Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Anterior cruciate ligament  (1)
  • Antigen-elimination  (1)
  • Atlantoaxial screw fixation  (1)
  • Cementless  (1)
Material
Years
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 4 (1994), S. 143-148 
    ISSN: 1432-1068
    Keywords: Ligament croisé antérieur ; Résultats cliniques ; Contrôle de qualité ; Mesure instrumentale de la laxité ; Evaluation isocinétique de la fonction musculaire ; Anterior cruciate ligament ; Clinical scores ; Quality control ; Instrumented laxity testing ; Isokinetic muscle force
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary An objective functional evaluation after acute repair of unilateral anterior cruciate ligament (ACL) rupture was performed in a homogeneous group of 37 patients at a mean of 44.4 months after trauma. A patient questionnaire, standardized clinical testing, instrumented laxity testing and concentric isokinetic muscle torque evaluation were included. Instrumented laxity testing proved to be closely correlated with the pivot shift test (r=0.54, p〈0.001) and the Lachman test (r=0.73, p〈0.001), but offered a far better resolution. The degree of anterior instability as measured could be shown to correlate negatively with the isokinetic flexor muscle torque (r=−0.61, p〈0.001) and the hamstring/quadriceps ratio (r=−0.44, p〈0.05). The intraindividual differences of instrumented laxity testing revealed that a significant degree of instability (〉2 mm) was present in 49% of the patients contrasting with the good result in the Lysholm score (mean=84.5 pts.) and a 74% rate of satisfied patients. Instrumented laxity testing makes a significant contribution to objective evaluation of functional results after ACL repair.
    Notes: Résumé Une évaluation fonctionnelle objective a été effectuée après réparation unilatérale de rupture du ligament croisé antéro-externe (LCAE) dans une série homogène de 37 patients, avec un recul moyen de 44,4 mois par rapport au traumatisme. Un questionnaire, un contrôle clinique standardisé, des tests instrumentaux de laxité ligamentaire ainsi qu'une évaluation du moment de torsion musculaire isokinétique concentrique furent utilisés. Le contrôle instrumental de la laxité ligamentaire peut être considéré comme très proche du test d'instabilité du pivot (r = 0,54, p 〈 0,001) et le signe de Lachman (r = 0,73, p 〈 0,001) mais est plus rapidement décisif. Le degré d'instabilité antérieure mesuré pourrait être considéré comme corrélé négativement avec le moment de torsion musculaire isokinétique concentrique (r = 0,61, p 〈 0,001) et le rapport ischio-jambiers/quadriceps (r = 0,44, p 〈 0,005). Les différences entre les sujets des tests instrumentaux de laxité ligamentaire révèlèrent qu'un degré significatif d'instabilité (〉 2 mm) existait chez 49 % des patients, ce qui contraste avec les bons résultats au score de Lysholm (moyenne : 84,5 points) et une proportion de 74 % de patients satisfaits. Ainsi le test instrumental de laxité ligamentaire apporte-t-il une contribution importante à l'évaluation fonctionnelle post-opératoire des ligamentoplasties du LCAE.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1068
    Keywords: Modular femoral prosthesis ; Fretting ; Taper socket ; Cementless
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Les auteurs décrivent une nouvelle prothèse fémorale modulaire associant une prothèse conventionnelle et un clou centro-médullaire. La prothèse est constituée d’une pièce céphalique et d’une partie diaphysaire fixées ensemble par un cône morse. Chaque pièce est modulaire selon les besoins en longueur et en diamètre. L’antéversion de la pièce céphalique est libre. Les pièces diaphysaires ont une courbure sagittale anatomique et sont creuses, permettant l’utilisation d’un guide centro-médullaire. Les pièces diaphysaires longues peuvent être verrouillées. Les pièces céphalique et diaphysaire sont en alliage de titane et la pièce diaphysaire a une surface grenaillée dans sa partie proximale. Le cône morse a été optimisé par l’adjonction d’une rainure qui a diminué l’usure par abrasion lors des tests de fatigue. Aucun démontage de la jonction intraprothétique et aucune fracture dé tige n’a été rencontrée lors de c es tests. La technique opératoire n’offre aucune particularité. Cent vingtquatre prothèses ont été implantées depuis 1990, principalement pour des fractures du col fémoral et des changements de prothèses totales de hanche. Les résultats cliniques sont en cours d’investigation. D’autres indications plus rares ont été choisies : pseudarthrose per-trochantérienne, fracture sur coxarthrose, chirurgie métastatique. Cette prothèse permet un ancrage diaphysaire stable dans les pertes de substance de l’extrémité supérieure du fémur, et autorise ainsi la repousse osseuse dans cette zone, spontanée ou après greffe osseuse, et la fixation proximale secondaire. L’optimisation du cône morse a permis de diminuer de façon considérable l’usure par abrasion. La modularité de la prothèse permet de s’adapter à toutes les morphologies et toutes les situations cliniques.
    Notes: Summary The development and clinical indications of a new modular femoral endoprosthesis consisting of a head and shaft component is discribed. Components are available in different lengths and diameters and therefore can be joined individually depending on the patients anatomy and surgery required. Both parts are joined by a unique optimized taper socket with a groove, avoiding fretting and corosion. Fatigue tests showed no loosening of the tapered connection and no prosthesis fracture. The advantage of this new modular prosthesis is diaphyseal stabilization, if necessairy by two distal interlocking screwes. Indications are revisions, pertrochanteric femoral and neoplastic fractures if cementless bridging of boney defects in the calcar region must be achieved. Further indications are femoral neck fraktures and coxarthrosis if stable diaphyseal fixation is required. The material and surface structure as well as the philosophie of the distal fixation are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0932
    Keywords: Metastasis of the cervical spine ; C2 instability ; Posterior fixation ; Atlantoaxial screw fixation ; Hook plate fixation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new technique for the stabilization of metastatic cervical instability of the axis and/or neighboring vertebrae at lower levels is described. By a combination of the transarticular screw fixation C1/2 (Magerl) with the hook plate technique (Magerl) (or facultatively with a 1/3 tubular or 3.5 mm dynamic compression plate) from a posterior approach, the risks and stresses on the patient of a transoral or a combined extended technique are avoided, creating a proven biomechanically stable situation. The new technique is particularly helpful in those patients with a rapid progression of their malignant disease in whom local tumor growth is not expected to compress the spinal cord, and palliative stabilization of the unstable upper cervical spine can avoid neurological deficits or alleviate pain syndromes at a minimized morbidity due to surgery. The new technique has been successfully applied in a limited clinical series of four patients with metastasis of the cervical spine, resulting in substantial improvement of the general condition and cervical pain syndrome and stability of the assemblage during the observation period (4–9 months).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Clinical and experimental medicine 156 (1971), S. 157-170 
    ISSN: 1591-9528
    Keywords: Antigen-elimination ; Passive hemagglutination ; Ouchterlony's test ; Immunelectrophoresis ; Dog ; Antigenelimination ; Passive Hämagglutination ; Ouchterlony-Test ; Immunelektrophorese ; Hund
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Nach wiederholter i. v. Verabreichung von ultrazentrifugiertem P-IgG in einer Dosis von 8 mg/kg KG wurde bei erwachsenen Hunden in 65% eine Immuntoleranz mit Hilfe des Antigeneliminationstestes beobachtet. Die gleichzeitig durchgeführte passive Hämagglutination führt zu völlig gleichen Ergebnissen. Ein Vergleich der Antigenelimination mit dem Agargeldoppeldiffusionstest bzw. der Immunelektrophorese zeigt jedoch, daß nur in 15% einer beschleunigten Antigenelimination ein positiver Nachweis von präcipitierenden Antikörpern gelingt. Weiterhin wurden in keinem Fall einer Nichtimmunelimination Präcipitationslinien gegen P-IgG gefunden. Prüft man die Immunantwort mit der Antigeneliminationstechnik bei P-IgG-toleranten Hunden, denen passiv allogene gegen P-IgG gerichtete Antikörper zugeführt worden sind, so kann man nur in einem Drittel der Tiere eine beschleunigte Elimination des Testantigens feststellen, die sich nach 4 Wochen wieder in die ursprüngliche Form einer Nichtimmunelimination umwandelt. Einen Hinweis auf den Verbleib des radioaktiv markierten Testantigens während einer Immun- bzw. einer Nichtimmunantwort liefert die Bestimmung der Organaktivität während der Testperiode. Ein signifikanter Anstieg der Radioaktivität in Lymphknoten, Leber, Milz, Lunge und Niere ab dem 4. Tag ist charakteristisch für die Antigenelimination vom Immuntyp. Die Ergebnisse zeigen, daß die Antigenelimination mindestens ein ebenso empfindlicher Test ist wie die passive Hämagglutination und daß die Spezifität mit der des Ouchterlony bzw. der Immunelektrophorese vergleichbar ist. Da in diesem Test einmal hohe Spezifität mit hoher Empfindlichkeit vereint ist und darüber hinaus die Aussagekraft dieses in vivo-Testes immer der Aussage eines in vitro Testes überlegen ist, sollte man die Immunantwort eines Organismus mit der Antigenelimination prüfen.
    Notes: Summary After repeated i. v. applications of 8 mg/kg b. w. ultracentrifuged horse-IgG a specific immunological tolerance was observed in 65% of the treated dogs by means of the antigen-elimination technique. Corresponding results were obtained with the simultaneously performed passive hemagglutination test. A comparison of the antigen-elimination with Ouchterlony's test and the immunelectrophoresis, however, shows that precipitating antibodies can be found only in 15% of an accelerated immune-elimination. Lines of precipitated antibodies (H-IgG) could not be detected during a non-immune elimination. Examining the immune-response in H-IgG-tolerant dogs after the i. v. infusion of allogenous antibodies against H-IgG with the antigen-elimination technique only one third of the animals showed on accelerated elimination of the testantigen, which changed to the original type of a non-immune elimination within 4 weeks. The determination of the radioactivity in various organs of the animals during the testperiod gives a hint to the fate of the radioactive testantigen. A significant increase of the radioactivity in the lymphnode, liver, spleen, lung and kidney from day 4 of the antigen-elimination is characteristic of an accelerated immune-elimination. The results give the evidence that the elimination of an antigen is just as a sensitive test as the passive hemagglutination. The specificity is comparable with that of Ouchterlony's test or the immunelectrophoresis. Since the technique combines high sensitivity with high specificity the result of thisin vivo test is more reliable than that of anin vitro testmethod. The antigen elimination should always be performed to investigate the immune-response of organisms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...