Bibliothek

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (2.288)
  • 1980-1984  (4.319)
  • Analytical Chemistry and Spectroscopy  (6.605)
  • Nuclear reactions
Materialart
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 11-16 
    ISSN: 0935-6304
    Schlagwort(e): Pyrolysis gas chromatography ; microstructure determination ; syndiotactic copolymers ; styrenes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The composition and microstructure of syndiotactic para-methylstyrene/styrene copolymer was determined by a pyrolysis gas chromatography (Py-GC) method. This method uses the styrene and para-methylstyrene monomer peak intensities to determine the styrene and para-methylstyrene composition in the copolymer. The number average sequence length of styrene was calculated by using the triad peak intensities. Because of the low concentration of para-methylstyrene in the copolymer, the number average sequence length of para-methylstyrene was determined with formulas that incorporate the copolymer composition and the number average sequence length of styrene. The distribution of para-methylstyrene defined by the terms “percent of single units” and “percent of desired distribution” was calculated by the number average sequence of para-methylstyrene. This method has been tested with copolymers containing up to 24 mole% of para-methylstyrene. The composition results from Py-GC of para-methylstyrene and styrene copolymers used in this study were in excellent agreement with 1H-NMR results.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 24-28 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; ECD ; Micro-ECD ; GC detector ; organochlorine pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A new ECD, the HP 6890 Series Micro-ECD, was designed to address inherent deficiencies in classical electron capture detectors (ECD), especially with respect to sensitivity, linearity, dynamic range, and ruggedness. Several novel technologies were incorporated in the totally new design and were refined through practical testing and user feedback. Validation of the micro-ECD performance was accomplished through side-by-side testing of the Micro-ECD with previous ECDs following US EPA Contract Laboratory Program methods for pesticides and PCBs. In addition, extensive interviews were conducted with early users of the Micro-ECD who also had experience with other designs running a variety of ECD methods. The design and resulting performance improvements are described.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 33-38 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; chiral separation ; negatively charged chiral selectors ; capillary filling methods ; dual systems ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Data on the use of two chiral selectors, namely 18-crown-6 tetracarboxylic acid and a negatively charged cyclodextrin derivative (sulfated-β-cyclodextrin or carboxymethyl-β-cyclodextrin), in the same background electrolyte are presented. The use of such dual systems has a considerable influence on the resolution, as illustrated for the separation of tryptophan derivatives. Reduction of the consumption of chiral selector without significant loss in resolution was obtained by only partly filling the capillary and applying a run buffer without selector. This is illustrated for the chiral separation of tryptophan hydroxamate and the diastereomeric and enantiomeric separation of the dipeptide α/b-AspPhe-OMe.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 43-46 
    ISSN: 0935-6304
    Schlagwort(e): Green and roasted coffee ; diterpenes ; cafestol ; kahweol ; 16-O-methylcafestol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The three coffee diterpenes cafestol, kahweol, and 16-O-methylcafestol are mostly esterified with fatty acids. Little has been published about the diterpenes occurring in the free form. By means of gel permeation chromatography on Bio Beads S-X3, it is now possible to simultaneously analyze and quantify the small amounts of these compounds by RP-HPLC. In this way, free kahweol was first proved to be an ingredient of Robusta coffee. Various Arabica and Robusta coffees - both green and roasted - were investigated. Free diterpenes were found in green coffees in amounts below 200 mg/kg dry matter. In comparison to the respective total diterpene content determined by the same HPLC method after saponification of the coffee oil, the proportion of free diterpenes ranged from 0.7 to 3.5 %. During the roasting process, the three uncombined diterpenes behaved similarly: free 16-O-methylcafestol, cafestol as well as kahweol were degraded with increasing roasting temperature.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 52-54 
    ISSN: 0935-6304
    Schlagwort(e): Ethanol ; mobile phase ; factorial planning ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 63-66 
    ISSN: 0935-6304
    Schlagwort(e): Divinylbenzene copolymers ; exclusion limit ; size exclusion chromatography ; surface area ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 0935-6304
    Schlagwort(e): RP-HPLC ; GC-MS ; trioxanes ; thermolysis products ; quantitative analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 131-132 
    ISSN: 0935-6304
    Schlagwort(e): RP-HPLC ; theophylline ; asthma ; apnea ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 153-158 
    ISSN: 0935-6304
    Schlagwort(e): Vapor analysis ; nerve agents ; sulfur mustard ; data acquisition ; automation ; valve injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A method is presented for the continuous analysis of generated vapors of the nerve agents soman and sarin and the blistering agent sulfur mustard. By using a gas sampling valve and a very short (15 cm) column connected to an on-column injector with a “standard length” column, the system can either be calibrated or used for performing high speed gas analyses. When using a flame ionization detector, the detection limit was ca. 100 ppb (ca. 0.5-1.0 mg/m3). This technique is applied in inhalation toxicokinetic studies of nerve agents and mustard gas in the guinea pig.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 149-152 
    ISSN: 0935-6304
    Schlagwort(e): Large volume on-column injection ; flooded zone ; capacity of 0.53 mm i. d. precolumns ; solvent trapping ; solvent vapor exit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---0.53 mm i. d. uncoated precolumns of about 10 m in length followed by a solvent vapor exit have become a standard set-up for large volume on-column injection. It went unnoticed, however, that the introduction of a vapor exit requires two modification of previous working guidelines. First, the capacity of the precolumn to retain sample liquid is increased by a factor of 2.3-3 as a result of the around 100 times higher carrier gas flow rate. Secondly, it must be considered that this gain in retention of liquid is lost again upon closure of the exit: as the gas flow rate is reduced to a few mL/min, the layer of the residual sample liquid expands about 2.3-3 times. Hence, closure should occur late, and a section of the precolumn must be assigned for this secondary spreading.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 11
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 177-180 
    ISSN: 0935-6304
    Schlagwort(e): Fresh water systems ; burbot ; organotin compounds ; speciation analysis ; GC-AED ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 12
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 93-96 
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; PTV and on-column injectors ; milk fat triglycerides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The PTV (Programmable Temperature Vaporizer) is a split/splitless injector which allows the sample to be introduced at a relatively low temperature, thus affording accurate and reproducible sampling. After injection the PTV is rapidly heated to transfer the vaporized components into the capillary column. This type of injector has proved to be an efficient tool for the evaluation of fatty acids, essential oils, and pesticides in food analysis. In this work the suitability of PTV for the analysis of milk fat purity by the Official EU method was evaluated. This method is based on the gas chromatographic determination of triglycerides only according to their total number of carbon atoms followed by the application of formulae deriving from multiple linear regressions. The analysis is currently carried out with a packed column or a short capillary column and an on-column injection system. Several samples of pure milk fat and mixtures of milk fat with foreign fat were analyzed with the same capillary column and by using both PTV and on-column injection systems. The results show that the gas chromatographic profile obtained by PTV is comparable with that obtained by the on-column injector, while repeatability and reproducibility data meet the requirements indicated in the Official Method. Therefore, this study demonstrates that it is possible to use the PTV instead of the on-column injector to determine the purity of milk fat with this method.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 13
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 188-190 
    ISSN: 0935-6304
    Schlagwort(e): LC stationary phases ; porous graphitic carbon ; surfactant ; alkyl glycosides ; glycosides ; evaporative light scattering detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 14
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 195-200 
    ISSN: 0935-6304
    Schlagwort(e): Multi-dimensional gas chromatography ; comprehensive two-dimensional gas chromatography ; GC×GC ; BTEX ; aromatics ; reformulated gasoline ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Comprehensive two-dimensional gas chromatography (GC×GC) has been applied to the quantitative analysis of benzene, toluene, ethylbenzene, xylenes (BTEX), and all heavier aromatic compounds in gasoline. The two-dimensional chromatographic separation used volatility selection on the first-dimension column and polarity selection on the second-dimension column. In the resulting GC×GC chromatogram, aromatic species were resolved from other compound classes. Moreover, structurally related aromatics were grouped in a manner that facilitated identification and integration. The response of a flame ionization detector to each major aromatic group in gasoline was calibrated using internal standards. Quantitation produced results directly comparable with ASTM standard methods. The present GC×GC method can be expanded to analyze other gasoline components.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 15
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 205-212 
    ISSN: 0935-6304
    Schlagwort(e): Membrane extraction ; hollow fiber membrane ; thermodesorption ; GC-MS ; volatile organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The range of application of a commercial thermodesorption-cryofocussing unit connected to a gas chromatograph/mass selective detector was extended to water analysis by using it in conjunction with membrane extraction. A flow of nitrogen passes through a silicone hollow fiber immersed in the water sample and extracted volatile organic compounds are enriched in a sorption tube mounted on top of the extraction cell. The sorption tube is then placed in the thermodesorption unit and analyzed by GC/MS. The optimal extraction parameters of this combined method were found to be 30 min extraction at 20°C with a stirring speed of 1,250 rpm and a flow rate of 100 mL/min nitrogen using a silicone hollow fiber of 0.3 m length. Under these conditions the reproducibility of the method was 5.2-10.5% RSD. The linear dynamic range of the optimized method spans three orders of magnitude and detection limits were found to be 0.02-0.1 μg/L for cis/trans-1,2-dichloroethene, benzene, trichloroethene, chlorobenzene, bromobenzene, ethylbenzene, 1,1,2,2-tetrachloroethane, and 1,2/1,4-dichlorobenzene. The method was found to be suitable for compounds with boiling points up to 220°C as memory effects increased considerably from dichloro- to hexachlorobenzene. Highly contaminated groundwater samples were analyzed. Quantitative results corresponded well with those achieved with conventional headspace-GC/FID.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 16
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 222-224 
    ISSN: 0935-6304
    Schlagwort(e): High-performance liquid chromatography ; Artemisia capillaris ; phenolic compounds separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 17
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 217-221 
    ISSN: 0935-6304
    Schlagwort(e): HPLC ; UV detection ; linear range ; method validation ; Beer-Lambert law ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Determination of the linear range is one of the main concerns in validation of an HPLC analysis method. It is particularly important since single point calibration will be then used routinely. We proposed an iterative methodology to handle this problem. The idea was, at each step, to test statistically whether the following point belonged to the same regression line. The methodology was then used to evaluate quantitatively the effect on linear range of a shift in detection wavelength or of the detector bandwidth. Although experimental results were globally in accordance with spectroscopic theory, magnitudes observed were rather large. So the linear range could vary by a factor of over 2 with changes in conditions that remained within the range of current practical values. Changes in detection wavelength were limited to about fifteen nm around λmax and the detector used was considered to be representative of modern high-performance UV detectors. The question of how to take consequences in method validation into account was raised. The solution proposed recommended that the validation was undertaken in conditions as close as possible to those where the method would be conducted routinely. This means with the same instrumentation and on the product of interest for analyses.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 18
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 231-234 
    ISSN: 0935-6304
    Schlagwort(e): Trace analysis ; air samples ; BTX ; equilibrium-sorptive enrichment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 19
    ISSN: 0935-6304
    Schlagwort(e): Tebuthiuron ; GC-MS ; HPLC ; drinking water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 20
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 245-246 
    ISSN: 0935-6304
    Schlagwort(e): Chloride ; suppressed ion chromatography ; concrete ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 21
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 251-255 
    ISSN: 0935-6304
    Schlagwort(e): Multi-dimensional gas chromatography ; comprehensive two-dimensional gas chromatography ; GC × GC ; mass spectrometry ; petroleum ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Comprehensive two-dimensional gas chromatography coupled with mass spectrometric detection (GC × GC/MS) is a three-dimensional analytical method. In its application to petroleum analysis, the high peak capacity of GC × GC produced chromatographic resolution of over 750 peaks from a marine diesel fuel. The MS detector provided a full-scan mass spectrum for each resolved peak. The integration of an MS detector with GC × GC provides increased capability to identify minor components, determine members of homologous series, and characterize ordered peak patterns of related components that are visible in the GC × GC chromatogram.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 22
    ISSN: 0935-6304
    Schlagwort(e): Molecular imprinting ; PAH ; molecular recognition ; selectivity ; redox polymerization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A non-covalent type of molecular imprinting effect toward a polyaromatic hydrocarbon (PAH), viz. anthracene, was studied utilizing uniformly sized ethylene dimethacrylate (EDMA) polymer particles without functional host monomers. Although polymerization at 0°C initiated by a redox initiation system was expected to afford larger molecular imprinting effect due to stronger and more effective intermolecular interaction between the template and surface functional groups of the polymer, almost no imprinting effect was observed, while a much higher polymerization temperature of 70°C unexpectedly afforded a larger molecular imprinting effect for the template anthracene. In order to determine the unexpected imprinting effects observed, uniformly sized, macroporous un-imprinting EDMA polymer particles (base particles) were prepared by various polymerization techniques at different polymerization temperature as well as with different initiation systems. The careful studies proved that each kind of base polymer particle showed different molecular recognition ability, especially toward anthracene, which is depends upon the physical properties of each kind of base polymer particle. On the basis of these facts, we would propose that the potential molecular recognition ability of the un-imprinted base polymer particles is another important factor for realization of effective molecular imprinting alongside the factors reported previously.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 23
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 276-278 
    ISSN: 0935-6304
    Schlagwort(e): Cyclic carbonates ; thermal stability ; chemical stability ; gas phase chromatography ; liquid phase chromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 24
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 283-286 
    ISSN: 0935-6304
    Schlagwort(e): Evaporative light scattering detection ; capillary nebulizer ; packed capillary ; columns ; high temperature liquid chromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 25
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 303-304 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; food analysis ; pesticide residues ; thiabendazole ; imazalil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 26
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 305-307 
    ISSN: 0935-6304
    Schlagwort(e): High temperature gas chromatography ; chocolate analysis ; triacylglycerols determination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 27
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 309-314 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrochromatography ; isomers ; pneumocandins ; separation ; transition metal ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The novel separation of a 3-hydroxyproline containing a semi-synthetic macrocyclic antifungal agent from its structurally related 4-hydroxyproline isomer using capillary electrochromatography (CEC) is described. The molecular weight of the two compounds is 1093 Daltons and they differ only in the placement of a proline -OH group. The separation is achieved using capillaries packed or coated with ODS particles (C18) or with glycerol bound to silica through a carbon chain linker. The presence of a transition metal (Ni(II), Ag(I), Zn(II), or Cu(II)) as buffer additive in the phosphate buffer (pH=2.5):CH3CN (75:25, v/v) is essential to achieve a baseline separation. HPLC columns packed with similar ODS particles showed no selectivity. Capillaries packed or coated with C18 material under similar conditions showed partial selectivity compared to the glycerol capillaries. Some fundamental aspects of CEC, such as capillary temperature, applied voltage, and buffer composition were varied in order to study the mechanism of the separation. This mechanistic study included the testing of first and second row transition metal ions (individually or in combination), the use of organic solvents, the use of an ion pair reagent, and the use of β- and γ-cyclodextrin to assess the impact on the separation. The resolution was dependent on the metal ion concentration and is consistent with a mechanism of metal-oxygen complexation through the hydroxyl groups of the two isomers and glycerol.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 28
    ISSN: 0935-6304
    Schlagwort(e): Solid phase microextraction (SPME) ; capillary gas chromatography ; detection limits ; wine aroma compounds ; classification of wines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Headspace-SPME followed by capillary gas chromatography/mass spectrometry was used to investigate 90 German wines originating from different grape varieties, vintages, and growing areas. Aromagrams obtained in single ion monitoring (SIM) and in the full scan detection mode (SCAN) of quadrupole mass spectrometer were compared. Detection limits, reproducibility, and linearity for some aroma relevant substances were estimated over a wide concentration range. The advantages of SIM data set (lower detection limit, better reproducibility and linearity in the smaller concentration ranges) should be reflected in more reliable results in classification of wines. To verify these expectation, classification of variety by discriminant analysis was performed with cross validation using both SIM and SCAN data sets including 19 aroma compounds, respectively.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 29
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 335-338 
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC trace analysis of C2-C4 hydrocarbons ; signal-to-noise ratio, improvement ; post column cryogenic trapping ; thermal remobilization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A method for the improvement of signal-to-noise ratios and hence detection limits in capillary gas chromatographic trace analysis of C2-C4 hydrocarbons was developed. It is based on the post column cryogenic trapping of the separated hydrocarbons using liquid nitrogen as coolant and its fast reinjection into the detector by rapid heating of the capillary tubing used for trapping. The improved signal-to-noise ratios were applied to decrease the sample volume and/or to lower the detection limit 10 to 27 times. The concentrations of these hydrocarbons in an urban air sample determined without and with post column cryogenic trapping were in good agreement but the precision was better when applying the cryogenic trapping mode.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 30
    ISSN: 0935-6304
    Schlagwort(e): Multidimensional GC ; enantioselective gas chromatography ; lemon oil ; monoterpene hydrocarbons ; monoterpene alcohols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---This paper describes a fully automated, multidimensional, double-oven GC-GC system, developed in our laboratory. The system is based on the use of mechanical valves which allow the multitransfer of different fractions during the same GC analysis and the use of the two GC independently when the multitransfer options is not used. Pneumatic and electronic circuits permit maintenance of constant retention times in the pre-column, even for the components eluted after numerous transfers. The system has been used for the determination of the enantiomeric distribution of β-pinene, sabinene, limonene, linalol, terpinen-4-ol, and α-terpineol in lemon oils. The results obtained allowed the characterization of cold-pressed lemon oils.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 31
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 362-366 
    ISSN: 0935-6304
    Schlagwort(e): Pentafluorophenyldimethylsilyl (flophemesyl) chloride ; split and splitless injection ; derivatised sterol analysis ; synthetic pyrethroids ; injector liner activity ; gas chromatographic electron capture detection ; multidimensional gas chromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 32
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 367-372 
    ISSN: 0935-6304
    Schlagwort(e): Sweeping ; sample stacking ; micellar electrokinetic chromatography (MEKC) ; retention factor (k) ; sample matrix ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The concept of sweeping has been used in electrokinetic chromatography to explain the concentrating mechanism in micellar electrokinetic chromatography when the sample matrix is a high resistivity non-micellar aqueous solution. Theoretical and experimental studies were undertaken. It was found that the total focusing effect is brought about by the cumulative effect of sweeping and sample stacking. For better analytical results, compounds showing low to moderate retention factors (k) and compounds showing high values of k must be dissolved in low and high conductivity matrices, respectively.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 33
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 379-385 
    ISSN: 0935-6304
    Schlagwort(e): CZE ; indirect UV detection ; anions and organic acids ; environmental samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Capillary zone electrophoresis (CZE) with indirect UV detection was developed for the simultaneous determination of inorganic anions and organic acids in environmental samples. Various aromatic acids (benzoic, phthalic, trimellitic, and pyromellitic acids) were evaluated as background electrolytes (BGEs) to give high resolution and detection sensitivity. Co-electroosmotic conditions such as the concentration of BGE, electrolyte pH, and EOF modifier were systematically investigated. Three inorganic anions and ten organic acids were determined simultaneously in 10 min using an electrolyte containing 10 mM phthalic acid, 0.5 mM myristyltrimethylammonium bromide (MTAB), and 5% methanol (MeOH) (v/v) at pH 5.60. Linear plots for the test solutes were obtained in the concentration range 0.01-1.0 mM with detection limits in the range 5-30 μM. The proposed method was successfully demonstrated for the determination of inorganic anions and organic acids in natural water, soil, and plant extracts after direct sample injection.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 34
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 395-402 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; pulsed splitless injection ; pesticide residues ; matrix effects ; retention gap ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The applicability of pulsed splitless injection to the gas chromatographic analysis of pesticide residues in fruit and vegetables has been evaluated. 22 pesticides belonging to different chemical classes, including those known to be liable to matrix induced response enhancement, were selected for the study. The parameters of pressure pulse have been tested for optimum performance of injection. Application of the pressure pulse was found to decrease matrix effects during analyses of real samples. Further decline of matrix effects was obtained using higher sample injection volumes. The installation of a deactivated retention gap was necessary to obtain good peak shapes with injection volumes exceeding 1 μL of sample. Up to 4 μL was then injected without peak distortion and consequent loss of resolution. Using 4 μL pulsed splitless injection, matrix effects were almost completely eliminated even at very low concentration levels of analytes. The highest matrix effects observed for tested compounds at the lowest concentration level tested were in the range of 110-122%.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 35
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 403-413 
    ISSN: 0935-6304
    Schlagwort(e): Constant length optimization ; constant efficiency optimization ; efficiency-optimized flow rate ; fast GC ; film inefficiency factor ; high pressure drop ; speed-optimized flow rate ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: At the high pressure drop required for the fast analysis of complex mixtures, the equations for the column plate height, H, and plate duration, Q, as functions of the carrier gas velocity, u, differ substantially from the equations for the same quantities expressed via the carrier gas flow rate, F. While u as an independent pneumatic variable is more convenient for the theoretical studies, F is a more convenient as a control parameter in practical applications. Equations for H vs. u and for Q vs. u from Parts 1 and 2 are transformed here into expressions for H vs. F and Q vs. F. An efficiency-optimized flow rate (EOF) and a speed-optimized flow rate (SOF) are found. Expressions for these two quantities are considerably simpler than their velocity-based counterparts. In particular, SOF does not depend on column length, film thickness, and pressure drop.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 36
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 417-420 
    ISSN: 0935-6304
    Schlagwort(e): Sample preparation ; nitrophenols ; PCP ; 2,4-D ; liquid chromatography ; supported-liquid-membrane extraction ; environmental monitoring ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 37
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 427-428 
    ISSN: 0935-6304
    Schlagwort(e): p-Chlorophenol ; urine ; SPME ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 38
    ISSN: 0935-6304
    Schlagwort(e): Mycotoxin ; T2 ; solid phase microextraction ; GC/FID ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 39
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 339-342 
    ISSN: 0935-6304
    Schlagwort(e): Chlorophyll ; SFC ; supercritical fluid chromatography ; vegetables ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Complex mixtures of chlorophyll degradation products may arise during processing and storage of vegetable oil and green plant materials like broccoli and spinach. Determination of these compounds is important in the area of food chemistry. Therefore a method using packed column supercritical fluid chromatography (SFC) has been developed. The method comprises chromatography using a simple gradient of methanol in carbon dioxide at constant column back pressure of 30 MPa and a column temperature of 40°C. Effects of pressure and mobile phase composition showed the importance of applying a modifier gradient for optimal separation of the chlorophyll products. The method permits separation of 15 chlorophyll derivatives including chlorophyll a and b, pheophytins, and pyropheophytins on a C18 column in about 20 minutes. Identifications of the individual peaks were based on reference compounds, the retention order of the compounds, and their absorption spectra.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 40
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography ; gas chromatography-mass spectrometry ; essential oil analysis ; Lepechinia schiedeana ; antioxidant activity ; lipid peroxidation ; Ledol; Ledol HMQC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Steam distillation (SD), simultaneous distillation-solvent extraction (SDE), microwave-assisted solvent extraction (MWE), and supercritical (CO2) extraction (SFE) were used to isolate secondary metabolites from Lepechinia schiedeana. The various extracts were analyzed by capillary gas-chromatography, on poly (dimethylsiloxane) (DB-1) and poly(ethyleneglycol) (INNOWAX), 60 m columns, using FID or MSD (EI, 70 eV). Kováts indexes, mass spectra, or standard compounds were employed for compound identification. 43, 61, 67, and 79 compounds at concentrations above 0.01% were detected in the SD, SDE, MWE, and SFE extracts, respectively. Ledol, C15H26O, was the major constituent (20.04-36.87%) in all extracts. Oxygenated sesquiterpenes (24.36-43.14%), C10H16, monoterpenes (27.70-39.87%), and C15H24, sesquiterpenes (10.04-22.22%) were the main groups of compounds present in SD, SDE, MWE, and SFE extracts. Heavy hydrocarbons (Cn 〉 15), diterpenoids, and phytosterols were found only in MWE and SFE extracts. The antioxidant activity of Lepechinia schiedeana was measured by the HRGC quantification of the volatile carbonyl compounds, final products of lipoxidation, released in a model lipid system (sunflower oil) by the effect of the Fenton reagent. The concentration of volatile carbonyl compounds decreased by 65% when lipid oxidation was induced in the presence of macerated Lepechinia plant. The protection of polyunsaturated acids in sunflower oil was also studied by measuring their concentrations after heating of the oil (180°C, 2 h) with and without macerated Lepechinia plant.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 41
    ISSN: 0935-6304
    Schlagwort(e): Silver ion HPLC ; long chain polyunsaturated fatty acid ; isopropanol ; separation of positional isomers ; degree of unsaturation ; normal phase retention effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A high resolution approach to silver ion HPLC was studied for the separation of positional isomers of triacylglycerols (TAGs) containing long chain polyunsaturated fatty acids (PUFA) such as eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and docosapentaenoic acid (DPA) in enzymatically synthesized structured TAGs. Isopropanol was used as a novel modifier in a hexane-acetonitrile based mobile phase for silver ion HPLC. Peak identification was based on HPLC-mass spectroscopy and selectivities of lipases. Positional isomers of TAGs containing one molecule of EPA, DHA, or DPA with saturated fatty acids (FAs) such as caprylic acid and palmitic acid were separated within 13 min using a gradient of hexane-isopropanol-acetonitrile as mobile phase. TAGs containing two or more EPA, DHA, or DPA were also separated from each other within 25 min, but their positional isomers were unresolved. The retention characteristics of the TAG were found to be related to the number of carbon atoms in the FAs present in addition to the number of double bonds and their isomeric configuration. One isomer with an unsaturated FA in the sn-2 position eluted faster than the other with the unsaturated FA in the sn-1 or 3 position. Species with longer chain FAs attached to TAGs with the same degree of unsaturation eluted faster than those that have shorter chain FAs. For example, docosapentaenoylhexadecanoyloctanoin (DPA/C16/C8) was eluted faster than dioctanoyldocosapentaenoin (DPA/C8/C8).
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 42
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 373-378 
    ISSN: 0935-6304
    Schlagwort(e): Electrophoresis ; electrophoretic mobilities ; CZE ; MEKC ; peptides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A computer model is presented for the prediction of the electrophoretic mobilities of peptides from physical constants derived from their amino acid sequences. The model assumes that the electrophoretic mobility can be represented by a product of four functions according to the relation:  lcomp= l(L)w(W)q(Q)c(CC), where L (a length parameter) is represented by the number of amino acid residues of the peptide, W (a width parameter) is represented by the average residue mass, Q = the charge of the peptide, and CC = the position of the center of charge relative to the center of mass. The model was used to calculate the electrophoretic mobilities of peptides in a 50 mM phosphate buffer at pH 2.5. Sixty-four test peptides ranging in size from 2 to 39 amino acid residues were used for this study. The calculated mobilities show excellent correlation with experimental measurements with a correlation coefficient greater than 0.98.
    Zusätzliches Material: 5 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 43
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 386-390 
    ISSN: 0935-6304
    Schlagwort(e): Sulfur chemiluminescence detection ; sulfur simulated distillation ; boiling point distribution ; simultaneous FID/SCD analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A gas chromatographic system for the simultaneous acquisition of hydrocarbon and sulfur chromatograms was developed. Detection of sulfur compounds is achieved using a sulfur chemiluminescence detector (SCD) mounted in series with a flame ionization detector (FID). A constant fraction of the effluent of the FID is transferred to the SCD by means of a fixed restrictor. Unlike previous versions of this approach, the FID is not used to generate the chemiluminescent sulfur species. Rather, the FID is operated under optimum conditions for hydrocarbon analysis and a furnace is used to generate the chemiluminescent sulfur species. The system permits dual acquisition of the hydrocarbon and sulfur signals in a single analysis with a single column, since the detectors are operated in a serial fashion. The application of sulfur simulated distillation using this approach was examined, since this requires simultaneous universal and sulfur selective detection. Precision of absolute response of both the FID and SCD was typically less than 2% RSD for a standard reference material.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 44
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 391-394 
    ISSN: 0935-6304
    Schlagwort(e): REMPI-TOFMS ; laser mass spectrometry ; supersonic jet ; GC-MS ; interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The laser-based methods Laser Induced Fluorescence (LIF) and Resonance-Enhanced Multi-Photon Ionization (REMPI) can be used as highly selective detection modes for gas chromatography (GC). One major prerequisite for successful application of these detection methods is the availability of appropriate and reliable interfaces between the GC effluent and the molecular beam inlet. When a pulsed supersonic molecular beam (jet) source is used, the analyte molecules are efficiently cooled, allowing maximum selectivity of the laser spectroscopic detection methods. However, several technical problems have to be solved for practical realization of a GC-supersonic jet valve hyphenation. The pulsed jet interface should not interfere with the GC properties and the supersonic molecular beam properties. Further a good working cycle for the conversion from the continuously flowing GC current to the pulsed jet gas flow should be attained. This paper presents a novel setup of a GC-pulsed jet interface. The construction allows temporal and spatial compression of the analyte molecules in jet gas pulse and thus an increase of the detection sensitivity. Moreover, the GC effluent comes into contact only with glass surfaces and not with valve parts like plungers and seals. This reduces memory effects and sample decomposition. The valve setup is tested with a REMPI-TOFMS instrument.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 45
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 414-416 
    ISSN: 0935-6304
    Schlagwort(e): Selenium ; water ; SPME ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A method for the selective determination of Se4+ and Se6+ using solid phase microextraction (SPME) and GC/MS analysis is presented. Se4+ is selectively derivatized by reaction with 4,5-dichloro-1,2-phenylenediamine to form the corresponding piazselenolo complex, extracted by the SPME fiber, and determined by GC/MS. The RSD at a 5 μg/L concentration was 9.88% and the theoretical detection limit 6 ng/L. The method was employed to test real matrices; tap and river water were analyzed before and after spiking giving a recovery rate of 102% in river water and 97% in tap water.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 46
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 421-423 
    ISSN: 0935-6304
    Schlagwort(e): Enantioselective gas chromatography ; 2,3-di-O-methyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin ; 2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin ; γ-dithiolactones ; olfactometry ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 47
    ISSN: 0935-6304
    Schlagwort(e): HPLC ; nitrotyrosine ; nitrotocopherol ; analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---For three decades, high performance liquid chromatography has proven itself to be a powerful, flexible, and inexpensive tool for basic and clinical research. Recent advances in our understanding of disease have prompted a demand for more sensitive and selective methods of routine bioanalysis, particularly with respect to the determination of oxidative metabolites and biomarkers of oxidative stress. Multidimensional detectors utilizing coulometric arrays offer a solution to these research needs. The challenge to the bioanalyst is now to creatively apply HPLC-ECD technology to promising research and clinical enterprises.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 48
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 449-453 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; experimental design ; cyclodextrin ; chiral separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Orthogonal design and uniform design were used for the optimization of separation of enantiomers using 2,6-di-O-methyl-β-cyclodextrin (DM-β-CD) as a chiral selector by capillary zone electrophoresis. The concentration of DM-β-CD, buffer pH, running voltage, and capillary temperature were selected as variable parameters, their different effects on peak resolution were studied by the design methods. It was concluded that orthogonal design offers a rapid and efficient means for testing the importance of individual parameters and for determining the optimum operating conditions. However, for a large number of both factors and levels, uniform design is more efficient. The effect of addition of methanol and citric acid buffer on the separation of enantiomers was also examined.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 49
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 547-552 
    ISSN: 0935-6304
    Schlagwort(e): Water analysis ; polar pollutants ; solid-phase extraction ; chemically-modified polymeric resins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---This study assesses how the physical characteristics of styrene-divinylbenzene (PS-DVB) resins affect the extent to which they are modified when they are functionalized, and how they affect recoveries in on-line solid-phase extraction (SPE) of some polar phenolic compounds, pesticides, and metabolites from water samples which were analyzed by liquid chromatography and UV detection. For this purpose, three commercial PS-DVB resins with different physical characteristics (Amberchrom GC-161m and two different PLRP-S resins) were chemically modified by placing a hydrophilic group, an o-carboxybenzoyl moiety, on their surface; although the physical characteristics are different, the extent of modification did not vary significantly. The results from the SPE process with each sorbent were related to their physical and chemical properties. The polymers with higher surface area provided better recoveries. Moreover, the recoveries for these analytes were better with the chemically-modified polymers due to the higher polarity of these sorbents. The best recovery values were with the sorbent obtained from the chemical modification of Amberchrom GC-161m, the commercial sorbent with higher surface area. For instance, in the analysis of 50 mL of a sample of 2 μg L-1, the recovery of phenol was 40% with Amberchrom GC-161m and 65% with the chemically-modified Amberchrom GC-161m.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 50
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 565-588 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Kovats retention index ; vapor pressure ; boiling point ; Wilson activity coefficient ; binary phase diagrams ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Non-ideal mixing in a dimethylsilicone stationary phase is modeled according to the Wilson activity coefficient. Pure liquid vapor pressures of alkylated compound series are calculated from capillary GLC retention with the functional group heat of solution in a polymer solvent. The new method uses the Kovats index, molar mass, and functional group to determine the bubble line of a compound. Boiling points at reduced and normal pressure are compared to literature values of 194 gasoline components. An unlike molecular pair interaction parameter is derived, using only bubble line data of the pure liquids. Binary phase diagrams are constructed and compared to vapor liquid equilibrium data.
    Zusätzliches Material: 22 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 51
    ISSN: 0935-6304
    Schlagwort(e): Computer modeling of GC ; computer simulation of GC ; computer-assisted GC analysis ; GC multicolumn analysis ; heart cutting GC analysis ; computer-assisted column design ; computer-assisted selectivity tuning ; retention index mapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The analysis of four components in a mixture containing many possible interferents is simplified by heart-cutting serially connected columns containing stationary phases of widely different polarities. The design of the proper lengths of the two columns and timing the heart-cuts is accomplished with the aid of a computer simulation of the problem. The computer program calculates the proper lengths of column to produce the shortest analysis time and also outputs the predicted chromatograms from both columns. The chromatogram from the first column is used to construct the timing gates for the heart-cuts and the chromatogram from the second or analytical column is used to set integration gates for the selected compounds of interest.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 52
    ISSN: 0935-6304
    Schlagwort(e): Large volume injection ; packed capillary LC ; temperature programming ; retinyl esters ; vitamin A ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A non-aqueous isocratic reversed-phase packed capillary high performance liquid chromatography method for the determination of retinyl esters, utilizing temperature programming and on-column focusing large volume injection, has been developed. The stationary phase material was C30, and the mobile phase consisted of acetonitrile-dichloromethane (70 : 30, v/v). A three-step temperature program, starting at 10°C for 10 min, then 1°/min to 30°C, and finally 2.5°/min to 70°C, was found most appropriate. Compared to an isothermal separation at 25°C, this temperature program provided improved peak resolution, enhanced peak shapes of the last eluting compounds, and a reduction of the overall elution time. A mass limit of detection of 27 pg was found with respect to retinyl palmitate, using UV detection with an “U” shaped flow cell at 327 nm. This corresponds to a concentration limit of detection of 2.7 pg/μL, when utilizing an injection volume of 10 μL. The concentration of retinyl palmitate in arctic seal liver samples was estimated to be 62.6 μg/g liver.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 53
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 501-508 
    ISSN: 0935-6304
    Schlagwort(e): Fast GC ; film inefficiency factor ; high pressure drop ; thick film columns ; thin film columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The negative effect of the liquid stationary phase film thickness on the column efficiency is strongest for peaks with retention factors, k, in the vicinity of k = 0.3-0.4 and rapidly diminishes with the departure of k from that region. Additionally, at the high pressure drop required for fast analysis of complex mixtures, the negative effect of the same film thickness diminishes with the increase in column length, regardless of the k values. In practice, it is recommended to ignore the film thickness and optimize the columns as thin film ones regardless of their actual film thickness. Accounting for the film thickness results only in a modest improvement in the resolution for a few affected peaks - those with k = 0.3-0.4. However, this improvement comes at the cost of a substantial increase in analysis time, and should be used only as the action of the last resort.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 54
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 514-520 
    ISSN: 0935-6304
    Schlagwort(e): Solid-phase extraction ; high temperature - gas chromatography ; gas chromatography - mass spectrometry ; wax esters fennel seed oil ; caraway seed oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A rapid method for the isolation and quantitative determination of wax esters in vegetable oils was developed. For the first time wax esters in oils were separated from the triglyceride matrix by means of solid-phase extraction, which allows rapid sample preparation in parallel and therefore a high sample throughput. The thus obtained wax ester fractions of fennel and caraway seed oils were analyzed by high temperature gas chromatography. GC-MS analyses were carried out using electron impact ionization in order to characterize the wax ester fraction. With respect to the results of the GC-MS analyses different isomers of saturated wax esters with the same carbon number were observed. Additional monounsaturated wax esters with an unsaturated fatty acid moiety were identified.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 55
    ISSN: 0935-6304
    Schlagwort(e): Clusia criuva Cambess ; counter-current chromatography ; flavonoids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The family Guttiferae belongs to the superorder Theiflorae, order Theales and according to Dahlgren's system of classification, it is equivalent to Hypericaceae (=Clusiaceae) [1]. This family consists of 49 genera encompassing over 1000 species of wide distribution in the tropics as shrubs and trees [2]. Plants of the genus Clusia have been used in folk medicine for the treatment of different kind of illness such as: febrifuge, anti rheumatic, purgative, for stomach problems and, in Brazil, they are very commonly used to heal wounds [3]. The key of any study of material from natural sources is the availability of suitable separation methods for the isolation of pure products [4-6]. Tentatives for separations using chomatography on solid support phases were not very efficients in the fractionation of Clusia criuva Cambess methanolic/ethyl acetate extracts. However, the use of counter-current chromatography, an all liquid technique, showed advantages in comparison with the more traditional liquid-solid separation methods and even with HPLC. In this sense it was possible to isolate flavonoid glycosides from ethyl acetate extract of Clusia criuva, in a very short operation time.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 56
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 541-546 
    ISSN: 0935-6304
    Schlagwort(e): Solvating gas chromatography ; gas chromatography ; fast separation ; pesticides ; herbicides ; aldehydes ; packed capillary columns ; polymer-encapsulated silica ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Rapid separations of selected environmentally important polar compounds using polymer-encapsulated silica stationary phases and a carbon dioxide mobile phase under solvating gas chromatography (SGC) conditions are reported. Ten underivatized short chain aldehydes and ten nitrogen-containing herbicides were separated within 1 min and 5 min, respectively, using a 30 cm×250 μm i. d. column packed with diol-bonded, polyethylenimine (PEI)-coated, and hexamethyldisilazane (HMDS)-end-capped silica particles (5 μm, 120 Å). Seven organophosphorus pesticides were resolved in less than 5 min using a 30 cm×250 μm i. d. column packed with polymethylhydrosiloxane-deactivated and SE-54 encapsulated silica particles. Separation numbers per unit time increased with pressure and temperature ramps. Both rapid pressure and temperature programming can be used to increase the speed of SGC. The effects of pressure and temperature on apparent retention factors of solutes with various polarities were investigated using diol-PEI-HMDS silica particles in SGC.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 57
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 559-564 
    ISSN: 0935-6304
    Schlagwort(e): Liquid chromatography ; dead time ; multiparametric least-squares adjustment ; homologous series ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---In reversed phase liquid chromatography (RP-HPLC), the validity of a multiparametric non-linear least-squares regression iterative method for the determination of the column dead time tM and the regression parameter (slope b), based on the use of alkan-2-ones, alkyl aryl ketones, and 1-nitroalkanes has been evaluated. The determination of tM and b has been extensively studied for two mobile phase systems acetonitrile-water and methanol-water on seven octadecyl-C18 and one octyl C8 analytical columns. The calculated tM and b values were compared with those obtained by Guardino's and Grobler's methods. The influence exerted thereon by the nature of the homologous series, the mobile phase composition, and the packing materials were investigated.
    Zusätzliches Material: 5 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 58
    ISSN: 0935-6304
    Schlagwort(e): SFE ; experimental design ; additives ; recycling ; polyolefins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The performance and feasibility of supercritical fluid extraction (SFE) applied to the extraction of some antioxidants (Irganox 1076, Irgafos 168) and one UV-stabilizer (Chimassorb 81) from both virgin and recycled low density polyethylene (LDPE), and virgin high density polyethylene (HDPE) are studied. Due to the high number of variables a full-factorial design has been applied to minimize the number of experiments required to reach the optimum extraction conditions. Further analysis has been carried out off-line by reversed-phase HPLC. Modification of the physical properties of the polymeric matrix and increased number of recycling cycles as well as the influence of physical properties on the efficiency of SFE are also discussed.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 59
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 595-598 
    ISSN: 0935-6304
    Schlagwort(e): Xylitol ; samarium ; weak association ; equilibrium constant ; capillary electrophoresis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 60
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 599-603 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrochromatography ; retention ; mixed stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Most commercially available instruments for capillary electrochromatography (CEC) have a fixed configuration and lack the flexibility to use shorter columns. Applying a blended stationary phase (a phase consisting of a given ratio of bare silica and reversed phase material) can simulate columns of different length in CEC. The goal of this work was to examine the effect of the degree of blending of reversed-phase columns (with bare silica) on the speed of the separation of neutral compounds in CEC. Optimum column packing mixture was determined from the variation of the solute retention factors as a function of the ratios of blending of reversed-phase and bare silica. By adjusting the column composition, solute retention factors and the analysis run time were halved when compared to a pure reversed-phase column of the same length. Stationary phase blending can be considered as an additional parameter to mobile phase variation, column temperature and applied electric field for the optimization of selectivity and analysis time. By adjusting the stationary phase composition, mobile phase composition, column temperature and applied electric field, the analysis run time of neutral components was decreased more than 75% when compared to a separation obtained on neat reversed-phase column of the same dimensions. The linear dependence of the retention factors as a function of the blend ratio (reversed phase/bare silica) offers a framework for designing a “blended” packed capillary column for CEC separations.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 61
    ISSN: 0935-6304
    Schlagwort(e): Liquid chromatography ; retention index ; multiparametric least-squares adjustment ; homologous series ; nitramines ; nitroaromatics ; aminoaromatics and nitrophenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---In reversed phase liquid chromatography, the retention indices of some neutral and acidic explosives and related compounds (nitramines, nitroaromatics, aminoaromatics, and nitrophenols) based on the alkan-2-one, alkyl aryl ketone, and 1-nitroalkane retention index standards have been determined by the application of a new mathematical adaptation method, viz. a multiparametric least-squares regression iterative method. This method was applied to two types of columns. The first group includes six octadecyl-C18 columns with different packing materials and obtained from different manufacturers, while the second group comprises one octyl-C8 column. The retention indices have been extensively studied using either methanol-water or methanol-phosphate buffer mobile phase systems. The calculated multiparametric retention indices values were compared with those obtained by Guardino's, Grobler's, and Kovàts' methods. The influences of the concentration of the organic modifier in the mobile phase, aqueous mobile phase pH, and the column packing material on the retention indices of the explosives were also investigated. Good agreement was observed between the retention indices calculated by the use of the four mathematical methods for both neutral and acidic explosives.
    Zusätzliches Material: 4 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 62
    ISSN: 0935-6304
    Schlagwort(e): Organochlorine compounds ; pesticides ; food analysis ; tomatoes ; GLC-ECD ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A method is described for the simultaneous extraction and determination of twenty organochlorine pesticides residues [hexachlorocyclohexane (HCH) isomers (α, β, γ, δ), aldrin, dieldrin, endrin, heptachlor and its epoxide (HE), hexachlorobenzene (HCB), α-endosulfan, o,p′-DDD, p,p′-DDD, o,p′-DDE, p,p′-DDE, o,p′-DDT, p,p′-DDT, dicofol, methoxychlor, and mirex] that were spiked in tomatoes. Samples were extracted with ethyl acetate, and the extract was subjected to a rapid clean-up using a Florisil column. The residues were determined by GLC-ECD using two columns of different polarity. The calibration graph correlation coefficient ranged from 0.9903 to 0.9990. The recoveries ranged from 95 to 99% with relative standard deviation ranging from 0.5 to 14.7% in the concentration range 0.005 to 0.2 μg/g. The limits of detection ranged from 0.004 to 0.05 μg/g and the limits of quantification ranged from 0.005 to 0.174 μg/g.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 63
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 628-630 
    ISSN: 0935-6304
    Schlagwort(e): p-Nitrophenol ; urine ; SPME ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 64
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 635-638 
    ISSN: 0935-6304
    Schlagwort(e): High resolution gas chromatography ; thermal desorption ; archeological cosmetic powders ; PTV injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 65
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 666-670 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrochromatography ; mixed packing technique ; electroosmotic flow ; retention mechanism ; fast analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Mixed packing capillary electrochromatography (MP CEC) with the stationary phase comprising a physical mixture of strong cation exchange (SCX) phase and octadecysilyl (ODS) phase was developed. With the existence of a sulfonic acid group on the surface of SCX, not only could the electroosmotic flow (EOF) remain high at low pH, but also the hydrophilicity of the stationary phase was increased greatly, leading to broad adaptable ranges of both pH and organic modifier concentration in the mobile phase. At the same time, with the coexistence of C18 on the surface of ODS, both the retention and the resolution of samples were improved. Accordingly, MP CEC combined the advantages of both SCX and ODS columns. Effects of operation parameters on EOF and the capacity factors of solutes as well as the retention mechanism of such a column were studied systematically. In addition, MP CEC columns were used in the analysis of strong polar solutes as well as for the high speed separation of acidic, basic, and neutral compounds in a single run.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 66
    ISSN: 0935-6304
    Schlagwort(e): Enantioselective capillary gas chromatography ; chiral stationary phase ; chiral recognition mechanism ; cholic acid ; cyclocholates ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The suitability of cyclocholates as chiral selectors in gas chromatography has been evaluated. We present the synthesis and characterization of two cyclocholates, viz. 3α,7α-diacetoxycyclo[3]cholate and 3α,7α-diacetoxycylo[4]cholate. Mixtures of these new selectors with polysiloxanes were tested as chiral stationary phases in capillary gas chromatography. Several enantiomer separations of common racemates were achieved with the 3α,7α-diacetoxycyclo[3]cholate at 10% in OV-1701 (w/w). It was shown that column efficiency was strongly dependent on temperature and that enantioselectivity was very sensitive to column conditioning. This chromatographic behavior suggested that cyclocholates were only dispersed in polysiloxane. Thus, it was assumed that chiral discrimination occurred via enantioselective adsorption interactions of enantiomers at the surface of the solid chiral selector dispersed in the polysiloxane matrix OV-1701.
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 67
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 683-686 
    ISSN: 0935-6304
    Schlagwort(e): Vacuum gas oils ; packed column chromatography ; n-paraffins ; carbon number distribution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Gas chromatographic methods are of widespread use in the petroleum industry for assessing petroleum and derivatives quality. The feedstocks for catcracking processes are very sensitive to the n-paraffin contents, which can be accurately determined using capillary column chromatography. Nevertheless, packed column chromatography does have potential advantages, viz. sometimes shorter analysis times, lower costs, higher column capacity, for vacuum gas oil analysis. This paper presents a method for such a determination using a Dexsil-300 packed column. The results obtained (n-alkane contents, carbon number distribution) agree fairly well with those obtained on a 30 m × 0.25 mm DB-1 fused silica capillary column.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 68
    ISSN: 0935-6304
    Schlagwort(e): Coupled GPC-GC ; gel permeation chromatography ; on-column interface ; co-solvent trapping ; gas chromatography ; large volume injection ; organophosphorus pesticides ; olive oil ; automation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The robustness of an automated on-line GPC-GC-FPD method for the determination of Organophosphorus (OP) Pesticides in olive oil has been significantly improved, now allowing a routine operation. The original GPC-GC transfer technique employed a loop type interface with an early vapor exit and co-solvent trapping. Shooting, caused by boiling delay and malfunctioning of the solvent vapor exit during the transfer of the 3 mL solvent fraction to the retention gap, resulted in insufficient focusing of the OP-pesticides. In this interfacing concept, the GPC fraction is introduced directly into the carrier gas stream during a certain time interval using the Dualchrom pressure- and flow regulation, resulting in a very stable transfer. The interface now basically corresponds to an on-column interface with flow regulation. Via a Pyrex glass door behind the GC-oven door it can be seen that the liquid flow is broken up into alternating gas-liquid segments by the carrier gas flow during transfer. This avoids shooting in the retention gap and broadens the temperature range for successful transfer. By using a smaller sized GPC column the solvent fraction transferred was reduced to 1.3 mL. Methyl acetate/cyclopentane and the co-solvent n-nonane were selected for their lower boiling points. The modified method is very robust and has been applied to the analysis of 28 different OP-pesticides in olive oil with an overall detection limit of 0.002 mg/kg. Routinely 24 h of unattended operation is possible with a cycle time of 75 min.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 69
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 29-32 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrochromatography ; electroosmotic flow ; frit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The formation of bubbles in capillary electrochromatography (CEC) is well documented: possible origins include Joule heating and variations in EOF velocity on passing from the stationary phase through the frit and into the open tube. Methods for the prevention of bubble formation are discussed which are confirmed by experimental results. Using frit lengths varying from 1 mm to 6 mm it is shown how frit length is directly related to the likelihood of bubble formation and how this is affected by applied voltage. It is shown that the change in applied voltage across a capillary affects the formation of bubbles and also that rebonding octadecylsilane (ODS) onto the silica frit after formation of the frit can minimize the formation of bubbles and how this effects the chromatography. A method is also described for increasing the robustness of silica capillaries using a column coupler along with modifications made to conventional capillary electrophoresis equipment to cater for CEC.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 70
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 39-42 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; CE ; chemical migration ; food contact plastics ; dihydroxybenzenes ; packaging ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A capillary electrophoresis method has been developed to determine 1,2-dihydroxybenzene and 1,3-dihydroxybenzene in the food simulants distilled water, 3% acetic acid, 15% ethanol, and olive oil. Both substances, used as monomers and additives to make food packaging plastics, could be analyzed within 15 min. The 1,4-dihydroxybenzene isomer was unretained and eluted with the electroosmotic flow, and so the CE method can give only a semi-quantitative estimate of this isomer if it is present as a migrant. The analytical recovery for the 1,2- and 1,3-isomers from spiked simulants was good at 87% to 98% except for 1,2-dihydroxybenzene which could only be recovered to the extent of 58% from olive oil. Calibration graphs were linear and the limit of detection for each substance was 0.6 mg/kg, which is well below migration limits for these substances. It is concluded that CE offers a rapid and reliable analysis for the control of migration from plastics intended for food contact which employ 1,2-dihydroxybenzene or 1,3-dihydroxybenzene during manufacture, and offers a screening method for 1,4-dihydroxybenzene migration.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 71
    ISSN: 0935-6304
    Schlagwort(e): Programmed temperature vaporization (PTV) ; GC-AED ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Programmed temperature vaporization injection (PTV) coupled to gas chromatography and atomic emission detector (AED) has been studied for large volume injection of gaseous samples. As examples of the effectiveness of the technique, the results of the analysis of a series of headspace samples of foods such as garlic and onion, and of landfill gases are presented. The volumes of gaseous samples reconcentrated varied from a few milliliters up to liters depending on analyte dilution, through focusing onto a sorbent trap, then rapid liberation into the GC-AED system by programmed thermal desorption. Despite the high carrier gas flow rates associated with direct PTV-GC, AED performance and sensitivity were unaffected. The detailed elemental information obtained from the PTV-GC-AED analyses was confirmed using a PTV coupled to a gas chromatograph with ion trap detector mass spectrometer as detector (PTV-GC-ITD/MS).
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 72
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 55-58 
    ISSN: 0935-6304
    Schlagwort(e): Micellar electrokinetic capillary chromatography ; sample dissolving solvent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 73
    ISSN: 0935-6304
    Schlagwort(e): Sulfobutyl ether-β-cyclodextrin ; micellar electrokinetic chromatography ; separation of regioisomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 74
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 70-72 
    ISSN: 0935-6304
    Schlagwort(e): HPLC ; di(2-ethylhexyl) phthalate ; migration ; foods and food simulants ; PVC cling film ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 75
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 79-82 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; thickeners ; monosaccharides ; PMMA capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Gelling agents based on polysaccharides have become extremely important in the food industry. As more and more products like soups and sauces have become available in lyophilized form, thickeners have to be added to give a controlled consistency to the finished meal. A capillary electrophoretic method has been developed to investigate the monosaccharide composition of hydrolyzed thickeners. 2-Aminoanthracene was used as a derivatization reagent to allow sensitive fluorescence detection. This system was applied to a set of standard thickeners as well as to food samples.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 76
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 83-88 
    ISSN: 0935-6304
    Schlagwort(e): Large volume injection ; programmed-temperature vaporizer ; organic acids ; phenols ; derivatization ; trimethylsulfonium hydroxide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The combination of on-line methylation using trimethylsulfonium hydroxide with large volume injection of 100 μL was evaluated for the analysis of organic acids and phenols in water. Solvent split injection was applied with complete evaporation of the solvent before analytes were transferred onto the GC column. Despite complete solvent removal, losses were very low compared to conventional splitless injection even for volatile acidic compounds such as propionic acid and phenol. This is explained by intermediate formation of low volatility trimethylsulfonium salts of the analytes which were held in the injector for long evaporation times of up to 10 min, if the evaporation temperature was as low as 10°C. Using a simple liquid/liquid extraction procedure, volatile fatty acids, dicarboxylic acids, benzoic acids and phenols could be detected in 5 mL of water at concentrations of 0.04-0.1 μmol/L with GC/MS in full scan mode. Lactic, pyruvic, and also malonic acids could only be detected at higher levels because of their limited extractability from water as well as their poorer methylation yields. The method provides an easy way to sensitively detect acidic compounds of medium to high volatility in water. It was applied for screening of organic acids and phenols in batch cultures of anaerobic bacteria of which one example is shown.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 77
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 97-102 
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; milk fat purity ; chemometrics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The adulteration of milk fat with foreign fat has been and still is a major concern in the dairy industry. Milk fat purity is currently evaluated by triglyceride analysis by using the Official EU method. The detection limit of the various vegetable and animal fats ranges between 4 and 6%. This research was carried out to verify whether it is possible to decrease the detection limits of beef tallow, which is the most widely used adulterating animal fat. For this purpose, determinations of diglycerides and 3,5-cholestadiene, together with the Official EU method, were applied both to several samples of pure milk fat and to mixtures of milk fat with different percentages of beef tallow. The best results were obtained combining the data deriving from the three determinations by multivariate statistical techniques; in particular, the statistical model obtained by the UNEQ technique seems to be able to decrease the detection limit of beef tallow from 5.2 to 2%. The diglyceride and 3,5-cholestadiene evaluation, combined with the Official EU method for triglycerides, can be usefully applied both to detect small additions of beef tallow and to demonstrate the adulteration of milk fat samples showing results close to the detection limit of the official method.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 78
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 109-115 
    ISSN: 0935-6304
    Schlagwort(e): Solid-phase microextraction ; capillary gas chromatography ; volatile polar compounds ; water matrix ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A method was developed for the analysis of volatile polar compounds in a water matrix using open cap vials Solid Phase Micro-Extraction (SPME) and Capillary Gas Chromatography (CGC). Both SPME techniques - direct sampling and headspace - were tested. Optimization of experimental conditions - exposure time, desorption time, with headspace SPME in addition the influence of the temperature and ionic strength of the sample solution on compound sorption, and finally GC response - were investigated. The analytes were extracted by directly immersing the 85 μm polyacrylate fiber in the aqueous sample or in the headspace. The linear range of the preconcentration process and the precision were examined. The amount of polar analytes sorbed on the fiber was determined and was found to be concentration dependent; it amounted to 0.014-0.64% in the concentration range of 0.00425-425 ppm studied in aqueous solution for direct sampling SPME and to 0.011-2.76% for solutions of concentration 0.0425-255 ppm for headspace SPME. The limits of determination were ascertained. Headspace SPME was applied to the analysis of real-life samples.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 79
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 126-128 
    ISSN: 0935-6304
    Schlagwort(e): Micellar electrokinetic chromatography ; capillary electrophoresis ; amines ; cyclodextrins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 80
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 123-125 
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography (GC) ; atomic emission detection (AED) ; human plasma ; drug monitoring ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 81
    ISSN: 0935-6304
    Schlagwort(e): Multidimensional Gas Chromatography ; orthogonal separations ; GC×GC ; comprehensive two-dimensional chromatography ; characterization of gasoline ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---In comprehensive two-dimensional gas chromatography (GC×GC), two capillary columns are connected in series through an interface known as a “thermal modulator”. This device transforms effluent from the first capillary column into a series of sharp injection-like chemical pulses suitable for high-speed chromatography on the second column. Dramatic increases in the resolving power, sensitivity, and speed of the gas chromatograph result. This paper describes the development of a robust and reliable thermal modulator for GC×GC.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 82
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 74-78 
    ISSN: 0935-6304
    Schlagwort(e): Polypeptides ; subcritical fluid chromatography ; supercritical fluid chromatography ; carbon dioxide ; additives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The effect of mobile phase modifier and additive on the chromatographic properties of various small polypeptides was explored under subcritical conditions. A polymeric column was used to separate various enkephalin analogs, bradykinin, and oxytocin using a carbon dioxide-based mobile phase with either an ethanol or a 2-methoxyethanol modifier. The role of the modifier was found to be secondary to that of the mobile phase additive. As progressively stronger acidic mobile phase additives were used, the peak profiles of the various polypeptides improved and retention decreased. Heptadecafluorooctanesulfonic acid was found to be the most useful additive for these types of solutes under near-critical conditions, while the potassium salt of heptadecafluorooctanesulfonic acid failed to elute any of the polypeptides. At low temperatures, pressure gradients with a carbon dioxide/ethanol/heptadecafluorooctanesulfonic acid ternary mobile phase produced reasonably good peak profiles with the polymeric column.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 83
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 89-92 
    ISSN: 0935-6304
    Schlagwort(e): Enantioselective gas chromatography ; heptakis(2,3-di-O-methyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin ; heptakis(2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin ; γ(δ)-thionolactones ; olfactometry ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The even numbered γ(δ)-thionolactones (C6-C12) were investigated, using heptakis(2,3-di-O-methyl-6-O-tert-butyldimethylsilyl)- and heptakis(2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin as chiral stationary phases in capillary gas chromatography. The odor characteristics of γ(δ)-thionolactone enantiomers were investigated by enantioselective gas chromatography/olfactometry.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 84
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 164-170 
    ISSN: 0935-6304
    Schlagwort(e): Food packaging ; functional barrier ; gas chromatography ; laminated paperboard ; mass spectrometry ; single sided headspace ; paperboard ; plastic film ; polymer film ; test cell ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A new cell for single sided headspace sampling has been developed for the analysis of volatile organic compounds from food packaging paperboard and laminated paperboard. The cell, which samples the volatile organic compounds over a selected surface, is useful for determining the barrier function of laminated paperboards with respect to volatile compounds. The analysis of volatile organic compounds is carried out by purge and trap capillary gas chromatography in combination with mass spectrometric detection and compound identification. The new sampling cell was constructed to facilitate specific analysis of organic compounds from only one side of a laminated paperboard. The construction and the operating principles of the new sampling device are described. The repeatability of the single sided headspace procedure was found to be quite good. Relative standard deviations of about 5-7% were obtained for the major compounds quantified in replicate headspace analyses of a laminated paperboard. The volatile compounds released from the inner side of a food packaging paperboard sample with different surface composition on the two sides were determined. The barrier function against volatile organic compounds of some laminated paperboards was investigated employing the new headspace cell.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 85
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 103-108 
    ISSN: 0935-6304
    Schlagwort(e): HPLC ; stationary phase ; copper-amine complex ; aromatic amines ; polyaromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Chromatographic silica (10 μm) was chemically modified with the silylating agent: [3-(2-aminoethyl)aminopropyl]trimethoxysilane (AEAPTS). The reaction product was characterized by elemental analysis and infrared and 13C and 29Si NMR spectra. The chemically modified silica was treated with Cu(II) in methanol medium. This cation was strongly adsorbed through complexation by the pendant ethylenediamine groups attached to the silica surface. The complex formed on the silica surface was shown to be stable in both aqueous and non-aqueous media. The aim of Cu(II) immobilization is to use this new material as a stationary phase in High Performance Liquid Chromatography (HPLC). Separations of synthetic mixtures of aromatic amines and of polyaromatic hydrocarbons were undertaken using 150×3.9 mm HPLC columns packed with the modified silica, with and without copper ions, to follow the influence of the cation on the chromatographic separation and to verify the efficiency of the new stationary phase for HPLC.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 86
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 116-118 
    ISSN: 0935-6304
    Schlagwort(e): Fast gas chromatography ; peak band broadening ; packed capillary columns ; narrow-bore columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 87
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 119-122 
    ISSN: 0935-6304
    Schlagwort(e): Fast gas chromatography ; multi-capillary column ; band broadening ; simulation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 88
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 129-130 
    ISSN: 0935-6304
    Schlagwort(e): GC-MS ; kava pyrones ; Alpinia zerumbet ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 89
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 135-143 
    ISSN: 0935-6304
    Schlagwort(e): Chromatographic separation techniques ; High Performance Liquid Chromatography (HPLC) ; Gel Permeation Chromatography (GPC) ; Supercritical Fluid Chromatography (SFC) ; Capillary HPLC ; Nuclear Magnetic Resonance (NMR) spectroscopy ; hyphenation of chromatography with NMR spectroscopy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The hyphenation of chromatographic separation techniques with NMR spectroscopy is one of the most powerful and time-saving methods for the separation and structural elucidation of unknown compounds and molecular compositions of mixtures. Most of the routinely used NMR flow-cells have detection volumes between 40-180 μL for conventional separations with analytical columns, and the newest designs employ detection volumes in the order of 200 nL for capillary separations. The low flow rates used in capillary chromatography permit the use of deuterated solvents. Unequivocal structural assignment of unknown chromatographic peaks is possible by two-dimensional stopped-flow capillary HPLC-NMR experiments.
    Zusätzliches Material: 14 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 90
    ISSN: 0935-6304
    Schlagwort(e): Conjugated linoleic acid (CLA) ; silver-ion high performance liquid chromatography (Ag+-HPLC) ; cheese ; analysis ; silver-ion chromatography ; tandem-column Ag+-HPLC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A commercial mixture of conjugated linoleic acid (CLA) isomers, reportedly consisting of six components, was recently resolved into 12 peaks attributed to CLA isomers using silver-ion high performance liquid chromatography (Ag+-HPLC). In this study, the coupling of two analytical silver-ion high performance liquid chromatography columns (tandem-column Ag+-HPLC) in series led to the enhanced resolution of CLA isomers. Many CLA isomers were baseline resolved and the pair 18 : 2 8,10 c/t and 18 : 2 7,9 c/t found in cheese products, was resolved for the first time. In this work, a similar commercial CLA mixture was separated into 16 peaks, while CLA isomers from cheese also gave rise to 16 peaks. As expected, the CLA isomers were separated into three geometric groups in the order trans,trans, cis/trans, and cis,cis. Semi-preparative Ag+-HPLC, followed by gas chromatography-mass spectroscopy of the dimethyloxazoline derivatives, was used to confirm the identity of the newly resolved positional CLA isomers. The double bond configuration of CLA isomers was established by gas chromatography-Fourier transform infrared spectroscopy. Two minor t,t CLA isomers found in cheese, presumably 18 : 2 t6t8 and 18 : 2 t13t15, were also separated. The CLA isomeric composition of 16 commercial cheese products was determined.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 91
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 159-163 
    ISSN: 0935-6304
    Schlagwort(e): Multi-dimensional chromatography ; LC-GC ; AED ; memory effects ; fossil fuel ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Conventional operation of the GC Atomic Emission Detector (AED) system involves backflushing of the microwave induced plasma (MIP) during the elution of small volumes of solvent from the GC column. When performing multi-dimensional, on-line LC-GC-AED, significantly larger solvent volumes are introduced into the system and must subsequently be removed. Thus solvent venting procedures are required and the backflushing of the plasma must be extended to facilitate solvent but not solute removal. This study demonstrates the significance of memory effects imparted upon the MIP of the AED if solvent venting is incomplete. Comparison of conventional GC-AED and multi-dimensional LC-GC-AED is made with respect to a fossil fuel sample.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 92
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 171-176 
    ISSN: 0935-6304
    Schlagwort(e): Micellar electrokinetic chromatography (MEKC) ; solid phase extraction (SPE) ; phenylurea(s) ; herbicide(s) ; monuron ; linuron ; diuron ; isoproturon ; monolinuron ; drinking water ; environmental water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The present paper describes the application of capillary electrophoresis in the micellar mode to the separation and quantitative determination of five phenylurea herbicides, viz. monuron, linuron, diuron, isoproturon, and monolinuron, in water samples. Using uncoated fused silica capillary and phosphate-borate buffer (pH 7.0) containing SDS, the five pesticides are resolved in less than 15 min and quantitatively determined by an ultraviolet detector at 244 nm. Method optimization and validation parameters are presented. Good linearity and repeatability were observed for all the compounds studied (correlation coefficients 0.999). The feasibility of the method developed was tested by simultaneous determination of these herbicides in environmental and drinking water samples at the minimum residue levels (MRLs) (0.1 μg/L) after solid-phase extraction (SPE) preconcentration procedure.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 93
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 181-182 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; microwave induced emission spectrometry ; speciation ; mercury ; SPME, headspace SPME ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 94
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; interfacing ; sample treatment ; serum ; solid-phase extraction ; sulfonamides ; urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 95
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 191-194 
    ISSN: 0935-6304
    Schlagwort(e): TLC/FID ; simple and double migration ; triangle of solvent selectivity ; lipochemical media ; fatty acid esters ; esterification ; transesterification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 96
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 201-204 
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography ; flame ionization detection ; solvent effects ; aqueous injection ; toluene analysis ; dioxane ; sample preparation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---A gas chromatographic method is presented for determining from 1 to 100 μg/mL of 1,4-dioxane in toluene with purities ranging from commercial to high-purity grades. This method relies on extracting 1,4-dioxane from toluene into water. The water extract is analyzed for 1,4-dioxane content by gas chromatography/flame ionization detection and a capillary column coated with a bonded polyethylene glycol stationary phase. Splitless injection is used to achieve a 1 μg/mL detection limit. Purging extracts with nitrogen after an initial analysis is suggested as an extract clean-up procedure and as a means to confirm the identification of 1,4-dioxane. However, for absolute identification of dioxane, gas chromatography/mass spectroscopy should be considered.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 97
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 213-216 
    ISSN: 0935-6304
    Schlagwort(e): Average velocity ; characteristic parameters ; flow rate ; high pressure drop ; low pressure drop ; outlet velocity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: When the column pressure drop is high, the average velocity of a carrier gas is proportional to the square root of the outlet velocity and the flow rate. Characteristic velocity, flow rate and pressure - the boundary conditions between low and high pressure drop regions - are introduced. Previously derived equations for average velocity vs. outlet velocity were modified to include the flow rate and to become more suitable for the separate studies of the low and high pressure drop regions.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 98
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 225-230 
    ISSN: 0935-6304
    Schlagwort(e): Green tea ; black tea ; composition ; stability ; capillary electrophoresis ; MEKC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: No abstract
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 99
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 235-238 
    ISSN: 0935-6304
    Schlagwort(e): Cryogenic modulation ; LMCS ; GC×GC ; multidimensional GC ; comprehensive gas chromatography ; petroleum analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: No abstract
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 100
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 242-244 
    ISSN: 0935-6304
    Schlagwort(e): Enantioselective gas chromatography ; 6-O-ethyl-2,3-O-pentyl-β-cyclodextrin ; essential oils ; carboxylic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---No abstract
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...