Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Double Chambered Pneumatically Driven Blood Pump  (1)
  • Fabrication  (1)
  • 1
    ISSN: 1435-2451
    Keywords: Total Artificial Heart Replacement ; Double Chambered Pneumatically Driven Blood Pump ; Haemodynamic ; Changes in Longtime Survivors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Über hämodynamische Beobachtungen bei 20 Kälbern, die den Totalersatz des Herzens mit einer inkorporierten zweikammerigen Blutpumpe länger als 10 Std überlebten, wird an Hand folgender Parameter berichtet: - Drucke in beiden Vorhöfen und in der unteren Hohlvene, - Drucke in Aorta und Pulmonalis, - Drucke in beiden künstlichen Ventrikeln, - Drucke in dem pneumatischen Antriebssystem, - Perfusionsvolumina und AVDO2. Es wird gezeigt, daß die künstlichen Blutpumpen in der Lage sind, ein der Vitalität der Tiere genügendes Perfusionsvolumen zu fördern. Die Steuerungsmöglichkeiten einmal über Änderungen der Antriebsgrößen, zum anderen über den sog. Starling-Mechanismus des künstlichen Herzens, erweisen sich als den Anforderungen genügend. Nach längeren Überlebenszeiten findet sich ein Anstieg des rechten Vorhofdruckes, eine Zunahme der Perfusionsvolumina und somit bei annähernd konstanten arteriellen Drucken ein Absinken des peripheren Gesamtwiderstandes. Zur Deutung dieser Beobachtungen werden u. a. diskutiert Störungen der neurohumoralen Kreislaufregulation durch die Aktion der künstlichen Blutpumpen oder etwa der mögliche Einfluß eines septischen Krankheitsbildes. Prof. Dr. E. S. Bücherl
    Notes: Summary The paper reports on haemodynamic observations in 20 calves surviving total heart replacement by an incorporated double chamber blood pump for more than 10 h. The following parameters are registered: - pressures in both atria and vena cava inferior, - pressures in aorta and pulmonary artery, - pressures in both artificial ventricles, - pressures in the pneumatic driving system, - perfusion volumes and AVDO2. It is demonstrated that the artificial blood pumps are able to obtain a perfusion volume sufficient for the animal's vitality. A sufficient regulation can be achieved by varying the driving system and by the so called Starling-mechanism of the artificial heart. In the long time surviving animals an increase of the right atrium pressure, and of the perfusion volumes is found while total peripheral resistance decreases. To explain these observations, disturbances of the neurohumoral circulatory control by the action of the artificial pumps or the development of sepsis are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 335 (1974), S. 13-40 
    ISSN: 1435-2451
    Keywords: Bloodpump ; Artificial Ventricle ; Fabrication ; Material ; Valves
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Nach einem kurzen Überblick über die Entwicklung der Blutpumpen in den letzten 15 Jahren werden die in der Berliner Arbeitsgruppe angewendeten Entwicklungsmethoden beschrieben. Sie betreffen die Schaffung einer für die Implantation günstigen Ventrikelform, die Strömung in der Blutpumpe und durch die Ventile, die Herstellung der Ventrikel und schließlich ihre Testung auf dem Prüfstand. In einem weiteren Abschnitt werden gelöste Probleme und neue Entwicklungsziele behandelt.
    Notes: Summary After a short outline of the development of the artificial heart in the last 15 years the work of the Berlin-group is described. The methods used here concern the development of a ventricular shape suitable for implantation, the investigation of the bloodflow within the ventricle and through the valves, the fabrication of the blood pumps and finally their testing in a mock-circulation. In a further chapter the problems already solved are described and an outline of future goals is given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...