Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (7,033)
  • 1980-1984  (7,033)
  • 1982  (7,033)
  • Chemistry  (6,959)
  • pharmacokinetics
  • Nuclear reactions
Source
  • Articles: DFG German National Licenses  (7,033)
Material
Years
  • 1980-1984  (7,033)
Year
  • 1
    ISSN: 1432-0428
    Keywords: Glibenclamide ; pharmacokinetics ; high performance liquid chromatography ; plasma insulin ; blood glucose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A simple high performance liquid Chromatographic assay for the determination of plasma glibenclamide concentrations is described. This resolved glibenclamide from normal plasma constituents. The calibration curve of the assay was linear over the range 10–500 μg/1 and the minimum level of detection was 2 μg/1. Within-assay coefficients of variation were 11.6% (20 μg/1); 5.3% (50 μg/1); 6.8% (100 μg/1); between-assay coefficients of variation were 8.4% (20 μg/1); 4.7% (50 μg/1) and 7.4% (100 μg/1). The assay was used to study the pharmacokinetics of a 1 mg intravenous dose of glibenclamide in eight normal subjects. The mean half-life was found to be 1.47±0.42 h (SD) and no evidence for a non-linear β-phase or slowly equilibrating ‘deep’ compartment was found although this could not be rigorously excluded. The mean systemic drug clearance was 78±29 ml·h-1·kg-1 and the apparent volume of distribution in the β-phase was 155±44 ml/kg. The median time of maximum response of plasma immunoreactive insulin was 25 min and the median time of maximum blood glucose response was 53 min. No correlation could be found between the pharmacokinetics of glibenclamide and these responses in fasted normal individuals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0827
    Keywords: Bacterial amphophile ; Purification ; Chemistry ; Resorption ; Ca influx ; Cyclic AMP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The bone resorptive factor and amphipathic antigen (AcA) previously identified by us in preparations fromActinomyces viscosus have been partially purified, characterized chemically, and compared. They elute at the same location on chromatography with Ac 22. The fatty acid composition of AcA and the bone resorptive factor is the same. Some differences in carbohydrate composition are observed. TheActinomyces factor does not affect calcium influx or cyclic AMP in isolated bone cells. Therefore it is concluded that AcA stimulates resorption either by gaining entrance into bone cells or by way of a yet undetermined second messenger.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 373-377 
    ISSN: 1432-1041
    Keywords: propranolol ; sotalol ; thyrotoxicosis ; bioavailability ; serum tri-iodothyronine ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The elimination and bioavailability of two beta-blocking agents, propranolol and sotalol, were studied in 10 thyrotoxic patients, both before and after treatment with iodine-131. Each subject received in random order propranolol 160 mg and sotalol 160mg as single oral doses both while hyperthyroid and after euthyroidism had been achieved. The pharmacokinetics of sotalol was not affected by hyperthyroidism, whereas serum propranolol concentrations were significantly lower during hyperthyroidism than in the euthyroid state. During hyperthyroidism, the bioavailability of propranolol was significantly reduced (p〈0.05) and its clearance was increased (p〈0.005), whereas there was no difference in its serum t1/2. This indicates that the bioavailability of propranolol in hyperthyroidism is reduced by a mechanism which may depend on increased first-pass metabolism in the liver, or on an increased distribution volume of the drug. Both propranolol and sotalol caused a slight decrease in serum tri-iodothyronine concentration. As the effects of beta-blocking agents on the symptoms of hyperthyroidism are correlated with the serum concentration of the drugs, sotalol, with its long half-life and unaltered elimination in hyperthyroidism, has certain advantages over propranolol in the treatment of thyrotoxicosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 433-441 
    ISSN: 1432-1041
    Keywords: antipyrine ; antipyrine metabolites ; drug metabolism ; route of administration ; healthy volunteers ; urinary excretion ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of antipyrine in plasma and saliva, and urinary excretion of its major metabolites, were studied following i.v. and oral administration of antipyrine 500 mg to 6 healthy volunteers. Data from both plasma and saliva showed that the oral bioavailability of antipyrine given as an aqueous solution was complete. The saliva/plasma concentration ratio was constant with time from about 3 h onwards, with a mean value of 0.87 after oral and 0.91 after i.v. administration. It is concluded that the pharmacokinetic parameters of antipyrine can be satisfactorily established on the basis of salivary data, although the volume of distribution and clearance values are then slightly too high. After i.v. administration, 3.8±1.9% of the dose was excreted in urine as unchanged antipyrine in 48h, 24.9±6.3% as 4-hydroxyantipyrine, 16.5±3.2% as norantipyrine, 13.0±2.2% as 3-hydroxymethyl-antipyrine and 5.8±1.0% as 3-carboxy-antipyrine. No significant differences were observed following oral administration. The half-lives calculated from the linear part of the urinary excretion rate curves of the metabolites were about the same for oral and i.v. administration, and were of the same order of magnitude as the elimination half-life of parent drug in plasma and saliva. It is important for determination of the ultimate metabolite ratio that urine is collected for at least 36h, because there is a delay in the excretion of 3-hydroxymethyl-antipyrine in urine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 47-52 
    ISSN: 1432-1041
    Keywords: apnoea ; caffeine ; premature infants ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of caffeine was examined in 13 premature infants (gestational age 25–34 weeks, birth weight 920–2060 g, postnatal age 1–42 days) who received the drug for treatment of opnoea. Caffeine (1% aqueous solution) was given i.v. in single doses; guided by the clinical response infants received between one and seven (mean 2.6) doses of 15 mg/kg. Mean (± SE; range) Clb was extremely slow − 8.5 ml/kg/h (±0.4; 5.8–12.2), t1/2 was prolonged − 65.0 h (±3.7; 48.2–87.5 h) and Vd was 0.781/kg (±0.04; 0.47–1.01). No significant correlation was found between Clb, t1/2 and postnatal age in the whole group or in individual infants. Effective plasma concentrations varied over a wide range (12–36 µg/ml) and overlapped with subtherapeutic concentrations (⩽24 µg/ml). Single doses of 15 mg/kg i.v. or p.o. prevented apnoea in most cases, if necessary followed by additional doses. Monitoring the blood level of caffeine in infants receiving frequent repeated doses is necessary to prevent toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 327-330 
    ISSN: 1432-1041
    Keywords: bendroflumethiazide ; cantharides plasters ; blister fluid ; plasma levels ; pharmacokinetics ; compartmental analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of bendroflumethiazide (BFT) was investigated following the oral administration of 10 mg to 3 healthy volunteers. Each subject participated twice in the study. BFT was determined in plasma and cantharides blister fluid from 1/2 to 30 h post administration. Blister fluid was obtained from blisters 10–22 h old. Plasma levels were fitted to a tri-exponential equation and the concentration of the drug in the peripheral compartment was calculated from the microscopic rate constants. In 5 of 6 cases investigated, cantharides blister fluid levels paralleled the concentration of the drug in the peripheral compartment. The mean blister fluid levels exceeded the calculated concentration in Compartment 2 1.46 fold. In one case, the blister fluid level paralleled the plasma level. This subject clearly differed from the others as more than 10 h were required for blister formation in her. The results suggest that following the administration of BFT, cantharides blister fluid behaves as part of the peripheral compartment. The possible value of studying blister fluid levels in pharmacokinetic investigations is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 343-347 
    ISSN: 1432-1041
    Keywords: valproic acid ; fatty acids ; plasma protein binding ; pharmacokinetics ; drug metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effect of physiologic variations of free fatty acid levels on in vivo valproic acid plasma protein binding was studied in 6 healthy adult subjects. 14 blood samples were taken during a 12-h dosing interval at steady state while in a fed condition and also during a 27 h fast. Free fraction and total valproate concentration were determined by equilibrium dialysis and GLC, respectively. Free fatty acid levels were determined from both fresh samples and samples incubated at 37°C for 12 h, the latter in order to simulate equilibrium dialysis conditions. Fasting resulted in increased serum free fatty acid levels in all subjects, ranging from 34–182% (p〈0.01). Incubation also caused free fatty acid levels to rise, more so in fed samples (50–87%,p〈0.01) than in fasting samples (10–50%,p〈0.01). Fasting resulted in a 9% increase in the mean free fraction for all subjects combined (p〈0.01). Regression analysis of 180 sets of values for free fraction, total valproate concentration and free fatty acid level suggested that valproate concentration accounts for 17% and free fatty acid level for 37% of the variation in free fraction. Mean clearance was unchanged by fasting despite an increased free fraction suggesting decreased intrinsic clearance (i.e. decreased metabolism) of valproate under these conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 369-372 
    ISSN: 1432-1041
    Keywords: neuromuscular blockade ; pancuronium ; non-depolarizing neuromuscular blocking agent ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Pancuronium in bolus doses of 40 to 350 µg/kg was administered to surgical patients in order to evaluate the linearity of its pharmacokinetics. The profile of the plasma decay curve and of its urinary elimination were compared with reference to the administered dose. It was possible to superimpose the dose-normalized plasma decay-curves. The parameters of the two compartment-open model used to describe the pharmacokinetics of pancuronium were not influenced by the dose. The elimination half-life was 89±20 min and the plasma clearance was 1.84±0.38 ml/min/kg. The profiles of cumulative urinary excretion were also dose-independent. After 6 and 24 h, 57% and 69% of the administered dose, respectively, had been excreted in the urine. The results indicate that the pharmacokinetics of pancuronium is linear.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-1041
    Keywords: amitriptyline ; imipramine ; clomipramine ; antidepressant overdose ; clinical effects ; pharmacokinetics ; cardiotoxicity ; maprotiline ; doxepine ; nortriptyline ; opipramol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Twenty-nine cases of self-poisoning with antidepressants (amitriptyline, imipramine, clomipramine, maprotiline, doxepine, nortriptyline, opipramol) were examined by frequent observation of CNS effects, heart rate, blood pressure and standard ECG, 24 h-ECG-monitoring, measurement of systolic time intervals, EEG recordings and frequent measurement of serum levels of antidepressants and primary metabolites. None of the patients died. Maximum total serum antidepressant level (parent compound + desmethyl metabolite) ranged from 20 to 2200 µg/l, with concentrations above 500 µg/l in 11 cases. The serum amitriptyline concentration remained high for 3–4 days in some of the severely intoxicated patients and the decay curves were compatible with partly saturated elimination. A degree of unconsciousness and the occurrence of excitation and hallucinations were generally seen in cases with total serum antidepressant levels above 500 µg/l. Grand mal seizures occurred more frequently at high antidepressant levels, but could not be predicted from the EEG recordings. Increased heart rate and prolonged QRS- and QTc-intervals were significantly correlated with the total serum antidpressant level. 24 h-ECG-monitoring revealed no serious arrhythmias or instances of heart block. Hypotension was only seen initially in few patients. Systolic time interval measurements showed changes suggesting impaired myocardial performance (elevated PEP/LVET ratio) at intermediate (60–500 µg/l) but not high (〉500 µg/l) total serum antidepressant levels. Measurement of serum concentration in antidepressant intoxication is important for identification of patients with high serum levels and the corresponding risk of developing toxic reactions, and to exclude patients with a low concentration who do not require intensive observation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 349-351 
    ISSN: 1432-1041
    Keywords: indomethazine ; rheumatoid arthritis ; pharmacokinetics ; tolerance ; side effects ; slow-release tablets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics, efficacy and tolerance of a new formulation of slow-release indomethacin tablet were compared with those of a conventional indomethacin capsule in 30 patients with rheumatoid arthritis. The slow-release tablet was absorbed more slowly than the capsule (tmax 3.7 h and 〈 2 h, respectively) and produced more even serum drug levels in 10 subjects. Side-effects, especially dizziness and diarrhoea, were less frequent after the slow-release tablet than during the capsule period.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 287-291 
    ISSN: 1432-1041
    Keywords: tolmesoxide ; hypertension ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Tolmesoxide is a new, direct-acting vasodilator drug for use in the management of both hypertension and cardiac failure. In 6 essential hypertensives inadequately controlled by combined β-blocker and diuretic therapy (average supine blood pressure 178/103 mm Hg) the addition of tolmesoxide (300–900 mg daily) was associated with a significant improvement in blood pressure control (average supine blood pressure 161/89 mmHg). The effect of food on the pharmacokinetics and pharmacodynamics of tolmesoxide have also been studied because, particularly at higher doses, the drug has been associated with upper gastrointestinal upset and it has been empirically recommended that it be taken with food. The blood pressure and heart rate responses were not significantly different when tolmesoxide was taken fasting or with food. Food resulted in a significant reduction in the peak plasma tolmesoxide concentration (2.14 µg/ml compared to 2.97 µg/ml) and a significant increase in the time to reach peak plasma concentration (1.67 h compared to 0.63 h). Although there was no impairment of its hypotensive effect, food significantly altered the pharmacokinetics of tolmesoxide and may therefore be useful in reducing the gastrointestinal disturbance associated with its use. In the treatment of inadequately controlled hypertension, tolmesoxide has a limited role as an alternative vasodilator.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 307-310 
    ISSN: 1432-1041
    Keywords: piretanide ; renal failure ; high dose ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The kinetics of piretanide was studied in patients with renal failure. After oral administration of a high dose of piretanide (96 mg), the pharmacokinetic parameters were: elimination rate constant 0.346±0.072 h−1, half life 2.00±0.35 h, and total plasma clearance 119.55±35.90 ml · min−1. Compared to the values obtained in adults with normal renal function, these results show a decrease in total plasma clearance, but conservation of the metabolic clearance which amounts to 45% of the total clearance in the healthy adult.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 325-330 
    ISSN: 1432-1041
    Keywords: cimetidine ; renal failure ; cimetidine sulphoxide ; pharmacokinetics ; haemodialysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary A single intravenous dose of cimetidine 200mg was administered to 6 patients with severe chronic renal failure one hour prior to haemodialysis. The plasma concentrations of cimetidine and its sulphoxide metabolite at the start of haemodialysis were 2.74±0.12 and 0.76±0.08 µg/ml, and after dialysis for 4h 1.08±0.10 and 0.51±0.08 µg/ml, respectively (mean ± SE). The average haemodialysis clearance (ClHDa) of cimetidine during dialysis was 46–92ml/min at a dialysate flow rate of 320ml/min and blood flow rates in the 6 patients between 160–240ml/min. The mean ClHDa of the sulphoxide metabolite was 44% higher than that of cimetidine, and ranged between 49–148ml/min. During haemodialysis the mean plasma elimination half-life (t1/2) of cimetidine was 3.24h (range 2.08–5.08) and of the sulphoxide metabolite 9.49h (range 4.70–14.39). There was a significant relationship between the elimination rate constant (β) and ClHDa of the sulphoxide metabolite (p〈0.01), but no such relationship was found between β and ClHDa of cimetidine. However, there was a tendency to a relationship between β of cimetidine and the capacity to metabolise the drug, expressed as the ratio between the plasma concentrations of the sulphoxide metabolite and cimetidine after dialysis for 4h. These ratios ranged between 0.23–0.76, and the lowest ratio was seen in the patient with the lowest β value of cimetidine. Thus, the large variations in the plained by differences in their capacity to metabolise the drug. The mean total amount of cimetidine eliminated during dialysis was 27.3mg (range 17.9–31.8), which was 9.0–15.9% of the given dose. Between 12.2–21.2mg (mean 15.3) of the sulphoxide metabolite was eliminated in the dialysate. Major adjustment of the dose of cimetidine on days of dialysis is not necessary.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 351-354 
    ISSN: 1432-1041
    Keywords: lithium ; plasma level decay curve ; elimination ; pharmacokinetics ; psychiatric patients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Chronic treatment with conventional lithium carbonate was interrupted in a selected group of 40 psychiatric patients of mixed sex and race. All patients had normal renal function. Serum samples were taken 12, 24, 36 and 48 h after the last dose and lithium was assayed by atomic absorption spectrophotometry. Decay rates calculated for the 12–24 h and 36–48 h periods yielded different values. This was ascribed to the presence of an incomplete redistribution phase during the earlier period. The distribution of elimination rates determined during the later period gave a more symmetrical spread and approximated a normal distribution. The mode, median, mean and standard deviation of the lithium elimination half-lives were 12.5, 14, 18.2 and 7.3 h and 22.5, 24.5, 29.8 and 10.1 h for the two periods, respectively. The results contrast sharply with another report of the distribution spread of elimination half-lives in a much larger sample. The current values have implications for dosage prediction, serum level monitoring and dosage formulation, especially sustained-release preparations. The evidence was against the possibility that some individuals ‘retain’ lithium.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 397-402 
    ISSN: 1432-1041
    Keywords: ergotamine ; migraine ; radioimmunoassay ; clinical effects ; adverse effects ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The systemic availability of ergotamine after a single therapeutic oral or rectal dose was studied using a radioimmunoassay during the headachefree state in 24 patients suffering from migraine. Plasma concentrations of the drug were compared with anamnestic data about its clinical effects in the same patients. Among 12 patients with a good therapeutic response to medication, the mean plasma ergotamine levels stayed in the range 0.20 to 0.50 ng/ml for 6h. Their mean plasma levels at 30 min (0.33ng/ml) and 1h (0.40ng/ml) were significantly higher than those (0.06 and 0.08ng/ml, respectively) in 9 patients with only a moderate therapeutic response. In 9 patients with a moderate and 3 with a poor therapeutic response, the mean plasma level generally stayed below 0.10ng/ml. The mean peak concentrations in moderate (0.13 ng/ml) and poor (0.11ng/ml) responders appeared later (at 3h) than in good responders (at 1h). Side effects of the medication appeared to be associated with relatively low plasma levels of ergotamine and also with delayed maximum plasma concentrations of the drug. The present results suggest that the time of the maximum plasma drug level is an important determinant of the clinical effects of ergotamine, and that a good therapeutic response may be expected if a plasma ergotamine level of 0.20ng/ml or more is achieved within 1 hour after oral or rectal administration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 421-425 
    ISSN: 1432-1041
    Keywords: benzodiazepine ; lormetazepam ; lormetazepam glucuronide ; transfer to milk ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The concentrations of lormetazepam and its glucuronide in plasma and milk were determined during administration of 10 daily doses of lormetazepam 2 mg (2 tablets of NOCTAMID® - 1) to five mothers delivered by Caesarian section. Their babies were breast-fed throughout the study, and the plasma levels of lormetazepam and its glucuronide were determined three times in the babies. At 12 and 24h after administration, the plasma level of lormetazepam was about 3.5 ng/ml and 1.8 ng/ml in mothers, and below 0.09 ng/ml in the children. In milk the lormetazepam concentration was below 0.2 ng/ml. The plasma level of glucuronide varied between 24 ng/ml at 12h and 11 ng/ml 24h after administration. Almost no accumulation of unchanged lormetazepam was observed (factor: 1.3). The ratio of the levels of lormetazepam in milk and plasma was estimated to be below 0.06, and for the glucuronide the ratio was 0.04. The quantity of free and conjugated active ingredient transferred to the children via breast milk was calculated to be at most 100 ng/kg, corresponding to 0.35% of the maternal dose, which is regarded as tolerable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 499-504 
    ISSN: 1432-1041
    Keywords: gentamicin ; malnutrition ; pharmacokinetics ; infant
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of gentamicin was investigated in normal and malnourished infants aged 4–10 months. Neither mean “elimination” nor “distribution half life” show any difference, but the volume of distribution was higher in malnourished babies, probably due to their larger total body water.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 423-428 
    ISSN: 1432-1041
    Keywords: pindolol ; renal failure ; metabolism ; pharmacokinetics ; 14C-pindolol ; blood metabolites ; urinary metabolites
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Increased metabolism of pindolol in renal impairment has previously been suggested by pharmacokinetic calculations. The present study was a pharmacokinetic and metabolic investigation in 7 patients with severe renal impairment (endogeneous creatinine clearance below 5 ml/min). All the patients received pindolol 5 mg t.d.s. 5 days. On the sixth day, after an overnight fast, 14C-pindolol 5 mg was given orally as a solution to drink. Blood samples were taken for up to 72 h and urine was collected at intervals up to 96 h for measurement of unchanged pindolol by a fluorimetric method and total radioactivity by liquid scintillation counting. Metabolites in blood and urine were analysed after separation by HPLC. It was found that the plasma levels following a single dose of 14C-pindolol were similar to those observed in healthy volunteers, but the elimination half-life was slightly increased up to 11.5 h. The observed steady state plasma concentrations of pindolol were twice as high but they are still in the therapeutic range of 10 to 100 ng/ml. Therefore, the dose of pindolol could have been reduced by a factor 2, but the reduction was not essential. No active metabolite of pindolol was found in plasma or urine, but elimination of the metabolites was decreased. The elimination half-life following multiple doses was prolonged compared to normal and it was quite comparable to that found for the pharmacodynamic half-life in renal patients. The discrepancy between the present findings and the previous results for metabolism and pharmacodynamic half-life was probably due to the sensitivity of the fluorimetric assay of pindolol.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 417-422 
    ISSN: 1432-1041
    Keywords: theophylline ; aminophylline ; obstructive airways disease ; short-term i.v. infusion ; log-normal distribution ; pharmacokinetics ; serum concentrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Serum theophylline concentrations after intravenous administration of a new short-term infusion (Euphyllin® Kurzzeitinfusion) were measured in 50 out-patients with chronic obstructive airways disease (COAD). An intravenous infusion of theophylline ethylenediamine 480 mg (corresponding to approximately 350 mg anhydrous theophylline) in 50 ml isotonic solution was given in 20 min. Blood samples were taken beforehand and 25 to 30 min and 1, 3 and 6 h after starting the infusion. 86% of the patients had a one-hour serum level in the therapeutic range of 8–20 mg/l, and 2 h later, this was true of 64% of the patients. The short-term infusion was well tolerated, even in cases with unknown high pre-infusion serum levels. Pertinent pharmacokinetic parameters were determined, such as total body clearance, apparent volume of distribution, and half-life of elimination. Geometric mean and 95%-confidence limits, derived from the log-normal distribution of these parameters, were: Cl=0.044 (0.018–0.109) l/h/kg ideal body weight, Vd=0.451 (0.258–0.789) l/kg ideal body weight, and t1/2(el)=7.1 (2.6–19.1) h.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 235-240 
    ISSN: 1432-1041
    Keywords: ergotamine ; pharmacokinetics ; migraine ; plasma drug levels ; i.v. administration ; i.m. administration ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The kinetics of ergotamine has been investigated in migrainous patients using a new, specific, sensitive HPLC assay (detection limit 100 pg/ml plasma). 10 patients were given ergotamine tartrate 0.5 mg i.v. and 5 of them received the same dose i.m. 2–3 weeks later. Blood samples were collected for up to 54 h following administration and the plasma concentration were analysed. After intravenous administration the plasma ergotamine declined rapidly, with an initial distribution half-life of 3 min followed by a mean terminal half-life of 1.86 h (range 90–155 min). The mean total plasma clearance was 11.0 ml kg−1 min−1, and the volume of distribution (Vdβ ) was 1847.6 ml kg−1. Individual t1/2β showed a positive linear correlation with the individual Vdβ . The intramuscular absorption of ergotamine was rapid and maximum plasma levels were usually obtained 10 min following administration. The biological availability was incomplete and variable at 46.6% (range 28.3–60.8%).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 249-252 
    ISSN: 1432-1041
    Keywords: mecillinam ; bacmecillinam ; pivmecillinam ; pharmacokinetics ; pro-drug ; healthy volunteers ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of bacmecillinam and pivmecillinam were studied in healthy fasting volunteers given tablets in a cross-over, randomized order. The mean (±SD) peak levels of plasma mecillinam were 1.43±0.34, 2.73±0.43, and 4.62±1.41 mg/l after bacmecillinam 100, 200, and 400 mg and 2.38±0.65 mg/l after pivmecillinam 400 mg. The corresponding areas under plasma Vs time curves (AUC) were 2.21±0.19, 3.99±0.63, and 7.74±1.38 mg·h·l−1 for bacmecillinam and 5.35±0.93 mg·h·l−1 for pivmecillinam. The elimination half-lives were 0.8–1.1h for bacmecillinam and 0.7h for pivmecillinam. The 12 h urinary recovery of unchanged mecillinam after the 400 mg doses was 41% for bacmecillinam and 30% for pivmecillinam. The 400 mg dose of bacmecillinam gave a significantly higher plasma peak (p〈0.001), AUC (p〈0.001) and urinary recovery (p〈0.001) than did pivmecillinam 400 mg. The plasma peaks appeared earlier and the rate of absorption was higher after bacmecillinam than after pivmecillinam (p〈0.05). In conclusion, bacmecillinam had a better bioavailability than pivmecillinam in the tablet formulations studied. The AUC increased linearly with increasing doses of bacmecillinam.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1432-1041
    Keywords: L-threo-3,4-dihydroxyphenylserine ; familial amyloid polyneuropathy ; pharmacokinetics ; norepinephrine ; pressor response
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of oralL-threo-3,4-dihydroxyphenylserine (L-threo-DOPS) was studied in 7 normal subjects and 7 patients with familial amyloid polyneuropathy. Each person swallowed a single 300 mg dose in the fasting state, andL-threo-DOPS in plasma and urine was determined by high performance liquid chromatography with an electrochemical detector after separation on a boric acid gel column.L-threo-DOPS was slowly absorbed by normal subjects; the maximum plasma concentration occurred 3 h after administration and 20% of the oral dose was recovered unchanged in the urine within 12 h. It induced a substantial elevation of plasma norepinephrine levels, the peak being attained at 5 h, but without any change in blood pressure. In the patients, the absorption and metabolism ofL-threo-DOPS were delayed, and a prolonged pressor response was observed, with a peak after 8 h. It was concluded that the effects on plasma norepinephrine and blood pressure of oralL-threo-DOPS were essentially equal to those of twice as large a dose ofDl-threo-DOPS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 501-504 
    ISSN: 1432-1041
    Keywords: cimetidine ; uraemia ; dosing regimen ; prediction ; computer program ; old age ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Using a recently developed computer program based on a correlation between methods to predict the elimination half-life and apparent volume of distribution of cimetidine and actual data from patients, ideal dosage regimens were generated for patients with renal impairment and for geriatric patients, together with the corresponding maximum and minimum steady state concentrations. Using the ideal dosage regimens, practical regimens with feasible dosing intervals of 6, 8 and 12 h were computed, which should result in therapeutic concentrations of 0.4 to 1.3 µg/ml. For uraemic patients and geriatric patients above the age of 75 years it would be desirable to have an additional oral 100 mg dosage form.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 161-169 
    ISSN: 1432-1041
    Keywords: mebendazole ; hydatid disease ; Echinococcus granulosus ; hepatic disease ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The plasma concentrations of mebendazole and its metabolites have been monitored in twelve patients after receiving a 10 mg/kg dose for cystic hydatid disease. The mebendazole plasma concentration-time profiles differed considerably between patients; elimination half-lives ranged from 2.8–9.0 h, time to peak plasma concentration after dosing ranged from 1.5–7.25 h and peak plasma concentrations ranged from 17.5 to 500 ng/ml. The mean peak plasma concentration of mebendazole after an initial dose (69.5 ng/ml) was lower than found in patients during chronic therapy (137.4 ng/ml). The plasma AUCTs for the major metabolites of mebendazole (methyl 5-(α-hydroxybenzyl)-2-benzimidazole carbamate and 2-amino-5 benzoylbenzimidazole) were about five times the plasma AUCT found for mebendazole in patients on chronic therapy. It is suggested that the slower clearance of these polar metabolites relative to mebendazole results from enterohepatic recycling. Since mebendazole is also highly plasma protein bound, caution should be observed in administering mebendazole to patients with liver disease. Concentrations of mebendazole found in the tissue and cyst material collected from two patients during surgery ranged from 59.5 to 206.6 ng/g wet weight.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 265-272 
    ISSN: 1432-1041
    Keywords: pharmacokinetics ; variation of absorption ratios ; bioavailability ; dissection of variation due to absorption and intermediate processes ; oral drug application
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Differences in the plasma concentrations of drugs after oral administration are caused by two main factors: variation in absorption ratios and in the distribution processes in the body. A new method for the dissection of both types of factors is discussed. The method uses a reference regression of the AUC-values to the corresponding values after intravenous infusion of graded doses. The reference regression is estimated from an appropriate trial. Deviation of the determined AUC-values from the regression curve afford an estimate of the residual variance due to varying distribution volumes or similar random biological effects. For the estimation of absorption ratios after oral administration the drug is given orally to another sample of subjects and their AUC-values are calculated. The deviation of these AUC values due to the above mentioned random effects are simulated using the residual variance of the reference regression, and are subtracted from the observed AUC-values. Then, the differences in the corresponding absorbed doses are transformed by inverting the reference regression. From these doses the empirical distribution function and statistical parameters (e.g. quantiles) are determined. The method has the advantage that no restrictive assumptions are required, such as first order processes, dose linearity, homogeneity of variance or normal distribution of absorption ratios. Its applicability to substances with qualitative differences in their pharmacokinetics is demonstrated by appropriate examples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 435-440 
    ISSN: 1432-1041
    Keywords: erythromycin ; haemodialysis ; dosage adjustment ; pharmacokinetics ; protein-binding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Erythromycin kinetics were studied in 17 patients with end stage renal failure treated with maintenance haemodialysis and 9 normal volunteers to discover if dialysis patients needed a modified dose. The elimination half life in dialysis patients (on dialysis days) was similar to that reported in normal subjects. Only small amounts of drug appeared in the dialysate, no patient loosing more than 9 mg in one dialysis. Both patients and volunteers had similar plasma concentrations 8 h after the end of a 5-day course. Protein-binding did not change significantly during dialysis and was similar to that reported in normal subjects. We conclude that dialysis patients requiring 1.5 g of erythromycin stearate daily or less can be given normal doses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 303-306 
    ISSN: 1432-1041
    Keywords: furosemide ; renal failure ; haemodialysis ; pharmacokinetics ; children ; dosage schedule
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Furosemide was measured by gas-liquid chromatography in blood and dialysis fluid from 7 children with chronic renal failure, undergoing regular haemodialysis. It was administered chronically, in two or three daily doses (4.2–9.4 mg/kg). Two children received 1 mg/kg intravenously for determination of the pharmacokinetics. The half-life was longer than in adults and in anephric patients on haemodialysis. Systemic and renal clearance were also much lower. Plasma protein binding in 2 out of 6 cases was reduced as campared to normal adults. The data do not suggest any need to modify the present dosage schedule despite the 4–5 fold increase in the half-life of furosemide. The contribution of haemodialysis to drug clearance was minimal, and accounted for less than 10% of the total clearance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 331-334 
    ISSN: 1432-1041
    Keywords: diclofenac sodium ; rheumatoid disease ; healthy subjects ; serum albumin ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Pharmacokinetic data for diclofenac sodium has been well established in healthy volunteers, whereas in patients with rheumatoid arthritis very little information is available in the literature. A single oral dose of enteric-coated diclofenac sodium was given to 10 patients with active rheumatoid disease, adopting the same procedures used for a group of 10 healthy volunteers in whom pharmacokinetic data was already available. Plasma specimens were collected over a period of 8h following administration and concentrations of diclofenac determined by GLC. Resulting plasma concentration curves were similar to those obtained in the healthy subjects in that areas under curves and terminal half-lives were comparable. However, peak concentrations of diclofenac were significantly reduced in the rheumatoid patients. The lower peak concentrations were correlated with the lower serum albumin levels in the patients which are associated with active rheumatoid disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 343-350 
    ISSN: 1432-1041
    Keywords: orphenadrine ; single dose ; multiple doses ; bioavailability ; pharmacokinetics ; N-demethylorphenadrine ; metabolism ; dog ; man
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Plasma concentrations of orphenadrine were measured by a specific gaschromatographic method in 5 healthy male volunteers after a single oral dose of orphenadrine hydrochloride 100mg. The single dose pharmacokinetic profile of orphenadrine was evaluated from these data. The elimination half-life ranged from 13.2–20.1 h after the commercial tablet formulation. Plasma concentrations, determined in volunteers and patients under different conditions of repeated oral administration of the same formulation of orphenadrine hydrochloride exceeded the theoretical values, predicted from the single dose pharmacokinetics, by a factor 2 to 3. The elimination half-lives after discontinuation of treatment showed a 2 to 3-fold increase over the single dose values. This demonstrates a clear discrepancy between the multiple and single dose pharmacokinetics of orphenadrine. Experiments in dogs suggested competition for biotransformation between orphenadrine and its metabolite N-demethylorphenadrine. Product inhibition of this type could explain the observed discrepancy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 77-84 
    ISSN: 1432-1041
    Keywords: allopurinol ; oxipurinol ; benzbromarone ; hydrochlorothiazide ; pharmacokinetics ; bioavailability ; interaction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary An high-pressure liquid chromatographic method was used to measure allopurinol and oxipurinol in plasma and urine in 6 healthy volunteers after a single intravenous or oral dose of allopurinol. The influence of coadministrated benzbromarone and hydrochlorothiazide on the pharmacokinetics of allopurinol and oxipurinol was also investigated. After intravenous injection of allopurinol 300 mg the plasma disappearance was biexponential, with a mean distribution half-life of 2.32±1.08 min $$(\bar x \pm SD)$$ and an elimination half-life of 47.8±10.6 min. The total clearance of allopurinol was 11.37±2.70 ml/min/kg, whereas its renal clearance was only 1.73±0.79 ml/min/kg. Oxipurinol disappeared monoexponentially from plasma ith a mean half-life of 12.2±2.6 h. Its renal clearance was 0.42±0.091 ml/min/kg. After oral administration of allopurinol 300 mg the peak plasma concentration of 2.1±0.6 µg/ml (1.5×10−5 M) was reached within 30 to 120 min. The peak level of oxipurinol of 5.8±1.5 µg/ml (3.8×10−5 M) was found within 2 to 5 h after intravenous and oral allopurinol. The bioavailability of oral allopurinol computed from plasma data was 90.4±8.7%. The total recovery from urine was 77% (allopurinol 8%, oxipurinol 69%) after oral and 88% after i.v. administration. It was concluded that about 10% of the oral dose was not absorbed and that 12% was eliminated by an unknown mechanism, presumably as riboside. The pharmacokinetics of allopurinol and oxipurinol were not significantly influenced by coadministration of benzbromarone or hydrochlorothiazide.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 515-521 
    ISSN: 1432-1041
    Keywords: tienilic acid ; uricosuria ; pharmacokinetics ; pharmacodynamics ; uric acid ; diuretic ; plasma level assay
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary A simple and reliable HPLC method for the determination of tienilic acid ((TA) Selacryn®, Selcryn®, Diflurex®, Ticrynafen®) and its alcoholic metabolite in plasma and urine has been developed. In 8 healthy adult volunteers the plasma and urinary levels of tienilic acid and its alcoholic metabolite, and plasma and urinary levels of sodium, creatinine and uric acid were measured after oral administration of tienilic acid 250 mg. The pharmacokinetic parameters found differed only slightly from those reported in the literature, as there was faster absorption and a shorter half-life. TA is probably excreted by a saturable renal tubular transport mechanism. The pharmacodynamic effects of tienilic acid developed quickly, the uricosuric effect being very impressive and the natriuretic effect moderate. These effects disappeared in about 8 h. An inverse relationship was found between the starting plasma uric acid level in an individual and the maximal uric acid clearance — the higher the plasma uric acid level, the lower was the maximum effect. Plasma tienilic acid level and natriuretic effect were correlative within individuals and intra-individually (p〈0.05). Urinary tienilic acid level and natriuretic effect were correlated, too (p〈0.05 top〈0.001), but only intraindividually. No correlation between drug level and uricosuric effect was found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 535-539 
    ISSN: 1432-1041
    Keywords: noscapine ; pharmacokinetics ; absorption ; bioavailability ; intravenous application ; oral application ; ion exchange resin tablet
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Noscapine was administred to five healthy volunteers in a randomized crossover design, as an intravenous infusion of 66 mg, and as an oral 150 mg dose of either rapidly dissolving tablets or a tablet containing ion exchange resin-bound noscapine. After i.v. administration, the disposition of noscapine was bi-exponential with an elimination half-life of 2.6 h; the total plasma clearance was 22 ml/min/kg and the volume of distribution (Vdarea) was 4.7 l/kg. The absolute oral bioavailability was 30%, with a 3.6-fold interindividual variation. There was no pharmacokinetic evidence to support a prolonged action of the ion exchange resin tablet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 155-160 
    ISSN: 1432-1041
    Keywords: amikacin ; pharmacokinetics ; development ; neonate ; infant ; child
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The disposition kinetics of a single i.v. dose of amikacin was studied in 6 neonates (6–25 days old), 10 infants (4–18 months) and 8 young children (3–11 years). There was a progressive change in the distribution and elimination kinetics during development. The distribution coefficient of the antibiotic averaged of 0.429, 0.320 and 0.210 l/kg in the newborns, infants and young children, respectively and serum half-life (t1/2 β) in these three groups averaged 2.812, 1.803 and 1.196 h, respectively. Significant differences in certain pharmacokinetic parameters were found between the values in paediatric patients and in adults receiving the same dose. A linear relationship was established between the distribution volume of the antibiotic and the weight of the patients, as defined by the following equation: $${\text{Vd}}_{{\text{ss}}} \left( 1 \right) = 0.976 + 1.140 \cdot {\text{TBW}}\left( {{\text{kg}}} \right);r = 0.954$$ The results suggest that a regimen of very frequent administrations should be employed in infants and young children in order to maintain a therapeutic level throughout treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 267-270 
    ISSN: 1432-1041
    Keywords: terodiline ; human volunteers ; pharmacokinetics ; serum clearance ; bioavailability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of terodiline HCl was studied in nine healthy volunteers given 12.5 mg i.v. and p.o. or 20 mg i.v. and 25 mg p.o. on two different occasions. The serum concentrations were measured by gas chromatography — mass spectrometry, using deuterated terodiline HCl as the internal standard. After i.v. administration the kinetics could be described by a two-compartment model with a mean distribution half life of 0.3 h and a mean elimination half life of 63 h. The serum clearance and apparent volume of distribution varied about 4-fold with mean values of 4.8 l/h and 417 l, respectively. After oral administration, the mean half life of absorption was 0.7 h and that of elimination 65 h. The absolute bioavailability varied between 64% and 105% with a mean of 92%. The long serum half life of terodiline should permit its once daily administration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 523-527 
    ISSN: 1432-1041
    Keywords: endralazine ; acetylator phenotype ; hydralazine ; pharmacokinetics ; plasma concentrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Five and 10 mg single oral doses of a new vasodilator antihypertensive, endralazine (E) were given on separate occasions to 17 normal male volunteers (8 slow, 7 heterozygous fast and 2 homozygous fast acetylators). The homozygous fast acetylators were excluded from statistical comparisons. Only small differences were observed in the pharmacokinetics of E between the phenotypes and there was no evidence of non-linearity at the 2 dose levels studied. Terminal half-lives ranged from 2.59 to 7.14 h with a mean of 4.30±1.08 h for the 5 mg dose and 4.25±1.09 h for the 10 mg dose. There was no significant difference in half-lives between slow and heterozygous fast acetylators. The mean area under the plasma level-time curve (AUC 0 ∞ ) was 18.2% lower (p〈0.05) in the heterozygous fast acetylators than in the slow acetylators following the 5 mg dose and 11.0% lower (p〉0.05) following the 10 mg dose. Extremely rapid absorption of the drug precluded accurate estimation of absorption rates. The AUC 0 ∞ of the acetylation metabolite (methyltriazoloendralazine) was small compared to that of E although higher in the heterozygous fast acetylators than in the slow acetylators (p〈0.01).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 335-341 
    ISSN: 1432-1041
    Keywords: phenylephrine ; pharmacokinetics ; bioavailability ; first-pass metabolism ; phenolic conjugates ; m-hydroxymandelic acid ; intravenous ; oral
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary 7-3H-phenylephrine was given to 15 volunteers by a short-infusionn=4) or p.o. (10 volunteers, 1 patient with porto-caval anastomosis). Analysis of serum for free3H-phenylephrine and fractionation of urinary radioactivity was performed by ion-exchange and thin-layer chromatography. As almost the same3H-activity was excreted in urine after i.v. and p.o. administration, 86% and 80% of the dose respectively, complete enteral absorption can be assumed. A considerable difference was seen in the fraction of free phenylephrine, i.v. 16% of the dose versus p.o. 2.6%, which suggested reduced bioavailability. This was confirmed by comparison of the areas under the serum curve, which showed a bioavailability factor of 0.38. The result for the patient with porto-caval anastomosis was comparable to that in the normal volunteers. The biological half-life of 2 to 3h was comparable to that of structurally related amines, as were the total clearance of 2 1/h, and the volume of distribution of 340l. Metabolism to phenolic conjugates mainly after oral ingestion, and tom-hydroxymandelic acid after i.v. injection, again demonstrated thatm-hydroxylated amines are predominantly conjugated during the “first-pass” metabolism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 337-342 
    ISSN: 1432-1041
    Keywords: methadone ; pharmacokinetics ; urinary pH ; RBC level ; saliary level ; mass fragmentography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The influence of urinary pH on the acute disposition of methadone in man was studied in five healthy volunteers. A cross-over experiment was performed in each subject. In the first experiment the subjects were treated with ammonium chloride (urinary pH ≈ 5.2) and in the other the urine was made alkaline (pH ≈ 7.8) by treatment with sodium hydrogen carbonate. d, 1-Methadone-HCl 10 mg (M) was administered intramuscularly on each occasion and blood, saliva and urine levels of M were determined by mass fragmentography. Plasma half-lives, volumes of distribution and body clearances of M were calculated in both experiments. The plasma half-lives in the β-phase were 19.5±3.6 h (acidic urine) and 42.1±8.8 h (alkaline urine), respectively (p〈0.001). The volumes of distribution were increased when the pretreatment was changed from ammonium chloride to sodium bicarbonate, namely from 3.51±0.41 l/kg to 5.24±0.83 l/kg (p〈0.01). The body clearance decreased from 134±21 ml/min (acidic) to 91.9±9.1 ml/min (alkaline urine) (p〈0.01). The ration Mplasma/MRBC was about 2.3 and the elimination of M from RBCs was in good agreement with the plasma kinetics of M under both experimental conditions. The salivary levels of M did not reflect the plasma kinetics and considerable variation was seen in the ratio Msaliva/Mplasma (0.26–2.98). Thus, the present experiments demonstrate that pretreatment either with ammonium chloride or bicarbonate had profound effects on both the distribution and elimination kinetics of methadone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 1-5 
    ISSN: 1432-1041
    Keywords: clonidine ; noradrenaline ; pharmacokinetics ; arterial blood pressure ; plasma concentration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of clonidine and its relation to blood pressure response and side effects were studied after single oral doses of 75 µg, 150 µg and 250 µg in normotensive subjects. Following oral administration, the drug was absorbed rapidly after an initial lag time of 19–22 min and peak levels were reached between 2.4 and 2.9 h. Sampling over 48 h was necessary for accurate estimation of pharmacokinetic parameters. Post-peak plasma concentration declined in a monoexponential manner and the half-life of the elimination phase ranged from 9.0 to 15.1 h. Maximum plasma concentration (Cmax) and area under curve (AUC) increased proportionally with increasing doses. Clonidine produced significant reductions in the pulse rate and a dose dependent decrease in blood pressure. Clonidine (150 µg) also produced significant reductions in plasma catecholamine levels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 331-333 
    ISSN: 1432-1041
    Keywords: ketoconazole ; vaginal candidosis ; oral antimycotic ; distribution ; pharmacokinetics ; vaginal tissue concentrations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Plasma samples and biopsies of vaginal tissue were obtained from 23 healthy women undergoing operative sterilization, 1 to 6 h after a single oral dose of ketoconazole 200 mg. Drug concentrations in plasma and tissue, were measured by a specific gas chromatographic method. The vaginal tissue concentration averaged 2.4 times less than the corresponding plasma levels. Equilibrium between tissue, and plasma was established within 1 h after dosing, when vaginal tissue levels exceeded 1 µg/g. Ketoconazole concentrations decayed monoexponentially over the time interval studied (1–6 h), with the similar half-lives of 1.2 and 1.4 h in plasma and tissue, respectively. Following an oral 200 mg dose, a tissue concentration not less than 0.01 µg/ml was maintained over a 12 h period. This concentration has been shown to prevent outgrowth of the invasive (pseudo) mycelial form ofCandida albicans. Hence, a b.i.d. or t.i.d. dosage schedule of ketoconazole in vaginal candidosis would give continuously effective levels at the site of infection. Ketoconazole concentrations in vaginal fluid are thought to be much higher than in the tissue because of ion-trapping. The present data may explain the efficacy of oral ketoconazole in the treatment of vaginal candidosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 293-301 
    ISSN: 1432-1041
    Keywords: metipranolol ; deacetyl metipranolol ; pharmacokinetics ; bioavailability ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetic parameters of deacetyl metipranolol were determined after i.v. infusion of increasing doses (6–25 mg) in 17 normal volunteers. In a second cross-over trial, deacetyl metipranolol 10 and 20 mg were infused in a further 10 subjects, and in a third trial another 20 volunteers received metipranolol 40 mg orally. Metipranolol is very rapidly and completely deacetylated in man, so all pharmacokinetic data refer to deacetyl metipranolol, which was assayed by gas chromatography-mass spectrometry. The pharmacokinetic analysis was performed using a recently developed model, using a volume of distribution which is variable with time. The following data were obtained after oral administration: (mean values); lag-time 7.3 min; tmax 50 min, invasion half-life 6.3 min; elimination half-life 3 h; urinary excretion of unchanged drug approximately 4% of the dose. The experiments with infusion of increasing doses, as well as the cross-over study with 10 and 20 mg i.v., showed dose-linearity of the kinetics. The respective mean half-lives of elimination were 2.6, 2.9 and 2.8 h. The mean total, renal and extra-renal clearances amounted to 1237 ml/min, 149 ml/min and 1068 ml/min, respectively. The distribution coefficient was 3.5 l/kg, and protein binding amounted to 70% within the range of therapeutic concentrations. Absolute bioavailability was found to be approximately 50% by several different evaluation procedures. Thus, the pharmacokinetic profile of metipranolol shares features of both the lipophilic and the hydrophilic groups of β-blocking agents.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 21 (1982), S. 315-323 
    ISSN: 1432-1041
    Keywords: bendroflumethiazide ; propranolol ; hydralazine ; pharmacokinetics ; thin-layer chromatography ; fluorimetry ; fixed combination product
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Bendroflumethiazide (Bft) was administered to 6 healthy subjects at 3 different dose levels (2.5, 5 and 10 mg) in a cross-over design, either as capsules (2.5 mg) or as tablets (5 mg). Its pharmacokinetics were evaluated then and following administration of a fixed combination of Bft with propranolol and hydralazine to a further 7 volunteers. Plasma and urinary concentrations of Bft were determined by a new fluorimetric — thin-layer chromotography procedure. Peak plasma levels occurred after 2–3 h and averaged 15, 27 and 45 µg/l in the three dose groups. Areas under the plasma concentration — time curves (AUC0→12), which were 75, 147 and 250 µg l−1 h respectively, and cumulative urinary recovery (20%) were independent of the dose administered and the type of formulation. Thus Bft kinetics proved to be linear within the dose range evaluated. The plasma clearance was calculated to be 505 ml/min, renal clearance 108 ml/min and nonrenal clearance 396 ml/min. Bioavailability of Bft was not altered following administration of the fixed combination. The amount of propranolol found in the circulation did not change, whereas that of hydralazine (determined as apparent hydralazine) increased by 59% when the fixed combination was administered.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 1432-1041
    Keywords: clomipramine ; desmethylclomipramine ; depressive syndrome ; plasma level ; pharmacokinetics ; clinical response ; benzodiazepines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Thirty one in-patients suffering from depression were treated orally with clomipramine (Cl) at various dosage, for 28 days, after a “wash-out” period of three days. In 17 patients receiving 75 mg per day of Cl, steady state plasma levels of Cl were reached at Day 14, and steady state plasma levels of its active metabolite, desmethylclomipramine (DMCl), were reached at Day 21. In contrast, in 7 other patients receiving a dosage increasing to 150 mg per day at Day 7, mean plasma levels of Cl and DMCl continued to rise during the entire treatment period. At the steady state, a correlation was found between Cl dosage expressed as mg kg body weight and the plasma concentration of Cl and DMCl. Factors such as tobacco and alcohol consumption seem to modify the Cl/DMCl ratio. A comparison of clinical response with plasma levels of Cl, DMCl and Cl + DMCl showed a significant negative linear correlation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 273-279 
    ISSN: 1432-1041
    Keywords: amoxycillin ; i.v. administration ; pharmacokinetics ; two- and three-compartment models
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetic characteristics of amoxycillin were studied in healthy volunteers after intravenous injection of 250 mg, 500 mg and 1,000 mg, and infusion of 2 g and 5 g. Serum concentrations were fitted using either bi- and tri- exponentional equations. Comparison of the regression curves obtained revealed that the three-compartment model gave a better fit to the serum concentration versus time curve. It was evident that there was a third, slow, dose dependent phase of disposition. This result has been confirmed by the fact that the terminal half life of amoxycillin on cessation of a continuous infusion is significantly greater than after acute administration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    ISSN: 1432-1041
    Keywords: indapamide ; bioavailability ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Two formulations of indapamide tablets (2.5 mg) were given as a 5.0 mg dose and the subsequent blood levels were compared to those obtained after administration of a 5.0 mg solution. The study was conducted as a randomized three-way crossover design using healthy male volunteers. The drug was well tolerated by all the subjects involved. The area under the blood concentration versus time curve, extrapolated to infinity was essentially the same for all three formulations (4.2, 4.7, and 4.4 µg-h/ml). Statistical comparison of the blood levels from the two tablets showed that one tablet had a significantly greater maximum blood concentration (263 vs 231 ng/ml) and a significantly shorter time of maximum blood concentration (2.3 vs 3.5 h). Cmax (333 ng/ml) and tmax (0.7 h) values for the solution were significantly higher than either tablet. The average half-life (β-phase) for all three formulations was 15 h, while the average systemic clearance was 20 ml/min. Indapamide has a low clearance rate and there was no evidence that the drug undergoes a first-pass effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 257-264 
    ISSN: 1432-1041
    Keywords: TRIS buffer ; metabolic acidosis ; pharmacokinetics ; cellular uptake ; renal excretion ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary To investigate the pharmacokinetics of TRIS, an infusion of the buffer was given to 6 healthy volunteers (121 mg/kg=1 mmol/kg; pH 7.4) and to 20 patients suffering from metabolic acidosis (109–376 mg/kg; pH 10.9). The drug exhibited two-compartment characteristics in volunteers (t0.5,β=5.6 h) and patients with intact renal function (t0.5,β=16.3–45.6 h). The final volume of distribution (Vβ) indicated uptake into tissues, but equilibration between body compartments was slow. Mainly unchanged TRIS was eliminated by the kidney; 82% of the administered dose was recovered from 24 h-urine of healthy subjects. In the patients a linear correlation between creatinine-clearance and TRIS-clearance was observed, the latter always being somewhat greater than the former. Only insignificant amounts of the drug were found in bile and gastric juice. In anuric patients the plasma concentration of TRIS declined monoexponentially, with a half-life between 10 and 58 h. Haemodialysis or haemofiltration did not influence this process. From the data it seems questionable whether cellular uptake of TRIS is an important factor in the therapy of intracellular acidosis, but the possibility of drug accumulation must be borne in mind if repeated doses are given to the same patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 343-349 
    ISSN: 1432-1041
    Keywords: methadone ; opiate addicts ; pharmacokinetics ; single and multiple doses ; stable isotope technology ; methadone maintenance therapy ; deuterium technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Deuterated methadone (M-d30) and GC-MS were used to study the pharmacokinetics of methadone (M) during the induction stage of methadone maintenance treatment (MMT). A pulse dose of M-d3 was given on Days 1 and 25 of two dosage regimens, one with a continuous 30 mg dose (n=6), and the other with 30 mg for 10 days, followed by 60 mg as the maintenance dose (n=6). Plasma and urinary levels of M and M-d3 were measured throughout and plasma half-lives, oral bioavailabilities and volumes of distribution were calculated from the data of Days 1–2 and 24–26. The oral bioavailability of a methadone solution was found to be between 81 and 95%; elimination half-life in the β-phase varied between 19 and 58 h; the volume of distribution was 4.1±0.65 l/kg; and total body clearance of M was 54–195 ml/min and its renal clearance 3.4–34 ml/min. A consistent finding was a lower urinary pH and increased renal clearance during the first days of MMT as compared with after one month. In 4/12 of the patients dispositional tolerance was developed to methadone during the first month of treatment. The shorter elimination half-lives in those patients probably caused unacceptably high fluctuation in the body content of M during the 24 h dosage interval, and may have interfered therefore, with its therapeutic effectiveness
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 359-365 
    ISSN: 1432-1041
    Keywords: chlorpheniramine ; pharmacokinetics ; oral absorption ; half-life ; bioavailability ; volume of distribution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Plasma and urinary levels of chlorpheniramine (CPM) and its 2 demethylated metabolites were measured by HPLC after i.v. and oral dosing. In 5 mg (maleate) i.v. bolus studies in 2 subjects, plasma CPM levels were fitted to triexponential equations with terminal half-lives (t 1/2) of 23 and 22 h and area of 3.6 and 3.21/kg, respectively. Intravenous data predicted hepatic blood extraction ratios for the 2 subjects to be 0.06 and 0.07, respectively. Absolute bioavailability from oral solution (10 mg) was 59 and 34%, and from tablets (8 mg) 44 and 25%, respectively, indicating extensive gut first-pass metabolism. Mean t 1/2 from 7 oral fasting studies in 5 subjects was 28 h (19–43 h). Mean absorption lag time was 0.7 h (0.4–1.3 h), and mean peak time was 2.8 h (2–4 h). In 2 subjects, 6 mg solutions were given every 12 h for 9 doses; good correlation between single and multiple dose kinetics was found. Significant accumulation was demonstrated in simulation studies with frequent daily dosing. Estimated accumulation ratios vary from 4.1 to 9.4 (mean 6.5). The t 1/2 from urinary data (collected for 12 days) was consistent with plasma data. The above results suggest the need to reexamine the current practice of frequent daily dosing and the use of sustained or controlled release dosage forms of this drug. The possible cause of reduced plasma clearance of CPM in renal patients is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 75-80 
    ISSN: 1432-1041
    Keywords: psoriasis ; 8-methoxypsoralen ; food influence ; suction blister fluid ; serum ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The influence of food on the kinetics of 8-methoxypsoralen (8-MOP) in serum and suction blister fluid was evaluated in a cross-over study in 19 psoriatic patients under PUVA treatment. The peak serum concentration of 8-MOP was reached 1.5 h after ingestion on an empty stomach, and in suction blister fluid the maximum concentration was already present in the first sample taken after 2 h, the time when UVA radiation was given. The postprandial kinetics of 8-MOP in serum and suction blister fluid differed, the highest levels being reached, respectively, at 2.4 and 3 h after intake, i.e. in both body fluids after irradiation had started. The side effects of 8-MOP, such as nausea and dizziness, in the two groups were similar. The present results indicate that to optimize the therapeutic effect of PUVA in individual patients, 8-MOP should be given on an empty stomach.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 93-97 
    ISSN: 1432-1041
    Keywords: tolmesoxide ; vasodilator ; hypertension ; pharmacokinetics ; haemodynamics ; plasma renin activity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The haemodynamic response and pharmacokinetics of single dose oral tolmesoxide were studied at various dose levels in 4 patients with severe hypertension. There was a reproducible fall in mean arterial pressure from baseline of 24.2% and a rise in heart rate of 37.6% following administration of tolmesoxide. The onset of antihypertensive action occurred within 1 h, with a peak effect at 3 h after dosing. The mean duration of action was up to 12.0 h. Tolmesoxide had a mean half-life of 3.0 h. It was rapidly absorbed with a mean peak plasma level occurring at 1.0 h. Plasma levels correlated well with the doses administered. Side-effects included mild nausea, facial flushing and postural symptoms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 189-195 
    ISSN: 1432-1041
    Keywords: befunolol ; propranolol ; pharmacokinetics ; pharmacodynamic effects ; beta-adrenoceptor blocking agent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Repeated doses of a new β-adrenoceptor blocking agent, befunolol, were administered orally to adult male volunteers for a cross-over comparison with propranolol. The β-adrenoceptor blocking activity of befunolol was greater than that of propranolol when assessed by the percentage reduction in exercise-induced tachycardia. The elimination half-life of drug was significantly prolonged on repeated administration of propranolol, but not of befunolol. The percentage reduction in exercise-induced tachycardia was highly correlated with the log plasma level of each drug. Both drugs produced a significant reduction in pre-exercise systolic and diastolic blood pressure, and significant attenuation of exercise-induced rise in systolic blood pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 37-42 
    ISSN: 1432-1041
    Keywords: metoprolol ; propranolol ; oxprenolol ; pharmacokinetics ; acetubolol ; diacetolol ; oral contraceptive
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Plasma concentrations of metoprolol, propranolol oxprenolol, acebutolol and its metabolite diacetolol were measured after single oral doses in young healthy volunteers. In order to assess the inter-and intra-subject variability the following pharmacokinetic parameters were compared: AUC o 24 , Cmax, tmax and t1/2. The smallest variation in inter-subject variability was seen with oxprenolol and acebutolol: intrasubject variability was more uniform. Female volunteers taking an oral contraceptive generally had higher AUC o 24 and Cmax values than those not. This finding reached statistical significance only for metoprolol AUC o 24 .
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 49-57 
    ISSN: 1432-1041
    Keywords: verapamil ; norverpamil ; pharmacokinetics ; atrial fibrillation ; oral administration ; i.v. administration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetic parameters and oral bioavailability of the antiarrhythmic drug verapamil were determined in six patients with atrial fibrillation. Plasma samples were taken following i.v. injection of verapamil 10 mg (Isoptin® 2 ml), and oral verapamil 80 mg (Isoptin® 2 tablets of 40 mg). Verapamil and its N-demethylated metabolite, norverapamil, were analyzed to 1 ng/ml plasma by gas chromatography-mass spectrometry using deuterated standards. Following intravenous injection, the disposition of verapamil followed a biexponential pattern with a fast distribution phase and a slower elimination phase (t1/2β=5.79 h), corresponding to a plasma clearance of 0.26 1/kg/h. After oral administration, only an elimination phase was evident, with the same elimination rate (t1/2β=5.53 h). The oral bioavailability was 10.5%±7.5%. The norverapamil formed after i.v. and oral administration of verapamil had plasma half-lives of 5.86 h and 6.77 h, respectively. The elimination of verapamil in patients with atrial fibrillation was decreased compared to that in healthy young volunteers and the oral bioavailability was lower. Very good correlation between the percentage reduction in heart rate and the log plasma concentration of verapamil was found in every patient during the elimination phase, irrespective of the route of administration. There was also a high correlation when the plasma concentration — effect data from all the patients were pooled (r=0.59,n=71;p〈0.0005).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 123-127 
    ISSN: 1432-1041
    Keywords: theophylline ; bronchiolitis ; infants ; pharmacokinetics ; single dose ; multiple doses ; HPLC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Theophylline pharmacokinetics were studied in 12 infants (age 3 weeks–6.5 months) with bronchiolitis. 9 of the 12 patients received a single dose of aminophylline (5.0–8.5 mg/kg) whereas the remainder were at steady-state receiving multiple doses (2.5–5.0 mg/kg) of aminophylline. The dose was administered IV over 0.5–1.0 h. An HPLC method was used to measure theophylline concentrations in serum and urine. Peak serum concentrations of theophylline measured by HPLC ranged from 8.48–21.6 µg/ml. Total, renal and nonrenal clearance of theophylline ranged from 4.66 to 19.25, 1.07 to 5.76 and 3.59 to 16.83 ml/min/m2, respectively. Mean apparent volume of distribution and elimination half-life were 8.75 l/m2 and 11.38 h, respectively. Although no significant correlation was observed between age and theophylline kinetic parameters, clearance appeared to increase and half-life decrease with age. Our patients had a substantially lower clearance and longer half-life as compared to published data in children 〉1 year of age. A five-fold variation in theophylline clearance demonstrates the need for monitoring theophylline serum concentration to minimize the risk of potential toxicity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 129-134 
    ISSN: 1432-1041
    Keywords: theophylline ; ethinylestradiol ; oral contraceptives ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effect of chronic oral contraceptive (OC) usage on the disposition of theophylline was examined. Aminophylline solution (4 mg/kg) was given orally to 8 healthy female non-OC users and to 8 healthy women who were chronic (〉6 months) OC users. The OC user group had a significantly lower total plasma clearance of theophylline than women not using OC (35.1±5.6 vs. 53.1±14.5 ml/h/kg). The t1/2 was also significantly prolonged in the OC group (9.79±1.43 vs. 7.34±1.75 h) while the volume of distribution was similar between the 2 groups. The serum ethinylestradiol (EE) concentrations after oral OC administration were measured simultaneously. The apparent clearance of EE was about 30% lower in the OC users. A significant positive correlation was found between the apparent clearance of EE and the plasma clearance of theophylline. The effects of OC are predominantly due to chronic use with decreased elimination of both theophylline and EE.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 167-172 
    ISSN: 1432-1041
    Keywords: ticarcillin ; probenecid ; excretion ; pharmacokinetics ; automated chemical assay method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The excretion of radioactivity has been investigated in 3 healthy volunteers following rapid intravenous administration of 5 g of [35S]-ticarcillin. The radioactive dose was rapidly and completely excreted, since within 4 days 98.5% was recovered, 95% in the urine and 3.5% in faeces. All the urine radioactivity was accounted for as ticarcillin and its penicilloic acid. Plasma and urine samples collected from the volunteers at frequent intervals during the first 6 h of the experiment were assayed for penicillin by an automated chemical method and also for radioactivity. The results obtained by the chemical autoanalyser method were in excellent agreement with the plasma levels of radioactivity. From the data it was possible to calculate the renal clearance of the penicillin, a mean value of 104 ml/min was observed in the 3 volunteers. A further three volunteers were dosed intravenously with a 5 g bolus of non-radiolabelled ticarcillin in a cross-over study with and without predosing with probenecid. Serum samples were analysed by the chemical method for penicillin and the data subjected to pharmacokinetic analysis using a two compartment open model. The results indicate a shift of the distribution equilibrium of ticarcillin from the serum into the peripheral compartment after predosing with probenecid. Furthermore, the mean half-life of ticarcillin in the serum of the three volunteers was significantly increased from 1.3 h to 2.1 h by predosing with probenecid.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 1432-1041
    Keywords: dipyridamole ; platelets ; plasma levels ; pharmacokinetics ; adenosine uptake
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Two preparations of dipyridamole have been studied by oral administration to 11 normal volunteers. The plasma levels of dipyridamole and its glucuronide were determined simultaneously by high performance liquid chromatography. The instant form (I.F., 100 mg) was administered four times daily and the slow release preparation (SRP, 200 mg) twice daily, for 3 days. Multiple blood samples were collected on Days 1–4 to provide plasma for assay, and simulteneously, platelet rich plasma was prepared for ex vivo study of the effect of dipyridamole on platelet uptake of adenosine. The pharmacokinetics of absorption and distribution of dipyridamole were described using a two compartment model with lag time and prolonged absorption. Strong inhibition of the platelet adenosine uptake was observed at therapeutic plasma levels. The inhibition of platelet adenosine uptake may be related to some of the pharmacological properties of dipyridamole.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 315-320 
    ISSN: 1432-1041
    Keywords: furosemide ; cirrhotic patients ; ascitic fluid ; diuretic effect ; pharmacokinetics ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of furosemide was studied in 7 patients with diagnosed liver cirrhosis and in 7 healthy subjects. Furosemide in plasma and ascitic fluid was analyzed spectrofluorometrically. After a single intravenous dose, the cirrhotic patients showed lower initial plasma concentrations of furosemide because of the larger volume of distribution. The mean half-life in cirrhotic patients was significantly greater than in healthy volunteers. The longer half-life was associated with a reduction in the serum clearance of furosemide. Ascitic fluid volume in the patients ranged from 4.6 to 7.71. There was no significant amount of furosemide in the fluid. The diuretic interchange between this fluid and plasma was slow, as peak concentrations ranged from 0.3 to 0.5 µg/ml within 3 to 5 h after bolus administration of furosemide. Diuresis and urinary sodium excretion, 5 h after furosemide injection, were similar in both groups; larger potassium excretion was found in the cirrhotic patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 43-47 
    ISSN: 1432-1041
    Keywords: timolol ; pharmacokinetics ; pharmacodynamics ; healthy subjects ; cardiac infarction patients ; i.v. therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Disappearance pharmacokinetics, pharmacodynamics and general tolerance of i.v. timolol were compared in 12 healthy volunteers and 10 patients with a definite or proven acute myocardial infarction. The drug was administered to the patients immediately on arrival at the hospital after a median delay time of 4 h. Tolerance to the injections was good in both volunteers and patients. The study revealed disappearance pharmacokinetics that were similar in volunteers and patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 23 (1982), S. 173-176 
    ISSN: 1432-1041
    Keywords: melperone ; neuroleptic drug ; dose dependent kinetics ; i.m. injection ; i.v. injection ; pharmacokinetics ; oral application
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of melperone (Buronil®, Ferrosan, Sweden) was studied after administration of various parenteral and oral doses to man. After parenteral administration, the data could be fitted to a two-compartment model, but after oral dosing the distribution phase could not be separated from the elimination phase, and so an one-compartment model gave the best fit. The half-lives were about 3–4 h, except after intramuscular injection, when the half-life was about 6 h. The bioavailability of oral doses was about 60% of the intravenous injection. After the highest oral dose of 100 mg, the pharmacokinetics, expressed as AUC or Cmax, showed non-linearity, possibly due to saturation of the hepatic elimination system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1573-8744
    Keywords: antiarrhythmic compound ; experimental arrhythmia ; pharmacokinetics ; three compartment model ; pharmacological response ; combined pharmacokinetic pharmacodynamic model
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Pharmacokinetics and pharmacodynamics were studied in three dogs with interventricular coronary artery ligatures (ligature of Harris) and in three control animals. Weighted nonlinear analysis was used to fit equations describing two and three compartment open models to the experimental data, obtained after intravenous injection (5 mg/kg) of the drug. The three compartment model gave a reduction in the weighted sum of squared residuals and an improvement in the randomness of scatter of the experimental points about the theoretical curve. The postdistribution elimination half-life was longer, the area under the plasma elimination curve larger, and the total body plasma clearance and apparent volume of distribution was reduced in the animals with arrhythmias. The pharmacological response was assessed by recording the ECG and calculating the percentage of normal sinus rhythm/min. A combined pharmacokinetic-pharmacodynamic model was used to analyze data from individual animals. ke0, a measure of the lag time of pharmacological response behind changes in plasma concentration, and Ce (50), a measure of the sensitivity of the cardiac site of action of the drug, were determined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    ISSN: 1573-8744
    Keywords: disopyramide ; pharmacokinetics ; antiarrhythmic, healthy subjects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Disopyramide exhibits saturable binding to plasma proteins in the therapeutic plasma concentration range. Because of this property, controversy exists in the literature regarding the pharmacokinetic properties of the drug. The purposes of this study were to reassess the pharmacokinetic properties of disopyramide in humans, taking into consideration both total and unbound concentrations and to use disopyramide as a model compound to study the effect of drug binding on the renal clearance of both total and unbound drug. A single intravenous dose of disopyramide (1.5 mg/kg) was administered to eight normal volunteers. Blood and urine samples were collected for 36h. Total concentrations of disopyramide in plasma and urine were determined by high pressure liquid chromatography. Binding of disopyramide to plasma proteins was determined by equilibrium dialysis. In all subjects, the binding of disopyramide to plasma proteins was saturable, but there were considerable differences in binding between subjects. The volume of distribution, total body clearance, and renal clearances of both total and unbound drug were calculated. Because only the total body clearance and renal clearance of unbound compound are not dependent upon unbound fraction (α), these are the only parameters which can be reported without qualification as to the concentration. The mean ± SD total body clearance of unbound drug in the eight subjects was 5.40± 2.80 ml/min/kg. About 50% of this was due to renal elimination. A statistically significant negative correlation of the renal clearance of total disopyramide with time was observed in seven of eight subjects, whereas a significant correlation between the renal clearance of unbound disopyramide and time was observed in only one subject. This suggests that the renal clearance of unbound disopyramide is independent of α, while the renal clearance of total disopyramide is dependent upon α.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Journal of pharmacokinetics and pharmacodynamics 10 (1982), S. 27-51 
    ISSN: 1573-8744
    Keywords: pharmacokinetics ; models ; plasma protein binding ; nonlinear processes ; Sulfaethidole
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Sulfaethidole distribution and elimination in the rat was studied over a 90-fold dose range. This experimental design produced marked nonlinearity in the binding of Sulfaethidole to proteins in both interstitial fluid and plasma. Using a multicompartmental model consisting of binding of Sulfaethidole to plasma and interstitial fluid proteins, Sulfaethidole distribution in the body could be simulated. Urinary and biliary elimination of Sulfaethidole depended on the unbound drug mass in the plasma and urine flow. The results confirm the central role of the unbound species in the distribution and elimination of drugs with marked binding to plasma proteins.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Journal of pharmacokinetics and pharmacodynamics 10 (1982), S. 201-227 
    ISSN: 1573-8744
    Keywords: interspecies variations ; scaling ; heterogony ; allometry ; pharmacokinetics ; physiological time ; pharmacokinetic time ; maximum lifespan potential
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Interspecies variation in pharmacokinetics is considered and treated as a property and consequence of body size (allometry). Consequently, it is possible to reference (scale) pharmacokinetic parameters to the organism's individual anatomy, biochemistry, and/or physiology in such a manner that differences between species are nullified. Thus, in the mouse, rat, dog, monkey, and human, methotrexate plasma clearance always equals 133% of creatinine clearance and as such becomes invariant. Pharmacokinetic time (a variable in terms of chronological time) is shown to be a form of physiological time in which a pharmacokinetic event becomes the independent variable, e.g., disposition halflife. A relationship between pharmacokinetic time and body size is demonstrated. It is suggested that man's lesser quantitative ability to metabolize many drugs may be correlated with his enhanced longevity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 1573-8744
    Keywords: diuretic ; bumetanide ; pharmacokinetics ; pharmacodynamics ; normals
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The pharmacokinetics and pharmacodynamics of bumetanide (1 mg) administered either orally or intravenously were studied in a group of normal subjects using high-pressure liquid chromatography. A two-compartment model adequately fitted the intravenous data. Renal clearance (85 ml min−1 contributed 65% to the total elimination of bumetanide irrespective of whether a model-dependent or model-independent method was used. Oral administration of bumetanide elicited a greater and a more prolonged pharmacological response than did intravenous bumetanide. An attempt is made to relate the pharmacokinetics of the drug to its pharmacodynamics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of experimental biology and medicine 94 (1982), S. 1069-1071 
    ISSN: 1573-8221
    Keywords: pharmacokinetics ; alcohol ; alcohol abstinence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of experimental biology and medicine 94 (1982), S. 1373-1375 
    ISSN: 1573-8221
    Keywords: pharmacokinetics ; phenazepam ; 3-hydroxyphenazepam ; cats ; blood ; metabolic model
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of experimental biology and medicine 94 (1982), S. 1689-1692 
    ISSN: 1573-8221
    Keywords: ethanol preference ; endogenous ethanol ; pharmacokinetics ; estrous cysle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 80-84 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Wiederkehrende Prüfungen am Reaktorkühlsystem bei LeichtwasserreaktorenUm eine dauerhafte Sicherheit der Komponenten des Reaktorkühlsystems zu gewährleisten, werden nach Inbetriebnahme eines Kernkraftwerks wiederkehrende Prüfungen durchgeführt.Dieser Beitrag behandelt die Komponenten des Reaktorkühlsystems in Bezug auf die gesetzlich vorgeschriebenen Auflagen, sicherheitstechnischen Aspekte und den Umfang der wiederkehrenden Prüfungen während des laufenden Reaktorbetriebs.Im einzelnen werden die Art und zeitliche Folge der Prüfungen, die Durchführungstechnik, ihre Ergebnisse und künftige Entwicklungstendenzen beschrieben.Funktionsprüfungen, die im Rahmen der wiederkehrenden Prüfungen anfallen, sind nicht Gegenstand dieses Beitrags.
    Notes: In order to guarantee constant safety of the components of the reactor cooling system, regular in-service inspections are carried out after commissioning of the nuclear power plant.This contribution is concerned with the components of the reactor cooling system, referring to the legal requirements, safety-related purposes and scope of the in-service inspections during the entire period of operation of a nuclear power plant.Reports are made with respect to type, examination intervals, examination technique, results and future development.The functional tests which are carried out within the scope of the inservice inspections are not part of this contribution.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982) 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A33 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A39 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 103-109 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Deep Rolling and Fatigue StrengthThe fatigue properties of specimens and components are largely increased by deep rolling. Depending on geometrical shape of components and material strength the compressive residual stresses and the increased surface hardness made by deep rolling have a different effect on the improvement of fatigue strength.The fatigue properties of smooth specimens and components with a sufficient toughness can be raised by increase of surface hardness, whereas in case of notched parts the influence of permanent compressive residual stresses is dominant.The application of deep rolling in case of crankshafts shows a clear superiority of mechanical strengthening procedure to thermal surface strengthening. If there are some reasons to improve the wear behaviour beside the fatigue strength it is commendable to combine thermal and mechanical surface strengthening.
    Notes: Die Schwingfestigkeitseigenschaften von Proben und Bauteilen können durch Festwalzen beträchtlich angehoben werden. Je nach Bauteilgeometrie und Werkstoffestigkeit wirken sich die durch den Festwalzprozeß eingebrachten Druckeigenspannungen 1. Art und die Randhärtesteigerung unterschiedlich auf die Erhöhung der Dauerfestigkeit aus. Während bei glatten Proben oder Bauteilen ausreichender Duktilität der Zuwachs an Schwingfestigkeit im wesentlichen auf die Zunahme der Randhärte zurückzuführen ist, beruht die Dauerfestigkeitserhöhung von Bauteilen mit Kerben auf das Vorhandensein stabiler Druckeigenspannungen.Die Anwendung des Festwalzprozesses bei Kurbelwellen zeigt die deutliche Überlegenheit des mechanischen Verfestigungsverfahrens gegenüber einem rein thermischen Randschichthärteverfahren. Sollte neben der Schwingfestigkeit auch das Verschleißverhalten verbessert werden, empfiehlt sich eine Kombination von thermischem und mechanischem Oberflächenverfestigungsverfahren.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A40 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 120-128 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The Prediction of the Fatigue Strength with Regard to the Statistical Size Effect310 fatigue tests in the range for alternating stresses were performed with smooth and notched round bar specimens (Fig. 5 and Table 3) of different size. The 30 (20) tests of each series were fatigued at two stress levels with constant maximum root stress σ1 max and σ2 max. At each stress level, the probability of fracture (Eq. 11) had been determined. The test results are shown in Table 2. The evaluation of the test results was made on the basis of a two-parametric-Weibull-equation (Eq. 2) which can be derived by the theory of extreme value statistics. In the case of a non-uniform-stress-field (notched specimens), Eq. 2 is replaced by Eq. 6. The stress-integral (Eq. 6b) was numerically calculated for the different shapes of the specimens used. The value of the stress-integral A can also be obtained by Eq. 10 with an accuracy better than 11%. The Eqs. 7, 8 and 9 were used to calculate and predict test results. To show the error which arises by the application of the Eqs. 7, 8 and 9, the fatigue stress at 50% probability of fracture was calculated and compared with the experimental results. If the results of only one test series are used to calculate the fatigue strength of all the other series, the mean deviation is 5%, the maximum observed deviation is 14,1% (Table 5). If all the results are used to determine the constants of the two-parametric-Weibull-equation (Eq. 16), all the test results can be predicted with an accuracy better than 5,7%.In cases of homogeneous materials and mainly linear elastic stress-strain relationship, the two-parametric-Weibull-equation therefore is very well suited to describe the size effect in fatigue (Fig. 6).
    Notes: Es wurden 310 Zug-Druck-Dauerschwingversuche im reinen Wechsellastbereich an glatten und gekerbten Rundproben unterschiedlicher Größe (11 Probeserien) im Übergangsgebiet des Wöhlerfeldes durchgeführt. Die Auswertung der Versuche erfolgte unter Zugrundelegung der statistischen Fehlstellentheorie. Die beiden Konstanten des zweiparametrigen Weibullansatzes wurden für jede Probenserie bestimmt. Der Vergleich zwischen experimentellem und berechnetem Wert wurde jeweils für die Dauerfestigkeit mit einer Bruchwahrscheinlichkeit von 50% vorgenommen. Verwendet man zur Vorhersage die Ergebnisse nur einer Probeserie, so können die. Ergebnisse der anderen Probeserien mit einem mittleren Fehler von 5% (max. 14,1%) berechnet werden. Legt man alle experimentellen Ergebnisse der Vorhersage zugrunde, so verringert sich der mittlere Fehler auf 3,2% (max. 5,7%). Die statistische Fehlstellentheorie kann daher für querschnittshomogene Werkstoffe im Übergangsgebiet des Wöhlerfeldes mit sehr gutem Ergebnis zur Beschreibung des Größeneinflusses herangezogen werden.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 138-147 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Transformation-Toughened CeramicsA summary is given on the toughening of ceramics by utilizing the tetragonal-to-monoclinic phase transformation of ZrO2 particles dispersed in the ceramic matrix. Various parameters controlling this martensitic transformation (especially Ms) are discussed together with in situ-TEM observations. The possible toughening mechanisms that allow for additional energy dissipation at crack tips are stress-induced transformation and nucleation of microcracks. Further strengthening is achieved by introducing steady-state surface compressive stresses. The type and magnitude of toughening is controlled by the microstructural design parameters such as volume fraction, chemical composition, size and size distribution of ZrO2 particles which again determine the Ms temperature. The homogeneous dispersion of ZrO2 is the most important step in the technology of transformation-toughened ceramics. Experimental examples for the toughening effect are given for the ceramic matrices Al2O3, ZnO, spinel, mullite and Si3N4.
    Notes: Die Arbeit gibt einen Überblick über Forschungsergebnisse des Max-Planck-Instituts für Metallforschung auf dem Gebiet der Umwandlungsverstärkung keramischer Werkstoffe. Die kontrollierte Ausnutzung der tetragonal → monoklinen Phasenumwandlung dispergierter ZrO2-Teilchen ermöglicht eine Reihe unterschiedlicher Verstärkungsarten, die im wesentlichen von der Umwandlungstemperatur (Ms) bestimmt werden. Die Einflußparameter von Ms, z. B. Volumenanteil, chemische Zusammensetzung, Größe und Größenverteilung der ZrO2-Teilchen und die daraus abzuleitenden Maßnahmen für eine Gefügeentwicklung, werden besprochen. Die möglichen Mechanismen für eine zusätzliche Absorption von Bruchenergie, und damit für eine Erhöhung des Bruchwiderstands sind spannungsinduzierte Umwandlung und Bildung von Mikrorissen. Eine weitere Verstärkung kann durch Einbringen von Oberflächendruckspannungen erzielt werden. Der wichtigste technologische Schritt in der Herstellung umwandlungsverstärkter Keramiken ist eine homogene Dispersion der ZrO2-Teilchen. Eine Reihe experimenteller Beispiele für die Verstärkung von Al2O3, ZnO, Mullit, Spinell und Si3N4 mit Hilfe von ZrO2 wird diskutiert.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982) 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 176-181 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Preparation and Properties of Layered Composites of GFK-SteelThe development of insulating joints of GFK and steel is described. The strength of the GFK and steel is described. The strength of the GFK and the adhesion between the GFK and steel is in this context of special interest. Results for the Young's Modulus, the ultimate and adhesion strength measured in bursting and bending tests are compared to those measured in tensile- and adhesion tests; the data agree well with each other. The correspondence between literature data of mechanical properties of the GFK and the measured values is satisfying.
    Notes: Es wird die Weiterentwicklung von Isolierstücken für erdverlegte Leitungen bis zur Abnahmereife durch den Technischen Überwachungsverein mit besonderer Berücksichtigung der Festigkeit des glasfaserverstärkten Kunststoffes und der Haftung des glasfaserverstärkten Kunststoffes am Trägermaterial angegeben. Ergebnisse für den E-Modul, die Zug- und Haftfestigkeit ermittelt aus Berst- und Biegeversuchen an den Isolierstücken werden verglichen mit Daten, die sich aus Zerreiß- und Haftfestigkeitsuntersuchungen ergeben. Die Übereinstimmung ist befriedigend; die Daten sind im Einklang mit Literaturergebnissen an vergleichbaren glasfaserverstärkten Kunststoffen.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 204-207 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Ermüdungsverhalten der Legierung Ti-6AI-4VEs wurden Wechselverformungsversuche (LCF) in Vakuum und Luft durchgeführt. Unter zyklischer Beanspruchung trat in der Ti-6Al-4V in Abhängigkeit von der Aushärtung, der Spannungsamplitude und der Mikrostruktur sowohl Verfestigung als auch Entfestigung auf. Die plastische Verformung der β-Phase verursachte im ungehärteten Zustand infolge der spannungsinduzierten martensitischen Umwandlung eine zyklische Verfestigung. Zyklische Entfestigung wurde gemessen, wenn die durch kohärente Ti3Al-Teilchen ausgehärtete α-Phase plastisch verformt wurde.Die globularen Gefüge zeigten eine stärkere zyklische Entfestigung als die lamellaren Gefüge. Dieses Verhalten konnte dadurch erklärt werden, daß die globularen Gefüge eine ausgeprägte Textur besaßen, während die lamellaren Gefüge texturlos waren.Im Bereich der Kurzzeitermüdung (LCF) wurde die Lebensdauer entscheidend vom Entfestigungsverhalten bestimmt. Die Gefüge mit starker zyklischer Entfestigung zeigten bei Berücksichtigung der unterschiedlichen Elastizitätsgrenzen (Normierung σa/σy) geringere Bruchlastspielzahlen als die Gefüge mit schwächerer zyklischer Entfestigung.
    Notes: Low-cycle-fatigue texts in vacuum and air were performed. Under cyclic loading the Ti-6Al-4V showed both cyclic hardening and cyclic softening depending on heat treatment, stress amplitude, and microstructure. Plastic deformation of the β-phase in the unaged condition due to stress induced martensitic transformation caused cyclic hardening. Cyclic softening was observed if the α-phase hardened by coherent Ti3Al particles was plastically deformed.Equiaxed microstructures exhibited a stronger cyclic softening than lamellar structures. This behavior could be explained by the pronounced texture of the equiaxed microstructures, whereas the lamellar structures were texture-free.The fatigue life was influenced by the cyclic softening process mainly in the low-cycle-fatigue regime. The fatigue life at normalized stress amplitude (σa/σy) was shorter for microstructures with strong cyclic softening as compared to microstructures with lower cyclic softening.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 274-285 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The Formation of Surface Films and the Corrosion Resistance of the Silicon Containing Austenitic Steel X 2 CrNiSi 18 15 in Nitric AcidsThe oxide layers consist of two parts: the lower one is mainly Croxide, the upper one is SiO2. ESCA and AAS measurements were made in order to study the formation of the surface layer on the austenitic steel X2 CrNiSi 18 15 in nitric acids. A film, which is chromium oxide, is formed first. On top of this film a second film consisting of SiO2 grows. The elements nickel and manganese are not found in the formation of the oxide films. Immediately below the oxide layer the steel is enrichened with chromium and depleted of iron.In order to find the in some cases very small corrosion rates (5 · 10-5 mm · a-1) in a reproducible manner, the amounts of iron, chromium and nickel which had been dissolved were measured by means of the AAS method as a function of time.For stationary samples apparent activation energies of 65.2 kJ/Mol (azeotropic nitric acid) and 37.5 kJ/Mol (highly concentrated nitric acid), respectively, were found. These data confirm the assumption that the corrosion rate is determined by reactions at the phase boundaries.No appreciable influence of the flow velocity on the corrosion rate was detected.
    Notes: Mit Hilfe von ESCA- und AAS-Messungen wurde die Ausbildung der Deckschicht auf dem austenitischen Stahl X 2 CrNiSi 18 15 in Salpetersäuren untersucht. Es entsteht eine chromoxidreiche Deckschicht, über der sich eine SiO2-Schicht befindet. Nickel und Mangan sind am Aufbau der Oxidschichten nicht beteiligt. Unter der Oxidschicht wurde eine Chromanreicherung bzw. Eisenverarmung im Stahl nachgewiesen.Um die teilweise sehr geringen (bis 5 · 10-5 mm · a-1) Abtragungsraten reproduzierbar erfassen zu können, wurde in Lösung gegangenes Eisen, Chrom und Nickel in Abhängigkeit von der Beanspruchungsdauer mittels AAS bestimmt.Für ruhende Werkstoffproben ergaben sich scheinbare Aktivierungsenergien von 65,2 kJ/Mol (azeotrope Salpetersäure) bzw. 37,5 kJ/Mol (hochkonzentrierte Salpetersäure); diese Werte bestätigen die Annahme einer geschwindigkeitsbestimmenden Phasengrenzreaktion. Ein nennenswerter Einfluß der Fließgeschwindigkeit auf die Korrosion war nicht nachweisbar.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A84 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 355-360 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The Fatigue Behavior of SiSiCFor design purposes the engineering property datas especially the fatigue behavior of silicon carbide (SiSiC) were determined. Using linear elastic fracture mechanics the datas for slip casted and extruded SiSiC-samples were measured at room temperature. The correlation between stress, probability of failure, and time is shown in SPT-diagrams.
    Notes: Auf der Basis der Theorie der linear-elastischen Bruchmechanik wird die für die Konstruktion benötigte, zeitabhängige mechanische Festigkeit (Ermüdung) von stranggepreßtem und schlickergegossenem Siliziumcarbid (SiSiC) bei Raumtemperatur bestimmt.Der Zusammenhang zwischen Belastungshöhe, Ausfallswahrscheinlichkeit und Zeit wird in Form von SPT-Diagrammen dargestellt.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 385-388 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Fatigue crack growthIn the following paragraphs the fracture mechanics approach to fatigue crack growth will be described. A relationship between the „Wöhler-type“ concept and the fracture mechanics concept will be established and some aspects of interest for practical applications will be presented.
    Notes: Im folgenden soll das Ermüdungsrißwachstum in der bruchmechanischen Darstellungsweise erläutert werden, wobei eine Beziehung zwischen der Wöhler-Kurve (klassischer Ermüdungsversuch) und dem bruchmechanischen Ermüdungsversuch hergestellt wird, sowie einige für die Ingenieurpraxis interessante Aspekte erläutert werden.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A102 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 423-429 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Stress Fields in Concentrated Contacts - Influence of Normal Load, Tangential Load and Internal StressesThe stresses in the half space of a Hertzian Contact (coordinate stresses and equivalent stresses) are shown in dependence of geometry and Hertzian contact stress. The equivalent stresses were calculated with the Huber, von Mises, Henky criterion.The superposition of combined normal and tangential load with residual stresses in the material was calculated for point and line contact. The course of the maximum of the equivalent stress in dependence of the residual stresses with the parameter friction coefficient is shown.
    Notes: Der Spannungszustand (Koordinatenspannungen, Vergleichspannung) im Halbraum des Hertzschen Kontaktbereiches wird in Abhängigkeit von der Geometrie und der Hertzschen Pressung dargestellt. Die Vergleichsspannung wurde mit der Gestaltänderungsenergiehypothese ermittelt.Die Überlagerung von Normalkraft und Schubkraftbeanspruchung mit im Werkstoff vorhandenen Eigenspannungen wurde für die beiden Fälle Kreis- und Rechteckkontakt durchgeführt. Der Verlauf des Vergleichsspannungsmaximums in Abhängigkeit von den Eigenspannungen mit dem Parameter Reibwert wird dargestellt. Das Ergebnis dieser Berechnungen kann zur Klärung von Oberflächenermüdungsschäden an Wälzlagern, Zahnrädern, Nocken-Stößel-Paarung usw. beitragen.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 434-439 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Strain Measurements of Great Tensile-Test Pieces of Reactor Steel by Holographic InterferometryWith a tensile-test rod of 100 mm diameter the application of holographic interferometry to not vibration isolated mounts has been demonstrated using advanced holographic techniques. The three spatial components of the deformation of an extended part of the rod surface have been calculated and analysed according to a specific deformation behaviour. Especially, it appeared that the strain in the direction of stress showed a discontinuity where later on the rod raptured due to a much greater load.
    Notes: Mit Hilfe fortgeschrittener holographischer Techniken wurde am Beispiel einer 100 mm ∅ Rundzugprobe der Einsatz der holographischen Interferometrie an nicht schwingungsisolierten Aufbauten demonstriert. Die in einem größeren Bereich der Probenoberfläche gemessenen Verschiebungen in den drei Raumrichtungen wurden quantitativ bestimmt und bezüglich spezifischer Deformationen interpretiert. Dabei zeigte sich insbesondere, daß die Dehnung in Zugrichtung einen deutlichen Sprung im Bereich des später, bei sehr viel größeren Belastungen aufgetretenen Bruches aufwies.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A105 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 313-316 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Der Eigenspannungsmeßtechnik wurden in den letzten Jahrzehnten viele Arbeiten gewidmet mit einem Trend der Vorliebe zur röntgenographischen Meßmethode und deren Anwendung. 1979 wurde in einem Symposium der Arbeitsgemeinschaft für Wärmebehandlung und Werkstofftechnik e. V., des Deutschen Verbandes für Materialprüfung e. V. und der Deutschen Gesellschaft für Metallkunde e. V. der Stand der Wissenschaft zum Thema „Eigenspannungen“, Entstehung, Berechnung, Messung und Bewertung, in Deutschland abgehandelt [1]. Vorgetragen wurden neben der reinen Theorie einige praxisbezogene Studien über Bauteile, bei denen der Verlauf der Eigenspannungen ermittelt und studiert wurde, was in jedem Fall die Zerstörung des Bauteils zur Folge hat.Anwendungen der Eigenspannungsmessung zur Fertigungskontrolle sind in der Literatur selten.Dennoch, neben diesen zum Teil uralten Betrachtungen gibt es in der Praxis Fälle, bei denen der prinzipielle Spannungsverlauf im Bauteil bekannt ist und zur Fertigungskontrolle eine praktisch zerstörungsfreie Eigenspannungsmessung der Oberfläche notwendig ist. Diesen Messungen steht ein grundsätzliches Problem entgegen: Die zu vermessende Oberfläche muß relevant sein für den wahren Spannungszustand des Bauteils. Aber die Oberfläche stellt eine singuläre Zone dar, deren Spannungszustand durch alle oberflächenaktiven Vorgänge verfälscht wird; je zerstörungsfreier das Meßverfahren, umso sensibler ist die Messung gegen die Meßstellen-(Oberflächen-)Singularität. Um nur einige Beispiele von Oberflächensingularitäten bei Stahl zu erwähnen, sei erinnert an Entkohlung, Verfestigung durch Grobzerspanung, Verhärtungen oder Anlasseffekte durch Schleifen usw., wobei der Gradient der jeweiligen Beeinflussung von vielen Parametern abhängt und im Regelfall unbekannt bleibt.In dieser Arbeit soll berichtet werden, wie und mit welchem Aufwand für einen speziellen Anwendungsfall das Problem der Meßstellenrelevanz gelöst wurde.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 361-369 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Surface-Specific Analytical Methods (AES/SAM, ESCA/XPS, SIMS) for the Investigation of Wear-Resistant CoatingsThis paper gives a brief review of the analytical possibilities by combining some analytical methods of surface analysis for the study of the uppermost layers of atoms of technical interesting materials (metals).The physical fundamentals, limitations and differences of the methods: Auger electron spectroscopy, X-ray photoelectron spectroscopy and secondary ion mass spectrometry are discussed - especially in comparison with the well-known electron microprobe analysis. Finally the application of surface analysis for the characterization of the chemical surface composition of wear-resistant coatings before and after tribological operation is demonstrated.
    Notes: Es werden die analytischen Möglichkeiten aufgezeigt, die sich ergeben, wenn man mehrere oberflächenspezifische Analysenverfahren, hier speziell AES/SAM, ESCA(XPS) und SIMS, zur Charakterisierung von Werkstoffoberflächen kombiniert einsetzen kann.Die Grundprinzipien werden besprochen, die Vor- und Nachteile der Methoden miteinander verglichen - insbesondere in bezug auf die klassische Röntgen-Mikroanalyse - und schließlich anhand von Beispielen aus dem tribologischen Bereich erläutert.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A23 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: No. Abstract.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 77-80 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Reference series of radiographs of casting defects in chemical apparatus made of grey cast ironChemical apparatus of grey cast iron as reaction vessels or storage tanks continue to be of major importance. When subjected to corrosive attack, they must not show excessive casting defects, otherwise the wall thickness will be reduced too much locally. Radiographic testing is generally used for the quality inspection of such apparatus. In order to evaluate casting defects in radiographs, a reference series of radiographs was produced and its system discussed. This series enables not only an evaluation of radiographs, but also makes it possible to fix quality requirements.
    Notes: Chemieapparate aus Gußeisen mit Lamellengraphit als Reaktionsgefäße oder Lagerbehälter haben nach wie vor erhebliche Bedeutung. Bei korrosiver Beanspruchung dürfen sie keine zu großen Gußfehler aufweisen, da sonst die Wanddicke lokal zu sehr geschwächt wird. Zur Qualitätsprüfung derartiger Apparate ist die Durchstrahlungsprüfung gebräuchlich. Um die Bewertung von Gußfehlern in Durchstrahlungsaufnahmen zu vereinheitlichen, wurde eine Durchstrahlungsbilder-Vergleichsreihe geschaffen, deren System erörtert wird. Diese Reihe erleichtert nicht nur die Beurteilung von Durchstrahlungsaufnahmen, sondern ermöglicht auch die Festlegung von Qualitätsanforderungen.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 109-112 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. A32 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 116-119 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Methoden der Bestimmung von Fließkurven im ZylinderstauchversuchDer Stauchversuch dient vor allem zur Aufnahme von Fließkurven im Bereich hoher Umformgrade. Es werden drei Grundformen des Zylinderstauchversuches beschrieben: Stauchen herkömmlicher Proben mit Schmierung, Stauchen von Rastegaev-Proben mit Schmiertaschen und Stauchen mit Haftreibung. Jede der drei Methoden bietet spezifische Vorteile. So bleibt z. B. beim Rastegaev-Versuch die Probe bis zu einem hohen Umformgrad zylindrisch, aber der Beitrag der Reibung zur Gesamtarbeit ist merklich. Demgegenüber ist bei Haftreibung die Reibarbeit gleich Null, aber die Probe weicht stark von der Zylinderform ab (Aufbauchen). Es werden Vorschläge gemacht zur Vereinheitlichung der drei Versuche.
    Notes: The upsetting test is mainly used for determining stress-strain curves in the range of high strains. Three modifications of the upsetting test are described: upsetting conventional lubricated specimens, upsetting Rastegaev specimens with end recesses, and upsetting under sticking friction conditions. Each of these procedures offers special advantages. For example, in the Rastegaev test, the specimen remains cylindrical up to a high strain while the work required for friction cannot be neglected. By upsetting under sticking friction conditions, no work is required for friction, but the specimen's shape deviates strongly from that one of a cylinder (barrelling). Proposals are made concerning unified procedures for carrying out the tests.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 168-176 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Development and construction of a new type, design-approved tank container for boron-tri-fluoride and other highly compressed gasesA new type of tank container was developed and tested during a period of about two years and approved by the Bundesanstalt für Materialprüfung (BAM) for transporting boron-tri-fluoride and nitrogen. The total weight of this tank container is about 1500 kg and its capacity about 450 litres. This tank container - in comparison to single pressure gas bottles - allows the transport of larger quantities and shall replace gas bottles or bottle batteries in a safe way or shall be used as a supplement to them. Since the container is mounted on a supporting structure, it can be moved by fork lifters, fork-lift trucks or cranes. The transport can be made by truck, rail or ship.
    Notes: In etwa 2 Jahren wurde ein neuartiger Tankcontainer entwickelt, geprüft und von der Bundesanstalt für Materialprüfung (BAM) für den Transport von Bortrifluorid und Stickstoff zugelassen. Das Gesamtgewicht dieses Containers beträgt etwa 1500 kg, das Fassungsvermögen etwa 520 Liter. Der Tankcontainer, der gegenüber der einzelnen Druckgasflasche den Versand von größeren Mengen erlaubt, soll auf sichere Weise Flaschen oder Flaschenbatterien ersetzen bzw. ergänzen. Der Container läßt sich aufgrund seines Gestells mit Gabelstaplern, Gabelhubwagen oder Kränen bewegen, der eigentliche Transport kann dann mit LKW, Bahn oder Schiff erfolgen.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982) 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Stress/strain properties of PTFE skived film over a temperature range of +25 °C to -80 °C and the problem of notch effectChemical plant under severe corrosive stress can be protected with “made-to-measure” liners welded up from PTFE skived film. For correct manufacture, handling and use of these chemical plant linings, a thorough knowledge of the semi-finished product and particularly of its load/deformation properties over a wide temperature range is required. The present paper deals with questions of strength and ductility and with the problem of notch effect at temperatures below + 25 °C. It is based on tensile tests carried out on PTFE skived film. Defined punched and cut notches were used to obtain information on notch sensitivity below room temperature. As the tests relate to two very different skived films, the reasons for these differences are analysed. The part played by the degree of crystallinity in determining many property differences is examined more closely with special reference to its effect on ultimate tensile strength, ductility and notch sensitivity. The aim of this study is not to determine material constants for PTFE but to identify tendencies in the behaviour of the semi-finished product, PTFE skived film, and so to gain useful information for its use in chemical plant lining.
    Notes: Extrem korrosiv beanspruchte Apparate der Chemietechnik lassen sich mit Korrosionsschutzlinern, die maßgerecht aus PTFE-Schälfolie geschweißt werden, schützen. Für werkstoffgerechte Herstellung, Handhabung und Einsatz dieser Apparateauskleidungen sind fundierte Kenntnisse des zu verarbeitenden Halbzeugs, besonders seines Kraft-Verformungs-Verhaltens über einen weiten Temperaturbereich, erforderlich. Die vorliegende Arbeit befaßt sich mit Festigkeits- und Duktilitätsfragen sowie dem Problem der Kerbwirkung bei Temperaturen unterhalb + 25 °C. Sie basiert auf Zerreißversuchen an Proben aus PTFE-Schälfolie. Definierte Stich- und Schnittkerben sollen Hinweise über die Kerbempfindlichkeit unterhalb Raumtemperatur geben. Da sich diese Untersuchung mit zwei sehr unterschiedlichen Schälfolienqualitäten befaßt, erfolgt eine Analyse der Ursachen für diese Unterschiede. Der Kristallinitätsgrad als Einflußgröße auf viele Eigenschaftsunterschiede wird speziell hinsichtlich seiner Auswirkung auf Bruchfestigkeit, Duktilität und Kerbempfindlichkeit näher betrachtet. Diese Untersuchung hat nicht zum Ziel, absolute Werkstoffkennwerte von PTFE zu ermitteln, sondern Trends im Werkstoffverhalten des Halbzeugs PTFE-Schälfolie zu erkennen und damit nützliche Hinweise für den apparatetechnischen Einsatz zu erhalten.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 13 (1982), S. 244-253 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Size Effect in the Low-Cycle Fatigue RegimeThis paper reports the results of the investigations on the problems of conversion of low-cycle fatigue data obtained with small specimens to large structures. Strain controlled fatigue tests have been carried out on specimens of various thickness in push-pull and reversed bending to investigate the geometrical and technological size effect on low-cycle fatigue life Ncr. It was found that a remarkable size effect exists in both loading conditions in LCF-regime. The relationship between materials characteristics (grain size, yield strength), specimen geometry (diameter or area of the cross section) and the fatigue life Ncr was obtained for various loading types and strain levels. Metallurgical and fracture mechanical aspects are considered to explain the size effect in LCF-regime.
    Notes: In der vorliegenden Arbeit wird über Untersuchungen zur Frage der Übertragbarkeit von Ergebnissen an kleinen Proben auf Bauteile bei Beanspruchungen im LCF-Bereich berichtet. Dazu sind Versuche unter Zug-Druck- und Biegewechselbeanspruchung zum geometrischen und technologischen Größeneinfluß durchgeführt worden. Die Ergebnisse wurden in Form von Beziehungen zwischen Werkstoffkenngrößen (Korngröße, Streckgrenze), Bauteilgrößen (Probendurchmesser, Probenquerschnitt) und der zu erwartenden Lebensdauer (kritische Schwingspielzahl) unter Berücksichtigung der Beanspruchungsart und Beansprunchungshöhe aufgestellt. Zur Klärung des Größeneinflusses im LCF-Bereich wurden sowohl werkstoffkundliche als auch bruchmechanische Gesichtspunkte herangezogen.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...