0 μg/mL. The mean recoveries were within 100±5%. The within- and between-day precisions were within 3.5% and 4.6%, respectively. This method was used in a pharmacokinetic study following intravenous and oral administration of NK611 to beagle dogs.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 94-98 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Two forms of liver metallothioneins (MTs) were purified from hedgehog exposed to zinc, using gel filtration on Sephacryl S-100 and DEAE Sepharose Fast Flow chromatography. The peptide chain weight of both MT-1 and MT-2 was found to be about 10,000, as determined by high performance liquid chromatography. This value was higher than that calculated from amino acid analysis. The amino acid composition of hedgehog liver MT-1 and MT-2 resembles that of liver to MTs from rabbit and other species. Their distinctive features include an extremely high cysteine content, about 33% of all the amino acid residues, and an absence of aromatic amino acids and histidine. In addition, a rapid method for the determination of MTs during animal tissue purification has been established. The samples were directly added in an ammoniacal solution of a Co(II) salt for recording linear sweep polarograms. By comparison with the commonly used metal determination method, our method is direct, rapid, credible and suitable for all the MTs or MT-like samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A reversed phase high performance liquid chromatographic method for the high sensitivity determination of individual bile acids in serum using a C18 column with a ternary solvent system combined with fluorometric techniques using immobilized enzymes is described. A computer-assisted diagnosis system using pattern recognition was developed to assist the clinical diagnosis of various liver and biliary diseases. A total consistency rate of 95% can be reached using this system.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 143-145 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Human pancreatic carboxypeptidase A, which was isolated from a pool of necrobiotic pancreae, crystallized spontaneously and appeared homogeneous in sodium dodecylsulphate polyacrylamide gel electrophoresis. Reversed phase high performance liquid chromatography of the dissolved crystals, however, revealed the presence of two distinct isoenzymes, which were shown by aminoterminal sequence analysis to be only 61% homologeous in their 31 amino terminal amino acids. On the other hand, amino terminal sequences of the isoenzymes were found to be 79% and 87% homologeous with CAP 1 and CPA 2 of the rat, respectively. Thus, the presence of two distinct pancreatic carboxypeptidase A isoenzymes could be clearly demonstrated for the first time in human tissue.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 200-203 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Formation of free radicals and lipoperoxidation occur at the onset of cellular damage. These effects are produced during normal metabolism and in pathological states. The peroxidation of polyunsaturated fatty acids, i.e. linoleic acid and linolenic acid, which are both cellular membrane compounds, induces ethane and pentane formation in pulmonary air exhalation. These two volatile hydrocarbons can be considered as potential lipoperoxidation markers. Methodological difficulties limit the use of these gases for assessment of free oxygen radical activity but we have developed and validated a non-invasive technique. A study was performed with ten healthy volunteers.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A gas chromatographic method for the determination of mexiletine in human plasma is described. Mexiletine was simultaneously extracted and derivatized with carbon disulphide for separation and quantitation on a glass column (1.5 m × 3 mm i.d.) packed with 1.5% OV-1 coated on 80-100 mesh Shimalite W (201D). The method required only 0.5 mL of plasma and could detect as little as 10 ng of mexiletine. It has been applied to the study of the pharmacokinetics of mexiletine in healthy volunteers.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Fluorescence and chemiluminescence analyses of amino acids and thiols derivatized with 2-fluoro-4,5-diphenyloxazole (DIFOX) and 2-chloro-4,5-bis(p-N,N-dimethylaminosulphonylphenyl)oxazole (SAOX-CI) were investigated. Thirteen diphenyloxazole (DIOX)-derivatized amino acids were separated within 38 min by a linear gradient elution from 100% A [0.05 M phosphate (pH 7.0):CH3CN (75:25)] to 100% B [0.05 M phosphate (pH 7.0):CH3CN (1:1)] over 30 min and an isocratic elution of 100% B for 30 min. The detection limits (S/N = 2) with fluorescence detection were in the range of 19-64 fmol. Thiols derivatized with SAOX-CI were separated by an isocratic elution using 0.1 M H3PO4:CH3CN (65:35) and detected fluorimetrically. The detection limits (S/N = 2) of reduced glutathione, N-acetylcysteine, 2-mercaptopropionylglycine, cysteine, homocysteine and captopril were 1.2, 1.5, 1.9, 5.7, 6.4 and 7.9 fmol, respectively. Peroxyoxalate chemiluminescence (CL) intensities of sulphonyl-5-N,N-dimethylaminonaphthalene (DNS), SAOX and DIOX derivatives were compared using three different oxalate esters (DFPO, TCPO and TDPO) by flow injection analysis. The relative chemiluminescence intensity (RCL) of SAOX-proline and DIOX-proline were 76-80% and 19-25% of DNS-proline (100%), respectively. Other SAOX and DIOX derivatives showed lower CL intensities ( 〈 12%). Extremely low CL intensities were obtained for the fluorescent tagging reagents (〈0.11%) and their hydrolysis products (〈0.80%). Secondary amino acids and peptides, derivatized with DIFOX in aqueous media at room temperature for 1 h, were detected using DFPO/H2O2. TCPO/H2O2 and TDPO/H2O2 after separation by high performance liquid chromatography. The detection limits (S/N = 2) of hydroxy-L-proline, L-proline, L-prolyl-glycyl-glycine and L-prolyl-L-leucine with the three oxalate esters were 10-17 fmol, 22-34 fmol, 50-61 fmol and 80-123 fmol, respectively.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. ii 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 229-230 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A sensitive and selective reversed phase high performance liquid chromatographic method was introduced for the determination of salmon calcitonin (sCT) in solutions containing bovine serum albumin or gelatin. The method was based on the sensitive fluorescence detection of sCT by postcolumn derivatization with o-phthal(di)aldehyde. The sample was loaded onto a reversed phase column, purified by column switching and separated with linear gradient elution using the ion pair technique. A linear relationship was obtained between the peak height and the amount injected in the concentration range 1-40 ng. The detection limit was 10 ng/mL (S/N = 3) at a sample injection volume of 100 μL.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 256-261 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Amyloglucosidase from Halobacterium sodomense was purified by a combination of hydrophobic interaction chromatography and immobilized metal ion affinity chromatography at analytical and preparative scale with 75% recovery. The enzyme was found to be a dimer of two different subunits with molecular weights of 72,000 and 82,000 D, respectively, combining in a 175,000 D native protein. The specific activity, KM, and amino acid composition of the enzyme was determined.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 273-274 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A sensitive (up to nanogram level) method for resolving a cannabinoid mixture in plasma is described. Cannabinoids were extracted with a C-18 Sep Pak cartridge and derivatized with dansylchloride. Then the derivatives were resolved on thin layer HPTLC silica plates which were developed and quantified by fluorescence densitometry at 340 nm.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The recent developments in enantioselective HPLC-separation techniques are impressive and are driven by industrial and academic interests; thus there is for instance a high demand for developing stereoselective assays for chiral drugs in biological fluids. The beta-blocking agents, which possess an amino- propanol- or -ethanol side chain with at least one chiral centre, represent one of the most intensively investigated groups of more than 40 drugs introduced world wide. Seven of the most popular beta-blockers were chosen as representatives: atenolol; betaxolol; carvedilol; metoprolol; pindolol; propranolol; and sotalol, these span the whole range of lipophilicity to hydrophilicity (polarity). Enantioselective HPLC bioassays for these β-blockers published so far, including techniques based on chiral derivatizing agents (CDAs), chiral stationary phases (CSPs) and chiral mobile phase additives (CMPAs) have been reviewed and documented in the light of general aspects together with pharmacokinetic and pharmacodynamic considerations.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. ii 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 227-228 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic (HPLC) method has been developed for the determination of levomepromazine in human breast milk and serum. The levomepromazine was extracted by a rapid and simple extraction method using a Sep-Pak C18 cartridge. The extracts were separated by HPLC on a C8 bonded reversed phase column and detected by UV absorbance at 254 nm. There was no interference with endogenous substance in human breast milk and serum. A linear relationship was obtained for the levomepromazine over the concentration range of 10-300 ng/mL. The recoveries of levomepromazine added to human breast milk and serum were 92.5-99.1% and 86.9-103.9%, respectively.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 233-233 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A sensitive HPLC method has been described for quantitation of two cholecystokinin (CCK) peptides in discrete rat brain regions. Separation and quantitation was performed by the reversed-phase HPLC combined with electrochemical detection. Analytical recoveries of the tetrapeptide (CCK-4) and octapeptide-sulphate (CCK-8s) were 96% and 94%, respectively. The between assay coefficient of variation (CV) was less than 3% for both peptides. The within-assay CV was 4% and 6% for CCK-4 and CCK-8s and the detection limit was 2 and 10 pmol/mL, respectively.For identification of structures, the peptides were fractionated by semi-preparative HPLC using a novel SMART system for micropurification. The fractions were analysed by fast atom bombardment mass spectrometry (FAB MS) which confirmed the presence of both CCK-4 and CCK-8s in the rat brain tissue.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 267-272 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Reliable measurement of the reduced and oxidized forms of ascorbic acid (AA) is challenging because they are highly reactive and unstable compounds. Detection of small amounts of AA and dehydroascorbic acid (DHAA) is essential for determining the biochemical function of the vitamin. While a variety of techniques exist for measurement of AA with detection limits in the millimolar range, a need exists for highly reliable assessment of picomolar levels of AA and DHAA in tissues. The present study presents a method for measuring AA and DHAA that combines high performance liquid chromatography with the advantages and increased detection limits and selectivity available with coulometric electrochemical detection. The difference between AA and „total AA“ in tissue samples gives an assessment of DHAA concentration. Verification of the reliability of assay is by the successful linear recovery of exogenously added AA and DHAA in tissue homogenate. Optimal conditions for reducing DHAA in tissue samples include a pH of 7.2, reaction time of 10 min, reaction temperature equal to room temperature, and a 10 mM concentration of the reducing agent, β-mercaptoethanol. AA and DHAA are measured in several mammalian tissues using the method presented.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 12-14 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The diuretic drug hydrochlorothiazide (HCT) is used mainly for treatment of mild to moderate hypertension and is usually administered with other drugs. An assay for the determination of HCT in human plasma and urine by high performance liquid chromatography (HPLC) has been developed. Samples were purified by solvent extraction and analysed by reversed phase HPLC with ultraviolet detection, using hydroflumethiazide as the internal standard; plasma was eluted using gradient elution and urine was analysed isocratically. The method is simple to perform, is sensitive (detection limit 0.01 μg/mL in plasma and 0.2 μg/mL for urine); it showed good reproducibility (3-8%). A great number of drugs did not interfere with the assay and the method was used for pharmacokinetic studies in healthy subjects, but samples from patients can also be analysed with high selectivity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Hydrophilic peptides generated from enzymic fragmentation of proteins are difficult to purify because they are either weakly bound or unretained by the reversed phase C18 columns favoured for liquid chromatographic separation of peptide mixtures. To overcome this difficulty, peptides that were not bound or only weakly bound by a C18 RP column were reacted with phenyl isothiocyanate (PITC), as used in the initial step in Edman sequencing. The hydrophobic phenylthiocarbamyl (PTC) peptide derivatives produced by the reaction were rechromatographed on the same column. Peptides generated by tryptic digestion of equine cytochrome C were used as a model system to test whether a complete set of peptide fragments could be purified by this method using just one column and solvent system. All the expected hydrophobic tryptic peptides bound to the RP column and were resolved by elution with acetonitrile, but no hydrophilic peptides were recovered as pure fractions. The column breakthrough fraction was reacted with PITC and rechromatographed on the same column, producing a profile consisting of 19 bound peaks. Further rechromatography of some of the fractions at different column temperatures enabled all six of the expected hydrophilic peptides to be purified and identified. The technique has also been applied to the sequence determination of coat protein from peanut stripe potyvirus protein, eight hydrophilic tryptic peptides being recovered and identified as PTC derivatives.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 20-24 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Propoxur (Baygon, 2-isopropoxyphenyl N-methylcarbamate) is a carbamate pesticide commonly used against house insects. When the insecticide was administered intramuscularly in rats it was converted to a new metabolite which was found to be present in the serum, liver, kidney and brain 6 h after the administration of the pesticide. The metabolite was purified by high performance liquid to chromatography and comparison of the infrared spectra of Propoxur and the metabolite showed that a deamination reaction was responsible for the formation of the metabolite from the parent pesticide. The pesticide also induced haematological changes such as an increased level of total bilubrin, amylase and glutamic-oxalacetic transaminase and decrease of cholinesterase activity, indicating damage of the liver and nervous system in rats.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A direct, isocratic and simple liquid chromatographic method is described for the enantiomeric separation of propafenone (PRO) and its major metabolite, 5-hydroxypropafenone, using a cellulose tris-3,5-dimethylphenyl carbamate (Chiralcel ODS) column. The sterochemical separation factor (α) obtained was 1.14 and the maximum stereochemical resolution factor (R) was 0.80 when using a mobile phase consisting of hexane: 2-propanol: diethylamine (90:10:0.4) at 23°C. The hydroxy metabolite could not be successfully separted into its corresponding enantiomers under these chromatographic conditions. The method has been used to determine and identify the enantiomers of PRO and its hydroxy metabolite in a serum sample.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Novel fluorogenic Edman reagents, 7-N,N-dimethylaminosulphonyl-4-(2,1,3-benzoxadiazolyl)isothiocyanate (DBD-NCS) and 7-aminosulphonyl-4-(2,1,3-benzoxadiazolyl)isothiocyanate (ABD-NCS) having no fluorescence themselves were synthesized. The derivatives of amino acids with DBD-NCS fluoresce at 505 nm with excitation at 385 nm. They were separated on a reversed-phase HPLC column and detected at the sub-picomol level. Ala-Phe derivatized with DBD-NCS was cleaved by acid to generate DBD-thiocarbamyl-Ala.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 162-165 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic (HPLC) procedure for measuring pyridoxal-5′-phosphate (PLP) and certain forms of B6 vitamers in plasma is presented here. This HPLC procedure consisted of a single graphitic carbon column with a fluorescence detector employing an isocratic eluent (15% acetonitrile:1% perchloric acid: 0.05% sodium bisulfite). The graphitic carbon column is useful in acidic eluent without deteriorization. The relatively low fluorescent intensity of PLP under acidic conditions is improved by its derivatization with bisulfite in the eluent during chromatographic separation. Using this procedure, the detection limit of PLP is 50 fmol, and an aliquot of 5-50 μL of human plasma is required giving satisfactorily precise results within 5 min. We applied this method to the determination of PLP and certain B6 vitamers in human plasma after oral supplementation of pyridoxine.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 126-128 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A rapid and simple high performance liquid chromatographic analytical method is described for the simultaneous determination of norfloxacin and furprofen in rat plasma. Following dichloromethane extraction, the solution was chromatographed in a Vydac anion exchange column using a mobile phase of 0.05 M phosphate buffer (pH=7.0):acetonitrile (80:20, v/v) at a flow-rate of 1.8 mL/min. The drugs were detected by UV absorption at 278 nm. The total chromatographic analysis time was 10 min. The response was linear, 0.1-5.0 μg/mL for norfloxacin and 0.1-3.0 μg/mL for furprofen, respectively. This method is useful for pharmacokinetic studies of these compounds and will facilitate detailed investigations into the interactions between quinolones and furprofen.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: We have studied the metabolism (absorption) of β-carotene and vitamin E by assigning eleven volunteers to receive daily two capsules of OENOBIOL, each containing 15 mg of β-carotene and 15 mg of vitamin E, over 60 days. The β-carotene, vitamin E and vitamin A plasma levels were then determined using new methods developed in our laboratory. After two months, the actively treated group's median β-carotene and vitamin E levels were significantly higher than those of a control group. However, no significant change between treated and control groups in the mean of vitamin A (retinol) plasma levels were observed. Treatment with β-carotene, a vitamin A precursor, does not significantly modify the vitamin A levels. This conclusion had already been observed and it is assumed that a plasma level of β-carotene equal or higher than 0.3 mg/L reflects a nutritional intake of provitamins sufficient to support homeostasis of retinol (Brubacher et al., 1982).
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 119-119 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 134-135 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic assay for the quantitation of acetazolamide in both tablet and injection form is described. Acetazolamide is extracted with 0.005 M NaOH solution containing 0.3 mg/mL sulphadiazine (internal standard).A commercially available μ-Bondapak C18 cartridge column was used for the separation together with a mobile phase made of acetonitrile, methanol and sodium acetate buffer mixture (10:2:88) (pH 4) at a flow-rate of 4 mL/min. Retention times of about 2.50 and 3.36 min were obtained for the drug and the internal standard, respectively.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 146-148 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A separation to the baseline isocratic technique has been developed for the evaluation of the purity of aprotinin by internal normalization. The column used was a 30 nm pore diameter butyl-bonded silica stationary phase. An exact relationship was found to give an adequate description of the retention of aprotinin using acetonitrile concentrations of 17-22% and NaCIO4 concentrations of 5-50 mmol. It can be used to optimize the mobile phase content for the particular user column and to compensate for possible variations in the retention time of aprotinin, analysed on different batches of butyl-bonded stationary phases.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 180-180 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A rotating flow mixing device having three directional inlets was developed for a high performance liquid chromatographic peroxyoxalate chemiluminescence detection system for the sensitive detection of fluorescent compounds separated with acidic mobile phases, such as those containing trifluoroacetic acid. The diameters of the three inlets were 0.3, 0.3 and 0.5 mm i.d., for an acidic column eluate, chemiluminogenic reagents (bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl] oxalate and hydrogen peroxide) and imidazole solution (for neutralization and as a catalyst), respectively. The three mixed solutions flowed out through an outlet (0.5 mm i.d.) at the centre of the top of the vessel. The reaction conditions to give the appropriate signal-to-noise ratio (S/N) were investigated using dipyridamole (an antiplatelet aggregation drug) as a typical fluorescent compound. The system was applied to the detection of dipyridamole and dansylated amino acids with a mobile phase containing trifluoroacetic acid. The detection limits for dipyridamole and each dansylated amino acid were 10 amol and sub-fmol (S/N=2), respectively.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 311-314 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: An isocratic reversed-phase high performance liquid chromatographic method for the determination of tamoxifen and its metabolites in plasma and tissues is described. Plasma or tissue homogenate was extracted with methanol/dimethyl sulphoxide (4:1 v/v). The supernatant after centrifugation was separated on a BDS-Hypersil column with methanol/0.5 M ammonium acetate (75:25 v/v) as the mobile phase. The recoveries of tamoxifen added to plasma and liver tissue homogenate by the extraction procedure were 102± 1.6 and 98±2.4% (mean±SD, n = 6), respectively. The solutes were detected at 280 nm with a detection limit of 0.25 μg/mL for tamoxifen.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 317-320 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A method for the preparation of a new packing material for high performance liquid chromatography by bonding an anti-interferon monoclonal antibody to the surface of silica gel is described. The high coupling efficiency and activity of the interferon-αA-monoclonal antibody (IFN-αA-McAb) column were obtained by activated diol-silica gel with an activating agent. After purification with this packing material, the specific activity of recombinant human interferon-αA rose by up to 1.03 × 107IU/mg protein and the purification efficiency was increased by approximately 100 times.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic (HPLC) method with fluorescence detection after on-line reduction for the determination of 1-nitropyrene (NP), 1-nitrosopyrene (NSP), 1-aminopyrene (AP) and N-acetylaminopyrene (AAP) has been developed. The reduction efficiency of NP and NSP on a zinc column was found to be higher than that of an electrochemical reducer. Using a HPLC equipped with a zinc column (4.0 mm i.d. × 10 mm) and an imidazole/HCIO4 (pH 6.8):acetonitrile mobile phase, detection limits (S/N = 3) of 20-30 fmol for NP, NSP and AP and 350 fmol for AAP were obtained. NP, NSP and AP were determined in the incubation mixture of NP and Salmonella typhimurium, YG1021, by this method. Time course studies showed that a large ratio of NP was metabolized in the pre-incubation step of the Ames test.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 301-305 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The metabolic fate of fenitrothion, O,O-dimethyl-O-(3-methyl-4-nitro phenyl) phosphorothioate, was investigated in rat tissues during the first 24 hours following the intramusculer administration of the pesticide in the animal. High performance liquid chromatography (HPLC) of the pesticide and its metabolites formed in liver, kidney and brain showed the time-dependent sequential conversion of the pesticide into three major metabolites. These metabolites were separated and purified to homogeneity by HPLC and characterized by IR spectroscopy as O,O-dimethyl-O-)3-methyl-4-aminophenyl) phosphorothioate (metabolite I), O,O-dimethyl phosphorothioate (metabolite II), and O,O-dimethylphosphate (metabolite III). These results indicated reduction of the nitro group in fenitrothion aas the first step, followed by the hydrolytic cleavage of the P-O-aryl bond in metabolite I and the oxidative desulphurylation of metabolite II. Fenitrothion was found to induce ultrastructural changes in liver cells especially after 12 h exposure nuclear membrane was completely distorted, nuclear intactness was totally lost and smooth endoplasmic reticulum and Golgi apparatus were abnormally enlarged. In 24 h, however, the regeneration of the nuclear material was observed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method for the determination of free and total proline (Pro) and 4-hydroxyproline (Hyp) by gas chromatography (GC) was developed. For free Pro and Hyp analysis, plasma and tissue homogenate were extracted with methanol. For total Pro and Hyp analysis, these samples were hydrolysed in 6 M HCI. After removal of primary amino compounds by the reaction with o-phthaldialdehyde, Pro and Hyp in methanol extract and acid hydrolysate were converted into their N-dimethylthiophosphoryl methyl ester derivatives and then determined by GC with flame photometric detection using a DB-5 capillary column. This method was successfully applied to small samples without prior clean-up, and Pro and Hyp in these samples could be analysed without any influence from coexisting substances. Overall recoveries of Pro and Hyp added to plasma and tissue samples were 92-106%. The analytical results of free and total Pro and Hyp in human plasma and mouse tissue samples are presented.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 315-316 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A simple and sensitive (up to nanogram level) method to determine norepinephrine, serotonine and dopamine in rat brain is described. The amines are acetyled and the derivatives are resolved by thin layer chromatography (TLC) on silica high performance thin layer chromatography (HPLC) plates. Quantification is achieved by fluorescence densitometry at 415 nm excitation wavelength.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 75-76 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 243-253 
    ISSN: 0886-9383
    Keywords: Orthogonal expansion ; Mapping ; Modelling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this paper we discuss the orthogonal expansion of data matrices and its application to mapping and modelling. Two new methods, modified optimal discriminant plane (MODP) for mapping and order Gram-Schmidt orthogonalization (OGSO) for modelling, are proposed and examples are given.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 381-392 
    ISSN: 0886-9383
    Keywords: Factor analysis ; Kolmogorov-Smirnov test ; Non-parametric tests in factor analysis ; Non-parametric test for principal components ; Principal component analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Each eigenvector of the dispersion matrix [X]T [X] was shown to be a partial predictor of the original data matrix [X], the sum of the predictions from the individual principal components being equal to the expectance of [X]. By comparing the distributions of the members of two neighbouring predicted matrices, [X̃]1…i and [X̃]1…i+1 (i.e. the sums of the first i and i + 1 individual predictions respectively), it was shown that they should be indistinguishable provided that i is equal to or greater than the effective rank of [X], and significantly different otherwise. This was confirmed by analysing the visible absorption spectra of methyl orange and methyl red solutions as well as the Raman spectra of Na2SO4 and MgSO4 solutions. On the grounds of these findings, a non-parametric goodness-of-fit test for assessing the effective rank of [X] was proposed which proved to be comparatively conservative and more robust than most currently used tests.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 369-379 
    ISSN: 0886-9383
    Keywords: Simulated annealing ; Constrained background bilinearization ; Calibration ; Two-way bilinear data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Generalized simulated annealing (GSA) is an optimization technique for locating the global optimum. In this paper GSA was used as the optimization procedure in the constrained background bilinearization (CBBL) of two-way bilinear data in order to reduce the possibility of sinking into local optima. The behaviour of the algorithm and its comparison with the modified Powell algorithm were studied by simulations and real fluorescence excitation-emission data for organic dye mixtures.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 439-445 
    ISSN: 0886-9383
    Keywords: Calibration ; Rank annihilation ; Residual bilinearization ; Three-way ; Trilinear ; Net analyte rank ; Second-order ; Generalized rank annihilation method (GRAM) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Through theoretical analysis and computer simulation, this short communication comments on the residual bilinearization (RBL) method and compares it with non-bilinear rank annihilation (NBRA) for the treatment of second-order calibration with non-bilinear data. It is found that these two methods are mathematically equivalent but have different noise propagation properties. The second-order advantage, namely quantitation in the presence of unknown interferences, can be carried over to non-bilinear data only if there exists a net analyte rank (NAR) for the analyte of interest.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 495-526 
    ISSN: 0886-9383
    Keywords: Standard errors ; Eigenvalues ; PCA ; MLR ; GRAM ; Rank estimation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New expressions are derived for the standard errors in the eigenvalues of a cross-product matrix by the method of error propagation. Cross-product matrices frequently arise in multivariate data analysis, especially in principal component analysis (PCA). The derived standard errors account for the variability in the data as a result of measurement noise and are therefore essentially different from the standard errors developed in multivariate statistics. Those standard errors were derived in order to account for the finite number of observations on a fixed number of variables, the so-called sampling error. They can be used for making inferences about the population eigenvalues. Making inferences about the population eigenvalues is often not the purposes of PCA in physical sciences. This is particularly true if the measurements are performed on an analytical instrument that produces two-dimensional arrays for one chemical sample: the rows and columns of such a data matrix cannot be identified with observations on variables at all. However, PCA can still be used as a general data reduction technique, but now the effect of measurement noise on the standard errors in the eigenvalues has to be considered. The consequences for significance testing of the eigenvalues as well as the usefulness for error estimates for scores and loadings of PCA, multiple linear regression (MLR) and the generalized rank annihilation method (GRAM) are discussed. The adequacy of the derived expressions is tested by Monte Carlo simulations.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 559-566 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 61-73 
    ISSN: 0886-9383
    Keywords: Compression ; Multivariate analysis ; B-splines ; Maximum entropy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: For efficient handling of very large data arrays, pretreatment by compression is mandatory. In the present paper B-spline methods are described as good candidates for such data array compression. The mathematical relation between the maximum entropy method for compression of data tables and the B-spline of zeroth degree is described together with the generalization of B-spline compression to nth-order data array tables in matrix and tensor algebra.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...