Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The soft x-ray continuum radiation in tokamak fusion test reactor (TFTR) low-density neutral-beam discharges can be much lower than its theoretical value obtained by assuming a corona equilibrium. This reduced continuum radiation is caused by an ionization equilibrium shift toward lower states, which strongly changes the value of the average recombination coefficient of metallic impurities γ¯, even for only slight changes in the average charge Z¯. The primary agent for this shift is the charge exchange between the highly ionized impurity ions and the neutral hydrogen, rather than impurity transport, because the central density of the neutral hydrogen is strongly enhanced at lower plasma densities with intense beam injection. In the extreme case of low-density, high neutral-beam power TFTR operation (energetic ion mode) the reduction in γ¯ can be as much as one-half to two-thirds. We calculate the parametric dependence of γ¯ and Z¯ for Ti, Cr, Fe, and Ni impurities on neutral density (equivalent to beam power), electron temperature, and electron density. These values are obtained by using either a one-dimensional impurity transport code or a zero-dimensional code with a finite particle confinement time. As an example, we show the variation of γ¯ and Z¯ in different TFTR discharges.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The effect of isotope on confinement in high-recycling, L-mode plasmas is studied on the Tokamak Fusion Test Reactor (TFTR) [see D. M. Meade, J. Fusion Energy 7, 107 (1988)] by comparing hydrogen and deuterium plasmas with the same magnetic field and similar electron densities and heating power, with both Ohmic and deuterium-neutral-beam heating. Following a long operational period in deuterium, nominally hydrogen plasmas were created through hydrogen glow discharge and hydrogen gas puffing in Ohmic plasmas, which saturated the exposed limiter surface with hydrogen and raised the H/(H+D) ratio from 10±3% to 65±5%. Ohmic deuterium discharges obtained higher stored energy and lower loop voltage than hydrogen discharges with similar limiter conditions. Neutral-beam power scans were conducted in L-mode plasmas at minor radii of 50 and 80 cm, with plasma currents of 0.7 and 1.4 MA. To minimize transport differences from the beam deposition profile and beam heating, deuterium neutral beams were used to heat the plasmas of both isotopes. Total stored energy increased approximately 20% from nominally hydrogen plasmas to deuterium plasmas during auxiliary heating. Of this increase about half can be attributed to purely classical differences in the energy content of unthermalized beam ions. Kinetic measurements indicate a consistent but small increase in central electron temperature and total stored electron energy in deuterium relative to hydrogen plasmas, but no change in total ion stored energy. No significant differences in particle transport, momentum transport, and sawtooth behavior are observed. Overall, only a small improvement (∼10%) in global energy confinement time of the thermal plasma is seen between operation in hydrogen and deuterium. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Steady-state and perturbative transport analysis are complementary techniques for the study of transport in tokamaks. These techniques are applied to the investigation of auxiliary-heated L-mode and supershot plasmas in the tokamak fusion test reactor (TFTR) [R. J. Hawryluk et al., Plasma Physics and Controlled Nuclear Fusion Research, Proceedings of the 11th International Conference, Kyoto, 1986 (IAEA, Vienna, 1987), Vol. 1, p. 51.]. In the L mode, both steady-state and perturbative transport measurements reveal a strong temperature dependence that is consistent with electrostatic microinstability theory and the degradation of confinement with neutral beam power. Steady-state analysis of the ion heat and momentum balance in supershots indicates a reduction and a significant weakening of the power-law dependence on the transport in the center of the discharge.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Results from helium, iron, and electron transport studies on the Tokamak Fusion Test Reactor (TFTR) [Plasma Phys. Controlled Nucl. Fusion Res. 26, 11 (1984)] in L-mode and supershot deuterium plasmas with the same toroidal field, plasma current, and neutral beam heating power are presented. They are compared to results from thermal transport analysis based on power balance. Particle diffusivities and thermal conductivities are radially hollow and larger than neoclassical values, except possibly near the magnetic axis. The ion channel dominates over the electron channel in both particle and thermal diffusion. A peaked helium profile, supported by inward convection that is stronger than predicted by neoclassical theory, is measured in the supershot. The helium profile shape is consistent with predictions from quasilinear electrostatic drift-wave theory. While the perturbative particle diffusion coefficients of all three species are similar in the supershot, differences are found in the L mode. Quasilinear theory calculations of the ratios of impurity diffusivities are in good accord with measurements. Theory estimates indicate that the ion heat flux should be larger than the electron heat flux, consistent with power balance analysis. However, theoretical values of the ratio of the ion to electron heat flux can be more than a factor of 3 larger than experimental values. A correlation between helium diffusion and ion thermal transport is observed and has favorable implications for sustained ignition of a tokamak fusion reactor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: General plasma physics principles state that power flow Q(r) through a magnetic surface in a tokamak should scale as Q(r)= {32π2Rr3Te2c nea/[eB (a2−r2)2]} F(ρ*,β,ν*,r/a,q,s,r/R,...) where the arguments of F are local, nondimensional plasma parameters and nondimensional gradients. This paper reports an experimental determination of how F varies with normalized gyroradius ρ*≡(2TeMi)1/2c/eBa and collisionality ν*≡(R/r)3/2qRνe(me/ 2Te)1/2 for discharges prepared so that other nondimensional parameters remain close to constant. Tokamak Fusion Test Reactor (TFTR) [D. M. Meade et al., in Plasma Physics and Controlled Nuclear Fusion Research, 1990, Proceedings of the 13th International Conference, Washington (International Atomic Energy Agency, Vienna, 1991), Vol. 1, p. 9] L-mode data show F to be independent of ρ* and numerically small, corresponding to Bohm scaling with a small multiplicative constant. By contrast, most theories predict gyro-Bohm scaling: F∝ρ*. Bohm scaling implies that the largest scale size for microinstability turbulence depends on machine size. Analysis of a collisionality scan finds Bohm-normalized power flow to be independent of collisionality. Implications for future theory, experiment, and reactor extrapolations are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2043-2045 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Two improvements to the SPRED multichannel VUV spectrographs used on the TFTR and PBX tokamaks have been made: (1) a new 2100-g/mm grating covering the 100–320-A(ring) region with 0.4-A(ring) resolution (FWHM) has been added to the existing 450-g/mm grating (100–1100 A(ring) with 2-A(ring) resolution), and (2) the TFTR SPRED has been absolutely calibrated using synchrotron radiation from the NBS SURF II facility, while the PBX system has been calibrated using conventional branching ratios along with line ratios from charge-exchange-recombination excited lines. The availability of high-resolution spectra in the 100–320-A(ring) range provides improved measurements of metallic ion emissions and, when the instrument views across a neutral beam as in PBX, allows carbon and oxygen densities to be measured via charge-exchange-recombination spectroscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2151-2153 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Metal impurity concentrations are measured by the pulse-height-analyzer (PHA) diagnostic from Kα x-ray peak intensities by use of an averaged excitation rate 〈σv〉. Low-Z impurity concentrations are inferred from the continuum enhancement (relative to a pure plasma) minus the enhancement due to metals. Since the PHA does not resolve lines from different charge states, 〈σv〉 is a weighted sum of rates; coronal equilibrium is usually assumed. The 〈σv〉 used earlier omitted the intercombination and forbidden lines from the dominant heliumlike state. The result was an overestimate of metals and an underestimate of low-Z impurities in cases where metals were significant. Improved values of 〈σv〉 using recent calculations for H-, He-, and Li-like Fe range from 10% to 50% larger than the earlier rates and yield metal concentrations in better agreement with those from vacuum ultraviolet (VUV) spectroscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Experience with the α charge exchange recombination spectroscopy and pellet charge exchange confined, nonthermal alpha particle diagnostics over the first two years of Tokamak test fusion reactor (TFTR) D–T operation is summarized. A brief summary of the concept, instrumentation, and analysis techniques for each diagnostic is given, followed by examples of alpha physics results. Issues important to further development of these diagnostic techniques for TFTR and ITER are discussed. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 1014-1020 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A high throughput, shielded, multichannel, extreme ultraviolet (XUV) spectrograph to be used for plasma diagnostics was built. The instrument uses seven hollow fibers to transport the radiation by multiple grazing incidence reflections from the tokamak port through the instrument's shield to the spectrometer entrance slit. In this way, the ratio of background radiation streaming through the entrance slit to XUV flux is reduced by a factor of at least 2500. The seven hollow fibers provide seven channels corresponding to seven different lines of sight through the plasma. The spectrograph uses a toroidal mirror together with a plane, aberration-corrected grating to disperse radiation in the 50–200 A(ring) region. Up to seven spectra are recorded simultaneously, at rates of 30–90 Hz, using a microchannel plate assembly optically coupled to a charge-coupled device camera. This will permit, during a single discharge, measurement of spatial emissivity profiles from various ionization states of an injected impurity, providing a better understanding of their time evolution and valuable information on cross-field ion transport.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A two-dimensional intensified photodiode array is used to measure charge exchange recombination emission in the TFTR. The noise of this detector has been characterized to provide a better estimation of the error bars associated with ion temperature measurements. Contributions to the measured signal include a dc level offset, an integrated dark signal, and the actual photon signal. In addition to photon noise, there is a significant readout noise. The analysis was complicated by a nonlinear response of the readout circuitry. The detector output is linearized and the pixel-to-pixel gain variation is removed with a white field correction. The noise has been modeled over a range of integration times of the detector and gains of the intensifier, allowing an estimation of the uncertainty in the measurement at each pixel, and therefore its appropriate weight in the fitting function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...