Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2020-2022
  • 1995-1999  (2,501)
  • 1975-1979  (3,851)
  • Analytical Chemistry and Spectroscopy  (5,541)
  • Electron microscopy
Material
Years
Year
  • 1
    ISSN: 1432-1106
    Keywords: Key words Acetylcholine receptor ; Nicotinic ; Denervation supersensitivity ; Neuromuscular junction ; α-Bungarotoxin ; Immunocytochemistry ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Through the use of biotinylated-bungarotoxin and monoclonal antibodies, the nicotinic acetylcholine receptor (nAChR) was localized in the subneural apparatus of mammalian motor end plates of the flexor digitorum brevis muscle of the adult rat at the light and electron microscopic levels. Under normal conditions, nAChR was located in the primary post-synaptic membrane of the neuromuscular junction, and the depths of the junctional folds constituting the secondary post-synaptic membrane did not contain any nAChR. Up to 75 days after repeated transection of the related motor nerve (sciatic), there was no major alteration in the light-microscopic localization of junctional nAChR in the subneural apparatus, except for a moderate shrinkage and increased immunocytochemical reactivity of the subneural apparatus. At the electron microscopic level, however, immunocytochemical reactivity gradually occupied the entire extent of the secondary post-synaptic membrane, including the depths of the junctional folds, which exhibited extensive branching. In non-innervated portions of the muscle fibers, nAChR receptor appeared in a linear localization on the surfaces of denervated muscle fibers. This linear reaction was not continuous with the nAChR reaction of the motor end plates. It is concluded that denervation supersensitivity might not be due to spreading of junctional nAChR from the end-plate area, but rather to expression of nAChR in non-innervated portions of the muscle fiber and to the infraterminal (subsynaptic) spreading of nAChR into the depths of junctional folds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1437-773X
    Keywords: Key words Gastrointestinal stromal tumor ; Gastrointestinal autonomic nerve tumor ; Electron microscopy ; Immunohistochemistry ; Gastrointestinal tract
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Sixteen gastrointestinal stromal tumors (GISTs) were studied by immunohistochemical analysis and an ultrastructural procedure. The tumor locations were as follows: esophagus (2), stomach (7), small intestine (3), and large intestine (4). Four of the lesions were classified as malignant, 2 as borderline, and 10 as benign. On the basis of the immunohistochemical analysis, the tumors were classified as follows: 1 as myogenic type, 2 as Schwann cell type, 8 as Cajal cell type (including 2 gastrointestinal autonomic nerve tumors, GANTs), and 5 as mixed-cell type. In each subtype the phenotype was compared to the ultrastructural findings. Myogenic and Schwann cell type revealed ultrastructurally smooth muscle differentiation and schwannian tumor. All 8 tumors of the Cajal cell type revealed interdigitating cytoplasmic processes with occasional clusters of filopodia. Two tumors were subdivided as GANT. Five tumors of mixed-cell type were composed of a mixture of cells with variable myogenic features or variable neural differentiation. We confirmed in this study that immunohistochemical analysis reflected electron microscopic findings.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical electron microscopy 32 (1999), S. 209-212 
    ISSN: 1437-773X
    Keywords: Key words Keratin ; Bile canaliculi ; Ecto-ATPase ; Transgenic mice ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Keratin 8 (K8) and keratin 18 are the intermediate filament proteins that are expressed in hepatocytes. A K8-deficient FVB/N mouse is a unique animal model for assessing the contribution of keratin intermediate filaments (IFs) to the structural and functional integrity of hepatocytes. Hepatocytes from homozygous (−/−) K8-deficient mice manifest a reduced bile acid secretion and an increased fragility to mechanical stress and hepatotoxic drugs. Hepatocytes from heterozygous (+/−) mice are more susceptible to drug-induced injury. Immunofluorescent microscopy revealed that hepatocytes from (+/−) mice maintained K8 IFs and F-actin that are similar to those in wild-type (+/+) mouse hepatocytes. In (−/−) mouse hepatocytes, K8 protein was negative and F-actin presented a coarse and irregular pattern. Ecto-ATPase, detected by enzyme histochemistry and observed by electron microscopy, was reduced in the bile canaliculi of both (+/−) and (−/−) mouse livers, in comparison with that of (+/+) mouse livers. These results reveal for the first time different microscopical findings regarding the livers of these three genotypes. They also suggest that the reduction of ecto-ATPase plays a role in the increased fragility of (+/−) and (−/−) mouse livers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1437-773X
    Keywords: Key words Small cell neuroendocrine carcinoma ; Parotid gland ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A case of small cell neuroendocrine carcinoma of the parotid gland is presented with immunohistochemical and electron microscopic studies. Small cell neuroendocrine carcinoma is extremely rare and is often difficult to distinguish from malignant lymphoma, adenoid cystic carcinoma, and undifferentiated carcinoma. Under light microscopy, the tumor cells consisted of solid sheets and nests of small tumor cells. Immunohistochemically, they were positive for KL-1 and EMA, and focally positive for NSE and synaptophysin. Observation using an electron microscope showed membrane-bound neuroendocrine granules in some tumor cells. Histological evaluation indicated that the present case was small cell carcinoma of the parotid gland, showing a neuroendocrine variety.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical electron microscopy 32 (1999), S. 167-174 
    ISSN: 1437-773X
    Keywords: Key words Apoptosis ; Docetaxel ; Human leukemia cell ; DNA fragmentation ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We induced apoptosis in cells of the human leukemia cell line HL-60 using an antitumor agent, docetaxel (Taxotere), and investigated apoptosis in various aspects using in situ end-labeling (ISEL) of DNA, DNA fragmentation assay, flow cytometry, and electron microscopy. Because it inhibits depolymerization of tubulin, docetaxel is thought to arrest the cell cycle at the mitotic stage and to exert an antitumor effect. In this study, accumulation of docetaxel-treated cells at the G2/M phase was detected using flow cytometry. On ISEL of DNA, DNA fragmentation was observed at the mitotic stage. On electron microscopy, the nuclei of apoptotic cells lost their nuclear membranes, as do cells at mitosis, demonstrating that the cells were arrested mainly at the M phase in the cell cycle.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-2307
    Keywords: Key words Melanin ; Oncocytic metaplasia ; Nasopharynx ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  A 64-year-old man presented with a history of discomfort of the throat of a few weeks’ duration. Nasoscopic examination revealed multiple small, brown pigmentations at the left suprapharynx, the base of the left nasal cavity and the pharyngeal openings of the auditory tube on both sides. Microscopically, the lesion showed a glandular pattern of oncocytic epithelium with abundant pigmented granules and melanophages in the surrounding stroma. Immunohistochemically, the dendritic cells in the basal layer were positive for S-100 protein. Electron microscopic study revealed numerous fully melanized melanosomes and hypertrophied mitochondria in the oncocytic cells. Oncocytic cells do not produce melanin for themselves, melanin granules apparently being transferred from the adjacent dendritic cells to the oncocytic cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Anatomy and embryology 200 (1999), S. 551-558 
    ISSN: 1432-0568
    Keywords: Key words Retina ; Development ; Retinal pigment epithelium ; Microglia ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Blood-borne mononuclear cells invade the developing retina via the hyaloid vasculature at the optic nerve head. Following removal of apoptotic cell debris they give rise to the network of resident microglia. The population of cells recently described in the peripheral subretinal space of developing human eyes may represent a further population of macrophages destined to become microglia. The aim of the present study was to confirm the presence of subretinal macrophages in the developing eye in other mammalian species and perform preliminary immunophenotypic analysis in rat tissues. The range of species chosen included eutherian mammals (rat and rabbit) and marsupials (wallaby and opossum). Ocular tissues from a range of developmental stages were studied by scanning electron microscopy and transmission electron microscopy. Distinctive networks of dendriform and pleomorphic macrophages were observed by scanning electron microscopy in the peripheral subretinal space of D2 rabbits, newborn and D2 rats and D75 wallaby. Transmission electron microscopic studies of D2 rabbit, newborn and D2 rat and all ages of North American opossum revealed cells with the ultrastructural features of macrophages in the peripheral subretinal space, cilio-retinal junction and between ciliary epithelial cells. Preliminary immunoperoxidase studies using a panel of anti-leukocyte monoclonal antibodies on frozen sections of rat ocular tissues (newborn, D2 and D4) revealed ED1+ Ox42+ ED2+ but Ox6– cells in the peripheral subretinal space, peripheral retina and ciliary body epithelia. The data confirms that subretinal macrophages are a feature of the developing eye in a broad range of mammalian species and immunophenotypic evidence leads the author to postulate that these cells arise from the ciliary body vasculature and may migrate into peripheral neural retina and mature into resident microglia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Acta neuropathologica 98 (1999), S. 645-650 
    ISSN: 1432-0533
    Keywords: Key words Amyotrophic lateral sclerosis ; Autopsy ; Electron microscopy ; Immunocytochemistry ; Motor ; neuron disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report two autopsy cases of motor neuron disease (MND) patients with an unusual type of muscular atrophy predominantly affecting the shoulder girdle and the upper extremities with proximal dominance. Both patients are considered to be clinically categorized into the El Escorial suspected form of amyotrophic lateral sclerosis (ALS). At autopsy, they showed marked loss of spinal anterior horn cells accompanied by astrogliosis positively immunostained with anti-glial fibrillary acidic protein antibody at the cervical level. At the lumbosacral level, anterior horn neurons were relatively well preserved and Bunina bodies, ubiquitin-positive skein-like inclusions and Lewy body-like inclusions were observed in the remaining neurons. In one patient, brain stem motor neurons (nerves V, VII, XII) and motor cortex, including Betz cells, were also affected and the corticospinal tracts were degenerated at the level of the thoracic and lumbar spinal cord. Pathological findings of this patient are consistent with those of ALS. In the other patient, the motor cortex, brain stem motor nuclei and the corticospinal tracts were well preserved, which is pathologically compatible with progressive spinal muscular atrophy. These patients with such a peculiar pattern of progressive muscular atrophy should be placed in a subgroup of ALS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-0568
    Keywords: Key words Vomeronasal organ ; Microvilli ; Monoclonal antibody ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  The development of the rat vomeronasal organ was studied morphologically and immunocytochemically, using the monoclonal antibodies (MAbs) VOBM1, VOBM2 and VOM2 that react with the luminal surface of the vomeronasal sensory epithelium. Postnatal day (P) 7, 14, 21, 28, 35 and adult animals were examined. The vomeronasal organ and the blood vessel of the organ markedly increased in size and the vomeronasal glands increased in number between P7 and P14. At P35, the shape of the vomeronasal organ was similar to that of the adult but its size was slightly smaller. Electron microscopy showed that only a few scattered microvilli were present on supporting cells, and receptor cells were immature at P7. At P21, well-branched microvilli of the receptor cells and many microvilli of the supporting cells were observed on the luminal surface of the sensory epithelium. At P35, most apical endings of supporting cells and receptor cells were covered with numerous microvilli. Less developed areas were also present at the luminal surface of the epithelium at P35. At P7, immunoreactivities of the three antibodies were observed as discontinuous thin-layered bands only on the luminal surface of the sensory epithelium and no immunoreactivity was observed in other regions of the vomeronasal organ. Immunoreactivities of the VOBM1, VOBM2 and VOM2 increased with age and were observed as continuous thin-layered bands on the luminal surface of the epithelium by P35. These finding suggest that the development of the vomeronasal organ continues after birth and that the organ may reach maturity just before puberty (P42–49).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0533
    Keywords: Key words Unmyelinated fibers ; Peripheral nerve ; Electron microscopy ; Histochemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Quantitation of unmyelinated fibers (UF) in peripheral nerves has classically relied upon ultrastructural morphometry. Because this method is time-consuming, it is not typically performed in routine analysis of nerve biopsies. We applied the Bodian-Luxol technique to detect unmyelinated axons by light microscopy on semithin sections from resin-embedded nerve tissue. Estimates were compared to ultrastructural counts. The staining appeared highly specific for axons. Excellent correlation was found between optic densities and the population of UF larger than 0.5 μm. The smallest profiles detected by light microscopy had a diameter close to 0.6 μm. This new technique is not a substitute for ultrastructural quantitative morphometry of UF, as very small unmyelinated axons, especially regenerating ones, can not be reliably visualized. However, it provides a valuable light microscopic method for evaluating axonal loss among UF.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Acta neuropathologica 98 (1999), S. 330-336 
    ISSN: 1432-0533
    Keywords: Key words Micropolygyria ; Electron microscopy ; Frontal lobe ; Perivascular space ; Dot-like structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We have reported breaches of glia limitans (GL)-basal lamina (BL) complex with protruding neuroglial tissue in Fukuyama-type congenital muscular dystrophy (FCMD) fetus brain and suggested that some basic deficits in the GL-BL complex may have a pivotal role in formation of micropolygyria in FCMD. We therefore investigated the cerebral GL-BL complex in seven FCMD cases (12–27 years of age), in three cases of Duchenne muscular dystrophy (17–25 years of age) and in two non-neurological controls (28 and 33 years of age). The frontal lobe cortex was examined immunocytochemically using antibodies against collagen type IV and laminin in each case, and ultrastructurally in an adult case of FCMD. In FCMD, the BL of the cortical surface was frequently breached with protruding neural tissue that ultrastructurally showed frequent synapses, neurites that had parallel arranged microtubules, and astrocytic processes. The outermost surface of this tissue was only partly lined by a BL. In the region of the gyral adhesion of micropolygyria, the perivascular space of the apparently entrapped meningeal blood vessels was occupied by neuroglial tissue, which is assumed to have invaded through the occasionally seen breaches of the perivascular GL-BL complex. Electron microscopy of the intruding tissue showed frequent synapses, microtubule-containing neurites and astrocytic processes. No breached GL-BL complex was found in any of the non-FCMD cases. These findings indicate that in FCMD, the cerebral GL-BL complex continues to have a crucial deficit with resulting breaches through which neuroglial tissue protrudes, promoting adhesion of the adjacent cerebral gyri during brain development before and after birth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Anatomy and embryology 199 (1999), S. 459-469 
    ISSN: 1432-0568
    Keywords: Key words Differentiation ; Electron microscopy ; Histochemistry ; Microtubules ; Neurofilaments
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  The organization of the cytoskeleton has been studied during mouse differentiation in cells of the myenteric neuronal lineage. The entire gut was examined starting from day 12.5 of embryonic life (E12.5) until birth (P0). Immunocytochemistry was performed to evaluate the expression of five of the most represented neurofilaments proteins (the low, NF-L, medium, NF-M, and heavy, NF-H, molecular weight subunits, α-internexin and peripherin) and of two of the microtubule-associated proteins (MAP1 and MAP2a+2b). In parallel, the appearance in the differentiating myenteric neurons of filamentous and microtubular structures and their intracytoplasmatic distribution were observed under the electron microscope. A differential immunohistochemical expression of the structural proteins was found. Immature cells expressed α-internexin, peripherin, NF-M and MAP1 by day E12.5; α-internexin expression was strong in these cells, but gradually decreased with age and was practically absent in adulthood. Conversely, the expression of the other three proteins increased with cell differentiation and was still present in adulthood. NF-L and NF-H expression appeared later, by day E16.5, and was weak for the entire pre- and postnatal life. MAP2a+2b was never expressed. Under the electron microscope, at day E12.5 the cytoskeleton was already organized in filamentous and microtubular structures. At this age neurofilaments were few and mainly located in the cell processes, and microtubules were numerous and mainly assembled in the neuritic growth cones, together with synaptic vesicles. With ageing, neurofilaments and microtubules were ubiquitous in the neuron. Data obtained demonstrate that cytoskeletal proteins gradually accumulate in the cells of the neuronal lineage in parallel with the organization of the cytoskeletal structures, which in turn mediate important neural events by the earliest stages of murine embryonic life, including growth of nerve processes and initiation of axonal transport.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 125 (1999), S. 19-27 
    ISSN: 1432-1106
    Keywords: Key words Nerve injury ; Nerve repair ; Retrograde reaction ; Regeneration ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Peripheral axotomy of adult cat spinal motoneurons induces a marked loss of synaptic boutons from the cell bodies and dendritic trees. The aim of the present study was to analyze the recovery of synaptic contacts in axotomized motoneurons following reinnervation into muscle. Adult cat spinal motoneurons were first deprived of their muscular contacts for 12 weeks and, then, allowed to reinnervate their target muscle. Two years later, regenerated motoneurons were labeled with horseradish peroxidase to allow quantitative ultrastructural analyses of the synaptic covering of the cell bodies and dendrites. Presynaptic boutons were classified according to their size and the shape of their synaptic vesicles. Results show that a recovery of synaptic covering occurs in the axotomized neurons after muscle reinnervation, but it affects various bouton types to different degrees. The number of S-type boutons synapsing with the soma was 70% higher after reinnervation than at 12 weeks after axotomy, while the number of F-type boutons had increased by only 13%. Compared with the normal situation, the number of S-type boutons synapsing with the proximal dendrites increased from 82% at 12 weeks after axotomy to 180% in the reinnervated state. In conclusion, in adult cat spinal motoneurons, the reestablishment of muscular contact is followed by a normalization of some of the synaptological changes induced by a prolonged state of axotomy. In certain respects restitution is incomplete, but in others it results in overcompensation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    European biophysics journal 28 (1999), S. 263-267 
    ISSN: 1432-1017
    Keywords: Key words Human liver ; Human brain ; Ferritin ; Electron microscopy ; Mössbauer spectroscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Notes: Abstract Human brain (globus pallidus) and liver tissues were investigated by means of electron microscopy (EM), Mössbauer spectroscopy (MS) and SQUID magnetometry techniques. Based on MS measurements, the iron present was identified to be in the ferritin-like form (61–88%) and in the form of a low-spin iron species (the balance). Its overall concentration was estimated as 1.5(3) mg in the brain and 2.4(5) mg in the liver, per gram of lyophilized tissue. The average core diameter was determined by EM measurements to be equal to 7.5(1.3) nm for the liver and 3.3(5) nm for the brain. Magnetization measurements carried out between 5 and 300 K yielded an estimation of an average blocking temperature, KT BL, as equal to 6.7 K and 8.5 K for the liver and the brain, respectively. From the dependence of KT BL on the external magnetic field it was concluded that the ferritin-like cores in the studied samples can be regarded as non-interacting particles. Finally, the uniaxial magnetic anisotropy constant was determined to be 6×103 J/m3 for the liver and 4×104 J/m3 for the brain.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1432-1459
    Keywords: Key words CADASIL ; Cerebrovascular disease ; Skin biopsy ; Muscle biopsy ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a microangiopathic syndrome. Although the defective gene has been identified, genetic analysis may be effort some due to its large size and various mutations. Providing a reliable diagnostic marker would therefore be helpful. Electron microscopy has revealed characteristic electron-dense granular deposits in the basal lamina of vessels of patients with CADASIL. We investigated the sensitivity of skin and muscle biopsies for diagnosing CADASIL. We examined 30 family members of three unrelated German families affected by CADASIL. In 14 of the 21 affected individuals we performed skin and muscle biopsies; two patients were clinically asymptomatic. Under electron microscopy all muscle and skin biopsy specimens showed patches of granular and electron-dense material in the basal layer of both arterioles and capillaries. These findings confirm that general microangiopathy is a typical feature of this syndrome and is present in the early phase of the disease with or without clinical manifestation. Thus, as electron microscopy of skin biopsy specimens can establish the diagnosis of CADASIL with high certainty, it may be considered the method of first choice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1432-2307
    Keywords: Key words Rhabdomyosarcoma ; Aorta ; Immunohistochemistry ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  We report an intimal sarcoma presenting as an aortic aneurysm. A 68-year-old man suffered from chest pain and speech disturbance. Computed tomography showed a sacciform aneurysm of the aorta, which was resected, revealing a polypoid tumour measuring 1.5×2×2.5 cm projecting into the lumen. This proved to be a poorly differentiated high-grade sarcoma having morphological, immunophenotypic and ultrastructural features consistent with rhabdomyosarcomatous differentiation. Primary sarcomas of the aorta are extremely rare. Many cases have been diagnosed as ”intimal” on the basis of their site of origin, and they are not easy to classify from their histological pattern. Electron microscopy and the use of a more comprehensive panel of immunohistochemical markers should be applied in the histological classification of ”intimal” sarcoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1432-0878
    Keywords: Key words Descending contralateral movement detector (DCMD) ; Identified neuron ; Vesicles ; Electron microscopy ; 3-D reconstruction ; Locust ; Schistocercagregaria (Insecta)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract  The descending contralateral movement detector (DCMD), an identified descending interneuron in the brain of the locust Schistocerca gregaria has been investigated by using light and electron microscopy. We describe the fine structure, distribution and numbers of synapes that it receives from another identified brain neuron, the lobular giant movement detector (LGMD), and from unidentified neurons. The DCMD dendrites emerging from the integrative segment vary in form and number between individuals and sexes but always form a flattened dendritic domain. The arborizations and the integrative segment appear to be exclusively postsynaptic. Two types of synaptic contacts (Type 1 and 2) onto the DCMD can be discerned as having either round (Type 1) or pleiomorphic synaptic vesicles (Type 2) and by large (Type 1) or small (Type 2) subsynaptic appositions. Contact zones of Type 1 synapses are smaller than those of Type 2. LGMD-synapses are of Type 1 and occur intermingled with presynaptic sites of unidentified units. Some branches of the DCMD receiving input from unidentified units are devoid of contacting LGMD processes. Synapses of both types are randomly distributed over the DCMD integrative segment and at fibres with similar sizes.Type 1 synapses are much more frequent than Type 2 synapses and their number is negatively correlated with fibre diameter. For a whole DCMD dendritic arborization, a total of 8500 active zones of chemical synapses has been calculated, including a mininum of 2250 LGMD-synapses and about 1000 Type 2 synapses. The DCMD may thus receive a considerable amount of input from as yet unidentified neurons.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 296 (1999), S. 359-369 
    ISSN: 1432-0878
    Keywords: Key words Apoptosis ; Electron microscopy ; Meiosis ; Spermatocytes ; Spermatogenesis ; Testis ; TUNEL ; Mouse (10 strains)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract  Apoptosis of male germ cells is a widespread but little-understood phenomenon in many animal species. The elucidation of its mechanisms could be useful in the understanding of male infertility. We have examined the distribution of dying cells with the terminal transferase-mediated nick-end labeling (TUNEL) method and by an electron-microscopic procedure in the testes of 10 mouse strains, viz., C57BL/10 (B10), SL/NiA (SL), C57BL/6 (B6), C3H/He (C3H), BALB/c (BALB), DBA2 (DBA), CBA/J (CBA), MRL/MpJ-+/+ (M+), MRL/MpJ-lpr/lpr (lpr), and wild-type NJL mice (Mus musculus musculus). In the testes of the B10, NJL, SL, B6, C3H, BALB, DBA, and CBA mice, very few TUNEL-positive cells are distributed in the seminiferous tubules, whereas in the testes of the M+ and lpr mice, many TUNEL-positive cells, which are restricted to stage XII seminiferous tubules, have been identified. The most important finding is that many metaphases of meiotic spermatocytes show a marked TUNEL-positive reaction. Some metaphases show apoptotic morphology electron-microscopically. These results suggest that the testes of MRL strains will provide a useful model for the study of the mechanism of metaphase-specific apoptosis in meiotic spermatocytes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1432-0878
    Keywords: Key words Neuromelanin ; Neuron ; Peroxidase ; Oxygen metabolism ; High-definition light microscopy ; Electron microscopy ; Ultrastructure ; Cytochemistry ; Substantia nigra ; Lumbricusterrestris (Annelida)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Histochemical examination of 1-μm tissue sections from the dorsal nerve plexus of the earthworm, Lumbricus terrestris, reveals multiple brown intraneuronal granules. These granules contain material morphologically and histochemically consistent with neuromelanin. When viewed with transmission electron microscopy, these were seen as single membrane-enclosed biphasic granules with diameters of 370–730 nm. Exposure of L. terrestris to high-level environmental oxygen resulted in an increase in the number of neuromelanin-like pigment granules within the neurons of the circular muscle layer. As measured by ortho-phenylenediamine hydrochloride, the endogenous peroxidase activity of extracts from worms incubated in high-level environmental oxygen was 51% more than controls. The endogenous peroxidase activity was localized in situ with 3,3-diaminobenzidine (DAB) and was found to increase in and around the neuromelanin-like pigment-containing neurons within the circular muscle layer. These studies suggest that the nerve net of L. terrestris may serve as a model to study the role of neuromelanin production in oxidative stress and its relationship to endogenous peroxidases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1432-0878
    Keywords: Key words Immunohistochemistry ; Electron microscopy ; Interstitial cells of Cajal ; F4/80 ; CSF-1 ; Kit-receptor ; Mouse (op/op)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The osteopetrotic (op/op) mutant mouse possesses an inactivating mutation in the colony-stimulating factor-1 (CSF-1) gene, which results in the absence of certain macrophages and in osteopetrosis, following a lack of osteoclasts. Studies of the op/op mouse indicate that CSF-1-dependent tissue macrophages may belong to a trophic and/or scavenger subpopulation, which through their effect on other cell types can significantly affect tissue functions, and that cells which are CSF-1 independent have antigen presentation and immunological functions.We have previously identified a cell system of regularly distributed macrophages in the muscularis externa of the small intestine and wanted to extend these studies to the op/op mouse.The present investigations with light- and electron-microscopic methods using fluorescent dextran, methylene blue and immunohistochemistry (F4/80, anti-kit receptor, anti-CD3, anti-CD45R/B220) show that macrophages are absent from the muscle layers, with only an occasional macrophage present in the subserosa. In the lamina propria and submucosa, macrophage numbers are reduced. In all other respects the muscularis externa appears normal, including normal organization and number of interstitial cells of Cajal. Control and op/op mice both lack cells expressing CD3 (T lymphocytes), CD45R/B220 (B lymphocytes) and mast cells in the muscularis externa. This leaves the muscularis externa macrophages as the most likely source of local cytokine production under such conditions as postoperative ileus and intussusception in infants, where the muscularis externa appears to be one target of cytokines. We conclude that the lack of macrophages, combined with the preservation of otherwise normal structure, will make the op/op mouse a valuable model by which to assess the functions and relative importance of the muscularis externa macrophages in relation to intestinal motility under normal and pathological conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    ISSN: 1432-0878
    Keywords: Key words Caveolin ; Caveolae ; Lung ; Alveolar epithelial type I cell ; Immunocytochemistry ; Electron microscopy ; Confocal laser scanning microscopy ; Rat (CD)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Caveolae are flask-shaped invaginations of the plasmalemma which pinch off to form discrete vesicles within the cell cytoplasm. Biochemically, caveolae may be distinguished by the presence of a protein, caveolin, that is the principal component of filaments constituting their striated cytoplasmic coat. Squamous alveolar epithelial type I (ATI) cells, comprising approximately 95% of the surface area of lung alveolar epithelium, possess numerous plasmalemmal invaginations and cytoplasmic vesicles ultrastructurally indicative of caveolae. However, an ultrastructural appearance does not universally imply the biochemical presence of caveolin. This immunocytochemical study has utilised a novel application of confocal laser scanning and electron microscopy unequivocally to localise caveolin-1 to ATI cells. Further, cytoplasmic vesicles and flask-shaped membrane invaginations in the ATI cell were morphologically identified whose membranes were decorated with anti-caveolin-1 immunogold label. Coexistent with this, however, in both ATI and capillary endothelial cells could be seen membrane invaginations morphologically characteristic of caveolae, but which lacked associated caveolin immunogold label. This could reflect a true biochemical heterogeneity in populations of morphologically similar plasmalemmal invaginations or an antigen threshold requirement for labelling. The cuboidal alveolar epithelial type II cell (ATII) also displayed specific label for caveolin-1 but with no ultrastructural evidence for the formation of caveolae. The biochemical association of caveolin with ATI cell vesicles has broad implications for the assignment and further study of ATI cell function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1435-1536
    Keywords: Key words Double chain surfactants ; Aggregates ; Phase diagrams ; Lamellar phases ; Electron microscopy ; SANS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract We present the phase diagrams and the properties of newly synthesised double-chain cationic N-alkyl-N-alkyl′-N,N-dimethylammonium bromide surfactants [C x C y DMABr (x = 12, 14 and 16; y = 10, 11, 12, 14 and 16)]. All the systems studied form liquid-crystalline lamellar phases but with different morphologies: unilamellar vesicles at low surfactant concentrations, multilamellar vesicles and tubular aggregates for surfactant concentrations between 2 and 10 wt% and at even higher concentrations planar bilayers of surfactant molecules in the classical Lα phase. The phase diagrams were determined with macroscopic and microscopic methods (polarisation microscopy, freeze-fracture transmission electron microscopy, scanning electron microscopy and differential interference contrast microscopy). The properties of the surfactant solutions were determined with differential scanning calorimetry measurements for Krafft point determination and small-angle neutron scattering measurements for interlamellar spacing and bilayer thickness. Finally, conductivity and viscosity measurements for phase characterisation were carried out.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    European journal of epidemiology 15 (1999), S. 175-180 
    ISSN: 1573-7284
    Keywords: Electron microscopy ; Epidemiology ; Non-bacterial Gastroenteritis ; Oyster ; Small round structured viruses (SRSVs)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract From 1987 to 1992, 18 outbreaks of acute non-bacterial gastroenteritis occurred in Kyushu district. The most common symptoms were diarrhea, vomiting, nausea and abdominal cramp. Small round structured viruses (SRSVs) were detected in 52 (44.8%) of 116 stool samples from 17 outbreaks by the electron microscopy (EM) method, and a significant increase in the antibody level was noted in 42 (80.7%) of 52 paired serum samples from 12 outbreaks by the immune electron microscopy (IEM) method and in 18 (51.4%) of 35 samples from 8 outbreaks by the western blot (WB) method. However, according to the WB method, antigen-antibody reaction was not observed to reference antigen strips (SRSV-9/Tokyo 86-510, 63kDa) in three of the 8 outbreaks. The detected virus was regarded as an etiologic agent for these outbreaks. In four of 5 outbreaks which appeared associated with eating raw oysters, there was a close relation between SRSV infection and consumption of raw oysters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 277 (1999), S. 164-173 
    ISSN: 1435-1536
    Keywords: Keywords Nanostructures ; Thin films ; Vapor deposition ; Electron microscopy ; Optical properties
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Colloidal dispersions of Yb, Er and Pr have been prepared by chemical liquid deposition. The metals were cocondensed at 77 K with 2-methoxyethanol and ethanol to produce solvated metal atoms. The particle size of the dispersions was determined by transmission electron microscopy to range from 52 to 1080 Å; the particles had spherical shapes. After solvent evaporation under vacuum, active solids and amorphous powder were deposited over Cu and Al metal. Dispersion stability, particle size, UV/Vis absorption and zeta potential were studied. The solids prepared by solvent evaporation were characterized by Fourier transform infrared (FTIR) spectroscopy and thermogravimetric analysis (TGA). The films prepared on Al were studied by scanning electron microscopy. The most stable colloid was obtained using 2-methoxyethanol: several concentrations were stable for several months and the zeta potential indicated that this colloid stability is mainly due to solvation effects. FTIR spectroscopy of the solids indicated solvent incorporation in the film. This observation was corroborated by thermal analysis. Information on the thermal stability of the films was obtained by TGA. The UV/Vis absorption spectrum was measured at several concentrations under different conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    ISSN: 1434-4726
    Keywords: Key words Laryngeal cancer ; p53 ; Oncoprotein ; Ki67 ; Proliferating cell nuclear antigen (PCNA) ; DNA ploidy ; Electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The difficult and complicated mechanism of cancer development with little knowledge about the biology of existing cancers can lead to a permanent search for new examination techniques to improve the precision of life expectancy in patients and the selection of the most efficient methods of treatment. The aim of this study was to analyze certain prognostic factors, i.e., p53, Ki67, proliferating cell nuclear antigen (PCNA), DNA ploidy and cell proliferating activity, as well as the degree of morphological differentiation and cell maturity evaluated on an ultrastructural level in patients with laryngeal cancers in connection with data obtained from follow-up examinations and the clinical course of the disease. Neoplastic tissue was taken from 120 patients with laryngeal cancers. All underwent surgical treatment, radiotherapy and combined treatment in the Department of Otolaryngology, Karol Marcinkowski University School of Medical Sciences, Poznań, Poland, and the Department of Otolaryngology – Head and Neck Surgery, Haukeland University, Bergen, Norway. Before beginning treatment all patients underwent histological verification of their neoplastic tissues. Histopathological examination proved that the majority of cases (95%) had a squamous cell carcinoma. The occurrence of changes within the lymph nodes of the neck (N) was significantly correlated with T, S, Ki67, metastases to lymph nodes, DNA ploidy, site and surgery performed. The degree of clinical progression (S) was intercorrelated with T, N, p53, Ki67, PCNA, DNA ploidy, site and laryngectomy. The occurrence of oncoprotein p53 in neoplastic cells was measured by the staining degree of their nuclei and was correlated with T, S, DNA ploidy, metastases to lymph nodes, PCNA and site. The degree of staining of neoplastic cells for the nuclear antigen Ki67 was correlated to T, N, G, S, DNA ploidy, metastases to lymph nodes and surgical treatment. The proliferative antigen PCNA in the examined population of patients was intercorrelated with T, p53, Ki67, metastases to lymph nodes and surgical treatment. The results obtained from DNA flow cytometry could be associated with N, G, p53, Ki67 and metastases to lymph nodes. On the basis of the results obtained, the techniques suggested for the morphological and biological evaluation of neoplastic cells in cancer of the larynx should include TNM classification + G + DNA + p53 + Ki67.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 11-16 
    ISSN: 0935-6304
    Keywords: Pyrolysis gas chromatography ; microstructure determination ; syndiotactic copolymers ; styrenes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The composition and microstructure of syndiotactic para-methylstyrene/styrene copolymer was determined by a pyrolysis gas chromatography (Py-GC) method. This method uses the styrene and para-methylstyrene monomer peak intensities to determine the styrene and para-methylstyrene composition in the copolymer. The number average sequence length of styrene was calculated by using the triad peak intensities. Because of the low concentration of para-methylstyrene in the copolymer, the number average sequence length of para-methylstyrene was determined with formulas that incorporate the copolymer composition and the number average sequence length of styrene. The distribution of para-methylstyrene defined by the terms “percent of single units” and “percent of desired distribution” was calculated by the number average sequence of para-methylstyrene. This method has been tested with copolymers containing up to 24 mole% of para-methylstyrene. The composition results from Py-GC of para-methylstyrene and styrene copolymers used in this study were in excellent agreement with 1H-NMR results.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 24-28 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; ECD ; Micro-ECD ; GC detector ; organochlorine pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A new ECD, the HP 6890 Series Micro-ECD, was designed to address inherent deficiencies in classical electron capture detectors (ECD), especially with respect to sensitivity, linearity, dynamic range, and ruggedness. Several novel technologies were incorporated in the totally new design and were refined through practical testing and user feedback. Validation of the micro-ECD performance was accomplished through side-by-side testing of the Micro-ECD with previous ECDs following US EPA Contract Laboratory Program methods for pesticides and PCBs. In addition, extensive interviews were conducted with early users of the Micro-ECD who also had experience with other designs running a variety of ECD methods. The design and resulting performance improvements are described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 33-38 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; chiral separation ; negatively charged chiral selectors ; capillary filling methods ; dual systems ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Data on the use of two chiral selectors, namely 18-crown-6 tetracarboxylic acid and a negatively charged cyclodextrin derivative (sulfated-β-cyclodextrin or carboxymethyl-β-cyclodextrin), in the same background electrolyte are presented. The use of such dual systems has a considerable influence on the resolution, as illustrated for the separation of tryptophan derivatives. Reduction of the consumption of chiral selector without significant loss in resolution was obtained by only partly filling the capillary and applying a run buffer without selector. This is illustrated for the chiral separation of tryptophan hydroxamate and the diastereomeric and enantiomeric separation of the dipeptide α/b-AspPhe-OMe.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 43-46 
    ISSN: 0935-6304
    Keywords: Green and roasted coffee ; diterpenes ; cafestol ; kahweol ; 16-O-methylcafestol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The three coffee diterpenes cafestol, kahweol, and 16-O-methylcafestol are mostly esterified with fatty acids. Little has been published about the diterpenes occurring in the free form. By means of gel permeation chromatography on Bio Beads S-X3, it is now possible to simultaneously analyze and quantify the small amounts of these compounds by RP-HPLC. In this way, free kahweol was first proved to be an ingredient of Robusta coffee. Various Arabica and Robusta coffees - both green and roasted - were investigated. Free diterpenes were found in green coffees in amounts below 200 mg/kg dry matter. In comparison to the respective total diterpene content determined by the same HPLC method after saponification of the coffee oil, the proportion of free diterpenes ranged from 0.7 to 3.5 %. During the roasting process, the three uncombined diterpenes behaved similarly: free 16-O-methylcafestol, cafestol as well as kahweol were degraded with increasing roasting temperature.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 0935-6304
    Keywords: Ethanol ; mobile phase ; factorial planning ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 177-180 
    ISSN: 0935-6304
    Keywords: Fresh water systems ; burbot ; organotin compounds ; speciation analysis ; GC-AED ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 0935-6304
    Keywords: RP-HPLC ; GC-MS ; trioxanes ; thermolysis products ; quantitative analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 0935-6304
    Keywords: Multidimensional Gas Chromatography ; orthogonal separations ; GC×GC ; comprehensive two-dimensional chromatography ; characterization of gasoline ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---In comprehensive two-dimensional gas chromatography (GC×GC), two capillary columns are connected in series through an interface known as a “thermal modulator”. This device transforms effluent from the first capillary column into a series of sharp injection-like chemical pulses suitable for high-speed chromatography on the second column. Dramatic increases in the resolving power, sensitivity, and speed of the gas chromatograph result. This paper describes the development of a robust and reliable thermal modulator for GC×GC.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 74-78 
    ISSN: 0935-6304
    Keywords: Polypeptides ; subcritical fluid chromatography ; supercritical fluid chromatography ; carbon dioxide ; additives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The effect of mobile phase modifier and additive on the chromatographic properties of various small polypeptides was explored under subcritical conditions. A polymeric column was used to separate various enkephalin analogs, bradykinin, and oxytocin using a carbon dioxide-based mobile phase with either an ethanol or a 2-methoxyethanol modifier. The role of the modifier was found to be secondary to that of the mobile phase additive. As progressively stronger acidic mobile phase additives were used, the peak profiles of the various polypeptides improved and retention decreased. Heptadecafluorooctanesulfonic acid was found to be the most useful additive for these types of solutes under near-critical conditions, while the potassium salt of heptadecafluorooctanesulfonic acid failed to elute any of the polypeptides. At low temperatures, pressure gradients with a carbon dioxide/ethanol/heptadecafluorooctanesulfonic acid ternary mobile phase produced reasonably good peak profiles with the polymeric column.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 89-92 
    ISSN: 0935-6304
    Keywords: Enantioselective gas chromatography ; heptakis(2,3-di-O-methyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin ; heptakis(2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin ; γ(δ)-thionolactones ; olfactometry ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The even numbered γ(δ)-thionolactones (C6-C12) were investigated, using heptakis(2,3-di-O-methyl-6-O-tert-butyldimethylsilyl)- and heptakis(2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin as chiral stationary phases in capillary gas chromatography. The odor characteristics of γ(δ)-thionolactone enantiomers were investigated by enantioselective gas chromatography/olfactometry.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 93-96 
    ISSN: 0935-6304
    Keywords: Capillary GC ; PTV and on-column injectors ; milk fat triglycerides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The PTV (Programmable Temperature Vaporizer) is a split/splitless injector which allows the sample to be introduced at a relatively low temperature, thus affording accurate and reproducible sampling. After injection the PTV is rapidly heated to transfer the vaporized components into the capillary column. This type of injector has proved to be an efficient tool for the evaluation of fatty acids, essential oils, and pesticides in food analysis. In this work the suitability of PTV for the analysis of milk fat purity by the Official EU method was evaluated. This method is based on the gas chromatographic determination of triglycerides only according to their total number of carbon atoms followed by the application of formulae deriving from multiple linear regressions. The analysis is currently carried out with a packed column or a short capillary column and an on-column injection system. Several samples of pure milk fat and mixtures of milk fat with foreign fat were analyzed with the same capillary column and by using both PTV and on-column injection systems. The results show that the gas chromatographic profile obtained by PTV is comparable with that obtained by the on-column injector, while repeatability and reproducibility data meet the requirements indicated in the Official Method. Therefore, this study demonstrates that it is possible to use the PTV instead of the on-column injector to determine the purity of milk fat with this method.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 217-221 
    ISSN: 0935-6304
    Keywords: HPLC ; UV detection ; linear range ; method validation ; Beer-Lambert law ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Determination of the linear range is one of the main concerns in validation of an HPLC analysis method. It is particularly important since single point calibration will be then used routinely. We proposed an iterative methodology to handle this problem. The idea was, at each step, to test statistically whether the following point belonged to the same regression line. The methodology was then used to evaluate quantitatively the effect on linear range of a shift in detection wavelength or of the detector bandwidth. Although experimental results were globally in accordance with spectroscopic theory, magnitudes observed were rather large. So the linear range could vary by a factor of over 2 with changes in conditions that remained within the range of current practical values. Changes in detection wavelength were limited to about fifteen nm around λmax and the detector used was considered to be representative of modern high-performance UV detectors. The question of how to take consequences in method validation into account was raised. The solution proposed recommended that the validation was undertaken in conditions as close as possible to those where the method would be conducted routinely. This means with the same instrumentation and on the product of interest for analyses.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 231-234 
    ISSN: 0935-6304
    Keywords: Trace analysis ; air samples ; BTX ; equilibrium-sorptive enrichment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 119-122 
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; multi-capillary column ; band broadening ; simulation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 129-130 
    ISSN: 0935-6304
    Keywords: GC-MS ; kava pyrones ; Alpinia zerumbet ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 135-143 
    ISSN: 0935-6304
    Keywords: Chromatographic separation techniques ; High Performance Liquid Chromatography (HPLC) ; Gel Permeation Chromatography (GPC) ; Supercritical Fluid Chromatography (SFC) ; Capillary HPLC ; Nuclear Magnetic Resonance (NMR) spectroscopy ; hyphenation of chromatography with NMR spectroscopy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The hyphenation of chromatographic separation techniques with NMR spectroscopy is one of the most powerful and time-saving methods for the separation and structural elucidation of unknown compounds and molecular compositions of mixtures. Most of the routinely used NMR flow-cells have detection volumes between 40-180 μL for conventional separations with analytical columns, and the newest designs employ detection volumes in the order of 200 nL for capillary separations. The low flow rates used in capillary chromatography permit the use of deuterated solvents. Unequivocal structural assignment of unknown chromatographic peaks is possible by two-dimensional stopped-flow capillary HPLC-NMR experiments.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0935-6304
    Keywords: Conjugated linoleic acid (CLA) ; silver-ion high performance liquid chromatography (Ag+-HPLC) ; cheese ; analysis ; silver-ion chromatography ; tandem-column Ag+-HPLC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A commercial mixture of conjugated linoleic acid (CLA) isomers, reportedly consisting of six components, was recently resolved into 12 peaks attributed to CLA isomers using silver-ion high performance liquid chromatography (Ag+-HPLC). In this study, the coupling of two analytical silver-ion high performance liquid chromatography columns (tandem-column Ag+-HPLC) in series led to the enhanced resolution of CLA isomers. Many CLA isomers were baseline resolved and the pair 18 : 2 8,10 c/t and 18 : 2 7,9 c/t found in cheese products, was resolved for the first time. In this work, a similar commercial CLA mixture was separated into 16 peaks, while CLA isomers from cheese also gave rise to 16 peaks. As expected, the CLA isomers were separated into three geometric groups in the order trans,trans, cis/trans, and cis,cis. Semi-preparative Ag+-HPLC, followed by gas chromatography-mass spectroscopy of the dimethyloxazoline derivatives, was used to confirm the identity of the newly resolved positional CLA isomers. The double bond configuration of CLA isomers was established by gas chromatography-Fourier transform infrared spectroscopy. Two minor t,t CLA isomers found in cheese, presumably 18 : 2 t6t8 and 18 : 2 t13t15, were also separated. The CLA isomeric composition of 16 commercial cheese products was determined.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 159-163 
    ISSN: 0935-6304
    Keywords: Multi-dimensional chromatography ; LC-GC ; AED ; memory effects ; fossil fuel ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Conventional operation of the GC Atomic Emission Detector (AED) system involves backflushing of the microwave induced plasma (MIP) during the elution of small volumes of solvent from the GC column. When performing multi-dimensional, on-line LC-GC-AED, significantly larger solvent volumes are introduced into the system and must subsequently be removed. Thus solvent venting procedures are required and the backflushing of the plasma must be extended to facilitate solvent but not solute removal. This study demonstrates the significance of memory effects imparted upon the MIP of the AED if solvent venting is incomplete. Comparison of conventional GC-AED and multi-dimensional LC-GC-AED is made with respect to a fossil fuel sample.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 171-176 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic chromatography (MEKC) ; solid phase extraction (SPE) ; phenylurea(s) ; herbicide(s) ; monuron ; linuron ; diuron ; isoproturon ; monolinuron ; drinking water ; environmental water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The present paper describes the application of capillary electrophoresis in the micellar mode to the separation and quantitative determination of five phenylurea herbicides, viz. monuron, linuron, diuron, isoproturon, and monolinuron, in water samples. Using uncoated fused silica capillary and phosphate-borate buffer (pH 7.0) containing SDS, the five pesticides are resolved in less than 15 min and quantitatively determined by an ultraviolet detector at 244 nm. Method optimization and validation parameters are presented. Good linearity and repeatability were observed for all the compounds studied (correlation coefficients 0.999). The feasibility of the method developed was tested by simultaneous determination of these herbicides in environmental and drinking water samples at the minimum residue levels (MRLs) (0.1 μg/L) after solid-phase extraction (SPE) preconcentration procedure.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 181-182 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; microwave induced emission spectrometry ; speciation ; mercury ; SPME, headspace SPME ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; interfacing ; sample treatment ; serum ; solid-phase extraction ; sulfonamides ; urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 191-194 
    ISSN: 0935-6304
    Keywords: TLC/FID ; simple and double migration ; triangle of solvent selectivity ; lipochemical media ; fatty acid esters ; esterification ; transesterification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 201-204 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; flame ionization detection ; solvent effects ; aqueous injection ; toluene analysis ; dioxane ; sample preparation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A gas chromatographic method is presented for determining from 1 to 100 μg/mL of 1,4-dioxane in toluene with purities ranging from commercial to high-purity grades. This method relies on extracting 1,4-dioxane from toluene into water. The water extract is analyzed for 1,4-dioxane content by gas chromatography/flame ionization detection and a capillary column coated with a bonded polyethylene glycol stationary phase. Splitless injection is used to achieve a 1 μg/mL detection limit. Purging extracts with nitrogen after an initial analysis is suggested as an extract clean-up procedure and as a means to confirm the identification of 1,4-dioxane. However, for absolute identification of dioxane, gas chromatography/mass spectroscopy should be considered.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 213-216 
    ISSN: 0935-6304
    Keywords: Average velocity ; characteristic parameters ; flow rate ; high pressure drop ; low pressure drop ; outlet velocity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: When the column pressure drop is high, the average velocity of a carrier gas is proportional to the square root of the outlet velocity and the flow rate. Characteristic velocity, flow rate and pressure - the boundary conditions between low and high pressure drop regions - are introduced. Previously derived equations for average velocity vs. outlet velocity were modified to include the flow rate and to become more suitable for the separate studies of the low and high pressure drop regions.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 225-230 
    ISSN: 0935-6304
    Keywords: Green tea ; black tea ; composition ; stability ; capillary electrophoresis ; MEKC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 235-238 
    ISSN: 0935-6304
    Keywords: Cryogenic modulation ; LMCS ; GC×GC ; multidimensional GC ; comprehensive gas chromatography ; petroleum analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 242-244 
    ISSN: 0935-6304
    Keywords: Enantioselective gas chromatography ; 6-O-ethyl-2,3-O-pentyl-β-cyclodextrin ; essential oils ; carboxylic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 247-249 
    ISSN: 0935-6304
    Keywords: High performance liquid chromatography-ultraviolet detection (HPLC-UV) ; Amitraz ; cattle dipping bath ; pesticide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 261-264 
    ISSN: 0935-6304
    Keywords: On-line coupled LC-GC ; normal phase liquid chromatography ; process samples ; oxygenated compounds ; partially concurrent solvent evaporation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Normal phase liquid chromatography-gas chromatography was used with on-column interfacing and partially concurrent solvent evaporation in the analysis of process samples. Samples were taken from reaction mixtures, where the solvent was toluene. The analytes were oxygenated compounds: methyl isobutyrate, methyl methacrylate, methyl α-formyl isobutyrate, and methyl β-formyl isobutyrate. The analytes were transferred from LC to GC using back-flush with a solvent mixture of pentane and diethyl ether. Linearity, repeatability, and transfer efficiency were determined for the method. The method was applied in the determination of the analytes of two different process samples. The results were in good agreement with results obtained by the gas chromatographic method currently in use for the analysis of the process samples.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 265-270 
    ISSN: 0935-6304
    Keywords: Critical micelle concentration ; cationic surfactant ; capillary electrophoresis ; tetradecyltrimethylammonium bromide ; dodecyltrimethylammonium bromide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The determination of the critical micelle concentration (CMC) of cationic surfactants by capillary electrophoresis was demonstrated. In this study, tetradecyltrimethylammonium bromide (TTAB) and dodecyltrimethylammonium bromide (DoTAB) were selected as cationic surfactants and propazine was chosen as test solute. In the evolution of the effective electrophoretic mobility of propazine as a function of surfactant concentration, a dramatic change in slope at a particular concentration is a good indication of the CMC of this surfactant. The CMC values determined experimentally were further confirmed by a curve-fitting approach. Simulation of the electrophoretic mobility curves as a function of surfactant concentration in both micellar electrokinetic chromatography and capillary zone electrophoresis using cationic surfactants as an electrolyte modifier was performed for propazine, and the intersection of these two mobility curves allowed us to precisely predict the CMC of the surfactant. The CMC values determined for TTAB and DoTAB are 1.6 ± 0.1 and 11.0 ± 0.1 mM, respectively, in the case of an electrolytic solution consisting of 70 mM phosphate buffer at pH 6.0. Moreover, the applicability of the electroosmotic mobility as a parameter for the determination of the CMC was examined.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 271-275 
    ISSN: 0935-6304
    Keywords: Supercritical fluid extraction ; enhanced solvent extraction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A supercritical fluid extraction/enhanced solvent extraction system (SFE/ESE) was used to remove polar and non-polar analytes from various matrices. Extraction of environmental pollutants from soil, additives from low density polyethylene, sulfa drugs from animal tissue, and drug from tablet was performed using both SFE and ESE. Results showed that a single instrumental system can be used to perform both ESE with organic solvents and SFE with carbon dioxide-based fluids. Each method has its own unique advantages and applications. The ability to carry out both solvent extraction and supercritical fluid extraction with one system has obvious economical advantages.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 279-282 
    ISSN: 0935-6304
    Keywords: Solid phase microextraction (SPME) ; SPME/HPLC interface ; C-8 refocusing unit ; explosives analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 294-296 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; capillary ; fused silica ; rotenone ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    ISSN: 0935-6304
    Keywords: Deproteinization ; polychlorobiphenyls ; polychlorodibenzo-p-dioxins ; restricted-access reversed-phase packings ; sample preparation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 0935-6304
    Keywords: Mycotoxin ; T2 ; solid phase microextraction ; GC/FID ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 438-442 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; micro-HPLC ; preparation of on-column frits ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Existing methods for preparing frits in packed fused silica capillaries as used for electrochromatography and micro HPLC are not applicable to all silica based packing materials and involve a high thermal stress for both the stationary phase and the fused silica tubing including the polyimide coating. A new procedure for the production of such on-column frits under mild conditions by a sol-gel type reaction of polydimethoxysiloxane (PDMOS) is described in this paper. Reaction conditions were established for optimum mechanical stability and high permeability of the frits. Frits produced in this manner showed no noticeable effect on the overall efficiency.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 443-448 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic capillary chromatography ; temperature programming ; applied voltage programming ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Temperature and voltage programming modes were utilized to optimize selectivity and increase the eluting rate of strongly retained compounds in micellar electrokinetic chromatography. Separations obtained by applying temperature, voltage, and a simultaneous combination of temperature and voltage gradient in micellar electrokinetic capillary chromatography were compared with separations performed under isothermal and constant voltage conditions. A complete separation of all the constituents of the test mixture was only achieved in the temperature programming run and in a combination of temperature and voltage programming modes. Simultaneous variations of column temperature and applied voltage during a separation run, yielded a 30% reduction in the total analysis time when compared to a temperature gradient alone. Temperature programming and voltage programming modes may be the gradient methods of choice because of the considerable technical difficulties involved in performing linear solvent gradient elution in micellar electrokinetic chromatography.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 459-464 
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; gas chromatography ; resistive heating ; organophosphorus pesticides ; PAHs ; triazines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed inside a metal tube which can be heated, and cooled, much more rapidly than any conventional GC oven. The EZ Flash assembly can generate temperature ramps up to 1200°/min and can be cooled down from 300 to 50°C in 30 s. Samples were injected via a conventional split/splitless injector and transferred to the GC column. The combination of a short column (5 m×0.25 mm i. d.), a high gas flow rate (up to 10 mL/min), and fast temperature programmes typically decreased analysis times from 30 min to about 2.5 min. Both the split and splitless injection mode could be used. With n-alkanes as test analytes, the standard deviations of the retention times with respect to the peak width were less than 15% (n = 7). First results on RSDs of peak areas of less than 3% for all but one n-alkane indicate that the technique can also be used for quantification. The combined use of a short GC column and fast temperature gradients does cause some loss of separation efficiency, but the approach is ideally suited for fast screening as illustrated for polycyclic aromatic hydrocarbons, organophosphorus pesticides, and triazine herbicides as test compounds. Total analysis times - which included injection, separation, and equilibration to initial conditions - were typically less than 3 min.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 465-468 
    ISSN: 0935-6304
    Keywords: Amino acid ; stable isotope ; GC-MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---In order to study protein digestibility by means of noninvasive tracer techniques (stable isotopes), a representative oral tracer, i.e. a stable isotope labeled protein, is needed. Therefore, egg white containing L-[ring-2H5]phenylalanine and L-[ring-2H4]tyrosine was prepared. The aim of this study was to measure the isotopic enrichment of the labeled amino acids in the egg white. The use of a standard GC-MS, based on ion trap technology was found to be a reliable technique. The enrichment of L-[ring-2H5]phenylalanine and L-[ring-2H4]tyrosine, expressed in Molar Percent (MP) amounted to 23.2 MP and 2.8 MP respectively.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    ISSN: 0935-6304
    Keywords: Adhesives ; GC/MS ; headspace analysis ; poly(vinyl acetate) ; volatile organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 483-486 
    ISSN: 0935-6304
    Keywords: HPLC ; alumina ; evaporative light-scattering detection ; non-polar lipids ; wax esters ; sterol esters ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---This study describes the performance and capacity of alumina as stationary phase in an HPLC-ELSD (evaporative light-scattering detection) method optimized for the separation of the non-polar lipid classes hydrocarbons, wax esters, sterol esters, triacylglycerols, and sterols, including quantitative determination of these lipid classes in natural samples. By using gradient elution and constant equilibration times between injections, highly reproducible separations of triacontane, stearyl oleate, and cholesterol oleate were accomplished with a binary mobile phase system. Phase A contained 0.5% tetrahydrofuran in hexane and phase B 20% isopropanol and 20% tetrahydrofuran in hexane. The same system was also used to determine the non-polar lipid classes in a zooplankton sample, the major lipid class being wax esters, followed by triacylglycerols, sterol esters, sterols, and hydrocarbons. Substantial amounts of an unknown compound, possibly acylated glyceryl ethers, were also found. The equilibration time of alumina was relatively slow compared to a polyvinyl alcohol stationary phase used earlier by the authors and calibration curves for different lipid classes were more uniform and linear with alumina.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 495-500 
    ISSN: 0935-6304
    Keywords: CZE ; mobility ratio ; migration time prediction ; mathematical model ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The electrophoretic mobility ratio (R value) of any two ions is constant and independent of the capillary type and electrophoretic conditions if their electrical charges and hydration radii are constant. The use of strong acid salts and quaternary ammonium salts is therefore proposed for the determination of R values. Such analytes are called markers. The following determinations can be carried out: (i) the determination of the migration time corresponding to the electroosmotic flow (EOF) in any capillary under any electrophoretic condition by measuring the migration times of two markers in the condition studied (useful when the EOF is weak); (ii) the determination of the migration time of an analyte in any capillary by knowing the migration time of the markers in the capillary studied. If the pH is changed and the ionization of the analyte is pH dependent, the resulting migration time for the analyte can be calculated. The constancy of the mobility ratios of seven markers was checked experimentally at eight different pH values (between pH 3 and 10), at three temperatures, and for two buffer concentrations. The predicted and experimental migration times were also compared in two different types of capillaries.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 509-513 
    ISSN: 0935-6304
    Keywords: Fast GC ; fast temperature programming ; resistive heating techniques ; short columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---One possible way to speed up a gas chromatographic analysis is the application of fast temperature programming by using resistive heating techniques. With this heating technique programming rates up to 20° per second can be reached. A relative standard deviation of retention times better than 0.2% is obtained. Using fast temperature programming the analysis-times of a mineral oil sample, an industrial oligomer sample, and toxic compounds in diesel fuel have been reduced 5 to 20 times, compared to a standard temperature programmed analysis. In most cases resistive heating cannot be applied to reduce the analysis time of a complex sample. The use of fast temperature programming is preferable to the use of short columns and columns operated at above-optimum carrier gas velocities.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 521-526 
    ISSN: 0935-6304
    Keywords: Multichannel silicone trap ; water analysis ; flow rate ; methanol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The application of Multichannel Silicone Rubber Traps for the direct analysis of organic compounds in water was studied. The optimum collection flow rate for a 10 mL sample was found to be ca. 150 μL·min-1. The effect of methanol on the retention power of the trap was evaluated. The addition of a methanol fraction of up to 40% to the water standards did not show any loss in collection efficiency. It was shown that the extraction of organic compounds from water with the multichannel trap is uncomplicated, i. e. methanol is not required to achieve accurate analyses, concentration of the sample onto the trap is by gravity flow, and excess water remaining in the multichannel trap after water extraction is removed by centrifugation. With the use of the multichannel silicone rubber trap a wide boiling point range of compounds were analyzed from aqueous samples at levels of 1-4 μg·L-1.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 533-540 
    ISSN: 0935-6304
    Keywords: Chlorobiphenyl congeners ; Aroclor 1254 ; DB-XLB phase ; GC-MS-SIM ; PCB 126 ; toxic equivalency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Complete PCB congener distributions in a panel of Aroclor mixtures were previously obtained by combining data from several HRGC systems. In that study quantitation of minor components may have been unreliable due to single level calibration against high levels of individual congener standards. Two lots of Aroclor 1254 had markedly different congener distributions. In this study, the design and performance of a congener-specific PCB analysis method employing GC-MS-SIM detection of congeners separated on a DB-XLB capillary column are discussed. Quantitation is carried out against a 6-level inclusive standard curve of a mixture of 144 congeners found in Aroclors. A separate procedure to measure trace levels of PCB 126 in Aroclors using the same system, combined with levels initially acquired for other congeners, facilitates estimation of TEQ values (Toxic Equivalencies of the PCB mixtures to 2,3,7,8-TCDD). PCB congener profiles of 15 Aroclor 1254 mixtures are presented. These profiles show that the less common, high TEQ variety of Aroclor 1254 was manufactured by an atypical, two-stage chlorination process that was apparently used during the final 1% of Aroclor 1254 production (ca. 1974-1976).
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 547-552 
    ISSN: 0935-6304
    Keywords: Water analysis ; polar pollutants ; solid-phase extraction ; chemically-modified polymeric resins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---This study assesses how the physical characteristics of styrene-divinylbenzene (PS-DVB) resins affect the extent to which they are modified when they are functionalized, and how they affect recoveries in on-line solid-phase extraction (SPE) of some polar phenolic compounds, pesticides, and metabolites from water samples which were analyzed by liquid chromatography and UV detection. For this purpose, three commercial PS-DVB resins with different physical characteristics (Amberchrom GC-161m and two different PLRP-S resins) were chemically modified by placing a hydrophilic group, an o-carboxybenzoyl moiety, on their surface; although the physical characteristics are different, the extent of modification did not vary significantly. The results from the SPE process with each sorbent were related to their physical and chemical properties. The polymers with higher surface area provided better recoveries. Moreover, the recoveries for these analytes were better with the chemically-modified polymers due to the higher polarity of these sorbents. The best recovery values were with the sorbent obtained from the chemical modification of Amberchrom GC-161m, the commercial sorbent with higher surface area. For instance, in the analysis of 50 mL of a sample of 2 μg L-1, the recovery of phenol was 40% with Amberchrom GC-161m and 65% with the chemically-modified Amberchrom GC-161m.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 421-423 
    ISSN: 0935-6304
    Keywords: Enantioselective gas chromatography ; 2,3-di-O-methyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin ; 2,3-di-O-acetyl-6-O-tert-butyldimethylsilyl-β-cyclodextrin ; γ-dithiolactones ; olfactometry ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    ISSN: 0935-6304
    Keywords: HPLC ; nitrotyrosine ; nitrotocopherol ; analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---For three decades, high performance liquid chromatography has proven itself to be a powerful, flexible, and inexpensive tool for basic and clinical research. Recent advances in our understanding of disease have prompted a demand for more sensitive and selective methods of routine bioanalysis, particularly with respect to the determination of oxidative metabolites and biomarkers of oxidative stress. Multidimensional detectors utilizing coulometric arrays offer a solution to these research needs. The challenge to the bioanalyst is now to creatively apply HPLC-ECD technology to promising research and clinical enterprises.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 449-453 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; experimental design ; cyclodextrin ; chiral separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Orthogonal design and uniform design were used for the optimization of separation of enantiomers using 2,6-di-O-methyl-β-cyclodextrin (DM-β-CD) as a chiral selector by capillary zone electrophoresis. The concentration of DM-β-CD, buffer pH, running voltage, and capillary temperature were selected as variable parameters, their different effects on peak resolution were studied by the design methods. It was concluded that orthogonal design offers a rapid and efficient means for testing the importance of individual parameters and for determining the optimum operating conditions. However, for a large number of both factors and levels, uniform design is more efficient. The effect of addition of methanol and citric acid buffer on the separation of enantiomers was also examined.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 454-458 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; reversed phase ; prototypical substances ; retention parameter model ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A set of four prototypical substances (naphthalene, acetanilide, phenol, and benzonitrile) is selected from 26 different analytes used by Seibert and Poole for characterization of the retention behavior of 20 liquid chromatographic systems of a C18 reversed phase with methanol/water and acetonitrile/water as mobile phases. Retention data of 22 different analytes can be calculated from the retention data of the set of prototypical substances with a mean standard deviation of 5.4%. Two phase system maps similar to that suggested by Poole et al. are provided for an octadecylsiloxane-bonded silica sorbent with methanol and acetonitrile as cosolvents with water.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 475-476 
    ISSN: 0935-6304
    Keywords: Organic peroxides ; gas chromatography ; FID ; cold on-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 469-474 
    ISSN: 0935-6304
    Keywords: Supercritical fluid extraction ; SFE modifiers ; pseudoephedrine ; suphedrine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The effect of modifier and additive composition upon pseudoephedrine recovery from spiked-sand and Suphedrine tablets was examined. Recovery was shown to be dependent on CO2 density as well as on the addition of an ion pairing agent to the matrix. The presence of methanol in the extraction vessel prior to SFE was shown to play a significant role in the ion-pair extraction process. Recovery was also shown to be a function of ion-pairing reagent composition and concentration. The most successful recovery was obtained in the presence of 1-heptanesulfonic acid (HSA), sodium salt in methanol at a 5:1 molar ratio (reagent to drug). The increased extractability in the presence of ion-pairing reagent was attributed to reduced analyte polarity and analyte-matrix displacement. Alternatively, a matrix-spiked mixture of methanol and 1% water by itself was just as effective as a matrix-spiked mixture of methanol and HSA for attaining efficient extraction. Several in-cell (e. g. to the matrix) and in-line (e. g. to the fluid) modifiers were examined for the extraction of pseudoephedrine from Suphedrine tablets. The greatest pseudoephedrine recovery from Suphedrine tablets of 82% (7.0%) was achieved with 10% (l% H2O) methanol-modified CO2 in the presence of 400 μL of methanol (l% H2O). Finally AgCl tests and infrared analyses were performed on two tablet extracts. It was confirmed that even in the absence of any in-cell modifier, a small fraction of pseudoephedrine hydrochloride could be extracted.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 487-489 
    ISSN: 0935-6304
    Keywords: Carboxymethyl derivatives of amines ; dodecyl-L-hydroxyproline ; chelate ring ; chemiluminescence ; ruthenium complex ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Carboxymethyl derivatives of amines containing a chiral α-carbon were separated into enantiomers by high-performance liquid chromatography using octadecylsilanized silica gel coated with N-n-dodecyl-L-hydroxyproline as the stationary phase and an aqueous solution containing copper(II) as the mobile phase. Detection was by post-column reaction involving derivatization to tertiary amine and chemiluminescence reaction of ruthenium bipyridine complex.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 0935-6304
    Keywords: Large volume injection ; packed capillary LC ; temperature programming ; retinyl esters ; vitamin A ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A non-aqueous isocratic reversed-phase packed capillary high performance liquid chromatography method for the determination of retinyl esters, utilizing temperature programming and on-column focusing large volume injection, has been developed. The stationary phase material was C30, and the mobile phase consisted of acetonitrile-dichloromethane (70 : 30, v/v). A three-step temperature program, starting at 10°C for 10 min, then 1°/min to 30°C, and finally 2.5°/min to 70°C, was found most appropriate. Compared to an isothermal separation at 25°C, this temperature program provided improved peak resolution, enhanced peak shapes of the last eluting compounds, and a reduction of the overall elution time. A mass limit of detection of 27 pg was found with respect to retinyl palmitate, using UV detection with an “U” shaped flow cell at 327 nm. This corresponds to a concentration limit of detection of 2.7 pg/μL, when utilizing an injection volume of 10 μL. The concentration of retinyl palmitate in arctic seal liver samples was estimated to be 62.6 μg/g liver.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 0935-6304
    Keywords: A,C- and A,D-bridged calix[6]arene ; stationary phase ; capillary gas chromatography ; geometric and positional isomer separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A,C-Bridged (ACCX) and A,D-bridged isopropyldimethylsilylcalix[6]arene (ADCX) dissolved in OV-1701 were used as stationary phases in isothermal capillary gas chromatographic separation of some positional isomers. Retention factors and separation factors for the isomers were measured. The isomers investigated are well resolved on the two phases. Retention of all the solutes investigated is longer on ACCX than on ADCX. The longer retention on A,C-bridged calix[6]arene is probably due to extra inductive interactions of the solute molecule with the carbonyl moieties in the phase. Separation factors for closely eluting isomer pairs are similar on the two phases. This seems to indicate that the carbonyl moieties do not play an appreciable role in discriminating the isomer molecules on entering the cavity of the calixarene if the solute is retained by the inclusion process.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 647-665 
    ISSN: 0935-6304
    Keywords: Two-dimensional GC ; statistical method of overlap ; petroleum ; fuels ; enviromental samples ; organochlorine compounds ; flavors ; aromas ; foods ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The writer of this review published in 1978 a three-part article on two-dimensional gas chromatography in the first three issues of this journal [1]. The review was written at a time when capillary column GC was still in its infancy. Commercial columns were (essentially) unavailable and sample introduction into capillary columns was done exclusively in the split mode. Two-dimensional separations were explored in only a few laboratories. The limitations of capillary column technology made this exercise rather difficult. The introduction of fused silica capillary columns in the early eighties drastically changed the landscape in which gas chromatography was practiced. It took the chromatographic community just a few years to convert from packed columns to capillary columns. Instrumentation and accessories specifically designed for capillary column use came onto the market. This writer had great hopes that the revolution in capillary column GC would be mirrored in the development of instrumentation for Two-Dimensional Gas Chromatography. This never materialized. On the contrary, tentative steps taken by a few manufacturers and suppliers of chromatographic equipment fizzled out. It was perhaps the introduction of relatively inexpensive and user friendly GC/MS instrumentation, in combination with nearly indestructible fused silica capillary columns that took away the incentive to develop commercially viable Two-Dimensional Gas Chromatography. Much of the thinking went like this: why insist on good chromatography if mass spectrometry can do the job without the need for complete separation. Some progress in the further development of conventional Two-Dimensional Gas Chromatography has certainly been made over the last 20 years but there has not been a great deal of excitement. Applications have also been relatively sparse and they are limited to just a few areas. Science does not remain static and chromatography is no exception. Progress in gas chromatography is driven by new technology and ideas. Substantial improvements in two-dimensional GC were not forthcoming until Phillips and his research group introduced and implemented an entirely new form of Two-Dimensional Gas Chromatography, called comprehensive two-dimensional GC, or GC×GC. This breakthrough occurred only in 1991 [2]. It does take some time before scientists change attitudes and habits. There is always a time lag between the introduction of new technology and its general acceptance. The public's attitude toward comprehensive Two-Dimensional Gas Chromatography is probably no exception. The number of scientists who are actively pursuing this new branch of gas chromatography is still very small. It is often a single individual who carries the torch. J.B. Phillips' name is synonymous with comprehensive Two-Dimensional Gas Chromatography. He is not only its inventor and proponent but his fertile mind has initiated research in other related areas. Sadly, he passed away shortly before this review was written. This contribution is dedicated to his memory.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 0935-6304
    Keywords: Coupled GPC-GC ; gel permeation chromatography ; on-column interface ; co-solvent trapping ; gas chromatography ; large volume injection ; organophosphorus pesticides ; olive oil ; automation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The robustness of an automated on-line GPC-GC-FPD method for the determination of Organophosphorus (OP) Pesticides in olive oil has been significantly improved, now allowing a routine operation. The original GPC-GC transfer technique employed a loop type interface with an early vapor exit and co-solvent trapping. Shooting, caused by boiling delay and malfunctioning of the solvent vapor exit during the transfer of the 3 mL solvent fraction to the retention gap, resulted in insufficient focusing of the OP-pesticides. In this interfacing concept, the GPC fraction is introduced directly into the carrier gas stream during a certain time interval using the Dualchrom pressure- and flow regulation, resulting in a very stable transfer. The interface now basically corresponds to an on-column interface with flow regulation. Via a Pyrex glass door behind the GC-oven door it can be seen that the liquid flow is broken up into alternating gas-liquid segments by the carrier gas flow during transfer. This avoids shooting in the retention gap and broadens the temperature range for successful transfer. By using a smaller sized GPC column the solvent fraction transferred was reduced to 1.3 mL. Methyl acetate/cyclopentane and the co-solvent n-nonane were selected for their lower boiling points. The modified method is very robust and has been applied to the analysis of 28 different OP-pesticides in olive oil with an overall detection limit of 0.002 mg/kg. Routinely 24 h of unattended operation is possible with a cycle time of 75 min.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 29-32 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; electroosmotic flow ; frit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The formation of bubbles in capillary electrochromatography (CEC) is well documented: possible origins include Joule heating and variations in EOF velocity on passing from the stationary phase through the frit and into the open tube. Methods for the prevention of bubble formation are discussed which are confirmed by experimental results. Using frit lengths varying from 1 mm to 6 mm it is shown how frit length is directly related to the likelihood of bubble formation and how this is affected by applied voltage. It is shown that the change in applied voltage across a capillary affects the formation of bubbles and also that rebonding octadecylsilane (ODS) onto the silica frit after formation of the frit can minimize the formation of bubbles and how this effects the chromatography. A method is also described for increasing the robustness of silica capillaries using a column coupler along with modifications made to conventional capillary electrophoresis equipment to cater for CEC.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; CE ; chemical migration ; food contact plastics ; dihydroxybenzenes ; packaging ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A capillary electrophoresis method has been developed to determine 1,2-dihydroxybenzene and 1,3-dihydroxybenzene in the food simulants distilled water, 3% acetic acid, 15% ethanol, and olive oil. Both substances, used as monomers and additives to make food packaging plastics, could be analyzed within 15 min. The 1,4-dihydroxybenzene isomer was unretained and eluted with the electroosmotic flow, and so the CE method can give only a semi-quantitative estimate of this isomer if it is present as a migrant. The analytical recovery for the 1,2- and 1,3-isomers from spiked simulants was good at 87% to 98% except for 1,2-dihydroxybenzene which could only be recovered to the extent of 58% from olive oil. Calibration graphs were linear and the limit of detection for each substance was 0.6 mg/kg, which is well below migration limits for these substances. It is concluded that CE offers a rapid and reliable analysis for the control of migration from plastics intended for food contact which employ 1,2-dihydroxybenzene or 1,3-dihydroxybenzene during manufacture, and offers a screening method for 1,4-dihydroxybenzene migration.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 0935-6304
    Keywords: Programmed temperature vaporization (PTV) ; GC-AED ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Programmed temperature vaporization injection (PTV) coupled to gas chromatography and atomic emission detector (AED) has been studied for large volume injection of gaseous samples. As examples of the effectiveness of the technique, the results of the analysis of a series of headspace samples of foods such as garlic and onion, and of landfill gases are presented. The volumes of gaseous samples reconcentrated varied from a few milliliters up to liters depending on analyte dilution, through focusing onto a sorbent trap, then rapid liberation into the GC-AED system by programmed thermal desorption. Despite the high carrier gas flow rates associated with direct PTV-GC, AED performance and sensitivity were unaffected. The detailed elemental information obtained from the PTV-GC-AED analyses was confirmed using a PTV coupled to a gas chromatograph with ion trap detector mass spectrometer as detector (PTV-GC-ITD/MS).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 55-58 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic capillary chromatography ; sample dissolving solvent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    ISSN: 0935-6304
    Keywords: Sulfobutyl ether-β-cyclodextrin ; micellar electrokinetic chromatography ; separation of regioisomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 0935-6304
    Keywords: HPLC ; di(2-ethylhexyl) phthalate ; migration ; foods and food simulants ; PVC cling film ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 79-82 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; thickeners ; monosaccharides ; PMMA capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Gelling agents based on polysaccharides have become extremely important in the food industry. As more and more products like soups and sauces have become available in lyophilized form, thickeners have to be added to give a controlled consistency to the finished meal. A capillary electrophoretic method has been developed to investigate the monosaccharide composition of hydrolyzed thickeners. 2-Aminoanthracene was used as a derivatization reagent to allow sensitive fluorescence detection. This system was applied to a set of standard thickeners as well as to food samples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 83-88 
    ISSN: 0935-6304
    Keywords: Large volume injection ; programmed-temperature vaporizer ; organic acids ; phenols ; derivatization ; trimethylsulfonium hydroxide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The combination of on-line methylation using trimethylsulfonium hydroxide with large volume injection of 100 μL was evaluated for the analysis of organic acids and phenols in water. Solvent split injection was applied with complete evaporation of the solvent before analytes were transferred onto the GC column. Despite complete solvent removal, losses were very low compared to conventional splitless injection even for volatile acidic compounds such as propionic acid and phenol. This is explained by intermediate formation of low volatility trimethylsulfonium salts of the analytes which were held in the injector for long evaporation times of up to 10 min, if the evaporation temperature was as low as 10°C. Using a simple liquid/liquid extraction procedure, volatile fatty acids, dicarboxylic acids, benzoic acids and phenols could be detected in 5 mL of water at concentrations of 0.04-0.1 μmol/L with GC/MS in full scan mode. Lactic, pyruvic, and also malonic acids could only be detected at higher levels because of their limited extractability from water as well as their poorer methylation yields. The method provides an easy way to sensitively detect acidic compounds of medium to high volatility in water. It was applied for screening of organic acids and phenols in batch cultures of anaerobic bacteria of which one example is shown.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 0935-6304
    Keywords: Capillary GC ; milk fat purity ; chemometrics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The adulteration of milk fat with foreign fat has been and still is a major concern in the dairy industry. Milk fat purity is currently evaluated by triglyceride analysis by using the Official EU method. The detection limit of the various vegetable and animal fats ranges between 4 and 6%. This research was carried out to verify whether it is possible to decrease the detection limits of beef tallow, which is the most widely used adulterating animal fat. For this purpose, determinations of diglycerides and 3,5-cholestadiene, together with the Official EU method, were applied both to several samples of pure milk fat and to mixtures of milk fat with different percentages of beef tallow. The best results were obtained combining the data deriving from the three determinations by multivariate statistical techniques; in particular, the statistical model obtained by the UNEQ technique seems to be able to decrease the detection limit of beef tallow from 5.2 to 2%. The diglyceride and 3,5-cholestadiene evaluation, combined with the Official EU method for triglycerides, can be usefully applied both to detect small additions of beef tallow and to demonstrate the adulteration of milk fat samples showing results close to the detection limit of the official method.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 109-115 
    ISSN: 0935-6304
    Keywords: Solid-phase microextraction ; capillary gas chromatography ; volatile polar compounds ; water matrix ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A method was developed for the analysis of volatile polar compounds in a water matrix using open cap vials Solid Phase Micro-Extraction (SPME) and Capillary Gas Chromatography (CGC). Both SPME techniques - direct sampling and headspace - were tested. Optimization of experimental conditions - exposure time, desorption time, with headspace SPME in addition the influence of the temperature and ionic strength of the sample solution on compound sorption, and finally GC response - were investigated. The analytes were extracted by directly immersing the 85 μm polyacrylate fiber in the aqueous sample or in the headspace. The linear range of the preconcentration process and the precision were examined. The amount of polar analytes sorbed on the fiber was determined and was found to be concentration dependent; it amounted to 0.014-0.64% in the concentration range of 0.00425-425 ppm studied in aqueous solution for direct sampling SPME and to 0.011-2.76% for solutions of concentration 0.0425-255 ppm for headspace SPME. The limits of determination were ascertained. Headspace SPME was applied to the analysis of real-life samples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 126-128 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic chromatography ; capillary electrophoresis ; amines ; cyclodextrins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 123-125 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography (GC) ; atomic emission detection (AED) ; human plasma ; drug monitoring ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    ISSN: 0935-6304
    Keywords: RP-HPLC ; theophylline ; asthma ; apnea ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 153-158 
    ISSN: 0935-6304
    Keywords: Vapor analysis ; nerve agents ; sulfur mustard ; data acquisition ; automation ; valve injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A method is presented for the continuous analysis of generated vapors of the nerve agents soman and sarin and the blistering agent sulfur mustard. By using a gas sampling valve and a very short (15 cm) column connected to an on-column injector with a “standard length” column, the system can either be calibrated or used for performing high speed gas analyses. When using a flame ionization detector, the detection limit was ca. 100 ppb (ca. 0.5-1.0 mg/m3). This technique is applied in inhalation toxicokinetic studies of nerve agents and mustard gas in the guinea pig.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 149-152 
    ISSN: 0935-6304
    Keywords: Large volume on-column injection ; flooded zone ; capacity of 0.53 mm i. d. precolumns ; solvent trapping ; solvent vapor exit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---0.53 mm i. d. uncoated precolumns of about 10 m in length followed by a solvent vapor exit have become a standard set-up for large volume on-column injection. It went unnoticed, however, that the introduction of a vapor exit requires two modification of previous working guidelines. First, the capacity of the precolumn to retain sample liquid is increased by a factor of 2.3-3 as a result of the around 100 times higher carrier gas flow rate. Secondly, it must be considered that this gain in retention of liquid is lost again upon closure of the exit: as the gas flow rate is reduced to a few mL/min, the layer of the residual sample liquid expands about 2.3-3 times. Hence, closure should occur late, and a section of the precolumn must be assigned for this secondary spreading.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 63-66 
    ISSN: 0935-6304
    Keywords: Divinylbenzene copolymers ; exclusion limit ; size exclusion chromatography ; surface area ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 164-170 
    ISSN: 0935-6304
    Keywords: Food packaging ; functional barrier ; gas chromatography ; laminated paperboard ; mass spectrometry ; single sided headspace ; paperboard ; plastic film ; polymer film ; test cell ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A new cell for single sided headspace sampling has been developed for the analysis of volatile organic compounds from food packaging paperboard and laminated paperboard. The cell, which samples the volatile organic compounds over a selected surface, is useful for determining the barrier function of laminated paperboards with respect to volatile compounds. The analysis of volatile organic compounds is carried out by purge and trap capillary gas chromatography in combination with mass spectrometric detection and compound identification. The new sampling cell was constructed to facilitate specific analysis of organic compounds from only one side of a laminated paperboard. The construction and the operating principles of the new sampling device are described. The repeatability of the single sided headspace procedure was found to be quite good. Relative standard deviations of about 5-7% were obtained for the major compounds quantified in replicate headspace analyses of a laminated paperboard. The volatile compounds released from the inner side of a food packaging paperboard sample with different surface composition on the two sides were determined. The barrier function against volatile organic compounds of some laminated paperboards was investigated employing the new headspace cell.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 188-190 
    ISSN: 0935-6304
    Keywords: LC stationary phases ; porous graphitic carbon ; surfactant ; alkyl glycosides ; glycosides ; evaporative light scattering detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...