Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 1222-1224 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Epitaxial aluminum Schottky barrier diodes on molecular beam epitaxially grown p-GaAs with a free carrier density of 2×1016 cm−3 were irradiated with alpha particles at room temperature using an americium-241 (Am-241) radio nuclide. For the first time, the radiation induced hole defects are characterized using conventional deep level transient spectroscopy (DLTS). The introduction rates and DLTS "signatures'' of three prominent radiation induced defects Hα1, Hα4, and Hα5, situated 0.08, 0.20, and 0.30 eV above the valence band, respectively, are calculated and compared to those of similar defects introduced during electron irradiation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 114-130 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In standard Mott electron polarimetry using thin gold film targets, extrapolation procedures must be used to reduce the experimentally measured asymmetries A to the values they would have for scattering from single atoms. These extrapolations involve the dependence of A on either the gold film thickness t or the maximum detected electron energy loss in the target ΔE. Using a concentric cylindrical-electrode Mott polarimeter, we have studied and compared these two types of extrapolations over the electron energy range 20–100 keV. The potential systematic errors which can result from such procedures are analyzed in detail, particularly with regard to the use of various fitting functions in thickness extrapolations, and the failure of perfect energy-loss discrimination to yield accurate polarizations when thick foils are used. A critical discussion of previous work on this subject is presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 2101-2102 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: This note describes the design, construction, and test results of a modified sample holder used during low-temperature deep-level transient spectroscopy, current-voltage and capacitance-voltage measurements. This improved sample holder allows temperature scan rates of up to 6 K/min with a temperature shift of less than 1 K. High electrical isolation makes this sample holder also suitable for low-temperature current-voltage and capacitance-voltage measurements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Experiments to explore the long-time evolution of noninductive, high βp plasmas in the DIII-D tokamak [Plasma Physics and Controlled Nuclear Fusion Research, 1986 (International Atomic Energy Agency, Vienna, 1987), Vol. 1, p. 159], have identified a new, quiescent, high performance regime. The experiments were carried out at low current (400–800 kA) with medium power neutral beam injection (3–10 MW). This regime is characterized by high q0 ((approximately-greater-than)2) and moderate li(∼1.3). It is reached by slow relaxation of the current profile, on the resistive time scale. As the profiles relax, q0 rises and li falls. When q0 goes above 2 (approximately), magnetohydrodynamic (MHD) activity disappears, and the stored energy rises. Most dramatic is the strong peaking of the central density, which increases by as much as a factor of 2. The improved central confinement appears similar to the PEP/reversed central shear/second stable core modes seen in tokamak experiments, but in this case without external intervention or transient excitation. At high current, a similar, but slower relaxation is seen. Also notable in connection with these discharges is the behavior of the edge and scrape-off layer (SOL). The edge localized modes (ELM's) as seen previously, are small and very rapid (to 1 kHz). The SOL exhibits high density (≥1×1019 m−3), which shows little or no falloff with radius. Also the power deposition at the divertor surface is very broad, up to four times the width usually seen. This regime is of particular interest for the development of steady-state tokamak operating scenarios, for the Tokamak Physics Experiment (TPX), and following reactors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 95 (1991), S. 1144-1150 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: A simple model for van der Waals potentials presented earlier [J. Chem. Phys. 80, 3726 (1984)] has been extended to describe chemical bonds by including the exchange-dispersion term of Herring and Flicker. For H2, the 1Σ ground state potential is predicted in excellent agreement with the accurately known ab initio potential, the well depth being reproduced to within 0.6%. New two configuration self-consistent-field (SCF) calculations for the 1Σ and the 3Σ states of Li2 have made it possible to test the model for this system as well. Here the discrepancy is only 3% in the well depth for the 1Σ Li2 potential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3277-3279 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the MTX experiment, we use a network of computers for plasma diagnostic data acquisition and analysis. This multivendor network employs VMS, UNIX, and BASIC based computers connected in a local area Ethernet network. Some of the data is acquired directly into a VAX/VMS computer cluster over a fiber-optic serial CAMAC highway. Several HP-Unix workstations and HP-BASIC instrument control computers acquire and analyze data for the more data intensive or specialized diagnostics. The VAX/VMS system is used for global analysis of the data and serves as the central data archiving and retrieval manager. Shot synchronization and control of data flow are implemented by task-to-task message passing using our interprocess communication system. The system has been in operation during our initial MTX tokamak and FEL experiments; it has operated reliably with data rates typically in the range of 5 Mbytes/shot without limiting the experimental shot rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the time scale of a single FEL pulse.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 650 (1992), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Ecology, Evolution, and Systematics 23 (1992), S. 39-61 
    ISSN: 0066-4162
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1365-246X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences
    Notes: Within the DEKORP project (DEKORP: Deutsches Kontinentales Reflexionsseismisches Programm) a joint deep seismic reflection venture with the BELCORP (Belgian Continental Reflection Seismic Programme) group of the Belgian Geological Survey was carried out in 1987 across the Rhenish Massif, a part of the mid-European Variscides. This orogenic belt developed in the Upper Devonian/Carboniferous. Mostly Devonian rocks crop out at the surface. The Rhenish Massif is bordered by two sedimentary troughs: the sub-Variscan Foredeep in the north and the Permo-Carboniferous Saar-Nahe Basin in the south. In the east-west direction it is subdivided by the axial depression of the Eifel Nord-Süd Zone.The aim of the survey which totals almost 220 km of seismic profiling, was to investigate the crustal structure of the western part of the Rhenish Massif and to compare it with the line DEKORP 2-N which crosses the eastern portion of the massif. The results indicate the presence of NW-vergent tectonics of various styles that can often be traced down to deep parts of the crust. Horizontal Variscan compression plays a dominant role in the northern part while post-Variscan extension seems to dominate in the Saar-Nahe Basin, although even there traces of Variscan compression seem to be preserved in the middle crust. Common characteristics of the pre-Palaeozoic basement, differences between the western and eastern parts of the Rhenish Massif, and the deep extension of the Aachen Thrust (Faille du Midi) have been clearly observed. This prominent thrust in the north with its characteristic ramp and flat structure has been followed over 100 km length down
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...