Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Melanoma ; Hurthle cell tumor ; Oncocytoma ; Thyroid adenoma ; PET
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. A Hurthle cell tumor (oncocytoma) of the thyroid presented as a hypermetabolic focus in a fluorodeoxyglucose positron emission tomography (FDG PET) study which was performed as staging procedure in a patient with malignant melanoma. This finding led to the initial diagnosis of a metastasis. In contrast, multiple liver metastases, seen on MRI and sonography, did not show any increased FDG uptake. Cytology results of one liver mass confirmed a melanoma metastasis, and of the neck mass, a Hurthle cell tumor. The Hurthle cell tumor was, based on clinical evidence, thought to be benign. This is the first description of a FDG PET-positive benign Hurthle cell tumor, with FDG PET-negative liver metastases of a malignant melanoma, in the same patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Key words: Ovarian cancer ; Lesion characterization ; Recurrence ; PET ; CT ; MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to compare prospectively the accuracy of whole-body positron emission tomography (PET), CT and MRI in diagnosing primary and recurrent ovarian cancer. Nineteen patients (age range 23–76 years) were recruited with suspicious ovarian lesions at presentation (n = 8) or follow-up for recurrence (n = 11). All patients were scheduled for laparotomy and histological confirmation. Whole-body PET with FDG, contrast-enhanced spiral CT of the abdomen, including the pelvis, and MRI of the entire abdomen were performed. Each imaging study was evaluated separately. Imaging findings were correlated with histopathological diagnosis. The sensitivity, specificity and accuracy for lesion characterization in patients with suspicious ovarian lesions (n = 7) were, respectively: 100, 67 and 86 % for PET; 100, 67 and 86 % for CT; and 100, 100 and 100 % for MRI. For the diagnosis of recurrent disease (n = 10), PET had a sensitivity of 100 %, specificity of 50 % and accuracy of 90 %. The PET technique was the only technique which correctly identified a single transverse colon metastasis. Results for CT were 40, 50 and 43 %, and for MRI 86, 100 and 89 %, respectively. No statistically significant difference was seen. Neither FDG PET nor CT nor MRI can replace surgery in the detection of microscopic peritoneal disease. No statistically significant difference was observed for the investigated imaging modalities with regard to lesion characterization or detection of recurrent disease; thus, the methods are permissible alternatives. The PET technique, however, has the drawback of less accurate spatial assignment of small lesions compared with CT and MRI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1084
    Keywords: Key words: Spine ; Intervertebral disks ; Lasers ; MR imaging guidance ; MR imaging temperature monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of this study was to perform percutaneous laser disc decompression (PLDD) under MR guidance in an open configuration 0.5-T MR system. Following failed conservative treatment for 6 months, eight patients with contained disc herniations were enrolled in the study. Following MR guided introduction of the laser fiber into the targeted disc space, the laser-induced temperature distribution was visualized using a color-coded subtraction technique based on a T1-weighted GRE sequence. In seven patients PLDD could be performed. In all cases laser effects were depicted by MR. In this regard the color-coded technique was found to be superior to conventional magnitude images. Whereas no apparent decrease in the extent of herniation was discovered immediately following PLDD, T2-weighted FSE images showed signal intensity alterations in two of the seven patients. Clinical evaluation, obtained 3–4 months after PLDD, revealed a fair (n = 2) or good (n = 4) response to the treatment. One patient showed no change in symptoms. MR guidance and monitoring of PLDD is feasible within an open 0.5-T system and seems to render PLDD more safe and controllable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 5 (1995), S. 181-184 
    ISSN: 1432-1084
    Keywords: Bone metastasis ; Follicular cell carcinoma ; Magnetic resonance imaging (MRI) ; Radionuclide imaging (RI)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We present a patient with follicular thyroid carcinoma and multiple bone metastases who was referred for diagnosis and therapy. Radionuclide imaging (RI) and MRI were performed before and after therapy with radioiodine. On RI scan the locations of metastases were shown by radioiodine uptake. MRI of a femoral metastasis showed low signal intensity in T1-weighted sequences and some signal increase on T2-weighted sequences, almost identical to the signal behaviour of the normal thyroid gland. Hence, the signal intensity behaviour on MRI may yield some information on the differentiation of tumour metastases in thyroid carcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1084
    Keywords: Key words: Thyroid ; Biopsy ; Interventional MR ; MR guidance ; Stereotaxis ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. Representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultrasound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 6 (1996), S. 297-311 
    ISSN: 1432-1084
    Keywords: Magnetic resonance imaging ; Ultrafast magnetic resonance ; Echo-planar imaging ; Heart imaging ; Perfusion study ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Conventional magnetic resonance imaging (MRI) has been shown to provide excellent morphological images of the body organs, particularly structures undergoing little physiologic motion. Nevertheless, the clinical usefulness of MRI has been hampered by long acquisition times, high cost of scanning because of limited patient throughput, and image artifacts due to patient motion. With recent technical developments, several ultrafast scanning techniques capable of acquiring images in a breath-hold now find their introduction into clinical use. The system improvements are potentially useful for a vast range of applications hitherto not accessible to MR imaging. Among these are functional brain imaging, realtime imaging of cardiac motion and perfusion, fast abdominal imaging, improved MR angiography, and potentially real-time monitoring of interventional procedures. Whereas some ultrafast techniques can be performed on conventional scanners, echo-planar imaging, the fastest currently available data acquisition strategy, requires specially designed hardware. This article provides on overview of the technical advances in the ultrafast MRI and discusses potential applications and the possible future impact on body scanning.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 5 (1995), S. 181-184 
    ISSN: 1432-1084
    Keywords: Bone metastasis ; Follicular cell carcinoma ; Magnetic resonance imaging (MRI) ; Radionuclide imaging (RI)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We present a patient with follicular thyroid carcinoma and multiple bone metastases who was referred for diagnosis and therapy. Radionuclide imaging (RI) and MRI were performed before and after therapy with radioiodine. On RI scan the locations of metastases were shown by radioiodine uptake. MRI of a femoral metastasis showed low signal intensity in T1-weighted sequences and some signal increase on T2-weighted sequences, almost identical to the signal behaviour of the normal thyroid gland. Hence, the signal intensity behaviour on MRI may yield some information on the differentiation of tumour metastases in thyroid carcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1084
    Keywords: Key words:18FDG-PET ; Osteomyelitis ; Antigranulocyte antibody scintigraphy ; MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of this report is to discuss FDG-PET as a potentially new imaging tool in the diagnosis of infections of osteosynthetic material. We present a patient with a poly-trauma who developed a chronic osteomyelitis and ostitis after repeated osteosynthesis in a fibular transplant to the left femur. Work up included MRI, antigranulocyte antibody scintigraphy and positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG). Infection of the fibular transplant was demonstrated clearly by PET but not by the other methods. Positron emission tomography may become an important indication in the diagnosis and follow-up of bone infection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1460-9568
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Oxidative metabolism and cerebral blood flow (CBF) are two of the most important measures in neuroimaging. However, results from concurrent imaging of the two with high spatial and temporal resolution have never been published. We used flavoprotein autofluorescence (AF) and laser speckle imaging (LSI) in the anaesthetized rat to map oxidative metabolism and CBF in response to single vibrissa stimulation. Autofluorescence responses reflecting oxidative metabolism demonstrated a fast increase with a delay of 0.1 s. The sign-reversed speckle contrast reflecting CBF started to rise with a delay of 0.6 s and reached its maximum 1.4 s after the stimulation offset. The fractional signal changes were 2.0% in AF and 9.7% in LSI. Pixelwise modelling revealed that CBF maps spread over an area up to 2.5-times larger than metabolic maps. The results provide evidence that the increase in cerebral oxidative metabolism in response to sensory stimulation is considerably faster and more localized than the CBF response. This suggests that future developments in functional imaging concentrating on the metabolic response promise an increased spatial resolution.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-1084
    Keywords: Kidney ESWL ; Kidney function ; Kidney MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Contrast-enhanced gradient-echo MRI was used to evaluate morphological and functional alternations in the kidneys after extracorporeal shock wave lithotripsy (ESWL). Dynamic MRI with a temporal resolution of 10 s per image was performed by repeated imaging in the coronal plane after administration of gadolinium-DTPA (0.1 mmol/kg) before and after ESWL for renal calculi in 25 patients. Before ESWL 22 patients had normally functioning kidneys, characterised by a marked decrease in signal intensity in the renal medulla 30–40 s after the onset of cortical perfusion. After ESWL 8 patients had functional abnormalities: in 2 cases the medullary signal decrease was disturbed throughout the whole organ, while 6 kidneys demonstrated regional loss of concentrating ability in the medulla. Morphological alterations (oedema with blurred contours and loss of corticomedullary differentiation; parenchymal haemorrhage and haemorrhage in a cortical cyst; subcapsular, perirenal and pararenal haematoma) were detected in 9 cases. Haemorrhage was encountered more often after administration of more than 2500 shock waves; however, no such correlation was seen in the kidneys with functional disturbances following ESWL therapy. MRI proved to be a sensitive method for the assessment of morphological and functional alterations after ESWL, but longer follow-up studies are required to identify the clinical impact of these early changes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...