Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2005-2009  (7)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of the European Academy of Dermatology and Venereology 19 (2005), S. 0 
    ISSN: 1468-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background  The 1- and the 2-euro coins consist of nickel alloys, which release nickel. The nickel released by far exceeds the amount allowed by the European Union Nickel Directive referring to products intended to come into direct and prolonged contact with the skin. As there is only temporary contact with the skin, the clinical relevance of nickel-containing coins with regard to nickel dermatitis is a matter of debate, although there is evidence that the nickel released from the coins affects some nickel-sensitive subjects through occupational exposure.Objectives  Our aim was to study skin reactivity to euro coins, and to correlate the frequency and intensity of coin patch test responses to sensitization thresholds to nickel.Patients and methods  Sixty-four nickel-sensitized and 30 non-nickel-sensitized subjects were patch tested with serial dilutions of nickel sulfate (5, 1, 0.5, 0.1, 0.05, 0.01 and 0.005% in distilled water) and with coins. Italian coins (500, 200, 100 and 50 lira) and euro coins (2 and 1 euros, 20 and 5 euro cents) were used for patch testing and compared.Results  The application of 1- and 2-euro coins to the skin induced eczematous reactions, being more frequent and intense in comparison with those provoked by other coins. A correlation between intensity of responses to coin patch tests and sensitization threshold to nickel was observed. Patients with the strongest reactions to 1- and 2-euro coins showed positive responses to the lowest nickel concentrations.Conclusions  The nickel content in euro coins represents a possible health hazard, especially for highly nickel-sensitive subjects. We recommend that nickel sulfate patch tests should be performed at different concentrations to determine sensitization thresholds at least in individuals with occupational exposure to coins.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of the European Academy of Dermatology and Venereology 19 (2005), S. 0 
    ISSN: 1468-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The diagnosis of atopic dermatitis (AD) is made using evaluated clinical criteria. Management of AD must consider the symptomatic variability of the disease. It is based on hydrating topical treatment, and avoidance of specific and unspecific provocation factors. Anti-inflammatory treatment is used for exacerbation management. Topical corticosteroids remain the first choice. Systemic anti-inflammatory treatment should be kept to a minimum, but may be necessary in rare refractory cases. The new topical calcineurin inhibitors (tacrolimus and pimecrolimus) expand the available choices of topical anti-inflammatory treatment. Microbial colonization and superinfection (e.g. with Staphylococcus aureus, Malassezia furfur) can have a role in disease exacerbation and can justify the use of antimicrobials in addition to the anti-inflammatory treatment. Evidence for the efficacy of systemic antihistamines in relieving pruritus is still insufficient, but some patients seem to benefit. Adjuvant therapy includes ultraviolet (UV) irradiation preferably of UVA wavelength; UVB 311 nm has also been used successfully. Dietary recommendations should be specific and only given in diagnosed individual food allergy. Stress-induced exacerbations may make psychosomatic counselling recommendable. ‘Eczema school’ educational programmes have proved to be helpful.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Contact allergy to and allergic contact dermatitis from methyldibromo glutaronitrile (MDBGN) have frequently been reported. As there has been no agreement on which MDBGN test preparation to use, a study was initiated to help determine the optimal patch test preparation for MDBGN. 2661 consecutively patch tested patients at 11 test clinics representing 9 European countries participated. Petrolatum preparations with MDBGN at 1.0%, 0.5%, 0.3% and 0.1% were inserted in the standard series. Contact allergy rates were noted in the range 4.4–1.1% following decreasing test concentrations. Reactions not fulfilling all criteria to be classified as allergic reactions could represent either weak allergic or irritant reactions, and such reactions were noted in the range 8.2–0.5% with decreasing concentrations. A significant number of these reactions represented weak allergic reactions, as allergic reactions were obtained to higher patch test concentrations in the same individual. Morphologically irritant reactions were noted only for the highest test concentrations. In summary, the contact allergy rates and frequencies of doubtful and irritant reactions vary with the patch test concentration. The final decision on patch test concentration for MDBGN should not only rely on these factors but also include information on patch test concentrations required to diagnose individual cases with allergic contact dermatitis from MDBGN as well as results of repeated open application tests.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1600-0536
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Contact allergy to and allergic contact dermatitis from methyldibromo glutaronitrile (MDBGN) have frequently been reported. This study was initiated to help determine the optimal patch test preparation for MDBGN. In 51 patients with a doubtful or a positive patch test reaction to at least 1 of 4 test preparations with MDBGN in petrolatum at 1.0% w/w, 0.5%, 0.3% and 0.1%, a repeated open application test (ROAT) with moisturizers with and without MDBGN at 0.03% w/w was performed on the upper arms for 2 weeks. 18 of the 51 (35.3%) patients developed a positive ROAT. In all patients, there was a positive ROAT only to the moisturizer with MDBGN (P 〈 0.001). A statistically significant association was also found between the patch test reactivity (PTRL) and the outcome of the ROAT (P 〈 0.001). If only considering those with a PTRL above 0.3%, thus with negative or doubtful test reactions to 0.1% and 0.3%, there were still statistically significantly more patients with a positive ROAT to the moisturizer with MDBGN than to the moisturizer without MDBGN. The study demonstrates that patch testing with MDBGN at 0.3% and 0.1% will miss clinically relevant patch test reactions to MDBGN.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The Muir–Torre syndrome (MTS) is an autosomal dominant genodermatosis characterized by the presence of sebaceous gland tumours, with or without keratoacanthomas, associated with visceral malignancies. We describe and characterize two families in which the ample phenotypic variability of MTS was evident. After clinical evaluation, the skin and visceral tumours of one member of a family with ‘classic’ MTS and one member of a family with a ‘peculiar’ MTS phenotype without sebaceous lesions, but with only multiple keratoacanthomas, were analysed for microsatellite instability (MSI) and by immunohistochemistry. Tumours of both individuals showed MSI, with a concomitant lack of MSH2 immunostaining in all evaluated skin and visceral lesions; moreover, in the proband of family 2 a constitutional mutation (C→T substitution leading to a stop codon) in the MSH2 gene was identified. We conclude that the diagnosis of MTS, which is mainly clinical, should take into account an ample phenotypic variability, which includes both cases with typical cancer aggregation in families and cases characterized by the association of visceral malignancies with multiple keratoacanthomas (without sebaceous lesions), without an apparent family history of cancer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Skin research and technology 11 (2005), S. 0 
    ISSN: 1600-0846
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background/purpose: Since in early melanoma (MM) and especially in in situ MM differential structures, which are diagnostic for MM may be lacking, pigment distribution asymmetry represents an important diagnostic feature. Our aim was to automatically assess pigment distribution in images referring to MMs, atypical nevi (AN) and clearly benign nevi (BN), and to evaluate the diagnostic capability of numerical parameters describing a non homogeneous distribution of pigmentation.Methods: An image analysis program enabling the numerical assessment of pigment distribution in melanocytic lesions (ML), based on evaluation and comparison of red, green, blue (RGB) colour components inside image colour blocks, was employed on 459 videomicroscopic digital images, referring to 95 MMs, 76 AN and 288 BN.Results: Significant differences in pigment distribution parameters (mean RGB distance, variance and maximum distance) between the three ML populations were observed, permitting a good discrimination of MMs. On the test set comprising 230 lesion images, the area under the curve value of the receiver operating characteristic curve was 0.933. For a D score equal to 0, corresponding to the best diagnostic accuracy (86.6%), a sensitivity of 87.5% and a specificity of 85.7% were obtained.Conclusion: This original evaluation method for digital pigment distribution, based on mathematical description and comparison of colours in different image blocks, provides numerical parameters to be implemented in image analysis programs for computer-aided MM diagnosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Skin research and technology 11 (2005), S. 0 
    ISSN: 1600-0846
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background/purpose: The assessment of colors is essential for melanoma (MM) diagnosis, both for pattern analysis on dermoscopic images, and when using semiquantitative methods. Our aim was to provide a simple, precise characterization and reproducible calibration of the color response for dermoscopic instruments.Methods: Three processes were used to correct the non-uniform illumination pattern of the instrument, to easily estimate the camera gamma settings and to describe the color space conversion matrices required to produce standard images, in any color space. A specific color space was also developed to optimize the representation of dermatoscopic colors. The calibration technique was tested both on synthetic reference surfaces and on real images by comparing the difference between the images colors obtained with two different equipments.Results: The differences between the images acquired by means of the two instruments, calculated on the reference patterns after calibration, were up to 10 times lower then before, while comparison of histograms referring to real images provided an improvement of about seven times on average.Conclusions: A complete workflow for dermatologic image calibration, which allows the user to continue using his own software and algorithms, but with a much higher informative content, is presented. The technique is simple and may improve cooperation between different research centers, in teleconsulting contexts or for result comparisons.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...