Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (9,049)
  • 1985-1989  (7,419)
  • 1980-1984  (4,493)
  • 1925-1929  (808)
  • 1915-1919  (682)
  • 1880-1889  (50)
  • Cell & Developmental Biology  (20,280)
  • pharmacokinetics  (1,600)
  • Magnetic resonance imaging
  • Nuclear reactions
Material
Years
Year
Keywords
  • 1
    ISSN: 1530-0358
    Keywords: Rectal cancer ; Preoperative staging ; Endoluminal ultrasound ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: The aim of this study was to compare the value of endoluminal ultrasonography (ELUS) with magnetic resonance imaging (MRI) for preoperative staging of rectal carcinoma. METHODS: Thirty-seven consecutive patients were examined by ELUS and MRI. Imaging results were compared with pathohistologic studies. A tumor extending beyond the bowel wall was considered to be “positive” and one within the bowel wall was considered “negative.” Lymph node involvement was considered present if nodes equal to or greater than 5 mm in diameter were found in the perirectal tissue. For evaluating the differences between the two methods, the Mc Nemar test was performed. RESULTS: T-Staging was correct in 88.2 percent (30/34) of patients by ELUS and in 82.3 percent (28/34) by MRI (difference not significant). N-Staging was correct in 80 percent (20/25) by ELUS and in 60 percent (15/25) by MRI (difference of borderline significance). A comprehensive preoperative staging (T + N) was made correctly in 68 percent (17/25) by ELUS and in 48 percent only (12/25) by MRI (difference not significant). CONCLUSIONS: We suggest that ELUS and MRI must be evaluated within the framework of established parameters when treatment modalities such as preoperative radiation therapy and local or radical surgical approach must be decided.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1530-0358
    Keywords: Anterior rectocele ; Defecography ; Magnetic resonance imaging ; Clinical assessment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: The aim of this study was to devise a measuring method for an anterior rectocele on standardized defecographies and magnetic resonance images (MRI) to quantify anterior rectocele and to test whether this could substantiate clinical decision making for operative treatment for anterior rectocele. METHODS: Quantitative analysis by the measuring method as proposed was compared with qualitative scores on defecographies and MRI from the same patients. Thirty-eight patients with symptoms compatible with an anterior rectocele were subjected to physical examination in the left decubitis position and supine position and to defecography. Findings on defecography were compared with findings on physical examination. Thirteen patients were examined before and after surgical correction of the anterior rectocele for a total of 51 qualitative and quantitative examinations. The group of operated patients was analyzed for treatment results. Nineteen controls were included. RESULTS: Sixtysix radiographs of 33 defecographies were qualified in three grading classes and quantified with the proposed method by two observers. The mean measured value of the anterior rectocele in the three subjective grading classes is significantly different (P 〈 0.001). Anterior rectoceles qualified as severe had a measured value of 20 mm or more in 96 percent of the radiographs. Lower gradings were never 〉20 mm. On MRI severe anterior rectoceles were not scored and measured values did not correlate with qualitative scores. When findings on physical examination were compared with defecographic measurement, the coefficient of correlation (r)between the radiologic assessment and clinical examination in the left decubitis position is r = 0.87, for the examination in the supine position,r = 0.77. All 15 cases scored as severe anterior rectocele in the left decubitis position had a measured anterior rectocele of ≥20 mm. In the 13 cases that received surgery, there was a significant reduction of the anterior rectocele (P 〈 0.001) and clinical improvement. Patients with small or moderate anterior rectocele on physical examination with a size ≥20 mm on defecography were cured by surgical correction. None of the controls had an anterior rectocele on physical examination or an anterior rectocele ≥20 mm on defecography. CONCLUSIONS: An anterior rectocele with a size of 20 mm or more corresponds with a qualitative score of “severe” on Radiographic defecography. Physical examination for anterior rectocele in the left decubitis position corresponds best with quantitative Radiographic assessment and anterior rectocele with a size ≥20 mm on defecography is pathologic. Patients with complaints compatible with anterior rectocele can be assessed in objective and quantitative terms by radiography and can be successfully surgically treated, even if at physical examination the anterior rectocele is not classified as large, provided that dynamic defecography shows an anterior rectocele of ≥20 mm. The potential of dynamic MRI with regard to anterior rectoceles presently seems absent.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1530-0358
    Keywords: Magnetic resonance imaging ; Fistula-in-ano
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: Successful management of anal fistulas depends upon accurate assessment of the primary tract and any secondary extensions. Preoperative imaging has, to date, been disappointing. METHODS: A prospective study of 35 patients with a clinical diagnosis of fistula-in-ano was performed comparing magnetic resonance imaging with the independently documented operative findings. Magnetic resonance imaging was also compared with anal endosonography in 20 patients. RESULTS: Magnetic resonance imaging is accurate and demonstrates pathology missed at surgery by experienced coloproctologists. Magnetic resonance imaging is superior to anal endosonography. CONCLUSIONS: Magnetic resonance imaging is advocated as the method of choice when imaging is required for anal fistulas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 37 (1994), S. 777-781 
    ISSN: 1530-0358
    Keywords: Anal ultrasound ; Magnetic resonance imaging ; Internal anal sphincter ; External anal sphincter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: A recent application of endosonography in the evaluation of anal sphincter morphology has led to controversy about the possibility of precisely assessing the diameter of external and internal anal sphincter muscles. On the other hand, magnetic resonance imaging (MRI) has been proposed to allow a more detailed view of the anatomy of the pelvic floor. However, both techniques have not yet been compared directly. METHODS: Eight healthy volunteers (age range, 25–40 years; 5∶3, male∶female) participated. Anal ultrasound was performed using a 7.5-MHz rectal transducer which produced a transversal panorama display of 360, allowing an image perpendicular to the anal canal. Imaging of the diameter of the internal and external anal sphincter muscles was performed with the transducer placed in the midanal canal, and measurement was always performed by the same investigator in dorsal projection. MRI was performed using a 1.5 Tesla Magnetom (Siemens, Erlangen, Germany) to obtain sagittal and angled axial (perpendicular to the anal canal) planes for consecutive 3-mm slices which were evaluated by four independent raters. RESULTS: Muscle thickness of the sphincter muscles in dorsal projection was 1.96±0.61 mm for the internal sphincter and 6.35±1.07 mm for the external sphincter using ultrasound. It was 1.72±0.13 mm and 3.99±0.99 mm, respectively, using MRI. When both measures were compared, only the internal sphincter data correlated significantly (r=0.818,P=0.0023) between both measures. Sagittal resonance imaging of the anal canal did not allow for differentiation of both muscles at all. Differentiation among mucosa, submucosa, and internal anal sphincter is not possible with MRI but may well be performed with high-resolution ultrasound. CONCLUSION: Anal ultrasound carries the potential of becoming a routine clinical procedure for evaluation of the anal anatomy and morphology in defecation disorders, but current MRI assessment of the anal anatomy is elaborate, costly, and does not provide any further insights.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 16 (1994), S. 183-192 
    ISSN: 1279-8517
    Keywords: Magnetic resonance imaging ; Knee ; Anatomy ; Cadaver ; Correlative studies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Pour guider ou valider une interprétation d'examens IRM, on a souvent recours au cadavre. On obtient une corrélation directe par confrontation de la coupe IRM d'une pièce avec la coupe anatomique faite dans le même plan. Une autre méthode plus facile et plus usuelle dite de corrélation indirecte est celle où une coupe IRM prise sur le vif est comparée avec des coupes sur le cadavre sans rapport direct. Elle ne présente pas les difficultés techniques d'une corrélation directe, qui requiert d'une part la préservation de forme et de la composition des tissus, et d'autre part l'exactitude du plan de coupe sur le cadavre qui doit coïncider avec la coupe IRM. Une règle IRM-compatible, conçue pour réaliser cette corrélation directe, a permis l'étude de 10 genoux de sujets embaumés, avec des séquences différentes d'IRM, à plusieurs reprises. En dépit des variations, la corrélation s'avère satisfaisante. Sur 54 coupes IRM soumises à cette corrélation, la corrélation est bonne ou parfaite pour 47 d'entre elles selon des observateurs differents, soit pour 87% des coupes. Cette méthode nouvelle, souple et simple, permet de tirer le meilleur usage du matériel humain conservé, avec un champ d'applications potentielles large. Nous sommes en train de la développer davantage pour l'évaluation des capacités techniques de nouvelles séquences d'image.
    Notes: Summary Cadaveric material is often used to guide and validate the interpretation of magnetic resonance imaging (MRI) studies. Direct correlation is achieved when the cadaver material is imaged and then directly sectioned in the plane of the image. Indirect correlation, where the cadaveric sections are compared with unrelated in-vivo images, is easier and more commonly used. Technical difficulties associated with the direct method include preservation of form and composition of the tissues, and the choice of the correct location and plane in which to section the cadaver. Using an MRI compatible ruler, designed to assist the direct correlation of MRI and cadaveric sections, we have examined 10 preserved (embalmed) cadaveric knees using different MRI sequences on several occasions. Despite these variations, subsequent sectioning of the cadaveric knees has shown good correlation with the MR images. Of 54 MR images compared with cadaveric sections, anatomical correlation was rated by independent observers as good or perfect in 47 (87%). This new, versatile and simple method can make better use of our preserved human cadaveric material and has potentially wide application; we are now developing it further to assess the technical capabilities of novel imaging sequences.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 16 (1994), S. 429-438 
    ISSN: 1279-8517
    Keywords: Articular cartilage ; Magnetic resonance imaging ; Cartilage thickness ; Patella ; Knee joint
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé L'évaluation quantitative de l'épaisseur et du volume du cartilage de patellas humaines, fixées dans un mélange d'alcool et de formol, a été réalisée en imagerie par résonance magnétique (IRM) car on ne sait encore avec exactitude si l'aspect morphologique du cartilage normal ou lésé peut être parfaitement démontré par cette technique. L'IRM a été réalisée sur un appareil 1.0 T (épaisseur de coupe : 2 mm, résolution : 0,39–0,58 mm) avec les séquences suivantes : 1) séquence en spin écho pondéré T1, 2) 3D-MRAGE, 3) 3D-FISP, 4) 3D-MTC-FISP, 5) 3D-DESS, 6) 3D-FLASH. Après la réalisation de l'IRM, la patella était sectionnée tous les 2 mm, perpendiculairement à sa surface articulaire, à l'aide d'une scie à ruban. Le volume de son cartilage était déterminé sur les coupes anatomiques et les images IRM grâce à un système d'analyse d'images Vidas IPS 10 (Kontron). Les mesures étaient réalisées avec et sans la couche en hyposignal correspondant à la zone transitionnelle située entre le cartilage articulaire et l'os sous-chondral. Lorsque cette couche en hyposignal était prise en compte, le volume était surestimé par l'IRM de 16 à 19%. Lorsque cette couche en hyposignal n'était pas prise en compte, les volumes étaient inférieurs à ceux déterminés par les coupes anatomiques : T1-SE : −18,2%, MPRAGE : −22,6%, FISP : − 17,1%, MTC-FISP : − 9,5%, DESS : − 9,3% et FLASH : −6,1%. La séquence FLASH permettait l'appréciation la plus correcte et la plus reproductible de la morphologie du cartilage. La différence persistante par rapport au volume réel du cartilage peut être due au fait que la zone calcifiée du cartilage n'est pas délimitée par l'IRM.
    Notes: Summary Quantitative assessment of cartilage volume and thickness in a formalin-alcohol fixed specimen of a human patella was conducted with magnetic resonance imaging (MRI), as it is still unclear whether the morphology of normal and damaged cartilage can be accurately demonstrated with this technique. MR imaging was carried out at 1.0 T (section thickness 2 mm, in-plane-resolution 0.39 – 0.58 mm) with the following pulse sequences: 1) T1-weighted spin-echo, 2) 3D-MPRA-GE, 3) 3D-FISP, 4) 3D-MTC-FISP, 5) 3D-DESS, 6) 3D-FLASH. Following imaging, the patella was sectioned perpendicular to the articular surface at intervals of 2 mm with a diamond band-saw. The volume of its cartilage was determined from the anatomical sections and the MR images, using a Vidas IPS 10 image analysing system (Kontron). Measurements were carried out with and without the low-signal layer in the transitional zone between the articular cartilage and the subchondral bone. If the low-signal layer was included, the volume was overestimated with MRI by 16 to 19 %. Without the low-signal layer the volumes were less than those determined from the anatomical sections: T1-SE −18,2 %, MPRAGE −22.6 %, FISP −17.1 %, MTC-FISP −9.5 %, DESS −9,3% and FLASH −6.1 %. The coefficient of variation for a 6-fold determination of the volume amounted to between 6.2 % (T1-SE) and 2.6 % (FLASH). The FLASH sequence allowed the most valid and reproducible assessment of the cartilage morphology. The remaining difference from the real volume of the cartilage may be due to the fact that the calcified zone of the cartilage is not delineated by MRI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1437-2320
    Keywords: Magnetic resonance imaging ; normal pressure hydrocephalus ; schwannoma ; spinal accessory nerve
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Schwannomas of the spinal accessory nerve are rare lesions. They can be characterized by their locations as either intrajugular or intracisternal schwannomas, most of them being intrajugular. Only five cases arising in the cisterna magna are reported in literature. Clinical symptoms generally consist of 11th cranial nerve palsy associated with cerebellar signs and myelopathy. An additional case, studied by MRI, is described. The patient showed a mild cerebellar syndrome and normal pressure hydrocephalus symptoms. He was operated on and the mass completely removed with good postoperative results. The role of MRI for diagnosis of lower cranial nerve schwannomas is stressed, even though does not detect the exact nerve of origin. Total removal of these lesions is recommended, since their benign nature and unavoidable recurrence in case of partial excision.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric surgery international 9 (1994), S. 441-443 
    ISSN: 1437-9813
    Keywords: Lymphangioma ; Scrotum ; Ultrasound ; Magnetic resonance imaging ; Pediatric
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Lymphangiomas are unusual benign neoplasms originating from the lymphatic system that are rarely found in the scrotal area. Ultrasound and magnetic resonance findings in a 4-year-old boy with a scrotal lymphangioma are presented. There was no recurrence after surgical excision.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 23 (1994), S. 455-457 
    ISSN: 1432-2161
    Keywords: Bone marrow ; Blood supply ; Magnetic resonance imaging ; Enhancement ; Lumbar spine ; Gadopentetate dimeglumine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A retrospective study was performed to determine whether bone blood supply can be assessed on gadolinium-enhanced magnetic resonance imaging. Lumbar spine magnetic resonance imaging (MRI) examinations of 49 patients attending for post-laminectomy examination were reviewed (30 male, 19 female, mean age 46.4 years, age range 23–84 years). Each study included sagittal T1-weighted spin echo sequences before and after gadolinium administration. Regions of interest were drawn within the L3 vertebral body from a parasagittal slice from each sequence. Signal intensity (SI) values were ascertained and the percentage increase in SI was calculated. For each patient, changes in receiver gain for pre and post-gadolinium images were corrected by an image scaling factor. In all cases, a measurable increase in SI was found (mean 15.3%, range 4.4–55.7) due to bone vascularity. The results give no indication of the quantity or timing of blood supply but provide a basis for further work.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 23 (1994), S. 327-332 
    ISSN: 1432-2161
    Keywords: Soft tissue tumors ; Magnetic resonance imaging ; Wrist
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We reviewed 20 cases of soft tissue masses of the hand and wrist, and compared the impressions from the original magnetic resonance (MR) imaging reports with the preoperative clinical impression and postoperative pathological diagnoses. The most commonly occurring masses were ganglia, lipomas, and giant cell tumors of tendon sheaths. MR imaging suggested the correct diagnosis in 16 of the 20 cases, whereas the clinical impression was correct in 10 instances. Confident preoperative diagnosis may be made with MR imaging due to the characteristic appearances of many benign soft tissue tumors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 23 (1994), S. 337-341 
    ISSN: 1432-2161
    Keywords: Infantile Fibrosarcoma ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Two cases of infantile fibrosarcoma are described. This rare childhood malignancy of mesodermal origin usually affects the lower limbs, as it did in both of our cases. Previously, the only treatment option available involved some form of radical and often mutilating surgery. More recently, combination chemotherapy has given good results, with the effect that various imaging modalities have become important in assessing both the initial extent of disease and the response to treatment. Computed tomography has the advantage of demonstrating the amount of osseous involvement, but at the expense of a considerable dose of ionizing radiation. On the other hand, magnetic resonance imaging, with its multiplanar capacity, gives superior demonstration of breaching of tissue planes, which has important implications for planning of surgery. However, as in other soft tissue tumours, changes in signal characteristics with treatment have proved less specific than was originally anticipated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1432-2161
    Keywords: Malignant fibrous histiocytoma ; Magnetic resonance imaging ; Soft tissue tumors ; Pathology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We reviewed the magnetic resonance (MR) appearances of 13 malignant fibrous histiocytomas (MFH) of soft tissue and correlated each with the respective lesion's histopathology. The MR images were evaluated for signal intensity on T1- and T2-weighted spin echo sequences, homogeneity of the lesion, presence of internal low signal septations, and margin definition. Histologic subtypes of MFH included storiform-pleomorphic, giant cell, myxoid, and inflammatory. We could not establish a correlation between MR appearance and histopathology. Instead, our series exhibited general features suggestive of malignant soft tissue neoplasms, namely poor margin definition, internal low signal septation, and heterogeneous high signal intensity on T2-weighted images.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1432-2161
    Keywords: Distal radioulnar joint ; Radioulnar ligaments ; Magnetic resonance imaging ; Ulnar wrist pain ; Wrist injury
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previously developed criteria of normal distal radioulnar joint (DRUJ) axial geometry were applied to routine magnetic resonance (MR) images of 50 wrists. All wrists lacked clinically evident DRUJ instability. An attempt to apply the three geometric criteria to seven of the cases was not possible, since the prescribed landmarks were not visible. The remaining 43 cases were retrospectively divided into a symptomatic group (25 wrists), with clinical abnormalities referable to the ulnar side of the wrist, and an asymptomatic group (18 wrists), with no such abnormalities. Abnormal DRUJ geometry was found in 12 symptomatic and 2 asymptomatic wrists. This difference between the groups is significant (p=0.02), suggesting that many symptomatic wrists exhibit different DRUJ geometry than is found in most asymptomatic wrists.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1432-2161
    Keywords: Osteoarthritis ; Magnetic resonance imaging ; Histopathology ; Radiography ; Marrow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Subchondral signal abnormalities are often present on magnetic resonance (MR) images of patients with osteoarthritis, but no study correlating these changes with histopathology has been published. We selected nine consecutive patients with clinical and radiographic diagnosis of moderate to severe osteoarthritis of the knee scheduled to undergo joint replacement surgery, and performed MR imaging and conventional radiographs preoperatively. After surgery, the resected portions of the femur and tibia underwent gross and microscopic examination, and the findings were correlated with the corresponding findings on the imaging studies. Subchondral MR signal abnormalities of the femur or tibia were present in seven of the nine patients, with intermediate signal on T1-weighted images and low or isointense signal on T2-weighted images. The subchondral signal abnormalities were hemispherical in configuration and corresponded predominantly to fibrous tissue replacing the fatty marrow. A component of trabecular thickening was also present.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Virchows Archiv 424 (1994), S. 113-119 
    ISSN: 1432-2307
    Keywords: Lethal osteochondrodysplasia ; Dwarfism ; Acrodysplasia ; Magnetic resonance imaging ; Molecular biology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A hydropic stillborn female fetus of 22 weeks' gestation with shortlimbed skeletal dysplasia and brachyphalangy is described. The markedly shortened phalanges of both hands had a most unusual angel-like configuration radiologically. Histological examination and comparison with a normal hand of the same gestational age revealed this appearance to be due to disturbed enchondral ossification with premature calcification of epiphyseal cartilage and thickening and outfolding of diaphyseal bone as wing-shaped appositions. Magnetic resonance imaging of the fetus demonstrated marked hyperplasia of cartilage, most impressive in the pelvis. This new type of lethal bone dysplasia may be placed in the group of metatropic dysplasias and similar disorders.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Urological research 22 (1994), S. 209-212 
    ISSN: 1434-0879
    Keywords: Extracorporeal shockwave lithotripsy ; Magnetic resonance imaging ; Stone hardness
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Accurate prediction of the response of an individual patient to lithotripsy remains impossible. Certain factors such as the chemical composition, size, and position of the calculus are known to be important in determining the success rate. This paper reports the use of magnetic resonance imaging (MRI) to evaluate 141 urinary calculi in vitro. A wide range of signals for each chemical type of calculus was found on each of the three imaging sequences used (T1-weighted, T2-weighted, and proton density). None of the chemical groups examined showed a typical MRI profile allowing it to be distinguished from the other groups. Analysis of variance showed a statistical difference between signals for apatite and struvite on the T1-weighted sequence, and between struvite and uric acid on the proton density sequence (both, P〈0.05). These results show for the first time that MRI is capable of distinguishing between different chemical types of stones. This is particularly important for the comparison of struvite and apatite which appear to be similar in conventional investigations but have quite different hardness values. Further work is in progress correlating the results of this study with stone microhardness and extracorporeal shockwave lithotripsy fragility tests to determine whether MRI accurately predicts the success of lithotripsy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1432-0533
    Keywords: Krabbe disease ; Globoidcellleukodystrophy ; Magnetic resonance imaging ; Neuropathology ; paramagnetic effect
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previous imaging studies in infants with globoid cell leukodystrophy (GLD) using computed tomography have demonstrated a reduction in cerebral white matter and increased density symmetrically in the regions of the thalami, periventricular white matter, and the internal capsules. Correlation of these findings with morphologic studies at necropsy has not been made. In particular, deposition of calcium has not been described. We have evaluated two children with GLD confirmed by the absence of leukocyte galactosylceramide β-galactosidase activity using repeated magnetic resonance (MR) scans in each and correlated the imaging results with post-mortem analyses in one. Neuropathologic examination revealed abnormalities typical for GLD. In addition to the absence of normal myelination throughout cerebral and cerebellar white matter, MR images demonstrated the presence of a paramagnetic effect in the regions of the thalami, corona radiata, and centra semiovale. We have observed in histologic preparations from these areas a dense accumulation of globoid cells and some calcium, which we suggest may be responsible for producing the paramagnetic effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1432-0428
    Keywords: Diabetes mellitus ; pharmacokinetics ; insulin absorption ; metabolic control ; skin temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Subcutaneous insulin absorption kinetics were assessed in 50 healthy study subjects (21 female, 29 male; age 26±3 years, BMI 22.5±1.8 kg/m2; mean±SD) during 45 min after periumbilical injection of soluble human U40- or U100-insulin (0.15 IU/kg). Subcutaneous fat thickness was measured by ultrasound, and skin temperature at the injection site was registered. Serum insulin concentrations increased within 30 min from basal values of 37±15 to 140±46 pmol/l after U40-insulin and from 36±10 to 116±37 pmol/l after U100-insulin (p〈0.001). After 45 min serum insulin concentrations were 164±43 pmol/l with U40-insulin and 128±35 pmol/l with U100-insulin (p〈0.001). Decline in blood glucose levels and suppression of C-peptide were comparable. The serum insulin levels reached 30 and 45 min after U40- and U100-insulin injection were positively correlated with skin temperature (p〈0.0008), and negatively correlated with subcutaneous fat thickness (p〈0.009). In conclusion, the lower insulin concentration of U40-insulin, higher skin temperature, and a thinner subcutaneous fat tissue at the injection site are associated with accelerated and enhanced subcutaneous insulin absorption.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1432-0428
    Keywords: Glibenclamide ; glyburide ; sulphonylurea ; compounds ; AG-EE 623 ZW ; dose-response ; time-action profiles ; pharmacokinetics ; glucose clamp technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Insulin and glucose responses to glibenclamide were studied in comparison to a novel non-sulphonylurea drug (AG) by means of the euglycaemic clamp technique. Nine fasting male subjects were connected to a Biostator and 1.75, 3.5 or 7.0 mg glibenclamide or 1.0, 2.0 or 4.0 mg AG were given and blood glucose concentrations were clamped at 10% below basal values. Glucose infusion rates were registered over 10 h after administration of the tablet. Maximal glucose infusion rates after glibenclamide were 40% higher compared to AG (1.75 vs 1.0 mg, 3.5 vs 2.0 mg, 7.0 vs 4.0 mg, respectively) and were reached after 3–3.5 h for all doses. After glibenclamide, area under the glucose infusion curves and maximal incremental serum insulin responses were higher by 25–40% and by 30% compared to AG when low, medium and high doses of each drug were tested. However, a linear dose relationship was obtained for both drugs when the glucose infusion rate was plotted against the area under the insulin curve. In fact, both drugs were equipotent on a molecular weight basis. The hypoglycaemic index of both drugs (integrated glucose infusion rate divided by integrated insulin release) expressed per μmol of drug revealed a dose-dependent and parallel inverse curvilinear relation to increasing doses. This methodological approach allowed us to quantify and compare the metabolic effects of oral hypoglycaemic agents under standardised experimental conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 16 (1994), S. 303-305 
    ISSN: 1279-8517
    Keywords: Myology ; Three-dimensional reconstruction ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Lors d'un examen radiologique de routine (TDM, IRM) pratiqué chez une femme de 72 ans, une image tissulaire molle fut mise en évidence dans le triangle cervical postérieur gauche. La reconstruction tridimensionnelle de cette structure a suggéré qu'il pouvait s'agir d'une variante musculaire, en l'occurrence d'un muscle élévateur de la clavicule. Dans notre cas, l'origine musculaire était située au niveau de la colonne cervicale supérieure et son insertion distale sur le tiers latéral de la clavicule. Cette exemple nous amène à rappeler l'aspect général des variantes anatomiques musculaires dans le contexte des techniques d'imagerie moderne.
    Notes: Summary During routine radiological examination of a 72 year-old woman a soft-tissue shadow in the left posterior triangle of the neck was observed. Three-dimensional reconstruction of this structure suggested that it might be a muscular variant: a levator claviculae muscle. In our case it took origin from the upper part of the cervical column and was inserted into the lateral third of the clavicle. With this example as a background, the general significance of anatomical muscular variants for modern imaging techniques is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 150-152 
    ISSN: 1432-0509
    Keywords: Intrahepatic foregut cysts ; Magnetic resonance imaging ; Contrast-enhanced MRI ; Computed tomography ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Hepatic foregut cysts are uncommon lesions of the liver. In this report we prospectively examined two patients by means of computed tomography (CT), ultrasound, and contrast-enhanced magnetic resonance imaging. Ciliated hepatic foregut cysts were subsequently demonstrated in both patients following CT-guided biopsy. Magnetic resonance imaging was found to be useful in differentiating these cysts from other lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 347-348 
    ISSN: 1432-0509
    Keywords: Mesenteric cyst, milk of calcium ; Ultrasound ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A mesenteric cyst with milk of calcium in an adult patient is presented. Preoperative evaluation included plain film, ultrasound, computed tomography (CT), and magnetic resonance imaging (MRI). To our knowledge, the presence of milk of calcium in a mesenteric cyst has not been previously described.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 1432-0509
    Keywords: Hepatocellular carcinoma ; Tumor thrombus ; Inferior vena cava ; Right atrium ; Brain metastasis ; Computed tomography ; Magnetic resonance imaging ; Angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Tumor thrombus (TT) in the inferior vena cava (IVC) and right atrium (RA) is rarely encountered. We have diagnosed before death and treated a case of hepatocellular carcinoma (HCC) with TT in the IVC and RA, accompanied by a brain metastasis. The image characteristics on computed tomography (CT), magnetic resonance imaging (MRI), and conventional angiography are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 67-69 
    ISSN: 1432-0509
    Keywords: Leiomyoma ; Kidney ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Renal leiomyoma are rare, benign tumors of the kidney. There is little information about the imaging of these tumors with modern modalities. We present a case of computed tomographic (CT) and magnetic resonance (MR) imaging of a large renal leiomyoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 180-181 
    ISSN: 1432-0509
    Keywords: Prostate, MR ; Prostate, neoplasm ; Magnetic resonance imaging ; Cystosarcoma phyllodes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cystosarcoma phyllodes of the prostate is a rare, relatively benign sarcoma of the prostate. We describe the magnetic resonance imaging findings in an unusual case of cystosarcoma phyllodes which resulted in extensive local recurrence and sarcomatous degeneration. Although uncommon, radiologists should be aware of the existence of cystosarcoma phyllodes of the prostate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 19 (1994), S. 61-63 
    ISSN: 1432-0509
    Keywords: Choledochal cyst ; Magnetic resonance imaging ; Pregnancy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Choledochal cyst presenting during pregnancy is a rare condition, associated with potentially life-threatening complications for both the mother and developing fetus. Clinical symptoms are nonspecific, and radiographic evaluation is complicated by the presence of the gravid uterus. The authors describe a 34-year-old pregnant female presenting in the third trimester with obstructive jaundice and a right upper quadrant mass. Multiplanar and multisequence imaging with MR established the antepartum diagnosis of choledochal cyst, avoiding the use of ionizing radiation during pregnancy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1432-0509
    Keywords: Liver ; Visceral larva migrans ; Toxocariasis ; Diagnosis ; Ultrasound ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Visceral larva migrans is a syndrome characteristically involving children with a history of pica, and usually presents with fever, abdominal pain, tender hepatomegaly, and hypereosinophilia. Hepatic granulomas of visceral larva migrans are rare in adults. We describe three adult patients with hepatic lesions which on histopathology demonstrated characteristic granulomas of visceral larva migrans. All patients had abdominal sonograms and two had additional MR scans of the liver. Both ultrasound and magnetic resonance imaging demonstrated characteristic appearances which have not been described previously (viz., ill-defined central necrotic areas surrounded by concentric thick walls and perifocal edema in the liver parenchyma).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 1432-086X
    Keywords: Liver ; interventional procedure ; Liver neoplasms, therapy ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Purpose The aim of this study was to evaluate the effectiveness of transcatheter arterial embolization (TAE) followed by percutaneous ethanol injection (PEI) in the treatment of large hepatocellular carcinoma (HCC) lesions. Methods Fifteen patients with HCC were treated by means of TAE followed by 6–16 ethanol injections. In 10 patients, the HCC was solitary (3–8 cm); 3 patients had 1, and 2 patients had 2 daughter nodules (3 cm or smaller) in addition. In 12 of 15 main tumors and in 4 of 7 daughter nodules, a tumor capsule was observed by computed tomography or magnetic resonance imaging. Results Combined treatment with TAE and PEI resulted in complete necrosis of 12 of 15 main tumors and 7 of 7 daughter nodules on biopsy. Treatment failure (incomplete necrosis) occurred in 3 unencapsulated main tumors. The 1-year survival rate in 10 patients was 100%. Conclusion The combination of TAE and PEI proved to be an effective treatment for large HCC, including those with 1–2 small daughter nodules. The presence of a tumor capsule significantly correlates (p 〈 0.05) with a favorable outcome of treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 20 (1994), S. 365-367 
    ISSN: 1432-1238
    Keywords: Netilmicin ; Once daily dosing ; Neonatal/pediatric intensive medicine ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To examine a once daily dosing regimen of netilmicin in critically ill neonates and children. Design and setting Open, prospective study on 81 antibiotic courses in 77 critically ill neonates and children, hospitalized in a multidisciplinary pediatric/neonatal intensive care unit. For combined empiric therapy (aminoglycoside and beta-lactam), netilmicin was given intravenously over 5 min once every 24 h. The dose ranged from 3.5–6 mg/kg, mainly depending upon gestational and postnatal age. Peak levels were determined by immunoassay 30 min after the second dose and trough levels 1 h before the third and fifth dose or after adaptation of dosing. Results All peak levels (n=28) were clearly above 12 μmol/l (mean 22, range 13–41 μmol/l). Eighty-nine trough levels were within desired limits (〈4 μmol/l) and 11 (11%) above 4 μmol/l, mostly in conjunction with impaired renal function. Conclusions Optimal peak and trough levels of netilmicin can be achieved by once daily dosing, adapted to gestational/postnatal age and renal function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 1432-1106
    Keywords: Radiography ; Magnetic resonance imaging ; Microlesion ; Single-Unit ; Monkey
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A technique is described for in vivo localization of microelectrodes during single-unit recording in the alert monkey. Four hollow glass spheres filled with copper sulfate and iohexol were affixed to the surface of the animal's skull prior to the acquisition of a series of coronal magnetic resonance (MR) images. These reference beads were visible in both X-ray and MR images. Cranial recording chambers were then implanted bilaterally over the amygdaloid complex. A microelectrode was advanced to various depths in the subject's brain. At each selected microelectrode site, five radiographs were obtained and a small electrolytic lesion was made. Based on the data from the radiographs, we computed the position of the microelectrode tip at each site relative to the reference beads. With a precision of 625 μm, this method was used to predict the neuroanatomical location of ten microlesions placed in both subcortical and cortical structures. Postmortem histological analysis revealed that the actual location of the lesions closely matched predictions arrived at using the X-ray/MRI localization technique. This technique thus provides an accurate, reliable and noninvasive method for in vivo localization of microelectrode recording sites.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    ISSN: 1432-1084
    Keywords: Brain oedema ; Dehydration ; Magnetic resonance imaging ; Middle cerebral artery occlusion ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Mannitol and furosemide treatment of ischaemic brain oedema caused by middle cerebral artery occlusion (MCAO) was studied by MRI in 87 rats. MRI was performed in all rats before and 30–360 min after drug infusion. The examinations were performed in the presence of an intact blood-brain barrier (BBB) 6 h after MCAO, and 3 days after MCAO at the time of maximal disruption of the BBB. Spin echo (SE) sequences were used for imaging and for determination of the relaxation times T1 and T2. Subtraction images were constructed. Furosemide dehydrated healthy and ischaemic brain. Mannitol had no dehydrating effect on healthy brain tissue. However, when the BBB was disrupted in severe oedema mannitol produced a decrease in water content, a shortening of T1 and T2, and a decrease in intracranial pressure (ICP), while in less severe oedema mannitol could increase brain water content, thus aggravating ICP. The subtraction technique allowed visualisation of the transient change in bulk in water animals with disruption of the BBB after mannitol treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 4 (1994), S. 175-178 
    ISSN: 1432-1084
    Keywords: Actinomycosis ; Computed tomography ; Heart diseases ; Magnetic resonance imaging ; Mediastinal diseases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Widespread use of antibiotics facilitates the development of some uncommon chronic infections such as actinomycosis. The clinical and radiographic findings overlap those of other inflammatory and neoplastic conditions. With a review of the literature, we report the CT and MRI findings in a case of thoracic actinomycosis, presenting with right ventricular failure caused by heart involvement. CT was helpful in identifying the mediastinal extent of the disease and in demonstrating the absence of pulmonary involvement. MRI, however, offered complementary information, especially in assessing heart involvement without the need for intravenous contrast media. On T2-weighted images the mediastinal process was noted to be of relatively low signal intensity, possibly indicating its benign nature. The association with heart involvement was suggestive of thoracic actinomycosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 4 (1994), S. 265-267 
    ISSN: 1432-1084
    Keywords: Liver ; Extramedullary plasmocytoma ; Ultrasound ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The case of a 72-year-old man with a solitary hepatic extramedullary plasmocytoma (EMP) is presented. Preoperative MRI and CT findings showed a homogeneous solitary unspecific lesion with an early brief enhancement after IV contrast administration. Differential diagnoses are reviewed and discussed. Imaging findings were not specific but could be observed in a hypervascular hepatic metastasis. However associated with IgG monoclonal spike, without bone marrow involvement, EMP should be suspected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1432-1084
    Keywords: Liver neoplasm ; Magnetic resonance imaging ; Tissue characterisation ; Turbo spin echo sequences
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To determine whether turbo spin echo (TSE) sequences can replace conventional T2-weighted spin echo (SE) sequences in MRI of the liver, 40 patients with focal liver lesions were imaged at 0.5 T. A T2-weighted SE sequences (TR/TE 1800/90 ms, number of signals averaged [NEX]=2, scan time=7:16 min), a TSE sequence (TR/TE 1800/90 ms, NEX=4, number of echos per excitation=13, echo spacing=12.9 ms, scan time=4:16 min) and a T1-weighted SE sequence (TR/TE 350/15 ms, NEX=2, scan time=4:21 min) were obtained and image quality, lesion detectability and lesion differentiation were evaluated qualitatively by subjective assessment using scores and quantitatively by lesion-liver contrast-to-noise (CNR) and tumour/liver signal intensity (SI) ratios. The image quality of the TSE sequence was substantially better compared with the T2-weighted SE sequence due to a reduction in motion artefacts and better delineation of anatomical details. Of a total of 158 visible lesions the T1-weighted SE, TSE, and T2-weighted SE sequences showed 91%, 81% and 65% of the lesions, respectively. Thus the TSE sequence depicted 24% (P〈 0.001) more lesions than the T2-weighted SE sequence. In all types of pathology the lesion-liver CNR of the TSE sequence was significantly (P〈 0.001) higher compared to the CNR of the T2-weighted SE sequence (+ 55–65%), indicating superior lesion conspicuity. Lesion characterization was equally good on the two T2-weighted sequences with no difference in the tumour/liver SI ratio. Using a criterion of tumour/liver SI ratio equal to or higher than 2, haemangiomas larger than 1 cm in diameter could be differentiated from other lesions with a sensitivity and specificity of 95% and 96%, respectively. Our results indicate that the TSE sequence is suitable for replacing the conventional T2-weighted SE sequence in MRI of focal liver lesions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    ISSN: 1432-1920
    Keywords: Pituitary adenoma ; Craniopharyngioma ; Rathke cleft cyst ; Magnetic resonance imaging ; Gadolinium DTPA ; Normal pituitary gland
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We compared the position of the normal pituitary gland as estimated by gadolinium (Gd)-DTPA-enhanced MRI, with its position at surgery in 40 patients with intra- and juxtasellar tumours: 22 pituitary adenomas, 4 craniopharyngiomas, 7 meningiomas, 2 germinomas, and 5 Rathke cleft cysts. In 37 of these, the normal gland showed more intense contrast enhancement than the adjacent tumour, from which it could be differentiated by Gd-DTPA-enhanced MRI, especially in the sagittal plane. The direction of displacement of the normal pituitary gland correlated well with tumour type, so that its position proved helpful in the differential diagnosis. The normal gland was typically displaced superiorly by pituitary adenomas, inferiorly by craniopharyngiomas, and anteriorly by germinomas. It showed variable displacement by Rathke cleft cysts, and was not usually displaced by meningiomas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 426-429 
    ISSN: 1432-1920
    Keywords: Basilar artery thrombosis ; Stroke ; Infarct ; Magnetic resonance imaging ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to review the imaging features in acute (〈24 h) basilar artery thrombosis. CT and MR studies in 11 patients with clinical diagnosis of acute basilar artery thrombosis were retrospectively reviewed. MR angiography was obtained in 4 patients. Correlation with clinical symptoms was performed. Multiple cranial nerve palsies and hemiparesis were the most common clincal symptoms at presentation. CT revealed hyperdense basilar arteries (n=7) and hypodensities in the posterior circulation territory (n=8). In one instance, the infarction was hemorrhagic. MR imaging showed absence of flow void within the basilar in 6 patients and MRA (using both PC and TOF techniques) confirmed absence of blood flow in 4 basilar arteries. One week after presentation, 5 patients died. Autopsy was obtained in 1 case and confirmed the diagnosis of basilar artery thrombosis. Basilar artery thrombosis has fairly typical imaging features by both CT and MR. MRA may be used to confirm the diagnosis. Prompt recognition may lead to early thrombolytic treatment and may improve survival.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Rat spinal cord ; Experimental spinal cord injury ; Gadolinium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We assessed the capacity of MRI to show and characterise the spinal cord (SC) in vivo in normal and chronically injured adult rats. In the chronically injured animals the SC was studied by MRI and histological examination. MRI was performed at 1.5 T, using gradient-echo and spin-echo (SE) sequences, the latter with and without gadolinium-DTPA (Gd-DTPA). Several positions were tried for good alignment and to diminish interference by respiratory movements. Images of the SC were obtained in sagittal, coronal, and axial planes. Normal SC was observed as a continuous intensity in both sequences, although contrast resolution was better using SE; it was not possible to differentiate the grey and white matter. Low signal was seen in the damaged area in chronically injured rats, which corresponded to cysts, trabeculae, mononuclear infiltrate, and fibroglial wall on histological examination. Gd-DTPA failed to enhance the SC in normal or chronically injured rats. It did, however, cause enhancement of the lesion after acute SC injury.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 649-651 
    ISSN: 1432-1920
    Keywords: Brain, growth and development ; Magnetic resonance imaging ; children
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We examined 66 healthy volunteers aged 4 to 50 years by magnetic resonance imaging (MRI) and the signal intensity was measured on T2-weighted images in numerous sites and correlated with age and sex. Using distilled water and cerebrospinal fluid (CSF) as references on each slice, we calculated the signal intensities of the brain structures. Calculated ratios between structures did not change with age, except for those of the globus pallidus and thalamus, in which the signal intensities decreased more rapidly. The signal intensities of other brain structures changed equally but this could not be discerned visually and quantitative measurements were required. The signal intensities in the white and deep grey matter decreased rapidly in the first decade and then gradually to reach a plateau after the age of 18 years. Maturation of the brain thus seems to continue until near the end of the second decade of life. No sex differences were found. Quantitative analysis requires intensity references. The CSF in the tips of the frontal horns seems to be as reliable as an external fluid reference for intensity, and can be used in routine examinations provided the frontal horns are large enough to avoid partial volume effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 644-648 
    ISSN: 1432-1920
    Keywords: Brain, growth and development ; Magnetic resonance imaging ; Children ; High signal foci
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The magnetic resonance images of 67 healthy subjects aged 4–50 years were studied for differences in general signal intensity between the different brain structures, the frequency of focal intensity changes in the brain, and variations in size of the cerebrospinal fluid (CSF) spaces. In adults over 25 years of age the thalamus gave lower signal than the putamen or caudate nucleus. Definite periventricular high signal was found in the white matter of one third of subjects of all ages. Small (〈5 mm in diameter) high signal foci were found in the cerebral white matter on T2-weighted images in 27% of subjects (20% of healthy children and adolescents and 34% of adults). They gave high signal on both short and long echoes in 11% of children and adolescents and in 22% of adults; 51% of all foci gave high signal with both echoes. This does not support the hypothesis that they are caused mainly by enlarged Virchow-Robin spaces. Of the high signal foci on T2-weighted images, 86% were in watershead areas. Two foci were found in one subject in the periventricular watershed area (beside the tips of the frontal horns) and they were never seen in the other deep white matter regions. In healthy, relatively young subjects with no known risk factors, high signal foci other than Virchow-Robin spaces, were common; neither their prevalence nor their number correlated with age in this series. A few slightly large sulci were found in some adults.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 652-655 
    ISSN: 1432-1920
    Keywords: Brain ; Magnetic resonance imaging ; Acute lymphoblastic leukaemia ; Radiotherapy ; Meningioma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We carried out MRI on 43 survivors of childhood cancer after different treatment protocols with or without cranial radiotherapy. They were free of disease, therapy having been discontinued 2–20 years earlier. Treatment had been for various malignancies, excluding brain tumours; 27 had received cranial irradiation for acute lymphoblastic leukaemia (ALL) or lymphoma. Two asymptomatic young women treated for ALL had falx meningiomas. White matter changes, low intensity foci (representing calcification or old haemorrhage) and heterogeneous intensity focic old haemorrhages) were seen only in patients who had undergone radiotherapy. Because of the possibility of benign, potentially curable brain tumours occurring after cranial irradiation, it may be wise to carry out occasional cranial imaging in the follow-up of these patients. No routine imaging follow-up is needed after chemotherapy alone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 1432-1920
    Keywords: Cerebral ischaemia ; Magnetic resonance imaging ; Contrast media ; Superparamagnetic iron oxide ; Stroke model ; Cerebral blood flow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract An imaging technique capable of detecting ischaemic cerebral injury at an early stage could improve diagnosis in acute or transient cerebral ischaemia. We compared the ability of superparamagnetically contrastenhanced MRI and conventional T2-weighted MRI to detect ischaemic injury early after unilateral occlusion of the middle cerebral artery in 12 male Wistar rats. Permanent vessel occlusion was achieved by a transvascular approach, which has the advantage of not requiring a craniectomy. At 45–60 min after the procedure, the animals had conventional T2-weighted MRI before and after administration of a superparamagnetic contrast agent (iron oxide particles). Unenhanced images were normal in all animals. After administration of iron oxide particles, the presumed ischaemic area was clearly visible, as relatively increased signal, in all animals; this high signal area corresponded to the area of ischaemic brain infarction seen on histological studies. Magnetic susceptibility effects of iron particles cause low signal in normally perfused cerebral tissue, whereas tissue with reduced or absent blood flow continues to give relatively high signal. Our results suggest that superparamagnetic iron particles may significantly reduce the interval between an ischaemic insult and the appearance of parenchymal changes on MRI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 35-36 
    ISSN: 1432-1920
    Keywords: Craniopharyngioma ; Salmonella typhi ; Abscess ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract ASalmonella typhi abscess within a craniopharyngioma in a 28-year-old woman is reported. CT and MRI demonstration of cerebral edema adjacent to the tumor suggested an atypical presentation of craniopharyngioma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1432-1920
    Keywords: Spinal infection ; Abscess ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We reviewed serial MRI with and without gadolinium-DTPA in eight patients with spinal epidural abscess and correlated the findings and the clinical manifestations. In four patients, diffuse abscesses spanned four vertebral bodies or more; the others had focal abscesses associated with osteomyelitis and/or diskitis. In three of the four patients with diffuse abscesses, MRI (NCMRI) showed diffuse encasement of the subarachnoid space. Contrast-enhanced MRI (CEMRI) demonstrated linear enhancement surrounding unenhanced pus. In the four patients with focal abscesses, CEMR delineated the inflammatory process more clearly than NCMR. On follow-up studies, decrease in abscess size and better visualization of the subarachnoid space correlated with clinical improvement in both diffuse and focal abscesses. Despite clinical improvement, contrast enhancement persisted in the disk or epidural space of three patients, and was thought to represent chronic granulomatous change or postsurgical scar. CEMR is very valvable for the initial diagnosis of an epidural abscess, particularly if it involves lengthy segments. During follow-up, CEMR can document responses to therapy, and provide information for determining appropriate treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 63-64 
    ISSN: 1432-1920
    Keywords: Acoustic neuroma ; Magnetic resonance imaging ; Temporal bone tumours
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Meniéres discase. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 93-96 
    ISSN: 1432-1920
    Keywords: Tuberculosis ; Central nervous system ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The MRI findings of 18 proven cases of central nervous system (CNS) tuberculosis were reviewed; 10 patients were seropositive for HIV. All had medical, laboratory, or surgical proof of CNS tuberculosis. Eleven patients had meningitis, of whom two also had arachnoiditis. Five patients had focal intra-axial tuberculomas: four brain masses and one an intramedullary spinal lesion. Two patients had focal extra-axial tuberculomas: one in the pontine cistern, and one in the spine. In all 11 patients with meningitis MRI showed diffuse, thick, meningeal enhancement. All intraparenchymal tuberculomas showed low signal intensity on T2-weighted images and ring or nodular enhancement. The extra-axial tuberculomas had areas isointense or hypoitense relative to normal brain and spinal cord on T2-weighted images. Although tuberculous meningitis cannot be differentiated from other meningitides on the basis of MR findings, intraparenchymal tuberculomas show characteristic T2 shortening, not found in most other space-occupying lesions. In the appropriate clinical setting, tuberculoma should be considered.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 111-114 
    ISSN: 1432-1920
    Keywords: Pituitary tumour ; Haemorrhage ; Magnetic resonance imaging ; Bromocriptine medication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a group of 69 patients with pituitary tumours, 12 were found to have evidence of intratumoral haemorrhage on MRI, characterized by high signal intensity on short TR/TE sequences. This was verified in all but 1 patient. The majority of the bleedings occurred in macroadenomas. Five (42%) were prolactinomas and 4 (33%) were non-functioning adenomas. There were 2 GH- and 1 ACTH-secreting tumours. All 5 patients with prolactinomas were on bromocriptine medication. Two of the patients had a clinical picture of pituitary apoplexy. The haemorrhage was not large enough to prompt surgery in any of the patients. However, surgical verification of the diagnosis was obtained in 5 cases, while 6 patients were examined with follow-up MRI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    ISSN: 1432-1920
    Keywords: Hallucinations ; Peduncular hallucinosis ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of peduncular hallucinosis (Lhermitte's syndrome), unusual in that there were no associated neurological signs and the symptoms persisted over many years. Magnetic resonance imaging demonstrated the typical midbrain lesion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1432-1920
    Keywords: Chiari malformation ; Syringomyelia ; Magnetic resonance imaging ; Cine-MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cine-MRI with presaturation bolus tracking was used in patients with syringomyelia associated with a Chiari malformation to study pulsatile movement of the hindbrain, cervical spinal cord, cerebrospinal fluid and the fluid within the syrinx. Nine patients had 13 examinations, 6 preoperative, 3 after syringosubarachnoid shunting and 4 after posterior fossa decompression. Five controls were also examined. Dynamic display of the acquired images demonstrated downward displacement of the presaturation bolus on the cerebellar tonsils and medulla oblongata (or upper cervical cord) at the C1 level in all preoperative examinations and in two patients after syringo-subarachnoid shunting but with residual foramen magnum obstruction. Downward displacement of the bolus on the cervical spinal cord was also demonstrated in 7 examintions, but not observed in the controls. Thus, the hind-brain-spinal cord axis showed larger pulsatile movements in patients with foramen magnum obstruction. Based on these observations and a review of the literature, a new theory on the mode of extension of syringomyelia, emphasising the role of increased pulsatile movement of the hind-brain-spinal cord axis is proposed: that the pulsatile movements, together with a one-way valve mechanism in the syrinx cavity act as a “vacuum-pump” to enlarge the syrinx.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 139-140 
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; polyneuritis ; Guillain Barré syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report gadolinium-enhancing nerve root lesions in a 52-year-old man with typical Guillain-Barré syndrome (GBS). This enhancement correlates well with the perineurial inflammatory and demyelinating processes known to characterize GBS and other inflammatory neuropathies. MRI should enable further exploration of patterns of disease in GBS and, with further study, perhaps assist in evaluating therapy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 148-151 
    ISSN: 1432-1920
    Keywords: Cerebellum ; Hypoplasia ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cerebellar hypoplasia may present with a wide variety of neurological and systemic features, ranging from aplasia causing neonatal death to mild hypoplasia in an asymptomatic adult. MRI clearly documents the size of the cerebellum and any associated abnormalities. We describe 7 cases of cerebellar hypoplasia of varying aetiology-3 inherited, 2 associated with spinal dysraphism, 1 with Joubert's syndrome and 1 with pontine agenesis, probably as a result of basilar artery infarction in utero. T1- and T2-weighted images were obtained in each case and gadolinium-DTPA was administered in one. Associated features such as a Chiari malformation (2 cases), brain stem hypoplasia (2 cases), Dandy-Walker cyst and pachygyria (3 cases) and spinal dysraphism (2 cases) were clearly identified. Accurate documentation of these appearances assists in genetic counselling.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 1432-1920
    Keywords: Cerebrospinal fluid flow ; Cerebrospinal fluid production ; Magnetic resonance imaging ; Normal pressure hydrocephalus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract An interleaved velocity-sensitised fast low-angle shot pulse sequence was used to study cerebrospinal fluid (CSF) flow in the cerebral aqueduct, and supratentorial CSF production in 9 patients with normal pressure hydrocephalus (NPH) and 9 healthy volunteers. The peak aqueduct CSF flow, both caudal and rostral, was significantly increased in patients with NPH. No significant difference in the supratentorial CSF production rate was found between patients (mean 0.60+/−0.59 ml/min) and healthy volunteers (mean 0.68+/−0.31 ml/min). Our method may be useful for investigation and monitoring of patients with NPH before and after ventriculoperitoneal shunt operations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 216-220 
    ISSN: 1432-1920
    Keywords: Acute disseminated encephalomyelitis ; Postviral encephalitis ; Brain, demyelination ; Magnetic resonance imaging ; Gadolinium ; Central nervous system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A retrospective analysis of CT and MRI studies in 12 patients with a clinical diagnosis of acute disseminated encephalomyelitis (ADEM) was performed. MRI was the definitive modality for the assessment of the lesions of ADEM: all patients had abnormalities consistent with the clinical diagnosis. Ten had abnormalities in the brain, three spinal cord lesions, and three showed evidence of optic neuritis. CT was normal in 6 of the 7 patients in which it was performed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1432-1920
    Keywords: Basal ganglia ; Encephalitis ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of acute bilateral striatal necrosis in an infant. CT and MRI findings are described.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 247-248 
    ISSN: 1432-1920
    Keywords: Hallervorden-Spatz disease ; Magnetic resonance imaging ; Iron ; Gradient-echo
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a 10-year-old girl, with progressive motor disturbance since the age of seven years and dominant pyramidal signs, MRI revealed marked overall low signal from the globus pallidus on each side, with central zones of high signal. There was also strikingly low signal in the zona reticularis of the substantia nigra, indicative of Hallervorden-Spatz disease (HSD).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 271-272 
    ISSN: 1432-1920
    Keywords: Atrial myxoma ; Cerebral infarction ; Magnetic resonance imaging ; Echocardiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We describe the radiologic investigation of two patients with primary left atrial myxoma who presented with embolic manifestations in the brain. MRI and CT showed multiple infarcts, while the cardiac atrial mass was demonstrated in one of the patients by MRI and in both by echocardiography.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 269-270 
    ISSN: 1432-1920
    Keywords: Lateral medullary infarction ; cerebellar infarction ; Wallenberg's syndrome ; Magnetic resonance imaging ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a case of Wallenberg's syndrome, infarction of the dorsolateral medulla was shown to be caused by thrombosis of the left vertebral artery, as demonstrated by T1-weighted magnetic resonance imaging, magnetic resonance angiography and conventional angiography.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 292-294 
    ISSN: 1432-1920
    Keywords: Hypertrophic pachymeningitis ; Tentorium ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Hypertrophic pachymeningitis is a rare fibrosing inflamatory process involving dura mater and tentorium. In this report we are presenting contrast enhanced MRI findings of an unusual case of pachymeningitis which presented with a periorbital mass due to dural sinuses occlusion and retrograde filling of periorbital veins through superior sagittal sinus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    ISSN: 1432-1920
    Keywords: Pituitary adenoma ; Magnetic resonance imaging ; Gadolinium ; DTPA ; Normal pituitary gland
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The position of the normal pituitary gland, assessed using gadolinium-enhanced MRI was compared with the position found at surgery for pituitary adenoma in 25 patients. The tumours were five microadenomas and 20 macroadenomas. Using T1-weighted imaging, the anterior lobe could be differentiated on the sagittal image in five patients (20%) and on the coronal image in four (16%). The high intensity of the posterior lobe could be differentiated using T1-weighted sagittal imaging in 13 patients (52%). The normal pituitary gland, which enhanced more strongly than tumour, could be differentiated using Gd-DTPA-enhanced MRI on the sagittal images in 22 cases (88%) and on the coronal image in 17 (68%). In seven patients, the normal pituitary gland surrounded the tumour; it was displaced superiorly in 14 cases and superioposterorly in two but in no case was it displaced anteriorly or downwards.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 311-312 
    ISSN: 1432-1920
    Keywords: Ganglioglioma ; Central nervous system ; Computed tomography ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We describe a ganglioglioma with atypical radiological appearances, in an uncommon location. CT showed a nonenhancing low-density lesion without calcification. On MRI the lesion gave nonspecific low signal on T1-weighted images and high signal on T2-weighted images. The tumour was in the right frontal lobe, producing bulging and thinning of the calvarium.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Fast spin-echo ; Multiple sclerosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Long repetition time (TR) spin-echo (SE) with T2- or proton density weighting is the sequence of choice to detect the brain lesions of multiple sclerosis (MS). Fast spin-echo (FSE) permits the generation of T2-weighted images with similar contrast to SE but in a fraction of the time. We compared the sensitivity of FSE and SE in the detection of the brain lesions of MS. Six patients with clinically definite MS underwent brain imaging with both dual echo (long TR, long and short echo time (TE) SE and dual echo FSE. The SE and FSE images were first reviewed independently and then compared. A total of 404 lesions was detected on SE and 398 on FSE. Slightly more periventricular lesions were detected using SE than FSE (145 vs 127), whereas more posterior cranial fossa lesions were detected by FSE (77 vs 57). With both SE and FSE the short TE images revealed more lesions than the long echo. These results suggest that FSE could replace SE as the long TR sequence of choice in the investigation of MS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    ISSN: 1432-1920
    Keywords: Optic nerve injury ; Magnetic resonance imaging ; Short inversion time inversion recovery sequence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We studied nine patients with optic nerve injury associated with closed head trauma by magnetic resonance imaging (MRI) with short inversion time inversion recovery (STIR) sequences on 11 occasions from 4 days to 14 years after the injury: three studies were within 17 days and eight over 4 months to 14 years. MRI revealed abnormal high signal in 10 of the 11 injured nerves. MRI 4 days after the injury showed no abnormality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Arteriovenous malformations ; Spinal cord ; Contrast media
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Arteriovenous fistulae and malformations (AVFs and AVMs) of the spinal cord are rare, potentially treatable causes of progressive disability. Although a variety of MRI abnormalities has been described, the diagnosis rests on the findings on selective spinal angiography.Collecting T2*-weighted MR images during the passage of a gadolinium bolus gives information about perfusion and blood volume. We carried out dynamic MRI in seven patients with vascular abnormalities (5 dural AVFs, 1 intramedullary AVM, 1 cryptic angioma) and in two patients without an AVM. High resolution T1- and T2-weighted sagittal images of the whole spinal cord were first obtained using a multiarray receiver coil. Sagittal radiofrequency spoilt gradient echo images (GE34/25, flip angle 100) were then obtained during bolus injection of gadolinium-DTPA. Abnormalities were seen in all seven patients with AVFs or AVMs. In the patient with an intramedullary AVM and four of the five with dural AVFs transient signal reduction was seen within the perimedullary venous plexus during passage of the bolus. The findings correlated well with those from selective spinal angiography. We conclude that dynamic MRI offers a useful adjunct to angiography and may localise an arteriovenous shunt when conventional MRI fails to do so. In combination with high-resolution imaging of the entire spinal cord the technique may make myelography redundant; it is simple, well tolerated and can be carried out without significant time penalty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 1432-1920
    Keywords: Brain ; Magnetic resonance imaging ; Localization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We assessed reproducible definition of two standardized co-ordinate systems for intersubject analysis of brain images. The baselines in the two co-ordinate systems were a modification of the canthomeatal (inCM) line and the anterior-posterior commissural )AC-PC) line. Axial spin-echo MR images of four subjects at 1.5T were used. Operator error was computed from the replicate analyses of two operators. The mCM line was determined by the lens of the eye and the internal auditory canal, and the AC-PC line was determined by the intersection of the AC and PC with the interhemispheric fissure. Reproducibility of the mCM markers (SD=0.59 mm) did not differ significantly from that of the AC-PC line (SD=0.68 mm). The measurement error of the angle of the baseline (δα), however, was more than 7 times as large for the AC-PC line as for the mCM line. An additional error affecting the rostrocaudal rotation of the co-ordinate systems, attributable to the distance between the anatomic markers, was 2.1 and 3.6° (3 mm and 5 mm slice thickness) for the mCM co-ordinate system and 8.2 and 11.0° (3 mm and 5 mm slice thickness) for the AC-PC system. The AC-PC line based co-ordinate system is therefore, less reproducible than the mCM line based system. this could be improved if a combination of axial and sagittal images were used for the definition of the AC-PC line.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 1432-1920
    Keywords: Multiple sclerosis ; Magnetic resonance imaging ; Corticosteroid ; Gadolinium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Treatment with methylprednisolone reduces the duration and severity of clinical relapses in multiple sclerosis (MS), while reducing the number of gadolinium-enhancing lesions on T1-weighted MRI. We performed serial MRI imaging after methylprednisolone treatment to see whether suppression of enhancement persists and whether related abnormalities on T2-weighted images disappear at follow-up. Thirteen patients with definite MS received a total of 31 courses of methylprednisolone over an average period of 50 weeks. Gadolinium-enhanced MRI was obtained before and after treatment, then at monthly intervals, using a standardised repositioning and imaging protocol. Two experienced readers in conference defined the number of active (gadolinium-enhancing and new or enlarging nonenhancing) lesions. We detected 609 active lesions on 195 examinations. Directly after treatment the reduction in the number of enhancing lesions was 78%, indicating restoration of the BBB and suppression of inflammation. It was uncommon for a lesion which stopped enhancing to show enhancement on a subsequent examination. No beneficial effect was observed on the rate of disappearance of related abnormalities on T2-weighted images, indicating persistent change such as oedema, cellular infiltration or demyelination. Moreover, in 89% of cases, an increase in the number of active lesions was observed before new clinical activity, if any, was observed (on average 52% earlier). MRI enabled us to demonstrate that the duration of the effect of methylprednisolone treatment is temporary (on average 9.7 weeks).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 36 (1994), S. 399-401 
    ISSN: 1432-1920
    Keywords: Carbon monoxide poisoning ; Cerebral white matter degeneration ; Cerebral cortical atrophy ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We examined 13 patients with chronic carbon monoxide (CO) poisoning by magnetic resonance imaging (MRI); all of them had been in an explosion in a coal mine 25 years previously. Symmetrical globus pallidus lesions were observed in 12, as was degeneration of the white matter, with focal cortical atrophy. The temporal parietal and occipital lobes were usually affected, the parietooccipital region being the most frequently and extensively damaged. Of the 12 patients with white matter degeneration 7 had definitely asymmetrical cortical and subcortical lesions. There were 6 patients with dilated temporal horns, probably due to atrophy of the hippocampal gyri. A history of CO inhalation and an awareness of the typical distributions of lesions are important for recognition of the effects of CO poisoning, especially when patients are in the chronic stage.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    ISSN: 1432-1920
    Keywords: Magnetic resonance imaging ; Basal ganglia ; Thalamus ; Complete cerebral ischaemia ; Cardiac arrest
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report specific changes bilaterally in the basal ganglia and thalamus following reperfusion after complete cerebral ischaemia. A 69-year-old man, resuscitated after cardiac arrest, showed symmetrical lowdensity lesions in the head of the caudate nucleus and lentiform nucleus on CT. MRI revealed methaemoglobin derived from minor haemorrhage in the basal ganglia and thalamus, not evident on CT. We suggest that this haemorrhage results from diapedesis of red blood cells through the damaged capillary endothelium following reperfusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    ISSN: 1432-1971
    Keywords: Aneurysmal change ; Ductus arteriosus ; Magnetic resonance imaging ; Prostaglandin E1
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We report a case of pulmonary atresia in which the ductus arteriosus underwent aneurysmal dilatation after infusion of prostaglandin E1 incorporated in lipid microspheres. To our knowledge this is the first case in which this rare morphological change has been demonstrated with the noninvasive method of magnetic resonance imaging.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric nephrology 8 (1994), S. 587-588 
    ISSN: 1432-198X
    Keywords: Wegener's granulomatosis ; Vasculitis ; Magnetic resonance imaging ; Cyclophosphamide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cutaneous manifestations occur in a significant number of patients with Wegener's granulomatosis (WG); however, the presentation and histopathology of these lesions are highly variable and may present problems in diagnosis We report the presentation of a single large skin lesion in a pediatric patient with a history of WG and the characterization of this lesion by magnetic resonance imaging (MRI) and histopathology. MRI was helpful in delineating the extent of the lesion, although a skin biopsy was necessary to confirm the diagnosis of the vasculitic natur of the lesion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric nephrology 8 (1994), S. 451-457 
    ISSN: 1432-198X
    Keywords: tuberous sclerosis complex ; Angiomyolipomatosis ; Renal cysts ; Haemorrhage ; Ultrasound ; Magnetic resonance imaging ; Renal failure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a retrospective survey performed in Germany and Switzerland, 207 patients (ranging in age from newborn to 70 years) were evaluated in order to establish the frequency, prognosis and diagnostic awareness of kidney involvement in the tuberous sclerosis complex. Renal manifestations were observed in 48% of patients: renal cysts (33 patients), renal angiomyolipoma (AML) (30 patients), a combination of both (8 patients), renal cell carcinoma (3 patients), life-threatening events such as haemorrhage (4 patients), hypertensive crisis (2 patients) and chronic renal failure (10 patients) were also documented. The diagnostic imaging techniques of ultrasonography, intravenous urography, computed tomography and magnetic resonance imaging (MRI) are important but do not always yield definitive information. Differentiation between AML and cysts can be achieved using special MRI techniques (RARE). The potential for renal involvement should be monitored in all patients with the tuberous sclerosis complex.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    ISSN: 1432-1971
    Keywords: Magnetic resonance imaging ; Pulmonary arteries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Pulmonary artery anatomy was studied in 36 patients (age range 12 days to 12.83 years, mean 2.9 years) with right ventricular outflow tract obstruction over a 3-year period using a 1.5 Tesla Magnetic Resonance system. Gated spin-echo sequences were obtained in each patient. Image planes used were straight and oblique transverse, oblique coronal, and oblique sagittal. The studies were analyzed retrospectively and comparative angiographic, surgical, and postmortem data was available in all cases. As previously noted with other imaging modalities, multiple views and oblique cuts were found to increase significantly the quality and accuracy of the information acquired. In 12 of the 15 patients who had axial and coronal imaging of both branch pulmonary arteries, the pulmonary arteries were unequivocally demonstrated to at least the first hilar branch. However, early in our experience we missed a number of branch stenoses that developed following surgical anastomoses. These mistakes were caused by inadequate or inappropriate slice acquisition. Magnetic resonance is an important technique for imaging pulmonary arteries. Careful use of the appropriate imaging planes is essential for accurate demonstration of the anatomy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 1432-1971
    Keywords: Aneurysm ; Balloon dilation ; Coarctation of aorta ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary An 11-year-old boy developed an acute aortic pseudoaneurysm during balloon dilation of unoperated coarctation of the aorta. The pseudoaneurysm occurred despite the fact that the balloon catheter size did not exceed the diameter of the aorta at the diaphragm. Elective delayed surgical repair was successfully performed after 3 weeks of antihypertensive treatment when serial magnetic resonance imaging had demonstrated a reduction in the local tissue swelling.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 1432-2161
    Keywords: Magnetic resonance imaging ; Neoplasms ; Musculoskeletal neoplasms ; Cryotherapy ; Chondrosarcoma ; Giant cell tumor of bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cryotherapy is an increasingly popular mode of therapy adjunctive to surgical curettage in the treatment of certain skeletal neoplasms, such as giant cell tumors or chondrosarcomas. The magnetic resonance (MR) findings following cryotherapy have not been previously reported. We reviewed the MR findings in seven patients with skeletal neoplasms following curettage and cryotherapy. In six cases we found a zone of varying thickness extending beyond the surgical margins, corresponding to an area of cryoinjury to medullary bone. This zone displayed low signal intensity on T1-weighted images and high signal intensity on T2-weighted images, consistent with the presence of marrow edema. This zone of edema almost certainly reflects underlying thermal osteonecrosis. This zone may vary in size and intensity over time as the area of cryoinjury evolves or resolves. MR is currently the imaging procedure of choice for follow-up of most musculoskeletal neoplasms. Knowledge of the MR findings following cryotherapy should help prevent confusion during the interpretation of follow-up MR examinations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    ISSN: 1432-2161
    Keywords: Bone tumor ; Bone neoplasm ; Magnetic resonance imaging ; Chemotherapy ; Relaxation time
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To study the effect of chemotherapy on normal fat, skeletal muscle, and bone marrow, T1 and T2 relaxation times were measured in 15 patients with bone sarcoma before and after each cycle of preoperative chemotherapy. A section plane containing the tumor and if possible the nonaffected extremity was imaged with combined multiecho spin echo and inversion recovery pulse sequences. T1 and T2 relaxation times were calculated in the normal-appearing tissues. Although some variation was found in the values in the individual patient and between patients, no systematic changes of relaxation times of fat, muscle, or bone marrow occurred in the course of treatment. We conclude that the chemotherapy used in bone sarcoma has no effect on relaxation times of normal fat, muscle, and bone marrow, and that therefore these tissues may serve as a reference for the signal intensity of tumor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 23 (1994), S. 205-210 
    ISSN: 1432-2161
    Keywords: Clavicle ; Infection ; Osteomyelitis ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Most lesions of the clavicle are traumatic and pose few diagnostic difficulties. Nontraumatic clavicular lesions, on the other hand, are rare and frequently present problems in diagnosis. This report reviews the clinical, radiologic, and bacteriologic findings in ten patients, six of whom were diagnosed as having acute osteomyelitis and four chronic osteomyelitis. The differential diagnosis of clavicular osteomyelitis is also discussed. The clinical duration of the infectious process in these patients ranged from 2 weeks to 1.5 years. All patients presented with pain; six had fever, three had localized swelling or a mass, and three had soft tissue abscesses. The radiographic findings also varied: the lesion was predominantly sclerotic in four patients, lytic in three, and mixed in two patients; in the one patient in whom magnetic resonance imaging was the only imaging study performed, these features could not be properly evaluated. Periosteal reaction was detected in three patients. Staphylococcus aureus was the causal organism in four patients, while in the remaining six patients different microorganisms were cultured, including Coccidioides immitis and Mycobacterium tuberculosis. Six patients required biopsy for final diagnosis. Although clavicular osteomyelitis is rare, particularly in adults, it should be considered in the differential diagnosis of a clavicular lesion. The final diagnosis often depends on the results of biopsy and cultures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 83-85 
    ISSN: 1432-1041
    Keywords: Enuresis ; Oxybutynine chloride ; children ; pharmacokinetics ; adverse effects ; anticholinergic actions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Anticholinergic adverse-effects in children treated with conventional doses of oxybutynine led us to measure plasma oxybutynine levels in children. 18 children, aged 5 to 13 y, who required treatment with oxybutynine chloride for daytime incontinence were studied. Plasma concentrations were measured on the fifth day of a course of treatment in which the dose was adapted to the child's body weight; the dose was given twice daily at 12-hour intervals. In 10 children aged between 5 and 8 y, the mean dose was 0.1 mg · kg−1. In 8 children aged between 10 and 13 years, the mean dose was 0.15 mg · kg−1. The highest concentration was usually found between 1 and 2 h after administration. The subsequent fall in concentration was rapid and after 6 h oxybutynine was no longer measurable in 14 of the children. The concentrations found were not different from those seen in adults given equivalent doses. The results show that plasma concentrations in children were not very different from those observed in adults if the dose were adapted to the body weight of the children. No special differences in paediatric use were revealed that might explain the particular adverse-effects. The results of the study argue against the dosage regimen proposed before these adverse events were detected. They strongly favour a dose adapted to the body weight of the child, with a 12-hour interval between doses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 1432-1041
    Keywords: Steroid 5α-reductase inhibitor ; Testosterone metabolism ; MK-0434 ; pharmacodynamics ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract A four-period, two-panel, single-rising-dose study (0.1–100 mg) was conducted in healthy males to investigate the pharmacodynamics, tolerability and pharmacokinetics of MK-0434, a steroid 5α-reductase inhibitor. MK-0434 was associated with a significant reduction in dihydrotestosterone, which was maximal at 24 h and maintained through 48 h post treatment. The maximum reduction was approximately 50 % and occurred at all doses above 5 mg (10, 25, 50 and 100 mg). MK-0434 appeared to have no effect on serum testosterone at these single doses. Rising single doses of MK-0434 were associated with an increase in Cmax and AUC but the changes were less than proportional to dose, most likely due to nonlinear absorption. MK-0434 given in single doses up to 100 mg was without significant adverse effects in healthy male volunteers. In summary, MK-0434 is a well-tolerated, potent, orally active 5α-reductase inhibitor in man.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 261-265 
    ISSN: 1432-1041
    Keywords: Cystic fibrosis ; Cyclosporin ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Cyclosporin (CsA) is currently the main immunosuppressive agent used in organ transplantation with considerable improvement in graft survival. Oral CsA solution is highly lipophilic, and its bioavailability may be reduced in cystic fibrosis (CF) heart-lung transplant recipients with pancreatic, gastrointestinal, and hepatic insufficiency. The bioavailability of oral CsA solution in 7 CF transplant recipients (5 male and 2 female with a mean age of 27 years and a mean weight of 49 kg) and 3 non-CF heart-lung recipients (1 male and 2 female with a mean age of 41 years and a mean weight of 60 kg) was studied. Following intravenous CsA administration, the kinetic curves were similar with no significant difference in the volume of distribution and clearance of CsA demonstrated between the CF and non-CF groups. The mean daily dose of oral CsA in 7 CF subjects (23.3 mg·kg−1) was significantly higher than the 3 non-CF heart-lung recipients (4.8 mg·kg−1). The mean maximum blood concentration of CsA for the oral dose was 776 ng·ml−1 for the 7 CF subjects, which was comparable with the mean peak values of 789 ng·ml−1 for the 3 non-CF control subjects. Poor enteral absorption of CsA probably accounts for the significantly lower mean bioavailability in the 7 CF subjects (14.9%) compared with the 3 non-CF control subjects (39.4%). The effects on the bioavailability of oral CsA solution by pancreatic enzymes (Creon) and histamine-2 antagonist (ranitidine) were also evaluated in the 7 CF subjects. No significant difference was demonstrated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 78
    ISSN: 1432-1041
    Keywords: Esmolol ; β1-Adrenoceptor antagonist ; tricresylphosphate ; pharmacokinetics ; effect kinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The effects of esmolol at different rates of infusion (100, 250 and 500 μg·kg−1 BW·min−1) were compared with β-adrenoceptor occupancy (β1 and β2, estimated by a subtype selective radioreceptor assay) and plasma concentrations of esmolol and its acid metabolite were measured by HPLC. Up to a rate of infusion of esmolol of 500 μg·kg−1 BW·min−1 there was a maximal β1-receptor occupancy of 84.7% while β2-receptor occupancy was below the detection limit; confirming the β1 selectivity of esmolol. Exercise-induced increases in heart rate and systolic blood pressure were reduced by esmolol in a dose-dependent manner. The estimated EC50 values of rate of infusion for the reduction in heart rate and systolic blood pressure during exercise were 113 and 134 μg·kg−1 BW · min−1, respectively. Additionally, heart rate and systolic blood pressure were reduced moderately at rest. Because of the short elimination half-life of esmolol caused by the rapid hydrolysis to its acid metabolite, 45 min after end of infusion high plasma concentrations of the metabolite (maximally 80 μg·ml−1) but no esmolol were detectable. Since no in vivo effects have been observed, despite the presence of high plasma concentrations of the metabolite, the metabolite did not participate in the observed effects up to an infusion rate of esmolol of 500 μg·kg−1 BW·min−1. The plasma concentrations of antagonist detected by radioreceptor assay and plasma concentrations of esmolol detected by HPLC showed a good correlation (r=0.97). Since the cardiovascular effects, determined before and 45 min after termination of infusion of esmolol were similar, it can be concluded that the observed effects on heart rate and systolic blood pressure are exclusively mediated by esmolol.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 1432-1041
    Keywords: Ramipril ; Piretanide ; pharmacokinetics ; pharmacodynamics ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The pharmacokinetics and pharmacodynamics of single oral doses of 5 mg ramipril and 6 mg piretanide administered separately and in combination were determined in a single blind, randomised, 3-period cross-over study in 24 healthy male volunteers. The peak plasma concentrations of ramipril and ramiprilat increased slightly (from 11.9 to 14.8 ng/ml, and from 6.39 to 8.96 ng/ml, respectively) as did the area under the plasma concentration-time curve of ramipril (0–4 h) and ramiprilat (0–24 h) (from 15.8 to 19.8 ng·ml−1·h, and from 63.4 to 74.6 ng·ml−1·h, respectively). The urinary excretion of ramiprilat also rose (from 6.82 to 7.73 % of dose) following simultaneous treatment with piretanide. These effects were probably due to reduced first-pass metabolism of ramipril/ramiprilat to inactive metabolites. The blood pressure lowering effect, the time course of inhibition of ACE activity in plasma and the concentration-response relationship for the inhibition of plasma ACE activity were not affected by piretanide. The peak plasma concentration of piretanide was somewhat reduced (from 285 to 244 ng/ml) following simultaneous treatment with ramipril. No other pharmacokinetic parameter was affected. Piretanide increased urine flow, and sodium, chloride and potassium excretion, especially during the first 2 hours following administration. These pharmacodynamic parameters were not affected by ramipril. Thus, simultaneous administration of single oral doses of ramipril and piretanide caused modest changes in the peak and average plasma concentrations of both drugs, which did not lead to detectable alterations in the pharmacodynamic parameters measured in healthy volunteers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 573-574 
    ISSN: 1432-1041
    Keywords: Standard deviation ; Arithmetic mean ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 565-567 
    ISSN: 1432-1041
    Keywords: Phenytoin ; Saliva ; therapeutic drug monitoring ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The effect of atropine-induced reductions in saliva flow rate on saliva phenytoin concentrations were evaluated in a randomised placebo-controlled crossover study in a group of epileptic patients stabilised on the drug. Pretreatment with atropine caused significant reductions in saliva flow rates during the first 4 h, compared to saline. The AUC0–4 h for saliva flow rate was significantly reduced by atropine (245 g vs 327 g) and the saliva phenytoin AUC0–4 h was significantly increased (5.6 μg · ml−1 · h vs 4.5 μg · ml−1 · h) without affecting plasma phenytoin concentrations. The saliva/plasma phenytoin AUC0–4 h ratio was therefore significantly increased by atropine (0.15 vs 0.12). However, there was a poor correlation between saliva/plasma phenytoin concentration ratios and saliva flow rates for the two treatments in the individual patients (correlation coefficient ranged from 0.25 to 0.65). These findings demonstrate that saliva phenytoin concentrations are increased by reductions in saliva flow rate. Caution is therefore required when saliva phenytoin concentrations are used for therapeutic monitoring in the presence of factors which may affect saliva flow rate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 47 (1994), S. 61-65 
    ISSN: 1432-1041
    Keywords: Cyclosporine A ; kidney transplant ; nephrotic syndrome ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The pharmacokinetic parameters of cyclosporine (CsA) were determined in 23 kidney transplant recipients and 19 children with nephrotic syndrome, after intravenous and oral administration. The mean bioavailability was 39 %, blood clearance was 0.55 l · h-1 · kg-1 and volume of distribution at steady-stade was 2.77 l · kg-1. The absorption profile was monophasic (67 %), biphasic (29 %) or poor (4 %). The maximum blood concentration of CsA was significantly higher in children with a monophasic profile than in children with a biphasic profile (550 vs 380 ng · ml-1). Blood clearance was significantly higher in the transplant recipients than in the patients with nephrotic syndrome (0.65 vs 0.43 l · h-1 · kg-1. Although age, haematocrit, creatinine clearance, serum albumin and cholesterol differed between the two groups, only haematocrit and creatinine clearance were significantly (negatively) correlated with CsA clearance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 47 (1994), S. 81-84 
    ISSN: 1432-1041
    Keywords: Dihydrotachysterol ; bioavailability ; pharmacokinetics ; human ; HPLC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The bioavailability of four preparations containing dihydrotachysterol (DHT2) was tested in two separate trials with administration of single, oral doses of 1 mg per individual. The relative bioavailability of corresponding preparations (capsules vs capsules and oral solution vs oral solution) was tested in a randomised, crossover pattern within the same group of volunteers. Two different groups of 24 healthy volunteers took part in each trial. Solution and capsule bioavailability was also compared inter-individually. A new sensitive HPLC-method (quantification limit 0.5 ng · ml-1) was used for the measurement of DHT2 concentration in serum. Three of the preparations tested had a similar bioavailability (mean AUC values of 195.5–223 ng · h · ml-1); the bioavailability of the fourth preparation (A.T.10 oral solution) was considerably lower (mean AUC value 111.5 ng · h · ml-1). The present dosage recommendations of all four preparations are identical. A new dosage recommendation is thus required for the oral solution with low bioavailability (A.T.10).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 84
    ISSN: 1432-1041
    Keywords: Doxycycline ; bioavailability ; pH dependent absorption ; pharmacokinetics ; carrageenate ; adverse events
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The effect of increased gastric pH (obtained by pre-treatment with omeprazole) on the bioavailability of doxycycline monohydrate and doxycycline carrageenate has been investigated in 24 healthy volunteers, using an open, randomised, four-treatment, four-period, crossover, 2×2 factorial design. Each subject received a single dose of 100 mg of each of the doxycycline formulations with and without pre-treatment with omeprazole (40 mg daily for 7 days). The two formulations were bioequivalent (rate and extent) during fasting without omeprazole pre-treatment, whereas after omeprazole, the monohydrate showed a highly significant decrease in bioavailability (38% for AUC and 45% for Cmax) compared to the carrageenate formulation, which was not affected by prior administration of omeprazole. Many of the subjects did not reach a therapeutic plasma level of doxycycline during the combination of omeprazole and doxycycline monohydrate, and most adverse events (mainly gastrointestinal) were reported after this combination. As large populations of patients have a high gastric pH due to frequent use of H2-blockers, proton pump inhibitors and antacids, as well as to physiological achlorhydria, the decreased absorption of doxycycline monohydrate may well have a clinical impact, for example when the patients are treated with tetracyclines for an infection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 1432-1041
    Keywords: Medifoxamine ; pharmacokinetics ; pharmacodynamics ; elderly volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The pharmacokinetics and psychomotor effects of medifoxamine, a 5 HT reuptake inhibitory antidepressant, were studied in healthy elderly volunteers after single and multiple dosing. The elimination half life (t1/2z) after single doses of 300 mg was 2.8 h — almost identical to that found in young volunteers. After seven days of dosing at 100 mg three times daily the mean corrected AUC after 300 mg significantly increased from 1.04 to 1.34 mg.h.l−1 and t1/2z increased to 4.0 h (NS). There were no significant changes in critical flicker fusion frequency, symbol digit substitution, continuous attention or choice reaction times.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 179-180 
    ISSN: 1432-1041
    Keywords: Teicoplanin ; haemodialysis ; renal failure ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 237-242 
    ISSN: 1432-1041
    Keywords: Metoprolol ; bioavailability ; bioequivalence ; receptor binding assay ; pharmacokinetics ; sustained release formulation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The bioavailability and pharmacodynamic bioequivalence of a conventional and an experimental sustained-release formulation of 100 mg metoprolol tartrate were studied in a randomised cross-over study in seven healthy volunteers by assessing over 24 h the plasma kinetics of R,S-metoprolol, its β1-adrenoceptor binding component, and by determining the extent to which the active drug moiety in plasma occupied rabbit lung β1-and rat reticulocyte β2-adrenoceptors. The formulations differed markedly in their kinetic characteristics: the peak plasma concentration (Cmax) of R,S-metoprolol after administration of the conventional formulation was 140 ng·ml−1, (n=7) and it was approximately one-third of that after the sustained-release formulation, 49 ng·ml−1, (n=6); the AUC0–24 h-values for the formulations were 700 and 310 ng·h·ml−1, respectively. The Cmax for the β1-adrenoceptor binding component of metoprolol was 180 ng·ml−1 (n=7) after administration of the conventional, and 74 ng·ml−1 after administration of the sustained-release formulation. The corresponding AUC0–24 h-values for the receptor binding component were 920 and 470 ng·h·ml−1 (n=7). Thus, the kinetic differences between R,S-metoprolol and the β1-receptor binding component were considerable and they were affected by the type of formulation. In general, after administration of the sustained-release formulation, the percentage β1- and β2-adrenoceptor occupancy of metoprolol in plasma was 5–15% less than after administration of the conventional formulation. At 0.5–1.5 h after drug intake the average β1-adrenoceptor occupancy of the conventional formulation varied between 80–90% and that of the sustained release formulation between 20–76%. At these times the differences in receptor occupancy were significant; at 0.5–2 h after drug intake the average β2-adrenoceptor occupancy of the conventional formulation varied from 20–30%, and that of the sustained-release formulation was 2–17%. At other times the difference in receptor occupancy between the formulations was not significant. The results demonstrate that plasma concentration-kinetics were more discriminating than β-adrenoceptor-binding in analysing bioequivalence. It was possible to determine the bioavailability of the active ingredient of metoprolol and to study pharmacodynamic bioequivalence by using receptor binding assays.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 575-575 
    ISSN: 1432-1041
    Keywords: Renal clearance ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 47 (1994), S. 75-79 
    ISSN: 1432-1041
    Keywords: Diltiazem ; Angina pectoris ; controlled release formulation ; metoprolol ; bioavailability ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Diltiazem CR tablets 120 mg b.i.d. for 1 week were compared with plain tablets 60 mg q.i.d. in 13 healthy male volunteers in a study of pharmcokinetic variables. Their antianginal efficacy was also compared in 23 patients with stable angina pectoris who were already on metoprolol. Both studies were of randomised, cross over design, and the clinical study was double blind. The pharmacokinetic variables of the two formulations were very similar except for the longer tmax of 4.4 h for diltiazem CR in comparison to 2.9 h for the plain tablets. The mean relative bioavailability of diltiazem CR in comparison with plain tablets was 1.14. The clinical study showed that after four weeks on diltiazem CR 120 mg b.i.d. or diltiazem plain tablets 60 mg q.i.d. in addition to metoprolol, there were significant decreases in weekly anginal attacks from 11 to 5 attacks/week, the number of nitroglycerin tablets consumed from 6 to 3 tablets/week, and an increase in the maximum workload from 116 to 126 and 123 W for diltiazem CR and plain diltiazem tablets, respectively, as compared to placebo. Five of the patients were angina free during diltiazem treatment. No difference in antianginal efficacy between the two preparations was seen. It was concluded that CR 120 mg b.i.d. appears bioequivalent to plain diltiazem tablets 60 mg q.i.d.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 90
    ISSN: 1432-1041
    Keywords: Oxcarbazepine ; 10,11-dihydro-10-hydroxy-carbamazepine ; renal impairment ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract We have studied the effect of renal impairment on the pharmacokinetics of oxcarbazepine, its active monohydroxy-metabolite (which predominates in plasma), their glucuronides, and the inactive dihydroxy-metabolite after a single oral dose of oxcarbazepine (300 mg). Six subjects with normal renal function and 20 patients with various degrees of renal impairment participated. The mean areas under the plasma concentration-time curves of oxcarbazepine and its monohydroxy-metabolite were 2–2.5-times higher in patients with severe renal impairment (CLCR〈10 ml·min−1) than in healthy subjects. The apparent elimination half-life of the monohydroxy-metabolite [19 (SD 3) h] in these patients was about twice that in healthy subjects. The effect of renal impairment on the plasma concentrations of glucuronides was more marked. The renal clearances of the unconjugated monohydroxy-metabolite and its glucuronides (the main compounds recovered in urine) correlated well with creatinine clearance. The maximum target dose in patients with slight renal impairment (CLCR〉30 ml·min−1) should not be changed. In patients with moderate renal impairment (CLCR10–30 ml·min−1) it should be reduced by 50%. In patients with severe renal impairment (CLCR〈10 ml·min−1), the glucuronides of oxcarbazepine and its monohydroxy-metabolite are likely to accumulate during repeated administration, and dosage adjustment of oxcarbazepine in these patients could not be proposed from this single administration study.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 1432-1084
    Keywords: Liver, neoplasms ; Liver, diseases ; Liver, focal nodular hypersplasia ; Magnetic resonance imaging ; Magnetic resonance imaging ; Magnetic resonance (MR), tissue characterization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Two cases of local nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage — without central scar or fibrosis — and necrotichemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless [1]: in normal liver parenchyma, a “blood steal” phenomenon due to congenital or acquired intrahepatic AVM — arterio portal or porto systemic shunt — could cause ischemic damaged, appering as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply (maintained in Case 1, and markedly reduced in Case 2 due to arterio portal shunting). The subsequent phase of repair could activate the regenerative-hyperplastic process, evolving into final fibrosis, which represents the “mature” pattern of FHN.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 92
    ISSN: 1432-1041
    Keywords: Buspirone ; pharmacokinetics ; renal impairment ; hepatic impairment ; healthy volunteers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The single dose and steady-state pharmacokinetics of buspirone and its metabolite 1-pyrimidinyl piperazine (1-PP) have been evaluated in normal volunteers and patients with renal or hepatic impairment, using a parallel group design, with assignment of patients to study group on the basis of the degree of renal (mild, moderate, severe) or hepatic (compensated or decompensated) impairment. Each healthy volunteer or patient received a single dose of 10 mg buspirone on Day 1 of the study, and starting 36 h after the first dose, healthy volunteers and patients received 10 mg doses of buspirone every 12 hours for 9 days. On the morning of Day 10 they received the last dose. Serial blood samples were collected on Days 1, 5 and 10 and plasma was analysed for buspirone and 1-PP. The plasma concentrations of buspirone and 1-PP were highly variable regardless of the renal or hepatic function. The peak concentrations (Cmax) and area under the curves (AUC) of buspirone and 1-PP on Days D 5 and 10 were higher than on Day D 1. The trough levels (Cmin) and AUCs (D 5 and 10) of buspirone and 1-PP indicated, that, regardless of renal or hepatic function, steady state was reached after 3 to 5 days of dosing. At steady-state, patients with renal or hepatic impairment had significantly higher Cmax and AUC values of buspirone than in normal volunteers. However, the intensity and frequency of adverse experiences in patients with renal or hepatic impairment were not significantly different from those observed in normal volunteers. There was no correlation between the average plasma concentrations of buspirone ( $$\bar C$$ ) and the degree of renal impairment judged by creatinine clearance. An excellent correlation was observed between $$\bar C$$ of buspirone and serum albumin (r=0.862, and P〈0.0001) as well as between $$\bar C$$ and bromsulphalein clearance (r=0.678, P〈0.0003). In view of high intra-and inter-subject variability in buspirone concentrations, definitive dosing recommendations for patients with compromised renal or hepatic function could not be made, but such patients should initially be dosed cautiously with buspirone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 371-373 
    ISSN: 1432-1041
    Keywords: Salmon calcitonin ; Skin blister fluid concentration ; synthetic ; plasma concentration ; pharmacokinetics ; adverse effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract To obtain further information about the availability of salmon calcitonin in the biophase compartment that surrounds the receptor site, salmon calcitonin concentrations in plasma and skin blister fluid (SBF) after a single IV dose of 100 IU synthetic salmon calcitonin were compared in 15 healthy volunteers. Serial blood and SBF samples were collected before and up to 8 h after administration and calcitonin was determined by a specific RIA. The maximum concentration in plasma was 225 pg·ml-1 (in the first sample at 15 min), whereas in SBF the mean peak of 84 pg·ml-1 was reached after about 30 min. The distribution of salmon calcitonin into SBF, defined as the ratio of the AUCs in SBF and plasma, was 1.5. The kinetic profiles of salmon calcitonin in plasma and interstitial fluid were different. Calcitonin in plasma peaked and then levelled out, while in SBF it persisted longer than in plasma. This is the first report of the distribution of salmon calcitonin into blister fluid.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 47 (1994), S. 157-159 
    ISSN: 1432-1041
    Keywords: Torasemide ; metabolites ; end-stage renal disease ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The pharmacokinetics of torasemide, a new loop diuretic, as well as its active metabolites M1 and M3, and its inactive main metabolite, M5, were studied in 12 patients with end-stage renal failure during single i.v. (n=6) or single oral (n=6) dosing of 200 mg torasemide, and during chronic oral treatment for 9 days (n=12). The elimination half-life (t1/2) of torasemide was unchanged in renal failure, whereas t1/2 of the torasemide metabolites M1, M3, and M5 were markedly prolonged. However t1/2 as well as the area under the plasma level time curve of torasemide and its metabolites were unchanged during chronic compared to acute administration. The results of this study suggest that despite the increased half-life of torasemide metabolites M1, M3 and M5 in end-stage renal failure patients, no accumulation of the parent drug torasemide and its metabolites during chronic dosing is demonstrable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 77-81 
    ISSN: 1432-1041
    Keywords: Trapezoidal rule ; Ethinyl estradiol ; variance components ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The concept of a weighted pool for estimating the area under the curve (AUC) is presented and set in relationship to the trapezoidal rule. An example from a pharmacokinetic study on ethinyl estradiol is used to demonstrate the use of variance component analysis for relating the intraindividual variance of the AUC, trapezoidal rule and weighted pool to the variance of the determination process. Depending on the sampling times, the theoretical variance of the weighted pool is greater than the theoretical variance of the trapezoidal rule. In the example presented, it was shown that this difference is of no importance in relation to the interindividual variance of the AUC, which dominates the total variance. In the example study, routine quality control samples were also determined in each assay, which allowed independent confirmation of the discussed results on the intraindividual variance of the AUCs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 55-58 
    ISSN: 1432-1041
    Keywords: Pemirolast ; Asthma ; theophylline ; drug interaction ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The effect of a newly developed anti-allergic drug, pemirolast potassium (TBX), on the pharmacokinetics and metabolism of theophylline was investigated under steady-state conditions in seven healthy male volunteers. A sustained-release theophylline formulation (100 mg twice daily at 12 h intervals) was given as monotherapy and coadministered with TBX (10 mg twice daily at 12 h). Plasma concentration-time curves and the urinary excretion of theophylline and its major metabolites after administration of theophylline alone and after coadministration with TBX were compared. No significant adverse effects from this study were observed. There were no significant differences in the total body clearance, renal clearance and maximum concentration of theophylline between the two treatments, although coadministration of TBX significantly delayed the time to reach maximum concentration of theophylline. In the case of urinary excretion, no significant changes in the fraction of urinary excretion of theophylline and its metabolites were observed. These results indicate that TBX has little or no effect on the pharmacokinetics and metabolism of theophylline and suggest that TBX is safe for asthma patients receiving theophylline therapy for treatment of chronic obstructive airway diseases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 1432-1041
    Keywords: Entacapone ; catechol-O-methyltransferase ; pharmacokinetics ; healthy volunteers ; adverse effects ; metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The inhibition of soluble catechol-O-methyltransferase (S-COMT) in red blood cells (RBCs) by entacapone, and the pharmacokinetics of entacapone after single oral (5–800 mg) and IV (25 mg) doses have been examined in an open study in 12 healthy young male volunteers. Oral entacapone dose-dependently decreased the activity of S-COMT in RBCs with a maximum inhibition of 82% after the highest dose (800 mg). The inhibition of S-COMT in RBCs was reversible and the activity recovered within 4–8 h. Entacapone showed linear pharmacokinetics over the dose range studied: Cmax and AUC were correlated with the dose of the drug. Oral absorption of entacapone was fast, with a tmax ranging from 0.4 to 0.9 h, depending on the dose. Systemic availability of entacapone varied between 30 and 46%. Entacapone was rapidly eliminated by metabolism with a half-life of 0.27–0.30 h after oral doses of 5 to 50 mg. After doses from 100 to 800 mg the disposition was best described by two phases with a t1/2α of 0.27–0.37 h and t1/2β of 1.59–3.44 h. Over the dose range studied, the single oral and IV doses of entacapone were well tolerated. No haematological, biochemical or haemodynamic adverse effects were seen. The results show that entacapone is an orally effective and reversible COMT inhibitor in man and has simple, linear pharmacokinetics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 98
    ISSN: 1432-1041
    Keywords: Diltiazem ; immediate-release tablet ; controlled-release tablet ; steady state ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract We have studied the controlled-release properties and relative systemic availabilities of two dosages of the same controlled-release (CR) diltiazem tablet formulation by comparing them at steady state with those of an immediate-release formulation. We measured 24-hour plasma concentration profiles during 4-day treatments with diltiazem 90 mg CR tablet bd diltiazem 120 mg CR tablet bd, and conventional diltiazem 60 mg immediate-release (IR) tablet tid. The study had a randomized, three-way crossover design. Twelve healthy men (38–52 y) participated. Trough plasma concentrations were determined on days 3 and 4. The 24-h plasma concentration-time profiles were assessed after the last morning dose on day 4 of each period. The following steady-state pharmacokinetic values were calculated: the minimum plasma concentration (Cmin), the maximum plasma concentration (Cmax), the time interval during which the plasma concentration exceeded 75% of Cmax (t75), the area under the plasma concentration-time curve (AUC72–96), the peak-to-trough fluctuation (PTF), and the area-under-the-curve fluctuation (AUCF). Steady state was achieved on day 3. The pharmacokinetics were comparable. For diltiazem CR 90 mg and diltiazem CR 120 mg, AUC84–96 (night) was approximately 75% of AUC72–84 (daytime). The diltiazem plasma concentration increased slowly from about 6 h after the evening dose of both CR tablets, resulting in relatively high plasma concentrations in the early morning hours. Only during treatment with diltiazem CR 120 mg were the plasma concentrations of diltiazem maintained above the minimum therapeutic plasma concentration of 50 μg·1−1 throughout the full 24 h. In conclusion, twice-daily treatment with diltiazem CR tablets can replace thrice-daily treatment with the conventional diltiazem IR tablet. The early morning rise of the diltiazem plasma concentration, which might lead to a lower incidence of ischaemic events, may be an important clinical advantage of both CR tablets. Because of the minimum therapeutic plasma concentration of 50 μg·1−1, twice-daily administration of the 120 mg CR tablet may be preferred from a therapeutic point of view. Diltiazem, a benzothiazepine, is a calcium antagonist used in the treatment of angina pectoris and hypertension. The anti-ischaemic mechanism of diltiazem seems to result from an increase of myocardial oxygen supply and a reduction in myocardial oxygen demand, respectively by coronary artery dilatation and/or direct and indirect haemodynamic effects, such as afterload reduction and heart rate decrease (Braunwald 1982). Its therapeutic effect is evident at daily dosages between 180 and 360 mg (Low et al. 1981). After oral administration it is almost completely absorbed from the gastrointestinal tract, but owing to extensive first-pass metabolism, its systemic availability is approximately 40–50% (Echizen and Eichelbaum 1986). The time to maximum plasma concentrations after oral administration of immediate-release formulations is approximately 3 to 4 h. The elimination half-life of diltiazem is 3.5–7 h, implying that frequent dosing is required to maintain effective plasma concentrations. Therefore, a controlled-release formulation of diltiazem, designed to be taken twice daily, has been developed. The aim of this crossover study was to compare the systemic availability and steady-state pharmacokinetics of a controlled-release diltiazem tablet formulation (90 and 120 mg) with those of a conventional diltiazem immediate-release tablet in healthy volunteers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 325-332 
    ISSN: 1432-1041
    Keywords: Factor IX ; Haemophilia B ; macromolecules ; pharmacokinetics ; methodological study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract The aims of this study were to investigate the influence of total blood sampling time on the estimated pharmacokinetic parameters of Factor IX procoagulant activity (FIX:C) and to relate the pharmacokinetics of FIX:C to the putative physiological disposition of Factor IX (FIX). Six patients with severe haemophilia B each received 2 infusions of FIX and on both occasions blood samples were collected for 104 h. Each FIX:C decay curve was processed with successive deletion of the last (remaining) datapoint. The fitted terminal half-life (t1/2β) and the calculated model-independent mean residence time (MRTMI), elimination clearance (CLMI) and volume of distribution at steady state (Vss) stabilised close to their final values when FIX:C data corresponding to at least 56 h of sampling were used. The final mean values were t1/2β=34 h, MRTMI=37 h, CLMI=4.0 ml · h-1 · kg-1 and Vss=0.15 l · kg-1. The disposition of FIX could be characterised by a two-compartment pharmacokinetic model. On average, FIX molecules spent 44% of their total MRT in the second (or “extravascular”) compartment. The distribution clearance was comparable to estimated total lymph flow. The volume of the central compartment was twice the estimated plasma volume, which may reflect the rapid and reversible binding of FIX to vascular endothelium. This explains the common clinical finding that the peak activity of FIX:C is less than the injected dose divided by the estimated plasma volume of the patient.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 46 (1994), S. 339-343 
    ISSN: 1432-1041
    Keywords: Iopromide ; X-ray contrast medium ; pharmacokinetics ; tolerability ; healthy volunteers ; adverse effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Twelve healthy male volunteers participated in a single-blind, randomised, placebo-controlled cross-over study of IV iopromide in doses of 15 g iodine or 80 g iodine infused over a period of 15 min. The volunteers were observed for three days during which time blood samples, urine and faeces were collected. The terminal disposition phase half-life of iopromide was 2 h and 1.9 h, and the total clearance was 110 and 103 ml·min-1 at the lower and at the higher dose levels, respectively. The steady state volume of distribution was 16 and 17 l, indicating predominantly extracellular distribution of iopromide. Statistical analysis (one-sided t-test) showed that all the target parameters (AUC, half-life and urinary excretion) were equivalent at both dose levels, indicating dose proportionate, first order kinetics of iopromide over the large dose range tested. Iopromide was well tolerated after both doses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...