Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Archives of gynecology and obstetrics 231 (1981), S. 51-56 
    ISSN: 1432-0711
    Schlagwort(e): Dizygotic twinning ; Implantation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Two ova implanted in one uterus were found at the autopsy of a 28-year-old woman. The ovulation age of both implantations has been estimated to be 10–12 days. The presence of two equally large corpora lutea, one in each ovary, indicates that the implanted ova originated from different ovaries. Thus, an “ovulatio biovarialis” seems to be the basis for the dizygotic twinning in this case. The case is believed to be the only documented example of a very early dizygotic, fraternal pregnancy in humans.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    The @journal of organic chemistry 20 (1955), S. 819-822 
    ISSN: 1520-6904
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    The @journal of organic chemistry 26 (1961), S. 2486-2491 
    ISSN: 1520-6904
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 76 (1954), S. 5799-5801 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 86 (1964), S. 1889-1890 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 79 (1957), S. 1011-1012 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Pure and applied geophysics 155 (1999), S. 57-80 
    ISSN: 1420-9136
    Schlagwort(e): Key words: Fog prediction, radiation fog, numerical fog modeling.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Geologie und Paläontologie , Physik
    Notizen: Abstract —A simple one-dimensional numerical-analytical model was developed by Meyer and Rao (1995) to predict the onset of radiation fog. The model computes radiative cooling and turbulent diffusion of heat and vapor through the lower boundary layer and produces heat and vapor fluxes at the soil–atmosphere interface. The model is designed for Air Force forecasters who have access to a personal computer, an early evening surface observation of the dry bulb and dewpoint temperature, wind speed, the lapse rate in the upper boundary layer, and the previous 24-h precipitation amount. These initial data are used to predict the diurnal variation of the dry bulb and dewpoint temperatures at 10 m above the surface. In accordance with conventional synoptic observing practices, fog is defined as a restriction of the surface visibility generally to less than 1000 m. Fog is assumed to occur in the model predictions when the dewpoint depression falls to less than 1°C. Observations, from several Air Force bases for selected days when fog was observed to occur, were used to test the model. The present model with default parameters appears to predict the onset of fog slightly ahead of its occurrence. Better verification results are expected when site-relevant parameters are used in model predictions.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Electrical engineering 69 (1986), S. 41-48 
    ISSN: 1432-0487
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik
    Beschreibung / Inhaltsverzeichnis: Contents By means ofhpn- andhsz-components power system analysis can be carried out with minimal effort and measuring results have maximum contents of information. The most important elementary space-phasors of real time-functions are given inhpn- andhsz-components.
    Notizen: Übersicht Inhpn- undhsz-Komponenten lassen sich Netzberechnungen mit minimalem Aufwand durchführen und Meßgrößen mit maximalem Informationsgehalt gewinnen. Es werden die wichtigsten elementaren Ortskurven reeller Zeitfunktionen inhpn- undhsz-Komponenten angegeben.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Electrical engineering 66 (1983), S. 29-36 
    ISSN: 1432-0487
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik
    Beschreibung / Inhaltsverzeichnis: Contents The method of current splitting can be extended for arrangements with diversified permeable spaces. Accordingly, model equations are put foreward, which transfer the original to a model of constant permeability. Discontinuities of magnetic field strength, occuring in this model, yield to distributed currents in the boundary surface. The method of current splitting extended in this way, is applied to the current calculations of a metal-clad conductor and compared with the analytical approximation.
    Notizen: Übersicht Die Teilleitermethode ist auf Anordnungen mit unterschiedlich permeablen Gebieten erweiterbar. Hierzu werden Ähnlichkeitsbezichungen angegeben, die das Original in ein Modell konstanter Permeabilität überführen. Die in diesem Modell auftretenden Sprünge der magnetischen Feldstärke ergeben Strombeläge in den Grenzflächen der Gebiete. Die derart erweiterte Teilleitermethode wird auf die Berechnung des Stromes im Mantel eines Rohrleiters angewandt und mit der analytischen Näherungslösung verglichen.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Electrical engineering 70 (1987), S. 291-301 
    ISSN: 1432-0487
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik
    Beschreibung / Inhaltsverzeichnis: Contents Calculating transients in power systems it is advantageous to use symmetrical components. The example of the most common three-phase bridge converter shows that also current converters can be described in space phasors. With respect to the characteristics of conducting valves the networks and the conditions of firing and commutation ending are deduced. Numerically calculated results agree with measurements. A parameter study shows the typical space phasor curves of bridge converter currents.
    Notizen: Übersicht Dynamische Netzberechnungen lassen sich vorteilhaft in Drehstrom-Modalkomponenten durchführen. Das Beispiel der meistgebräuchlichen Drehstrom-Brückenschaltung zeigt, daß auch Stromrichter mit Raumzeigern beschrieben werden können. Unter Berücksichtigung der Eigenschaften stromführender Ventile werden die Ersatzschaltpläne sowie die Zünd- und Löschbedingungen in Modalkomponenten hergeleitet. Die Ergebnisse numerischer Berechnungen stimmen mit Messungen überein. Eine Parameterstudie zeigt die für Brückenschaltungen typischen Stromortskurven in Modalkomponenten.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...