Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (17)
  • 1985-1989  (17)
Material
  • Electronic Resource  (17)
Years
Year
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The bunch length was measured by using a highly sensitive streak camera with a time resolution of 2 ps. It was found that fine structures appeared in the electron bunch shape and that the shapes of electron bunches were described by a Gaussian distribution on the average. The dependence of bunch length on beam current was measured for an electron beam of 607 MeV. The bunch length was well represented by a power function of beam current with an exponent of 0.197 at currents lower than 35 mA or 0.30 at high currents. The experimental results suggest that the longitudinal coupled-bunch beam instability takes place at low beam currents and the turbulent instability dominates at high currents. It was also found from the three-dimensional bunch shape measurements that the bunch shape tended to blow up at high currents.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cutaneous pathology 13 (1986), S. 0 
    ISSN: 1600-0560
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Calcinosis universalis associated with dermatomyositis occurred in a 58-year-old woman. Tissues removed from the sublingual region in the patient were studied by ordinary microscopy, electron microscopy, and an electron-microanalytic method. The calcified materials were distributed on collagen fibers and seemed to have a relationship with foci of fibrinoid degeneration. Moreover, globular and/or membranous structures, considered to originate from the degenerate cells of the stroma, were observed in these calcified zones. Some of them contained electron-dense materials. Therefore, the globular and/or membranous structures were thought to be concerned with initial calcification in this case. Furthermore, irregular bone tissue was formed adjacent to the calcified masses. In addition, the calcified materials were identified by X-ray diffraction examination and electron microscopy as hydroxyapatite.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0630
    Keywords: 73.40.Qv ; 73.60.Fw ; 86.60.Pg
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract One of the disadvantages of applying an a-Si:H thin-film transistor (TFT) to an active matrix-addressed liquid crystal (LC) panel is that a TFT with an a-Si:H has a very large photo-leakage current because of the high photo-conductivity of an a-Si:H itself. We have tried decreasing the photo-leakage current by varying the thickness of an a-Si:H layer (L) in TFTs and investigated the characteristics of TFTs, mainly drain voltage versus drain current containing photo-leakage current (I ph). As a result, it is shown that lnI ph is proportional to InL, and its gradient is 1.5–2.0. We assume that the thinner an a-Si:H layer is, the more effective the recombination of carriers at the interface states is forI ph. We have applied TFT with a very thin a-Si:H layer (∼30nm) to a full-color active matrix-addressed LC panel for a moving picture display and realized a display of good quality under illuminated condition of 5×104lx without a shading layer in it.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 6 (1987), S. 413-414 
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Austenitic (fcc) Fe-Mn-Al alloys were nitrided in the temperature range 723 to 973 K by a glow discharge method using H2-N2 gas mixtures, and the microstructures and compositions of the nitrided layers were investigated in detail. A thin surface layer and a thick nitrogen-diffused layer (internal nitrided layer) were produced; the former consisted of both manganese nitrides and a ferritic (bec) phase, while the internal nitrided layer had an austenitic structure with the incorporated excess nitrogen atoms. X-ray photoelectron spectra revealed that the incorporated nitrogen atoms have a strong interaction with aluminium lattice atoms. By nitriding, hardness values of the Fe-Mn-Al alloys were increased fromH v = 350 to ca. 1000, and the corrosion resistance to sulphuric acid solution was enhanced by a factor of 30. These improvements are associated with a uniform distribution of the incorporated nitrogen and also with the presence of nitride-like interactions between the nitrogen and aluminium atoms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-4803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Preparation and electrical characterization of undoped indium oxide films were examined as a function of thickness and annealing. Thin films ranging from 1.1 to 113 nm thickness were deposited on glass substrates by ion-beam sputtering. Low-angle X-ray diffraction analysis in multi-layered films showed the possibility that physically continuous and almost flat films were formed even in the thinnest 1.1 nm films. Room temperature resistivity of as-deposited films decreased sharply by more than five orders of magnitude as the thickness increased from 1.1 to 5.2 nm. The 2.4 nm thick films, in its as-deposited state, showed a gradual resistivity modulation with the change of atmosphere between air and argon gas at room temperature. Annealing at 300° C for 5 h in air increased the resistivity drastically; the room temperature resistivity of 24.3 nm thick films changed from 2.2×10−3 Ω cm (as-deposited) to higher than ∼ 105 Ω cm (annealed).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 245 (1988), S. 170-174 
    ISSN: 1434-4726
    Keywords: Ménière's disease ; Isosorbide ; Intratympanic gentamycin therapy ; Tubal catheter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In 1974, six patients with incapacitating unilateral Ménière's disease were given an empiric treatment with intratympanic gentamycin sulfate via the eustachian tube using a tubal catheter with a small side-branch. These patients then showed excellent results with relief from vertigo over a 13-year period. Since 1980, we have treated patients suffering from Ménière's disease with isosorbide. When patients could not be controlled with this therapy, isosorbide was given in addition to intratympanic gentamycin therapy using a tubal catheter. Of 75 patients with Ménière's disease who received gentamycin and isosorbide therapy, 41 patients could be evaluated by the classification for Ménière's disease proposed by the American Academy of Opthalmology and Otolaryngology (AAOO). Subsequent results showed that vertigo improved in 73% of the patients. According to the AAOO classification, 11 patients (27%) were group A, 16 patients (39%) were group B, and 4 patients (10%) were group C. Eleven patients were group D (27%) and experienced persistent vertigo despite treatment. Our experiences show that patients with severe Ménière's disease can be readily treated with intratympanic gentamycin therapy using a tubal catheter, even on an outpatient basis. This treatment is also a most effective treatment, as it allows the effects of isosorbide to be obtained with smaller doses of gentamycin sulfate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1434-601X
    Keywords: 23.40.Bw
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The average polarization of the nucleus12B (bound state) produced in the polarized-muon capture reaction12C(μ −,v μ )12B was measured by the muon spin resonance method in a pulsed muon beam. The polarization of12B was maintained completely under a magnetic field of 3 kG in a Grafoil target. After the observed result was corrected for the contribution from the excited states of12B, Pav (ground state) was deduced to be 0.462±0.053. This result yieldsg P /g A =10.1 −2.6 +2.4 , which is almost consistent with the PCAC prediction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of materials science 4 (1985), S. 1425-1426 
    ISSN: 1573-4811
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...