Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 38 (2000), S. 603-609 
    ISSN: 1741-0444
    Schlagwort(e): Femoral anteversion ; Rendering ; 3D imaging ; Measurement
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Femoral neck anteversion is the torsion of the femoral head with reference to the distal femur. Conventional methods that use cross-sectional computed tomography (CT), magnetic resonance or ultrasound images to estimate femoral anteversion have met with several problems owing to the complex, three-dimensional (3D) structure of the femur. These problems include not only the difficulty of defining the direction of the femoral neck axis and condylar line but also the dependency upon patient positioning. In particular, the femoral neck axis, the direction of the femoral head, known as the major source of error, is difficult to determine from either a single or several two-dimensional (2D) cross-sectional images. A new method has been devised for the measurement of femoral anteversion using the 3D imaging technique. 3D reconstructed CT images from the femoral head and trochanter to the distal femur are used to measure the anteversion. It is necessary to remove the soft tissue from the CT images and extract just the bone part. Then, the femoral anteversion is measured from a computer-rendered femur image. The 3D imaging method is compared with both the conventional 2D method and the physical method using 20 dried femurs. For the physical method, which is used as a reference value, a special apparatus is devised. The average difference between the results of the physical method and those of the 2D CT method is 5.33°. The average difference between the results of the physical method and those of the 3D imaging method is 0.45°. Seventy-four patients, who suffer from toe-in-gait disease, are tested to compare the 3D imaging method with the conventional 2D CT method. The average difference between the 2D and 3D methods is 8.6°, and the standard is 7.43°. This method provides a very accurate and reliable measurement of femoral anteversion, as it is virtually equivalent to the direct measurement of bisected dried femur in vitro.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 38 (2000), S. 610-616 
    ISSN: 1741-0444
    Schlagwort(e): Femoral anteversion ; 3D ; Modelling ; Measurement
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Femoral neck anteversion is the torsion of the femoral head with reference to the distal femur. Conventional methods that use cross-sectional computed tomography (CT), magnetic resonance or ultrasound images to estimate femoral anteversion have met with several problems owing to the complex three-dimensional (3D) structure of the femur. A 3D imaging method has been developed that virtually measures femoral anteversion on the 3D computer space with continuous CT slices; this 3D method provides more accurate and reliable results than conventional 2D CT measurements. A 3D modelling method is devised for the measurement of femoral neck anteversion. This method has advantages over the 3D imaging method, such as shorter processing time, reduced number of slices and an objective result compared with the 3D imaging method. The results of the 3D modelling method are compared with the conventional CT methods (2D CT method and 3D imaging method) using 20 dried femurs.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 27 (1994), S. 6541-6550 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 79 (1957), S. 4566-4567 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 81 (1959), S. 2652-2654 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Abdominal imaging 24 (1999), S. 202-204 
    ISSN: 1432-0509
    Schlagwort(e): Key words: Uterus, magnetic resonance imaging—Anomalies, congenital—Round ligament—Leiomyoma, degeneration.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. We report the magnetic resonance appearance of a case of round ligament leiomyoma that presented as a rapid growing inguinal mass in a patient with Mayer-Rokitansky-Kuster-Hauser syndrome.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1432-0630
    Schlagwort(e): 81.15 ; 68.55 ; 07.80
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau , Physik
    Notizen: Abstract Thin films of pure copper have been deposited on glass and Si(100) substrates using copper acetylacetonate [Cu(acac)2] and copper HexaFluoroAcetylacetonate [Cu(HFA)2] sources. A thermal, cold-wall, reduced pressure (3325–5985 Pa) Metal-Organic Chemical Vapor Deposition (MOCVD) process was employed. The effect of H2O vapor on the grain size, deposition rate, and resistivity was examined. Electrical resistivities of 2.4 μω cm for copper films deposited on Si(100) and 3.44 μω cm for copper films deposited on glass at substrate temperatures of 265° C and a [Cu(acac)2] source temperature of 147° C with the use of H2O vapor were measured. When [Cu(HFA)2] was used, the substrate temperature was 385° C and the source temperature was 85° C. An activation energy for the copper film deposition process was calculated to be 22.2 kJ/mol in the case of the [Cu(acac)2] source. A deposition rate of 11 nm/min was obtained with Cu(acac)2 as the source and the rate was 44.4 nm/min with the Cu(HFA)2 source; both were obtained with the use of H2O vapor. No selectivity was observed with either source for either substrate. The deposited films were fully characterized using XRD, LVSEM, SAXPS, and RBS.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 1432-1106
    Schlagwort(e): GABA-Regional distribution ; Rabbit ; Rat ; Guinea pig ; Baboon ; CNS ; Substantia nigra
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The regional distribution of GABA in the CNS of rabbit (17 regions), rat (14 regions), guinea pig (12 regions) and baboon (11 regions) was determined by sensitive enzymatic and fluorometric assay. In all species studied a high concentration of GABA was found in substantia nigra (8.5–10.1 mmoles/kg) and pallidum (6.5–8.2 mmoles/kg). Fairly high amounts were found in hypothalamus, superior and inferior colliculi, nucleus oculomotorius and dentate nucleus. The GABA concentration in spinal cord (white matter) had the lowest value.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1432-1106
    Schlagwort(e): L-glutamate decarboxylase ; Choline acetyltransferase ; Substantia nigra ; Strio-nigral fibre ; Inhibitory system
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary This study investigated the effect of strio-nigral hemitransection on the enzymes necessary for the synthesis and cataboiism of γ-aminobutyric acid, acetylcholine and dopamine in the caudate nucleus, the putamen, the pallidum and the substantia nigra of the baboon. After transection, more than 70% of the L-glutamate decarboxylase activity was missing from the substantia nigra ipsilateral to the location of the lesions, leaving all remaining regions unchanged. Choline acetyltransferase, acetylcholinesterase and monoaminoxidase activities failed, however, to be affected by the lesions, while glutamic-γ-aminobutyric transaminase was slightly decreased in the substantia nigra. These results strongly support our previous view that the strio-nigral neuron system is primarily an inhibitory one, in which γ-aminobutyric acid plays the role of transmitter. Confirming earlier investigations, a marked reduction of L-DOPA decarboxylase activity was induced by the lesions in the caudate nucleus and the putamen, which indicates that the nigro-striatal neuron system in the baboon is also dopaminergic. Neither the striatum nor the substantia nigra had a markedly diminished acetylcholine content after hemitransection. This strongly suggests that the acetylcholine in the striatum does not depend on the integrity of the strio-nigral connexions.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Experimental brain research 14 (1971), S. 95-104 
    ISSN: 1432-1106
    Schlagwort(e): GABA ; Strio-nigral neurons ; Elongated synaptic vesicles ; Hemitransection ; Bouton-degeneration
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Interference with the neuronal connection between the substantia nigra and striatum of rat by hemitransection at the subthalamic level or lesion of left side of striatum by a simple suction method was studied in relation to the concentration of γ-aminobutyric acid (GABA) in both regions. Time interval studies, at two, six, and twelve days after hemitransection, showed that the GABA concentration in substantia nigra had markedly decreased, whereas only a slight change was shown on the striatum of the operated side. Destruction of the striatum by suction caused a significant fall of the GABA content in the ipsilateral side of substantia nigra. However, destruction of the frontal cortex alone did not cause any marked change in the GABA content of the substantia nigra. In addition, electron microscopic studies disclosed that within the synaptic organization of the substantia nigra approximately 20 % of the boutons contained elongated synaptic vesicles, and that, following coagulation of the striatum, some large axosomatic terminals containing elongated synaptic vesicles also underwent degeneration.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...