Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (775)
  • 1981  (775)
  • Cell & Developmental Biology  (686)
  • Gas chromatography  (89)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 315 (1981), S. 219-225 
    ISSN: 1432-1912
    Keywords: 3-Methoxytyramine ; Haloperidol ; Dopamine release ; Dopamine agonists ; Gas chromatography ; Mass Spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The value of 3-methoxytyramine (3-MT) as an indicator of impulse-related dopamine (DA) release has been assessed in rat corpus striatum. Moreover, the turnover of 3-MT was estimated by measuring its disappearance rate after COMT inhibition. Quantitation of 3-MT and DA was performed by gas chromatography/mass spectrometry (selected ion monitoring). Haloperidol in doses between 0.05 and 3 mg/kg p.o. did not increase endogenous 3-MT levels at any time up to 24 h after its administration, whereas it dose-dependently increased homovanillic acid and 3,4-dihydroxyphenylacetic acid. However, in doses above 0.1 mg/kg p.o., it enhanced the accumulation of 3-MT in clorgyline-pretreated animals. Conversely, baclofen in doses of 2 mg/kg i.p. and above decreased endogeneous 3-MT levels, but reduced the accumulation of this amine only poorly at 20 mg/kg i.p. in clorgyline-pretreated rats. A number of dopamine agonists, apomorphine (0.5 mg/kg i.v.), dipropyl-ADTN (0.03 mg/kg i.v.), but not bromocriptine (1 mg/kg i.v.) reduced endogenous 3-MT levels 10 min after administration by approximately 50%. The DA releasing agents d-amphetamine and methylphenidate showed different effects: the former increased endogenous 3-MT greatly, whereas the latter was without effect. The difference is likely to be related to the MAO inhibitory properties of amphetamine. 3-MT disappeared rapidly after COMT inhibition with 50 mg/kg i.v. tropolone (half-life of the initial disappearance about 1 min). The curve flattened off after 5–10 min. Turnover was calculated to be about 7 nmol/g/h, which corresponds to about a third of the turnover of DA. Our results suggest that an important part of DA metabolism occurs through 3-MT and that this amine is very effectively deaminated by MAO-A, so effectively indeed that increased formation does not increase its endogeneous levels. It appears, therefore, that 3-MT is not suitable as an indicator of increased DA release. However, it seems to have some value for an assessment of lowered DA release.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 48 (1981), S. 319-324 
    ISSN: 1432-1246
    Keywords: Chlorophenols ; Gas chromatography ; Hexachlorocyclohexane ; Metabolites
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A sensitive and specific gas chromatographic method is described for the simultaneous determination of ten chlorinated phenols that appear in the urine of persons exposed to hexachlorocyclohexane (HCH). The phenolic compounds in the urinary samples are hydrolysed in an acidic medium and derivatised with acetic anhydride. This sample treatment permits routine application. The stationary phase (8% DC 200 on Chromosorb G AW-DMCS possesses a high separating capability for the acetic esters of the chlorophenols. The detection limits lie between 4.9 and 18.6 μg/l and allow determinations even in the environmentally interesting concentration range. The recoveries determined using aqueous standards range between 87 and 119% and the relative standard deviations are between 4.4 and 10.1%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 75 (1981), S. 179-183 
    ISSN: 1432-2072
    Keywords: DMT ; Gas chromatography ; Hyperactivity ; Pargyline ; SKF-525A ; Mice
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Mice pretreated with the monoamine oxidase inhibitor pargyline showed a dose-dependent increase in hyperactivity for up to 2 h following injections of N,N-dimethyltryptamine (DMT: 0.5–8.0 mg/kg). Hyperactivity was related to a linear increase in whole brain concentrations of DMT as measured by a new sensitive gas chromatographic assay. The duration of this behaviour paralleled the concentration of DMT in the brain from 15–120 min. However, at 15 min, there was no significant difference in brain DMT concentrations between mice receiving pargyline and those given distilled water at the two dose levels of DMT studied (2.0 and 8.0 mg/kg). Pre-treatment with the microsomal enzyme inhibitor SKF-525A, alone or in combination with pargyline, had no effect on the DMT-induced behaviour or on the brain levels of DMT.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 48 (1981), S. 99-106 
    ISSN: 1432-1246
    Keywords: Urine analysis metabolites ; Gas chromatography ; Hexane ; Cyclohexane ; Biological monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A gas chromatographic method for analyzing the urinary metabolites of n-hexane (2-hexanol, 2,5-hexanedione, 2,5-dimethylfuran and γ-valerolactone), of 2-methylpentane (2-methyl-2-pentanol), of 3-methylpentane (3-methyl-2-pentanol), and of cyclohexane (cyclohexanol) was developed. Processing of urine and the gas chromatographic conditions are described. The recovery rate of all hexane metabolites, except 2,5-dimethylfuran, ranged between 92 and 100%. The variation coefficient of metabolites determination was between 1.5 and 5%, apart from 2,5-dimethylfuran determination for which the variation coefficient was 15%. The detection limits ranged between 0.2 and 0.7 mg/1 and between 0.05 and 0.1 mg/1 when a packed or capillary column was used. Results obtained from a packed and capillary column are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 49 (1981), S. 115-123 
    ISSN: 1432-1246
    Keywords: Blood analysis of solvents ; Gas chromatography ; Head space ; Toxicokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The determination of toluene, benzene, ethylbenzene and trichloro-ethylene in blood by means of a gas chromatographic head space technique is presented. Internal standards are added to the blood samples in the form of water solutions of volatile hydrocarbons in proportion 2:1. This enables application of the internal standard within the broad range of concentrations and in addition increases significantly the concentrations of investigated compounds in the gas phase of incubation vessel. Elaborated methods were applied for determinations of ethylbenzene in blood samples collected after experimental inhalation exposure and for evaluation of the rate of disappearance of benzene, toluene and trichloro-ethylene from blood after acute accidental or suicidal intoxications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 601-602 
    ISSN: 1612-1112
    Keywords: Ethanolamines ; Ethylene glycols ; Direct separation ; Gas chromatography ; Short glass capillaries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An effective and rapid GC separation of ethanolamines, even in the presence of ethylene glycols, using short glass capillary columns is developed. No preliminary derivatisation of the sample is necessary. The separation is completed in 6 minutes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 143-147 
    ISSN: 1612-1112
    Keywords: Capillary columns ; Gas chromatography ; Retention index ; Structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention index of twenty different homologous series of esters have been determined experimentally on polar (Carbowax 1540) and non-polar (squalane) columns. General equations to calculate retention index have been established by statistical methods. The influence of the length and inductive effect of acid and alcohol chains and the relative position of the carboxylic group are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 285-288 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Porous layer open tubular columns ; Kaolin as support ; Column performance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PLOT columns have been prepared with kaolin as the liquid phase support. These columns show good efficiency with different stationary phases and good thermal stability with polar phases. The performance of columns is shown by the separation of various mixtures such as fatty acids, phenols and anilines which are of analytical importance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Urea herbicides ; Catalytic hydrolysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the rapid catalytic hydrolysis of phenylurea herbicides on silica gel at elevated temperatures. After derivatisation of the anilines produced with heptafluorobutyric acid anhydride final analysis is done on a gas chromatograph equipped with an electroncapture detector. Detection limits are in the 1–5 picogram range. The method has successfully been applied to residue analysis of water samples at the 1 ppb level. The determination of free anilines present in water samples and the potential of various techniques to be used to discriminate between free anilines and parent herbicides are also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polycyclic aromatic hydrocarbons ; Retention index ; Average molecular polarizabilities
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A significant correlation has been found between the retention indices of polycyclic aromatic hydrocarbons on non-polar stationary phases and the average molecular polarizabilities of the molecules separated on these phases. Equations have been derived for the determination of the average molecular polarizabilities, directly from the retention indices.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 69-72 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Polynuclear aromatic hydrocarbons ; Retention index ; Vapour pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention index of a planar polynuclear aromatic hydrocarbon on the GC phases OV-101, SE-52, and OV-17 is strictly related only to the boiling point, and less closely to the relative molecular mass. The very approximates relation with connectivity index ins only a consequence of the latter. On a nematic lqiuid crystal phase, a variation of activity coefficient, expressed in terms of a shape factor, also influences the retention of PAH.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 269-276 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detector performance ; Trace analysis ; Catalytic conversion ; Multidimensional gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Relationships are derived describing how the detection limit of a chromatographic system depends on the minimum detectable limit of the detector and the chromatographic parameters such as column length, efficiency, carrier gas flow rate and the capacity factor. Performance data of detectors developed in the last 25 years at the Dalian Institute of Chemical Physics of the Chinese Academy of Sciences are given and a few selected application examples are listed. These include trace analysis by preconcentration and by direct analysis and the utilization of multidimensional gas chromatography with two columns, two detectors, a 12-port valve, and a catalytic conversion reactor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1612-1112
    Keywords: Gas chromatography ; C1−C5 Hydrocarbons ; Dimethyl ether
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An analytical GC method was developed which uses a single packed column consisting of three packings in series prepared with the following liquid phases: dimethyl sulfolane, propylene carbonate, and silver nitrate. This system provides satisfactory resolution of mixtures of C1−C5 hydrocarbons and dimethyl ether obtained when converting methanol to gasoline. Due to the high capacity of the column it is possible to inject larger sample amounts permitting trace analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Phthalides ; Umbelliferae ; Liquid-solid chromatography ; Gas chromatography ; Ligustilide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid-solid chromatographic pre-fractionation of naturally occurring phthalides has been developed. The LSC was carried out on a column of silica applying a 1–50% gradient elution of diethyl ether (containing 2% methanol) in pentane. The enrichment in the fractions led to better possibilities for a gas chromatographic separation and isolation allowing further studies by spectroscopic methods. Ligustilide may easily isomerize during GC as a result of ageing of the column.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 19-22 
    ISSN: 1612-1112
    Keywords: Teflon columns ; Chemically modified teflon ; Gas chromatography ; Capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Wall-coated open tubular columns prepared from chemically modified teflon tubing have been developed for gas chromatography. Chemical reaction of the inner walls of teflon tubing allows bonding of an adhesive layer on which a variety of stationary phaes can be coated. Test mixtures of alkanes and alcohols were used to investigate the chromatographic properties of these columns and the stability and mixing of the adhesive and stationary phae layers. the results in dicate that mixing of the layers is negligible and that the column is stable for a long period of time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 14 (1981), S. 55-66 
    ISSN: 1612-1112
    Keywords: Capillary columns, glass ; Gas chromatography ; Column preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kapillar-Gas-Chromatographie ist heute das sich am stärksten entwickelnde Gebiet der Gas-Chromatographie. Es gibt viele komplexe, neue Fragestellungen in der Analytik, welche den Einsatz spezieller Kapillarsäulen erfordem. Glücklicherweise gibt es aber auch eine große Zahl von Herstellungsverfahren für Kapillarsäulen, welche — noch mehr als bei der Herstellung von gepackten Säulen — eine Anpassung an die gestellten Aufgaben ermöglichen. In diesem Artikel werden die Herstellungsverfahren für Kapillarsäulen zusammengestellt und Anregungen gegeben, wie aufgaben-orientierte Säulen erreicht werden.
    Notes: Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns, Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 329-347 
    ISSN: 0886-1544
    Keywords: actin ; microfilaments ; heavy meromyosin ; mammary gland ; secretion ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Cytochalasin B, a microfilament-altering drug, inhibits lactose synthesis in lactating guinea pig mammary gland [Biochim. Biophys. Acta 392:20, 1975] but not primarily by inhibiting glucose transport [Eur. J. Cell Biol. 20:150, 1979]. In order to study the possible role of microfilaments in lactose synthesis and secretion, we isolated both the alveolar (milk-secreting) and myoepithelial (contractile) cells from lactating mammary gland. Light microscopy shows that the alveolar cell fraction (viability approximately 71%) is homogenous and that the cells retain strong polarity of secretory structures in the apical region. Two proteins were extracted from the alveolar cell fraction. One (mol wt 42,000) comigrates with skeletal muscle actin on SDS-PAGE gels. The other, a high-molecular-weight (180,000) protein (HMWP) may be analogous to actin-binding protein or clathrin. An extract from the myoepithelial cell fraction also contains a protein that comigrates with actin but no HMWP. Whole tissue extract contains the 42K protein, and a 185K HMWP. Examination of the alveolar cell extract by electron microscopic (EM) negative staining revealed meshworks of multistranded, interconnecting filaments, with attached globular structures (100-200 A) (possibly the HMWP) and single filaments (40-60 A diameter) branching off. To localize these filamentous structures in situ, whole tissue was glycerinated and incubated with rabbit skeletal muscle heavy meromyosin (HMM). Masses of filaments in myoepithelial cells served as convenient standards for HMM decoration. Decorated filaments have cross-arms or projections, unlike the narrow, smooth filaments of control tissue. Decorated filaments in alveolar cells are located beneath the plasma membrane, in close association with secretory vacuoles, and near the Golgi apparatus; filaments near the latter two are often oriented perpendicular to the plasma membrane. Microvesicles are embedded in meshworks under the plasmalemma and near the Golgi apparatus. Intermediate-sized (85-115 A diameter), non-decorated filaments diverge from the meshworks of decorated filaments. Microvesicles are associated with intermediate-sized filaments as well. The association of actin-like filaments with secretory vacuoles and microvesicles and their location in areas of the cell concerned with biosynthetic activities suggest a possible function in the intracellular transport of secretory products.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 387-397 
    ISSN: 0886-1544
    Keywords: birefringence ; polarizing microscope ; sea urchin egg ; cortex ; mitosis ; cleavage ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Birefringence (BR) at the cell surface of fertilized eggs of the sand-dollar, Clypeaster japonicus, during mitosis and cleavage was determined with a photoelectric BR detection apparatus [Hiramoto et al, 1981a]. The cortex of about 2 μm thickness is birefringent positive with respect to the normal to the cell surface. The hyaline layer is negatively birefringent. The halo-layer consisting of a row of microvilli surrounding the egg is positively birefringent in normal Ca-free sea water, while it is negatively birefringent in Ca-free sea water with high refractive index. The BR of the cortex gradually increases over the entire surface during mitosis until the onset of cleavage. The BR of the cortex at the polar region reaches a maximum shortly after the onset of cleavage and then decreases, while the BR of the cortex at the equatorial region begins to decrease shortly before the onset of cleavage, reaches a minimum shortly after the cleavage starts, and then increases again as the cleavage furrow advances. The coefficient of birefringence of the cortex is about 2.5 × 10-5 at the maximum. The BR change of the cortex during mitosis and cleavage is interpreted as a passive deformation caused by the constriction of the contractile ring as well as an active structural change of the cortex occurring in the dividing cell.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981) 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 371-385 
    ISSN: 0886-1544
    Keywords: rotating filaments ; cytoplasmic streaming ; Nitella ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Our knowledge about the actin-containing characean filaments on the basis of light and electron microscopical investigations is reviewed. Dynamic filamentous networks, known already from isolated droplets, were detected in Nitella rhizoidal cells using light microscopical techniques. Earlier light microscopic observations in cytoplasmic droplets are confirmed and complemented by new model experiments with rotating helices. The motile phenomena occurring at the filament bundles (ring formation, wave propagation, particle translocation, net dynamics, rolling motions, formation of side arms) can, in this way, be imitated in detail. Thus, the concept of cytoplasmic streaming as a translocation along bundles of rapidly rotating helical filaments is supported. In order to explain unidirectional cytoplasmic streaming, a periodic winding up and unwinding of fine filaments is postulated by which ions are periodically bound and displaced. The formation of side arms which is favored during unwinding results in a screw-mechanical different behavior of the filaments in the two directions of rotation and therefore causes permanent particle transport in one direction.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 417-431 
    ISSN: 0886-1544
    Keywords: spindle poles ; centrioles ; cell center ; scaffold ; electron microscopy ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: I have used fluorescence microscopy and antibodies to 10nm filaments and tubulin labelled with contrasting fluorochromes to compare the distribution of these proteins in endothelial cells during cell division. During interphase the two filament systems have entirely different distributions: The bulk of the 10nm filaments form a ring that surrounds the cell center and nucleus and remains parallel to the substrate, while the microtubules radiate from the cell center to the cell's border. When the mitotic spindle replaces the radial microtubule pattern in mitosis, the spindle poles remain within - and in close proximity to - the ring of 10nm filaments. This was confirmed by electron microscopy which showed the ring and centrioles in the same plane separated by a distance of 300-400 nm.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 433-443 
    ISSN: 0886-1544
    Keywords: Physarum ; acellular slime mold ; calcium ion ; calcium-ionophore ; cytoplasmic contraction ; oscillation ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Calcium is now generally thought to play a key role in regulating a variety of cellular movements. When the plasmodium of Physarum polycephalum was treated with the calcium-ionophore A23187 or the quasi-ionophore amphotericin B, Ca2+ leaked out. Ca2+ efflux into the ambient solution from the plasmodial strand segment was measured by the luminescence of a photoprotein aequorin, and the tensile force production was recorded simultaneously. Ca2+ efflux oscillated with the same period as the cycle of tension generation in the strand, but the phase of cyclic changes in Ca2+ efflux was opposite to that of tension generation. That is, Ca2+ efflux fell in the increasing tension phase and rose in the decreasing tension phase. Cyclic changes in efflux of Ca2+ are provisionally interpreted as reflecting corresponding changes in concentrations of free Ca2+ in the cytoplasm.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 445-454 
    ISSN: 0886-1544
    Keywords: taxol ; microtubules ; polymerization ; tubulin ; mitotic inhibitor ; protein self-assembly ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Dissociated bovine brain microtubule protein has been shown to reassemble at 0°C in the presence of the drug taxol. Tubulin polymerization was monitored both by electron microscopy of the polymeric structures and by incorporation of tritiated GTP into filterable polymeric structures. Most of the labeled guanine nucleotide uptake into tubulin polymeric structures occurred in the first 30 minutes of incubation with the drug. The initial polymerization event results in the formation of protofilamentous tubulin ribbons. The first microtubules were noted after 1 hour of incubation with the drug. After 20 hours of incubation at 0°C with taxol, the bulk of the polymerized tubulin appeared to be in the form of microtubules. Cold-stable tubulin rings with a mean diameter of 34 nm were present in the reaction mixture before the addition of taxol and throughout the 20-hour incubation. Most of the rings were apparantly not involved in the taxol-induced microtubule assembly. The results are consistant with a model whereby taxol induces an initial formation of protofilamentous ribbon structures, mostly from free tubulin dimers, and a slower subsequent folding of the ribbon structures into microtubules.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 455-468 
    ISSN: 0886-1544
    Keywords: intercellular bridge ; intercellular communication ; cytokinesis ; squid ; ultrastructure ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Incomplete cytokinesis followed by the disappearance of the midbody and spindle remnant results in intercellular bridges between the cells of the blastoderm of the squid embryo. An electron microscope study of the morphology of the stages of development of the intercellular bridge is presented. Cytokinesis ceased as the furrow base reached a diameter slightly larger than the midbody. As furrowing stopped, a dense material accumulated to form a cylindrical sheath 50 nm thick, lining the inner surface of the furrow base. Proteolytic enzymes showed this material to have a significant protein component. As the midbody broke down, vesicles lined the inner surface of the bridge sheath. In this configuration, there was cyto-plasmic continuity between the cells, and organelles appeared to pass through the bridge.The intercellular bridge could become temporarily closed. Vesicles entered the channel and fused with the vesicles lining the inner surface of the sheath. The vesicles enlarged until the channel became occluded with a series of transverse cisternae, the edges of which were embedded in the material of the sheath. When the bridge reopened, the transverse cisterna appeared to dissociate from the sheath, move out of the channel, and break down. Occasionally bridges were seen in which the bridge wall appeared distorted into lobes. It is suggested that such bridges might be in the porcess of breaking down, resulting in the final separation of the cells.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 499-515 
    ISSN: 0886-1544
    Keywords: dynein ; tubulin ; axonemes ; microtubules ; microtubule-associated proteins ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Microtubule-associated proteins (MAPs), isolated from brain tubulin, bound to and saturated outer fibers of Chlamydomonas flagella. MAPs present on these microtubules prevented the subsequent recombination of dynein. MAPs also bound to intact axonemes and thus did not specifically bind to the dynein binding sites on the A subfiber. A molar ratio of 1 mole MAP2 per 27 moles tubulin dimers at saturation of the outer fibers with MAP2 suggested that MAPs could effectively interfere with dynein recombination only if the MAPs were near the dynein binding sites to sterically prevent binding. However, electron microscopic observations indicated that MAPs were not localized but, instead, were dispersed around the outer fibers. In addition, MAP2 present at saturating amounts on in vitro assembled brain microtubules had no significant effect on dynein binding. Dynein-decorated microtubules contained clusters of arms suggesting that there may be cooperative interaction between the arms during dynein binding. Because the A subfiber of axonemes contains sites to which dynein preferentially attaches, MAPs may prevent recombination by interfering with cooperative binding to these specific sites. Dynein presumably binds with equal affinity to any protofilament on in vitro assembled microtubules, and, therefore, the MAPs may not be capable of effectively interfering with cooperative binding of dynein to these microtubules.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 469-483 
    ISSN: 0886-1544
    Keywords: microtubules ; nucleation ; mitosis ; nocodazole ; immunocytochemistry ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The reassembly of microtubules is described in mitotic cells after release from nocodazole-induced block. The formation of microtubules was followed by light microscopic immunocytochemical staining using the PAP method, combined with to-luidine blue staining of the chromatin. The light microscopic observations on whole cells were compared with ultrastructural observations on thin sections. This step is essential to ascertain complete destruction of microtubules during the nocodazole treatment and to correlate immunocytochemical staining with the presence of microtubules.Removal of nocodazole (10 or 1 μg/ml) after a sufficiently long incubation to induce a complete disappearance of microtubules resulted in the appearance of tubulin staining specifically associated with the centromeres and with one or two isolated points in the cytoplasm. Electron microscopy confirmed that the staining was due to the massive accumulation of small microtubules at the kinetochores and centrosomes. Kinetochore nucleation was seen only in association with condensed metaphase-stage chromosomes and not with the less-condensed prophase chromosomes.In a second type of experiment cells were allowed to enter mitosis in the presence of an incompletely active concentration of nocodazole (0.1 μg/ml). The construction of the mitotic spindle was arrested; however, short microtubules were assembled at the kinetochores and centrosomes.These experiments demonstrate that in living mitotic PTK2 cells the kinetochores, as well as the centrosomes, exert a nucleating action on tubulin assembly.The further elongation of microtubules after removal of nocodazole was seen to occur preferentially along axes between the centrosomes and the kinetochores. This resulted in the construction of normal metaphases that evolved through anaphase and telophase. We have attempted to formulate a hypothesis that may explain the oriented assembly that seems to be essential in the construction of the spindle.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981) 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 167-178 
    ISSN: 0886-1544
    Keywords: nerve growth ; actin ; tubulin ; antibodies ; immunofluorescence ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Embryonic chick nerve cells, from dissociated dorsal root ganglia, were cultured on polylysine substrata and examined for tubulin and actin distribution by indirect immunofluorescence.Antibodies generated against chick brain tubulin produced specific fluorescence in growth cones, neurites, and cell bodies without revealing distribution differences or substructure in the nerve cells. However, at reduced antitubulin concentrations, differences were resolved. Tubulin fluorescence remained uniform and intense in neurites and cell bodies, but exhibited reduced intensity and patterning in growth cones. Nonneuronal cells in the reduced intensity and patterning in growth cones. Nonneuronal cells in the cultures served as controls for typical cytoplasmic tubulin fluorescence distribution. Straining controls demonstrated that fluorescence resulted from tubulin-antitubulin binding.Analogous studies, using antibodies generated against chick brain actin, demonstrated distribution differences at reduced antiactin concentrations, including “hot spots” of intense fluorescence in growth cones and a paucity of fluorescence in neurites.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 193-203 
    ISSN: 0886-1544
    Keywords: polygonal network ; rat aortic smooth muscle cell ; cell culture ; electron microscopy ; amino acid analysis ; elastin ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Cultured rat aortic smooth muscle cells (SMC) were examined by electron microscopy and found to contain polygonal networks of 75 A° thin myofilament bundles. The cells also had large bundles of longitudinally aligned thin myofilaments with periodically spaced dense bodies. Abundant plasmalemmal vesicles were present at the cell periphery, and the cells were connected by desmosomes. Intercellular spaces contained sparse amounts of elastic fibers, a material generally present in SMC cultures. Analyses of amino acids by automated column-chromatography showed that isodesmosine and desmosine, two amino acid residues unique for elastin, were present. Accordingly, it was concluded that polygonal networks, previously detected solely in cultured nonmuscle cells, were present in SMC.Other findings suggest (1) a change in myofilament arrangement takes place during cell migration, and (2) rat aortic SMC grown in tissue culture flasks is an important experimental tool in the study of cell motility since such myofilament rearrangements were observed to occur up to fourteen days in first passage.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 179-192 
    ISSN: 0886-1544
    Keywords: actin ; echinoderm ; fascin ; filopodia ; actin cross-linking protein ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Echinoderm coelomocytes transform from petaloid cells with large motile lamellipodia to filopodial forms. During this morphological transformation, actin filaments extensively reorganize from a random meshwork into tight bundles, which become the skeletons or cores of the filopodia. Antibody localization procedures show that fascin, a 58,000 dalton actin cross-linking protein, becomes incorporated into the filament bundles as they form. Isolated filopodial cores have a pronounced transverse striping pattern, which has been previously identified with fascin crosslinks, and gel electrophoresis identifies a protein in the cores that co-migrates with purified egg fascin. A few of the core fragments also have a distinctive “cap,” which we presume is the membrane insertion site for actin filaments.We have developed a radioimmunoassay for fascin and have used it to study the redistribution of this protein during transformation. Data from the assay indicate that fascin constitutes about 5% of the total cell protein and that substantially more fascin, approximately 1.5-2 times more, is found in the Triton-insoluble cytoskeletons of the filopodial cells than in the petaloid cells. Actin, measured by the DNAase I inhibition assay accounts for approximately 10% of the total cell protein. Approximately 65% of this actin is in a soluble non-filamentous form in the petaloid cells. Our results show that actin polymerization must occur during the cell shape change, since we find approximately 25% more actin in the filopodial cytoskeleton than in the petaloid cytoskeleton. The results show a preferential incorporation of fascin into the cytoskeleton as the cells form filopodia.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 205-235 
    ISSN: 0886-1544
    Keywords: capping of receptors ; cell locomotion ; cell-surface interactions ; frictional force ; membrane flow ; polymorphonuclear leukocytes ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: As a cell moves over a surface, the distribution of membrane proteins that adhere to the surface will be changed relative to the distribution of these molecules on a static cell. Observations of this redistribution offer, in principle, evidence as to the mechanisms of membrane dynamics during cell locomotion. Toward extracting such information we present and analyze a mathematical model of receptor transport in the membrane by diffusion and convection, as affected by the making and breaking of the bonds between the receptors and the surface as the cell moves.We show that the disruption of receptor-surface bonds at the tail of the cell provides a mechanism by which the frictional force opposing a cell's motion is exerted, and calculate the magnitude of this force as a function of cell velocity. Assuming this to be the major contribution to the frictional force, we show that when the shear force on a cell is above a critical value it is no longer possible for the cell to slide across the surface. For such large forces, it is still possible for the cell to roll; alternatively the cell can be torn free of the surface.Our analysis of existing data on movement of polymorphonuclear leukocytes indicates that cell motion is not accompanied by a bulk flow of membrane from the front to the back of the cell. The data also indicate that cells do not tend to roll as they move over a surface under normal conditions. The data are most consistent with a model where the membrane as a whole is stationary but where receptors that bind to the surface become coupled to sub-membrane contractile proteins.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 269-272 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 261-268 
    ISSN: 0886-1544
    Keywords: Tetrahymena ; chemotaxis ; temporal-gradient sensing ; modulation of turning frequency ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The motility pattern of Tetrahymena thermophila in a homogeneous attractant field consists of successive “runs” and “turns.” The turning frequency decreases or increases upon an abrupt increase in attractant or repellent concentration, respectively. The dose-response curve for leucine and methionine yields a saturation curve with half maximum modulation of the turning frequency at a concentration of 15 μM and 2 μM, respectively. The turning frequency is modulated at a threshold concentration of 0.02 μM and 0.50 μM for leucine and methionine, respectively. The decrease (increase) in turning frequency in the presence of an attractant (repellent) jump reverts to prestimulus frequency in a time proportional to the concentration jump. Hence, Tetrahymena seem to employ temporal-gradient sensing for chemotaxis. Spatial-gradient taxis is thus exerted by random walk, which is biased in the direction of the gradient.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 237-245 
    ISSN: 0886-1544
    Keywords: centrioles ; symmetry ; triplet blades ; thermal fluctuations ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The paper suggests several principles of construction of a microscopically small device for locating the directions of signal sources in microscopic dimensions. It appears that the simplest and smallest device that is compatible with the scrambling influence of thermal fluctuations as are demonstrated by Brownian motion is a pair of cylinders oriented at right angles to each other. Nine equally spaced blades run in a pitched fashion along the mantle of each cylinder. The blades have a concave cross-section and bend around the circumference of the cylinder in a certain rotational pattern. Considering the striking similarity of this hypothetical device with centrioles, the paper puts forward the conjecture that centrioles locate the direction of hypothetical signals inside cells.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 349-362 
    ISSN: 0886-1544
    Keywords: Ca2+ ; flagella ; symmetry ; vanadate ; spermatozoa ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Increased Ca2+ concentration causes a reversible increase in asymmetry of the flagellar bending waves of “potentially symmetric” demembranated sea urchin spermatozoa. When these flagella are immobilized with 5 μM vanadate, increased Ca2+ concentration causes a reversible increase in the total bend angle between the tip and the base of the immobilized flagella. These effects of Ca2+, and the movement which can be activated by CaATP2-, can be inhibited by vanadate, but in both cases, high concentrations of vanadate, of the order of 100 μM, are required. These observations suggest that ATP, possibly in the form of CaATP2-, is required for the Ca2+-induced change in shape of the flagella, but other observations suggest that the magnitudes of asymmetry and total bend angle are more closely related to Ca2+ concentration than to CaATP2- concentration.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 399-416 
    ISSN: 0886-1544
    Keywords: myosin heavy chain ; avian muscular dystrophy ; adult and embryonic fast white fibers ; slow red fiber ; rod ; subfragment-1 ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Avian muscular dystrophy is characterized by the degeneration of fast white skeletal muscle fibers, with onset during development. Using a one-dimensional peptide mapping technique, we have detected two forms of the myosin heavy chain in the fast white fibers of adult domestic chickens, one form characteristic of birds homozygous for muscular dystrophy, the other of their normal controls. Four dystrophic strains carrying the same gene for muscular dystrophy were examined.No differences were detected in the embryonic heavy chain peptide maps of normal and dystrophic chickens, consistent with the developmental onset of the condition. Differences were also absent from the peptide maps of heavy chains from slow red fibers, which are unaffected in dystrophy. No dystrophy-specific peptide map differences were detected in the three light chains. Analysis of peptide maps of rod and the heavy chain component of subfragment-1 from normal and dystrophic heavy chains indicates the presence of amino acid sequence differences in the two proteins.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 247-260 
    ISSN: 0886-1544
    Keywords: cilia ; trachea ; ATP-reactivation ; ciliary activity ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Evidence for active sliding of microtubules during ciliary activity has been demonstrated in a number of organisms: sea urchin sperm flagella, protozoan cilia, and mollusc gill cilia. Although there is evidence that active sliding also occurs in mammalian sperm flagella, there is little or no information on whether active sliding of microtubules also occurs in the short (5-μm) cilia of the mammalian trachea or oviduct. Since these cilia are important in tracheobronchial clearance and ovum transport, respectively, it has been important to demonstrate that microtubule sliding is also involved in the activity of somatic cilia. Ciliated apical portions (cortices) and cilia were isolated from rabbit trachea and oviduct, using Triton X-100 to demembranate the cilia. Most of the ciliated cortices reactivated upon addition of ATP, whereas isolated cilia reactivated to a lesser extent. When preparations of cilia were digested with trypsin before or after ATP addition, disintegration of axonemal doublets occurred with about the same frequency as reactivation. These events were recorded using Nomarski optics and dark-field microscopy. When isolated cilia which had been digested by trypsin and exposed to ATP were also prepared for electron microscopy by negative staining, telescoping of doublet microtubules from axonemes could be shown. These results demonstrate that mammalian somatic ciliary doublet microtubules actively slide in a manner similar to that described for invertebrate cilia.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 273-273 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981) 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 303-327 
    ISSN: 0886-1544
    Keywords: cilia ; microtubules ; ATPase ; vanadate ; geometry of sliding ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: A dynein arm attachment cycle produces sliding between adjacent doublet microtubules (N and N + 1) of cilia. In intact axonemes, in the absence of ATP, almost all arms appear attached at both ends (rigor). When ATP is added, most arms detach from doublet N + 1. In ATP and vanadate, the arms do not return to rigor, suggesting that ATP hydrolysis is required for re-extension and reattachment of the dynein arm, but not for detachment. Using solutions containing dynein to decorate dynein-less axonemal doublets, we confirm this interpretation. In the absence of ATP, both sides of each doublet decorate with arms. Addition of ATP, ATP and vanadate or AMP-PNP causes immediate arm detachment, but only in the first instance, where extensive ATP hydrolysis can occur, does decoration eventually reappear. Dynein decorates heterologous axonemal doublets and brain microtubules, as well as homologous doublets, suggesting that this mechanochemical cycle may have general applicability in microtubule-based cell motility.
    Additional Material: 111 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 0886-1544
    Keywords: videomicroscopy ; differential interference microscopy ; streaming ; reticulopodial motility ; Allogromia ; microtubules ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: A new method called Allen Video-enhanced Contrast, Differential Interference Contrast (AVEC-DIC) microscopy is shown to be sufficiently sensitive to detect several new features of microtubule-related motility in the reticulopodial network of the foraminifer, Allogromia. The method takes advantage of the variable gain and offset features of a binary video camera to operate the DIC microscope under conditions highly favorable for video imaging, but in which the optical image is virtually invisible to the eye yet retains its full information when viewed by a suitable video camera. The improvements are made possible by setting a dé Senarmont compensator to λ/9-λ/4 at maximal working aperture of internally corrected planapochromatic objectives. Under these conditions, the offset feature of the video camera can reject so much stray light from the instrument and specimen that contrast compares favorably with that observed in high-extinction images, and polarizing rectifiers offer scarcely any advantage. Freed from the constraints of the light-limited conditions of DIC microscopy, video images can be recorded 60 times per second, or over 1,000 times the rate of photomicrographs at comparable magnifications under high-extinction conditions.Application of this method to the reticulopodial network of Allogromia has shown that cytoplasmic organelles are translocated only in contact with single microtubules or bundles of microtubules, and that these organelles fail to move when separated from microtubules. Microtubules themselves undergo both axial translatory (“sliding”) and lateral “zipping and unzipping” movements that have been suggested to occur during mitosis and other biological processes.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0886-1544
    Keywords: videomicroscopy ; polarization microscopy ; streaming ; reticulopodial motility ; Allogromia ; microtubules ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: A new method is described for recording rapid processes of cell motility in polarized light. The Allen video-enhanced contrast (AVEC-POL) method of polarization microscopy achieves significant improvements in resolution, contrast, and the visibility of fine detail by a combination of novel adjustments to a standard (unrectified) polarizing microscope and video camera. Using the full working aperture of a high-power planapochromatic objective lens and compensator setting of λ/9-λ/4, visible images appear lacking in contrast. However, the same images viewed with an appropriate video camera equipped with an electronic offset adjustment can be made to appear with as much contrast as desired, revealing a significantly greater amount of fine detail in the image than can be seen by high extinction visual microscopy alone. At bias retardations between one-ninth and one-quarter wave, the diffraction anomaly observed near extinction disappears. Consequently, polarizing rectifiers are not required with the AVEC-POL method, and images previously requiring photographic exposures of around 20 seconds are sufficiently bright to be registered on the video monitor in 1/60 second. Using an intensity monitor, quantitative measurements of cellular birefringence can be retrieved from live or videotaped images displaying a linear relationship between contrast and phase retardation due to birefringence. The AVEC-POL method also renders accessible to polarized light analysis a number of objects that scatter or depolarize too much light to be studied by high extinction methods. The method is demonstrated on model objects and applied to the highly motile reticulopodial network of Allogromia laticollaris. Rapid motion in close association with microtubules can now be analyzed in greater detail at a significant reduction in the cost of recording.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 363-370 
    ISSN: 0886-1544
    Keywords: Ca2+ ; Mg2+ ; symmetry ; flagella ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Potentially asymmetric spermatozoa are obtained when spermatozoa are demembranated in the presence of a low Ca2+/Mg2+ ion concentration ratio. They swim with asymmetric bending waves even when reactivated at low Ca2+ concentrations, and become more asymmetric when Ca2+ is increased. Potentially symmetric spermatozoa, which swim with symmetric bending waves at low Ca2+ and become asymmetric as the Ca2+ is increased, can be obtained by exposing the flagella to a high Ca2+/Mg2+ ratio, either during or subsequent to demembranation. The rate of this conversion is an increasing function of temperature and Triton concentration. Potentially symmetric spermatozoa can be reconverted to potential asymmetry, if the exposure to high Ca2+/Mg2+ is brief, and is terminated by addition of EGTA and Mg2+ before diluting the spermatozoa. The conversion to potential symmetry may involve removal of a labile component from the axoneme.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1981), S. 485-497 
    ISSN: 0886-1544
    Keywords: actin ; tubulin ; nucleotides ; polymerization ; microfilaments ; microtubules ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Both actin and tubulin, the major proteins of the cytoskeleton, bind nucleotide triphosphate (NTP) and exhibit the phenomenon of “polymerization-coupled” NTP hydrolysis. In this report I review the nature of polymerization-coupled NTP hydrolysis, and its possible role in the cellular function of actin and tubulin. Polymerization-coupled hydrolysis may be viewed as simply reflecting differences in the NTPase activity of free subunit as compared to polymer. Making assumptions concerning the values of various rate constants, it is possible to write expressions for the effects of NTP hydrolysis on the kinetics of polymerization. The role of NTP hydrolysis may be viewed in at least three different ways: (1) Hydrolysis alters the kinetics of assembly and disassembly. This leads to a consideration of the role of subunit flow in microtubule and microfilament function. (2) Hydrolysis is an essentially irreversible step that separates the assembly and disassembly reactions. This suggests a role of NTP in the regulation of polymer content during cellular cycles of assembly and disassembly. (3) NTP may allow transient stabilization of intersubunit bonds. This suggests a role of NTP in nucleation and possible regulation of nonequilibrium states of assembly.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 11-16 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SCOT column ; Coating, liquid phase ; Single-step coating ; Phenols ; Phenolic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A single-step coating method for the preparation of glass capillary SCOT columns is described. It is reproducible and less time-consuming than the well-known two-step coating procedures. Other methods attempted are discussed briefly. Both the flame ionization and electron capture detectors could be used in conjunction with temperature programming. The separations achieved with an “activity mixture”, phenols and phenolic acids, illustrate the resolution obtained. The columns are suitable for quantitative determinations and a comparison is made with a conventional packed column.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 38-39 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Activity ; Hydroxylated surfaces ; Dehydroxylated surfaces ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 411-412 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Chemical bonding - cross-linking ; Apolar columns ; Preparation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 523-524 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Split injection ; Injection time influence ; PAH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 533-534 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; End-sealing method for static coating ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 421-422 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Unstable flavor compound ; Comparison of fused silica, glass, and metal columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 49-53 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary ; Routine analysis of C1-C6 carboxylic acids ; Animal wastes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The C1 -C6 fatty acids present in various types of heterogeneous animal wastes were isolated by steam distillation and determined as benzyl esters by high resolution gas chromatography. Glass capillary columns, deactivated with barium carbonate and coated with UCON HB 5100, allowed the analysis of benzyl formate, acetate, propionate, isobutyrate, butyrate, isovalerate, valerate, and caproate in less than 20 minutes. Recovery tests, performed on more than 50 different samples, indicated a benzylation yield and an overall efficiency higher than 99%, with a standard deviation of 2.6% (C5) to 6.0% (C1). The absolute detection limit ranged from 0.3 picomole (caproic acid) to 1.0 picomole (formic acid).
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 495-499 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; Mass spectrometry ; Interface, direct coupling ; On-column injection ; Aflatoxin B1 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel fused silica capillary GC/MS direct coupling is described which ensures quantitative transfer of sample from the point of injection to the ion source of a mass spectrometer without contacting any surfaces other than the column wall. This device permits GC analysis of highly labile substances. Aflatoxin B1, previously considered unassayable by GC, can now be determined by GC/MS.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 164-168 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Simultaneous detection with effluent splitter ; Element-specific detection ; Petroleum residues ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two glass capillary gas chromatographic systems were equipped with inert effluent splitters which allowed simultaneous data acquisition using nonspecific and element-specific detectors. Simultaneous detection was achieved using the nonspecific flame ionization detector (FID) and the Hall® electrolytic conductivity detector (HECD) operated in either the sulfur-or the nitrogen-specific mode. Typical application of the simultaneous detection system as applied to analysis of petroleum residues is briefly described. The Hall electrolytic conductivity detector can be made element specific for halogen-, sulfur-, or nitrogen-containing compounds. Simultaneous detection enhances the information yield from a single sample injection and proves to be a powerful complementary technique when used with computerized gas chromatography/mass spectrometry.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 169-172 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Residue analysis ; Pirimiphos-methyl ; Malathion ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic method developed for the simultaneous determination of residues of pirimiphos-methyl (O-[2-(dimethyl-amino)-6-methyl-4-pyrimidinyl] O,O-dimethyl phosphorothioate) and malathion (diethyl mercaptosuccinate S-ester with O,O-dimethyl phosphorodithioate), in whole peanuts, peanut hulls, peanut meats, and peanut oil gives good recoveries and has a limit of detection for pirimiphos-methyl and malathion of 0.04 ppm. Quantitative analysis for the two insecticides with electronic integration was reliable to 0.1 ppm.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 295-296 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 257-259 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dihydro dimethyl ethers of vitamin K1 ; Separtion of diastereomers ; Characterization of source of vitamin K1 samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the gas-chromatographic determination of the diastereomers of vitamin K1 (phylloquinone) in the form of their dihydro dimethyl ethers. The reported method of derivatization and chromatographic analysis in conjunction with optical rotation measurements are useful approaches for characterization of vitamin K1 samples with respect to their origin.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 333-336 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Rapid analysis ; On-line analysis ; Low molecular weight hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rapid analysis is important for on-line chromatography. Gaseous or vaporized samples have been injected via heated gas sampling valves of less than 500 μl dead volume. The critical sampling and split problems could be solved by temperature programming. The general analysis described could be successfully used inter alia in scouting reactions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dynamic headspace analysis ; Solid waste ; Fused silica capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A dynamic headspace stripping technique for the extraction of volatile organic compounds has been applied to a variety of solid and semisolid waste materials. A simple glass apparatus accommodates a wide range of sample sizes and allows for the volatiles to be stripped at elevated temperatures. Concentration on Tenax, followed by thermal desorption and analysis by fused silica capillary gas chromatography provides detailed information on the volatile content of waste samples of widely differing matrix composition.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 527-529 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Thermodynamics ; Identification of analytes ; Olefins ; Squalane ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 612-615 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Porous layer open tubular fused silica columns ; Aluminum oxide ; C1-C5 hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the preparation of a Porous Layer Open Tubular (PLOT) fused silica column coated with submicron particles of aluminum oxide for the analysis of light hydrocarbons. The column is thermally stable and provides reproducible analytical data over a long period of time. The column can be operated at temperatures easily controlled by commercially available gas chromatographic apparatus. 1,3-Butadiene is retarded much more than its principal impurities: thus the polarity of aluminum oxide is extremely useful for butadiene analysis because none of the contaminants is obscured by the butadiene peak. The analysis of the 16 most common C1-C4 hydrocarbons is achieved within 5 min at 60°C with helium as the carrier gas. Conditioning of the carrier gas with water vapor from CuSO4.5H2O to decrease the activity of the aluminum oxide is described. Some applications of a 30 m × 0.32 mm aluminum oxide PLOT column are given.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 603-611 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Gas chromatograph/mass spectrometer/data system ; Dynamic headspace analysis ; Focused cryogenic trapping ; Pyrolysis ; Polymers ; Adhesives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Focused cryogenic trapping has been used to maximize the high resolution capabilities of fused silica capillary columns during dynamic headspace and pyrolytic polymer analyses. Mass spectrometric detection with data system recording/processing provide sensitive, selective, and rapid results. The techniques described herein demonstrate the power of both dynamic headspace and pyrolytic analyses for troubleshooting applications with complex industrial polymer products.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 188-190 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Helium ionization detector (HID) ; Vinyl chloride ; Sulfur gases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 346-347 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; WCOT-glass capillary ; Organophosphorus insecticides ; Pesticides ; Metabolites ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This article considers the separation of 23 organophosphorus insecticides to which two metabolites have been added. The high resolution of the column permits detection of the Z and E isomers of three of these insecticides.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 580-581 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Coal gasification tar ; Boiling point distribution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 215-217 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Direct method for flavor evaluation ; Aromatic herbs analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple, quick method is described for GC head space evaluation of herbs and drugs. The proposed procedure consists of milling a weighed sample of a certain herb in a glass device like a Braun MXK coffee grinder, modified in such a way that a special gas-tight valve allows the direct sampling of the vapors. Glass capillary columns are used to analyze the head space volatiles. Some preliminary applications of the method are given.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 232-232 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Sealing method ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 323-327 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Deactivation by colloidal aqueous silica plus BTPPC plus Carbowax 1000 ; Use for adsorption-sensitive solutes fails with basic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillary columns have been prepared without acidic additive in the stationary phase, from which free organic acids elute as sharp and symmetrical peaks. The required surface in the borosilicate glass capillary was generated by a combination of leaching with aqueous HCl and deposition of colloidal silica particles; it can be coated with stationary phases have a broad range of polarity. Aqueous samples containing free organic acids can also be analyzed in such columns in an isothermal mode.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 122-123 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica ; Capillary columns ; Deactivation ; Pyrocarbon ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 156-163 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Priority pollutants ; Volatile organics ; Extractable organics ; Pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Acrolein, acrylonitrile, volatile organics, base/neutral extractables, acid extractables, and pesticide fraction organics are analyzed in a single chromatographic run. This is accomplished by injecting the extractable organics, then applying a cryogenic focus to the front of the column, and desorbing the volatile components. The column utilized for this procedure is a fused silica open tubular (FSOT) column coated with the liquid phase SE-54. Minimum detection limits of this procedure by electron impact GC/MS are shown to be≤ 1 μg/liter in tests conducted on actual water samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 180-180 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Injector to column connection ; TCDD ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 186-187 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Effluent splitter, preparation of ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 578-579 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Crosslinked silicones ; Peroxide-initiated vulcanization ; Trifluoropylsilicone ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 583-584 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; 10% CuCl in stationary phase greatly improves resolution of high-boiling olefins (up to 190°C) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 641-643 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; On-column injection ; Discrimination ; Criteria given for precise sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Split injection ; Splitless injection ; Polynuclear aromatic hydrocarbons, quantitation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 203-208 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Split injection, vaporizing ; Glass wool as evaporation aid in split injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It has been reported that glass wool packed tightly into the glass liner of a vaporizing injector used in the splitting mode considerably reduces the standard deviation of the results obtained, because of improved evaporation of the sample prior to reaching the split point at the capillary column entrance. This finding could not be reproduced on using the same sample composition as reported in the literature, i.e. methanol/2-ethyl-1-hexanol (1:1).The standard deviations obtained were between 3 and 10% (depending on the conditions selected) and were not influenced significantly by the introduction of glass wool.The peak area ratio (methanol/2-ethyl-1-hexanol) was found to depend on a number of parameters, such as: injector temperature; glass liner internal diameter; syringe handling technique; the relative position of the syringe needle exit and capillary column entrance; the sample volume injected; and the packing of the glass liner. Generally, the area ratio deviated further from the correct one (determined by cold on-column sampling) when the glass liner was packed with glass wool.On the basis of the results, it is speculated that either a complete evaporation of the sample should be achieved (which appears to be impossible under the conditions we used) or, alternatively, the sample should be given the least possible opportunity to evaporate, thus allowing it to enter the column in the form of droplets. The results were worse in terms of precision and accuracy the greater the partition of sample components between the liquid (droplet) and vapor phase. It is concluded that the use of evaporation aids such as glass wool cannot be generally recommended.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 297-299 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Quantitative mulicomponent analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 647-648 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Direct injection of silicone fluids method of choice for determining trace organic contaminants ; ≥ 1 ppm toluene determined ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; On-column injection ; Triglycerides ; Separation according to degree of unsaturation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Triglycerides are separated according to their molecular weight and their degree of unsaturation on glass capillary columns by use of the on-column injection technique. The columns employed are silylated SE-30 columns of 4.5, 8, and 10m length with a film thickness of ca. 0.15 μm. The paper gives several examples of chromatograms of natural and hydrogenated triglycerides as well as of mixtures of pure, known triglycerides before and after interesterification.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 151-155 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; XAD-2 resin ; Fungicide residues, determination in wine and grape juice ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The fungicides Bupirimate, Fenarimol, and Vinclozolin were sprayed on Vines. The fruits were harvested 8 and 21 days after the final application and processed to juice and wine. The fungicide residues were determined by filtration of the samples throug XAD-2 after pH adjustment, elution with methylene chloride, and glass capillary gas chromatography with SE-30 as stationary phase. Residue values of the three compounds were reported before and after fermentation. The precision of the analytical method was established by spiking portuguese white wine and spanish grape juice with the three fungicides and Triadimefon. The recoveries were in the range 80%-100%, except for Vinclozolin.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 181-182 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Diatomaceous earth ; Deactivation ; Pyrocarbon ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 183-183 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; End-sealing technique for static coating ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 294-295 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; 2,3,7,8-TCDD ; Tetrachlorodibenzofurans ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 385-392 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Theory of band broadening ; Regression methods in column evaluation abt concept ; Possible aid in assessing coating efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the approach to the developement of a practical procedure for the evaluation of band broadening properties of gas capillary columns, the expression for the variance of a solute band is cast in a dimensionless form. This expression supplies the basis for a valid bench mark for column evaluation. Experimental results demonstrate the applicability of the method.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 406-408 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Effluent splitter, fused silica ; Efficient ; Inert ; Minimum dead volume ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 437-443 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Gas chromatographic profiles ; n-Butylboronates ; Alkyl-oximes ; Primary prostaglandins ; 6-Keto prostaglandin F1α ; Thromboxane B2 ; Isomers of prostaglandin F1α ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This work describes the use of glass capillary columns (GCC) in the rapid concurrent analysis of primary prostaglandins (PGs) (e. g. PGE2, PGE2, PGF2α) and other functionally significant metabolites of arachidonic acid (AA) such as TXB2 and 6-keto PGF1α. The use of a new multistep mixed derivatization approach that generates the methyl esters of n-butylboronate, pentafluorobenzyloxime, trimethylsilyl ether derivatives of these compounds remarkably simplifies the GC profiling of the three main pathways of AA metabolism (PGs, thromboxane, and prostacyclin). Furthermore, isomeric species giving very similar or identical mass spectral patterns can be easily identified by their relative retention times on high efficiency capillary columns.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 86-89 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed columns ; Multidimensional switching, MDSS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A multidimensional switching system with two packed columns has been used for the analysis of volatiles. Use of a high-boiling solvent and the backflush mode permitted total resolution of the mixture discussed in a short analysis time.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 102-108 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Series-coupled columns with different stationary phases ; Independent temperature control of columns ; Constant mass flow rate ; Retention time expressions ; Theory ; Selectivity control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The technique of controlling chromatographic selectivity by the adjustment of column temperatures in systems of series-coupled columns is investigated by means of a general model incorporating the effects of temperature and mobile phase compressibility. In a previous article the performance of series-coupled columns was investigated under conditions of constant overall pressure drop. The present paper, on the other hand, considers systems in which a constant mass flow rate is maintained at all temperatures. The expressions derived for the effective partition coefficient and the retention time are compared with those of the previous paper. The numerical results for two-column systems exhibit the same major trends as those for constant pressure drop. It is shown that the effective partition coefficient is slightly dependent on the mass flow rate.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 549-552 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Optically active stationary phase ; Amino acids, enantiomeric derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An enantiomeric mixture of amino acids is derivatized to give the respective N(O)-perfluoroacyl alkyl esters which can be resolved directly by gas chromatography on a Chirasil-Val capillary column. The retention times, resolution numbers, and elution order are reported.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 218-223 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Column preparation ; “Split” vs. “on-column” injection ; Amino acid analysis, quantitative 10 ng level ; Average relative standard deviation 1% ; Fish muscle protein analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A carefully Standardized technique is described for the preparation of glass capillary columns which can be used successfully for routine quantitative amino acid analysis. Comparison is made between two different modes of sample injection. Preliminary quantitative results from “split” injection and “on-column” injection techniques are evaluated statistically and it is concluded that the “on-column” system is a prerequisite for quantitative amino acid analysis by glass capillary gas chromatography. An analysis of fish muscle protein hydrolyzate illustrates an application of this technique and results are compared with those from a packed column analysis.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 184-185 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Alkene halohydrins ; Positional isomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of a fused silica capillary column for the gas chromatographic analysis of alkene halohydrin positional isomers is described. This method is illustrated with the complete resolution of the positional isomers for propylene bromohydrin, propylene iodohydrin, and allyl bromide bromohydrin. Comparison with the resolution obtained on a packed column is also provided.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 209-214 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Capillary GC/MS ; PAH, M.W. 300-402 ; Airborne particulate matter ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatography (GC), low-voltage mass spectrometry (LV MS), and gas chromatography/mass spectrometry (GC/MS) have been used for detecting polycyclic aromatic hydrocarbons (PAH) of molecular weight between 300 and 402 in airborne particulate matter. Nearly 200 high molecular PAH separated by fused silica capillary columns could be characterized by their El mass spectra. The lack of reference substances precluded further structure elucidation.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Cholesteric liquid crystal phase ; Film thickness and temperature study ; Separation of geometrical isomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Improved separations of the isomers of olefinic aliphatic insect pheromones were obtained on cholesteryl cinnamate glass capillary columns by operating in the supercooled temperature range of the liquid crystal. Capillary columns were prepared with varying film thickness of the stationary phase; choice of the correct film thickness ensured optimum retention for a wide range of compounds within the most effective temperature range of the liquid crystal. The deactivation procedures described made the liquid crystal columns suitable for separation of the geometric isomers of polar and nonpolar compounds.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 348-350 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Use for thermolabile, nonderivatized N-methylcarbamates tested ; Faster, better separation, higher sensitivity than with HPLC methods ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 409-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Micro-HPLC ; Capillary columns, preparation ; Optical monitor ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 433-436 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Persilylation ; Polar phases ; Ammonia etching ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Static ammonia etching has been used to effect regular surface roughening of glass capillaries. Following such treatment, polar phases could be coated after persilylation with varioussilylation agents such as hexamethyl-, tetramethyldiphenyl-, and tetra- phenyldimethyldisilazane, respectively. This method produces columns of high thermostability, which is limited only by the maximum applicable temperature for the phase itself.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 525-526 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Mass spectrometry ; Reactions of organomercurials interpreted ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 553-556 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Carbohydrate enantiomer separation ; New chiral stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New chiral polymers have been prepared by conversion of cyano groups of polysiloxanes XE-60 and OV-225 into carboxylic groups and subsequent coupling to give the respective S-valine-R-α-phenyl-ethyl amide. In contrast to the corresponding stationary phases with S-α-phenylethyl amide groups, which have been used for the resoultion of trifluoroacetylated hexose derivatives, the new phase show high enantioselectivity for pentose and 6-deoxyhexose derivatives.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 644-646 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Wide-bore capillary columns ; On-column injector ; Prevention of sample discrimination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 393-397 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Simultaneous detection ; Splitting capillary effluent ; Detection limit of 1 ppm Archlor 1254 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A state-of-the-art gas chromatographic system for automatic simultaneous detection of halogenated and normal hydrocarbons has been developed, which consists of a standard Hewlett-Packard 5880 with a fused silica capillary column, whose effluent is split between the standard flame ionization detector and a Tracor Hall electroconductivity detector. The system provedes excellent capillary chromatography results and high sensitivity for halogenated compounds (a detection limit of 1 ppm Archlor 1254 in fuel oil). Reliability has been provides in the daily analysis of complex environmental samples.Emergency response cleanup and the containment of hazardous chemical spills and chemical dump sites forces one to deal with samples that are very complex. The contain large numbers of naturally occurring organic compounds and varying types of organic pollutants. Capillary chromatographic techniques of gas chromatographic and gas chromatographic/mass spectrometric analyses are necessary to achieve the resolution required for the analysis of these samples.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...