Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 59 (1981), S. 1349-1351 
    ISSN: 1432-1440
    Keywords: Antithrombin III ; Plasma elimination Half-life ; Consumption coagulopathy ; Antithrombin III ; Plasma-Eliminations-Halbwertszeit ; Verbrauchskoagulopathie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Im Verlauf einer schweren Gerinnungsstörung bei einem Säugling mit Sepsis und Schock wurden vor und während der Substitutionsbehandlung mit humanem Antithrombin wiederholt die Antithrombin-III Spiegel gemessen. Diese Daten wurden mit Hilfe einer Biexponentialfunktion mathematisch ausgewertet. Die Plasma-Eliminations-Halbwertszeit des Antithrombins betrug 7,5 bzw. 10,5 Stunden. Verglichen mit bekannten Plasma-Halbwertszeiten von radioaktiv markiertem Antithrombin III bei Erwachsenen war die Elimination um den Faktor 5–10 beschleunigt. Die deutlich erniedrigten Antithrombin III Spiegel in diesem Fall konnten also mindestens teilweise auf einen beschleunigten Umsatz des Antithrombins zurückgeführt werden. Die Bestimmung der Plasma-Eliminations-Halbwertszeit von Antithrombin III ist hilfreich bei der Abgenzung einer verminderten Produktion von einem gesteigerten Umsatz im Verlauf einer Koagulopathie. Die Diagnose einer disseminierten intravasalen Gerinnung kann so etwas sicherer gestellt werden. Die Vorteile der Antithrombin- Substitutionstherapie werden bei diesem Vorgehen genützt, die Nachteile radioaktiv markierter Proteine vermieden.
    Notes: Summary During the course of severe coagulopathy in an infant suffering from septicaemia and shock, antithrombin III levels were determined repeatedly before and during substitution therapy with human antithrombin. By mathematical analysis of these data, using a biexponential function, the plasma elimination half-life of the antithrombin III was estimated to be 7.5–10.5 h. Compared with known plasma half-lives of radioactively labelled antithrombin III in adults the increase was five-to ten-fold. This indicates that the significantly decreased levels of antithrombin III in this case of coagulopathy were at least partly due to an accelerated consumption of antithrombin III. The estimation of the plasma elimination half-life of antithrombin III helps to differentiate decreased production from increased consumption in cases of severe coagulopathy. Thus, a more precise diagnosis of disseminated intravascular coagulation can be made whilst taking advantage of substitution therapy and avoiding the hazards of radioactive tracer proteins.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 61 (1983), S. 165-167 
    ISSN: 1432-1440
    Keywords: Platelet-associated IgG ; Micro-enzyme-linked immunoassay
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary An enzyme linked immunoassay was developed using the microtiter system to measure platelet-associated IgG (PAIgG). One single determination needs 2×106 platelets usually obtained from 3 ml blood anticoagulated with EDTA. Platelets are incubated with peroxidase-conjugated anti-human IgG. Its unbound fraction is adsorbed to an IgG coated microtiter plate, quantitated by a colour reaction and found to be inversely related to the amount of PAIgG. Healthy donors (n=40, aged 1 day to 35 years) possessed 3.6±2.0 (mean±S.D.) fg IgG/platelet. Increased levels of PAIgG were found in patients with acute (n=16) and chronic (n=5) idiopathic thrombocytopenic purpura. Postrecovery platelets had normal values of PAIgG. Widely varying levels of PAIgG were found in patients with freshly diagnosed acute lymphocytic leukemia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Communications in mathematical physics 87 (1982), S. 65-80 
    ISSN: 1432-0916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Notes: Abstract A new class of space-times is introduced which, in a neighbourhood of spatial infinity, allows an expansion in negative powers of a radial coordinate. Einstein's vacuum equations give rise to a hierarchy of linear equations for the coefficients in this expansion. It is demonstrated that this hierarchy can be completely solved provided the initial data satisfy certain constraints.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 141 (1984), S. 225-227 
    ISSN: 1432-1076
    Keywords: Antithrombin III (heparin cofactor activity) ; Plasma elimination half-life ; Newborn infants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Antithrombin III (AT III) levels are markedly increased in newborn infants following exchange transfusion with adult blood, and subsequently return to pre-exchange values. This transient rise in AT III (heparin cofactor activity), was used to estimate its plasma elimination half-life. AT III activities were measured serially, before and after double-volume exchange transfusions with heparinised blood in newborn infants requiring therapy for severe hyperbilirubinaemia. The plasma elimination half-life of AT III activity was calculated to be 3.9±1.4 h ( $$\overline X = 2.05$$ ±SEM). Compared with published data on the kinetics of AT III infusions in adults, the neonate has a considerably accelerated turnover. This finding has important implications for the design of future therapeutic trials of AT III concentrates and provides further evidence that plasma proteins, including components of the coagulation system, appear to have different kinetics in the neonatal period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 145 (1986), S. 500-503 
    ISSN: 1432-1076
    Keywords: Antithrombin III ; Albumin ; Shock
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Low antithrombin III (AT III) levels in shock are usually ascribed to disseminated intravascular coagulation (DIC). However, decreased activities of clotting factors and their inhibitors could reflect a generalised fall in plasma proteins rather than DIC. AT III and albumin were compared in 48 asphyxiated and non-asphyxiated newborn rabbits (pH6.70–7.30). Both AT III and albumin were markedly decreased in the sickest animals and there was a direct linear relationship between the two proteins (P〈0.001). Similar results were obtained in ten newborn infants suffering from shock and haemorrhagic diathesis. In all cases AT III and albumin were decreased below the normal range and significantly correlated (P〈0.01). Our findings suggest that AT III is not a useful diagnostic marker of DIC. Further, a similar fall of clottable and non-clottable proteins in shock questions the general assumption that the ensuing coagulopathy is due to intravascular coagulation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    Berlin : Periodicals Archive Online (PAO)
    Deutsche Zeitschrift für Philosophie. 37:3 (1989) 257 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 91 (1989), S. 6477-6493 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: In order to address the problem of three-body interactions in gas–surface scattering, we considered the collision of a He atom with the (0001) surface of graphite coated by a monolayer of Xe. To eliminate the uncertainties connected with errors in the two-body He–Xe interaction, we determined the latter by crossed-beam differential collision cross-section measurements performed at two energies (67.2 and 22.35 meV). These scattering data together with room-temperature bulk diffusion data are then fitted with a Hartree–Fock–dispersion–type function to yield an interaction potential that explains most of the properties of this system within the experimental errors and represents an improvement on previously published He–Xe potentials. Helium diffraction measurements are then carried out from the Xe overlayer and the dependence of the specular intensity from the angle of incidence is carefully determined. Further, a He–surface potential is constructed by adding together the following terms: (1) the He–Xe pairwise sum, (2) the long-range He–(0001)C interaction, (3) the three-body contribution generated by the Axilrod–Teller–Muto term, (4) the so-called surface-mediated three-body interaction He–Xe–(0001)C first considered by A. D. McLachlan [Mol. Phys. 7, 381 (1964)], and finally (5) a small correction which is meant to take into account the nonstationary nature of the surface. Using this potential, well-converged close-coupling scattering calculations are carried out, and their results compared with the data. In general, good agreement is obtained. The agreement can, however, be improved by (a) an increase of about 30% in the contribution of three-body forces, (b) the lowering of the He–graphite long-range attraction coefficient by about 15%, or (c) a reduction of the two-body interaction well depth of 1.6% (the experimental error) together with any combination of the factors under (a) and (b) reduced by an adequate amount. Elimination of the contribution of the graphite surface by studying Xe multilayers is hindered by the uncertainties in the "thermal correction'' [point (5) above] which, due to the multilayer increased "softness,'' becomes an appreciable source of uncertainty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    Journal of Mathematical Physics 28 (1987), S. 1844-1847 
    ISSN: 1089-7658
    Source: AIP Digital Archive
    Topics: Mathematics , Physics
    Notes: It is shown that Einstein's equations are always linearization stable around any finite region of space-time. Let (Ω,g0ab ) be any region of space-time, admitting a compact Cauchy surface with nonempty smooth boundary, and with g0ab a sufficiently smooth solution of the vacuum Einstein equation. It is shown that for any solution g1ab of the linearized equation and any open region U⊆Ω, there exists a smooth one-parameter family gλab of solutions on U such that (gλab||λ=0 =g0ab ) ||U and ((d/dλ)gλab =g1ab )||U. By using a result of Choquet-Bruhat and York [The Cauchy Problem, General Relativity and Gravitation, edited by A. Held (Plenum, New York, 1980), Vol. 1] asserting the smoothness of the map that sends initial data into solutions of Einstein's evolution equations the proof of the above theorem is reduced to the proof of a similar theorem for Einstein's constraint equations. The proof of this latter theorem involves the use of the implicit function theorem in Hilbert spaces. This local result on linearization stability asserts, in contrast to the general global case, that linearization about any vacuum solution is locally physically meaningful.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1573-7284
    Keywords: Chlamydia trachomatis ; Serology (ELISA) ; Urogenital infections ; Adnexitis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The diagnostic value of different laboratory methods in detecting Chlamydia trachomatis infections in high risk groups was analysed. The efficiency of a direct specimen test was compared with serology (IgG and IgM ELISA) and culture in L929 cells, stained either with fluorescein conjugated monoclonal antibodies or with iodine. Patients (no. = 1041) with localized genital infections attending a STD clinic, sexual contacts and patients with ascending infections from urological and gynecological clinics were examined. Chlamydia trachomatis was detected in 225 patients: 210 (93.3% were reactive in the direct test (smears stained with monoclonal antibodies), whereas culture missed only 5 (sensitivity 97.8%) when stained by the same method. Cultures stained with iodine produced the lowest recovery rate (73.8%), but this rate increased to 80.9% when a second passage was performed. In addition the prevalence of Neisseria gonorrhoeae, Mycoplasma hominis, Ureaplasma urealyticum, Candida albicans and Trichomonas vaginalis was investigated. In patients with non-gonococcal urethritis (no. = 331) and cervicitis (no. = 353), Chlamydia trachomatis was isolated in 32.3% and 12.8% respectively. However, this pathogen could be isolated in only 3 (15.8%) out of 19 patients with epididymitis and 15 (14%) out of 107 patients with adnexitis, although 66.7% and 93.3% respectively had specific IgG antibodies. Specific IgM could by detected with a sandwich ELISA in patients with adnexitis (46.7%), epididymitis (33.3%), cervicitis (22.2%), non-gonococcal urethritis (14%) and in the sexual partners of patients with genital infections (35.7%). The direct specimen test with monoclonal antibodies is the method of choice for the diagnosis of a C. trachomatis infection in patients with urethritis and cervicitis. In ascending infections of the genital tract, however, even culture may give negative results, and serology may be of diagnostic assistance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 312 (1984), S. 150-152 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Figure 1 shows the areas from which the samples are derived. The deciduous oaks ( Quercus petraea and Quercus robur) used for both the German and Irish tree-ring studies show several marked differences from the bristlecone pines. They all grew at low altitude (〈200 m in Ireland and 400 m in ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...